933 resultados para Hall Angle
Resumo:
The present study aims to compare three types of internal fixation for fractures of the mandibular angle. Mechanical testing was performed on replicas of polyurethane hemimandibles sectioned at the angle region to simulate a fracture and fixed with three different hardwares. Fixation devices enrolled on this survey included the grid plates with and without an intermediate bar and the method described by Champy and colleagues in 1978 and the sample consisted of 10 hemimandibles for each group. Vertical loadings were applied on each hemimandible and recorded after a vertical displacement of 3 and 5 mm. Statistical analysis was made by means of the variance analysis (ANOVA) and the Duncan test with a significance level of 5%. The Champy technique showed a statistically significant increased resistance when compared to the grid plates after vertical displacements of 3 and 5 mm. The results of this survey suggest that the Champy technique, when compared to the grid plate positioned at the middle of the mandibular bone (placement site selected for this study), is more resistant than the grid plate and that the inclusion or not of an intermediate bar to the grid plates does not improve its resistance after linear vertical loadings.
Resumo:
The purpose of this paper was to evaluate the agreement among different methods used to estimate angular deviation of the body to determine the risk for development of upper limb musculoskeletal disorders in dentistry undergraduates. Materials and Methods: Students (n = 79) enrolled in the final year undergraduate course of the Araraquara School of Dentistry-Sγo Paulo State University-UNESP were evaluated. Photographs were taken of students performing clinical procedures. The work postures adopted by each student were evaluated by means of rapid upper limb assessment (RULA). The basis used to obtain the individual's final risk score is the measurement of the angular deviations in the neutral positions of the regions evaluated. Two methods were used to estimate the angular deviation of the body: Visual exam and Image Tool software. A RULA final risk score was attributed to each procedure the student performed (n = 333). Study of the agreement between the methods about risk of musculoskeletal disorders was conducted by means of Kappa (κ) statistics. The level of significance adopted was 5%. Results: Fair agreement (κ = 0.32) between the evaluated methods was verified. Conclusion: The risk for development of upper limb musculoskeletal disorders by dentistry undergraduates evaluated by using RULA was not in agreement with the results obtained by use of visual exam and Image Tool.
Resumo:
The purpose of this paper was to evaluate the agreement among different methods used to estimate angular deviation of the body to determine the risk for development of upper limb musculoskeletal disorders in dentistry undergraduates. Materials and Methods: Students (n = 79) enrolled in the final year undergraduate course of the Araraquara School of Dentistry-Sγo Paulo State University-UNESP were evaluated. Photographs were taken of students performing clinical procedures. The work postures adopted by each student were evaluated by means of rapid upper limb assessment (RULA). The basis used to obtain the individual's final risk score is the measurement of the angular deviations in the neutral positions of the regions evaluated. Two methods were used to estimate the angular deviation of the body: Visual exam and Image Tool software. A RULA final risk score was attributed to each procedure the student performed (n = 333). Study of the agreement between the methods about risk of musculoskeletal disorders was conducted by means of Kappa (κ) statistics. The level of significance adopted was 5%. Results: Fair agreement (κ = 0.32) between the evaluated methods was verified. Conclusion: The risk for development of upper limb musculoskeletal disorders by dentistry undergraduates evaluated by using RULA was not in agreement with the results obtained by use of visual exam and Image Tool.
