976 resultados para Groundwater abstraction
Resumo:
Technology scaling has proceeded into dimensions in which the reliability of manufactured devices is becoming endangered. The reliability decrease is a consequence of physical limitations, relative increase of variations, and decreasing noise margins, among others. A promising solution for bringing the reliability of circuits back to a desired level is the use of design methods which introduce tolerance against possible faults in an integrated circuit. This thesis studies and presents fault tolerance methods for network-onchip (NoC) which is a design paradigm targeted for very large systems-onchip. In a NoC resources, such as processors and memories, are connected to a communication network; comparable to the Internet. Fault tolerance in such a system can be achieved at many abstraction levels. The thesis studies the origin of faults in modern technologies and explains the classification to transient, intermittent and permanent faults. A survey of fault tolerance methods is presented to demonstrate the diversity of available methods. Networks-on-chip are approached by exploring their main design choices: the selection of a topology, routing protocol, and flow control method. Fault tolerance methods for NoCs are studied at different layers of the OSI reference model. The data link layer provides a reliable communication link over a physical channel. Error control coding is an efficient fault tolerance method especially against transient faults at this abstraction level. Error control coding methods suitable for on-chip communication are studied and their implementations presented. Error control coding loses its effectiveness in the presence of intermittent and permanent faults. Therefore, other solutions against them are presented. The introduction of spare wires and split transmissions are shown to provide good tolerance against intermittent and permanent errors and their combination to error control coding is illustrated. At the network layer positioned above the data link layer, fault tolerance can be achieved with the design of fault tolerant network topologies and routing algorithms. Both of these approaches are presented in the thesis together with realizations in the both categories. The thesis concludes that an optimal fault tolerance solution contains carefully co-designed elements from different abstraction levels
Resumo:
The design methods and languages targeted to modern System-on-Chip designs are facing tremendous pressure of the ever-increasing complexity, power, and speed requirements. To estimate any of these three metrics, there is a trade-off between accuracy and abstraction level of detail in which a system under design is analyzed. The more detailed the description, the more accurate the simulation will be, but, on the other hand, the more time consuming it will be. Moreover, a designer wants to make decisions as early as possible in the design flow to avoid costly design backtracking. To answer the challenges posed upon System-on-chip designs, this thesis introduces a formal, power aware framework, its development methods, and methods to constraint and analyze power consumption of the system under design. This thesis discusses on power analysis of synchronous and asynchronous systems not forgetting the communication aspects of these systems. The presented framework is built upon the Timed Action System formalism, which offer an environment to analyze and constraint the functional and temporal behavior of the system at high abstraction level. Furthermore, due to the complexity of System-on-Chip designs, the possibility to abstract unnecessary implementation details at higher abstraction levels is an essential part of the introduced design framework. With the encapsulation and abstraction techniques incorporated with the procedure based communication allows a designer to use the presented power aware framework in modeling these large scale systems. The introduced techniques also enable one to subdivide the development of communication and computation into own tasks. This property is taken into account in the power analysis part as well. Furthermore, the presented framework is developed in a way that it can be used throughout the design project. In other words, a designer is able to model and analyze systems from an abstract specification down to an implementable specification.
Resumo:
The 3-methylindole (3MI) oxygenation sensitized by psoralen (PSO) has been investigated in 100%, 20% and 5% O2-saturated water/dioxane (H2O/Dx) mixtures. The lowering of the ¹O2* chemical rate when water (k chem∆3MI = 1.4 × 109 M-1 s-1) is replaced by deuterated water (k chem∆3MI = 1.9 × 108 M-1 s-1) suggests that hydrogen abstraction is involved in the rate determining step. A high dependence of the chemical rate constant on water concentration in H2O/Dx mixtures was found showing that water molecules are absolutely essential for the success of the 3MI substrate oxidation by ¹O2* in water-rich solvent mixtures.
Resumo:
Few articles deal with lead and strontium isotopic analysis of water samples. The aim of this study was to define the chemical procedures for Pb and Sr isotopic analyses of groundwater samples from an urban sedimentary aquifer. Thirty lead and fourteen strontium isotopic analyses were performed to test different analytical procedures. Pb and Sr isotopic ratios as well as Sr concentration did not vary using different chemical procedures. However, the Pb concentrations were very dependent on the different procedures. Therefore, the choice of the best analytical procedure was based on the Pb results, which indicated a higher reproducibility from samples that had been filtered and acidified before the evaporation, had their residues totally dissolved, and were purified by ion chromatography using the Biorad® column. Our results showed no changes in Pb ratios with the storage time.
Resumo:
Pesticides can be quite useful in agricultural production, however, some pesticides after application can reach and contaminate the hydric resource. Pesticide monitoring must be careful because it is expensive and lengthy. Thus, in this work, a theoretical prediction was made using the approaches suggested by EPA-USA, the Groundwater Ubiquity Score index (GUS) and the Goss method associated with physicochemical properties of 27 pesticides used in a region in the south of Brazil. The results of this work led to the identification of the pesticides that should be prioritized in the environmental monitoring due to their high potential for contaminating water resources.