Resumo:
To evaluate the influence of variations in the working angle of the piezoelectric ultrasonic scaler (PUS) on root surfaces. Material and methods Fifty-five uniradicular bovine teeth were used, of which 25 teeth were used for the analysis of the roughness and root wear, while the remaining 30 teeth were used for the analysis of morphology (MRS) and the attachment of blood components (ABC). The teeth were randomly divided into five groups according to the type of treatment (G1-G5: piezoelectric ultrasonic scaler; G6: manual curette) and to the PUS working angle applied (G1: 0°; G2: 30°; G3: 45°; G4: 60°; G5: 90°). For statistical analysis, the data describing the MRS and ABC were analysed by the Kruskal–Wallis and Dunn's tests, and the data describing the roughness and tooth wear were analysed by anova and Tukey's tests at the significance level of 5%. Results Manual curette (MC) promoted a smoother root surface than the application of the PUS. The PUS used at the angles of 30° and 45° resulted in a high level of ABC that was comparable to that obtained by MC. Additionally, the group in which the PUS was applied at an angle of 45° exhibited less tooth wear than the other groups. Conclusions Changes in the working angle of the PUS influenced the characteristics of root surfaces after instrumentation.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
We present results of a search for continuously emitted gravitational radiation, directed at the brightest low-mass x-ray binary, Scorpius X-1. Our semicoherent analysis covers 10 days of LIGO S5 data ranging from 50-550 Hz, and performs an incoherent sum of coherent F-statistic power distributed amongst frequency-modulated orbital sidebands. All candidates not removed at the veto stage were found to be consistent with noise at a 1% false alarm rate. We present Bayesian 95% confidence upper limits on gravitational-wave strain amplitude using two different prior distributions: a standard one, with no a priori assumptions about the orientation of Scorpius X-1; and an angle-restricted one, using a prior derived from electromagnetic observations. Median strain upper limits of 1.3 x 10(-24) and 8 x 10(-25) are reported at 150 Hz for the standard and angle-restricted searches respectively. This proof-of-principle analysis was limited to a short observation time by unknown effects of accretion on the intrinsic spin frequency of the neutron star, but improves upon previous upper limits by factors of similar to 1.4 for the standard, and 2.3 for the angle-restricted search at the sensitive region of the detector.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A measurement of differential cross sections for the production of a pair of isolated photons in proton-proton collisions at root s = 7 TeV is presented. The data sample corresponds to an integrated luminosity of 5.0 fb(-1) collected with the CMS detector. A data-driven isolation template method is used to extract the prompt diphoton yield. The measured cross section for two isolated photons, with transverse energy above 40 and 25 GeV respectively, in the pseudorapidity range vertical bar eta vertical bar < 2.5, vertical bar eta vertical bar (sic) [1.44, 1.57] and with an angular separation Delta R > 0.45, is 17.2 +/-0.2 (stat) +/-1.9 (syst) +/- 0.4 (lumi) pb. Differential cross sections are measured as a function of the diphoton invariant mass, the diphoton transverse momentum, the azimuthal angle difference between the two photons, and the cosine of the polar angle in the Collins-Soper reference frame of the diphoton system. The results are compared to theoretical predictions at leading, next-to-leading, and next-to-next-to-leading order in quantum chromodynamics.
Resumo:
The influence of the Hall effect on stationary convection in shearless current-carrying plasma columns is considered. It is shown that the Hall effect can inhibit the formation of convection cells generated by viscosity and resistivity.
Resumo:
To assess the intraocular pressure (IOP)-lowering effect of travoprost 0.004%/timolol 0.5% fixed-dose combination (TRAV/TIM-FC) in patients not achieving the target IOP of ≤18 mmHg while on timolol 0.5% (TIM) monotherapy. A multicenter, prospective, open-label study (NCT01336569) was conducted in patients with open-angle glaucoma or ocular hypertension. Eligible patients were receiving TIM monotherapy with a screening/baseline IOP of 19-35 mmHg in ≥1 eye. TIM was discontinued on the baseline visit day (no washout period) and TRAV/TIM-FC was initiated and administered once daily at 8 pm for 4-6 weeks. The primary efficacy variable was mean change in IOP from TIM-treated baseline to study end, measured by Goldmann applanation tonometry. Results were analyzed by analysis of variance and paired samples t-test (5% significance). A total of 49 patients were enrolled (mean age, 63 [range, 42-82] years; 55.1% White; 73.5% women), and 45 were included in the intent-to-treat (ITT) population. Mean duration of treatment with TRAV/TIM-FC was 31 days. Mean ± standard deviation IOP reduction from baseline (TIM) to the follow-up visit (TRAV/TIM-FC) was -5.0±3.6 mmHg. IOP decreased significantly (P<0.0001) from baseline (22.1±2.6 mmHg) to study end (17.1±3.9 mmHg) in the ITT population, with a mean IOP reduction of 22.3%. Most patients (n=33/45; 73.3%) achieved IOP ≤18 mmHg. Two patients experienced a total of four adverse events (AEs), including a patient who reported one serious AE (enterorrhagia) that was considered unrelated to treatment, and a patient who reported one event each of drug-related redness, pruritus, and foreign body sensation. Most patients (n=47/49; 95.9%) reported no AEs. TRAV/TIM-FC lowered IOP in patients who were not at target IOP while receiving TIM monotherapy, with most patients achieving an IOP ≤18 mmHg with TRAV/TIM-FC. TRAV/TIM-FC was well tolerated in this population.
Resumo:
The elevated Q-angle seems to be one of the most suggested factors contributing to patellofemoral pain. Females with patellofemoral pain are often evaluated through static clinical tests in clinical practice. However, the adaptations seem to appear more frequently in dynamic conditions. Performing static vs. dynamic evaluations of widely used measures would add to the knowledge in this area. Therefore, the aim of this study was to determine the reliability and discriminatory capability of three Q-angle measurements: a static clinical test, peak dynamic knee valgus during stair ascent and a static measurement using a three-dimensional system. Twenty-nine females with patellofemoral pain and twenty-five pain-free females underwent clinical Q-angle measurement and static and dynamic knee valgus measurements during stair ascent, using a three-dimensional system. All measurements were obtained and comparisons between groups, reliability and discriminatory capability were calculated. Peak dynamic knee valgus was found to be greater in the patellofemoral pain group. On the other hand, no significant effects were found for static knee valgus or clinical Q-angle measurements between groups. The dynamic variable demonstrated the best discriminatory capability. Low values of reliability were found for clinical Q-angle, in contrast to the high values found for the three-dimensional system measurements. Based on our findings, avoiding or correcting dynamic knee valgus during stair ascent may be an important component of rehabilitation programs in females with patellofemoral pain who demonstrate excessive dynamic knee valgus. Q-angle static measurements were not different between groups and presented poor values of discriminatory capability.
Resumo:
ln order to predict the facial growth using Jarahak's analysis, cephalometric radiographies of 120 subjects during the mixed dentition and between 6 and 10 years of age were studied. From the total, 60 subjects (30 males and 30 females) were classified as Angle's Class I and 60 subjects (30 males and 30 females) were classified as Angle's Class II, Division 1. AIl subjects did not receive any orthodontic treatment. The proportion between anterior and posterior facial heigth (SGo-NMe) was studied, which is determined by the formula PFH x 100/ AFH = %, neither being straight (> 62% < 65), clockwise ( > 58% < 62%) and anti-clockwise ( > 65% - 80%). Mean average, standard deviation and facial height proportion (SGo - NMe) were determined for males and females according to Angle's classification of malocc!usion. Sexual dimorphism was examined with regard to different types of Angle's malocclusion and the direction of the facial growth, and the correlation of four cephalometrics measurements were analvsed
Resumo:
Pós-graduação em Biopatologia Bucal - ICT
Resumo:
Small-angle X-ray scattering (SAXS) was used to study structural characteristics of human serum albumin (HSA) in solution under different pH conditions. Guinier analysis of SAXS results yielded values of the molecular radius of gyration ranging from 26.7 Å to 34.5 Å for pH varying from 2.5 to 7.0. This suggests the existence of significant differences in the overall shape of the molecule at different pH. Molecular models based on subdomains with different spatial configurations were proposed. The distance distribution functions associated with these models were calculated and compared with those determined from the experimental SAXS intensity functions. The conclusion of this SAXS study is that the arrangement of molecular subdomains is clearly pH dependent; the molecule adopting more or less compact configuration for different pH conditions. The conclusions of this systematic study on the modification in molecular shape of HSA as a response to pH changes is consistent with those of previous investigations performed for particular pH conditions.