Resumo:
This work reports an alternative, fast and robust method, for the determination of total As, As(III) and As(V) by HG-AAS without the use of prereductants. The method is based on the different rates of arsine formation of the inorganic As species and the effect of As(III) in the signal obtained for total As. Groundwater and mineral spiked waters were used to sample preservation evaluation. The method was validated by the determination of As in SRM 1640 and used in the determination of total As and its inorganic species in groundwater samples collected from mines in the Iron Quadrangle - MG.
Resumo:
Pharmaceutical compounds have been detected in sewage treatment plant (STP) effluents, surface waters and, less frequently, in groundwater and drinking water, all over the world. Different sources are responsible for their appearance in the aquatic environment, however, it is widely accepted that the main sources of this type of pollutant are STP effluents. The adverse effects of pharmaceuticals in the environment include aquatic toxicity, development of resistance in pathogenic bacteria, genotoxicity and endocrine disruption. Thus, the discharge of these compounds to the environment in STP effluents should be minimized.
Resumo:
The objective this study was to monitor pesticide residues in groundwater at three different times and in seven regions producing rice in southern Brazil, in the 2007/08 season. Imazethapyr and fipronil were found in all regions studied. All groundwater samples from the Planície Costeira Interna to Lagoa dos Patos and Santa Catarina contained at least one pesticide. The lowest number of contaminated samples were detected in the Southern region. The highest frequency of contaminated samples was found after drainage of the rice fields. Only fipronil exceeded limits of potability, in 27% of samples, according European Community criteria.
Resumo:
A preliminary analyses of the possible contamination of surface and groundwater by the active ingredients of the pesticide products used in the areas with intensive agricultural activities of Alto Paranaíba region, MG, Brazil, was carried out. The active ingredients and formulated products most used in the region were identified and their characteristics of environmental importance were presented. The EPA screening criteria, the groundwater ubiquity score (GUS) and the criteria proposed by Goss were used to evaluate which pesticides might contaminate the local waters. Among the active ingredients studied, several present risks to the local aquatic environment.
Resumo:
This study assesses the importance of groundwater discharge to dissolved nutrient levels in Mangueira Lagoon. A transect of an irrigation canal in the margin of Lagoon demonstrated a strong geochemical gradient due to high groundwater inputs in this area. Using 222Rn as a quantitative groundwater tracer, we observed that the flux of dissolved inorganic nitrogen (DIN), silicate and phosphate (1178 and 1977; 26190 and 35652; 167 and 188 mol d-1 for winter and summer, respectively) can continually supply/sustain primary production. The irrigation canals act as an artificial underground tributary and represent a new source of nutrients to coastal lagoons.
Resumo:
Antimicrobials, among other veterinary drugs, are used worldwide in industry and agriculture to protect animal health and prevent economic loss. In recent years, they have been detected in various environmental compartments, including soil, surface and groundwater and have become a topic of research interest. Emphasizing this class of compounds, this review presents the different pathways which veterinary drugs enter in the environment, in particular contaminate soils. Also are presented regulatory aspects and guidelines, adsorption/desorption and degradation of these compounds in soils and the consequences of its dispersal in the environment.
Resumo:
The first diagnosis of risk of environmental contamination was conducted for an area of intense agricultural activity in the semiarid cearense (Baixo Jaguaribe and Litoral de Aracati area). We verified the use of 201 rural products (pesticides) in the region, comprising 151 active ingredients. Regarding the active ingredients evaluated, 15.9% were associated with sediment and 29.8% were dissolved in surface water. The study showed that 13.2% to 36.4% of the active ingredients evaluated were classified as potential contaminants of groundwater resources. The study also revealed the most abundant pesticides and which environmental compartment must be evaluated.
Resumo:
The triplet excited state of xanthone was generated and characterized by laser flash photolysis in acetonitrile (λmax=620 nm; t=1.8 ms) and in ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate [bmim.PF6] (λmax=620 nm; t=3.0 ms). It reacts with phenols yielding the corresponding xanthone ketyl radical. Stern-Volmer plots for the reaction of triplet xanthone with phenols led to the determination of absolute rate constants for phenolic hydrogen abstraction in the order of ~10(9) Lmol-1s-1 in acetonitrile and ~10(8) Lmol-1s-1 in [bmim.PF6]. The lower diffusioncontrolled rate constant for [bmim.PF6] is responsible for the difference in the phenolic hydrogen abstraction rate constants in this solvent.
Resumo:
Two methods using headspace solid-phase microextraction and gas chromatography - mass spectrometry were developed for the determination of polycyclic aromatic hydrocarbons (PAH) and BTEX. Best results were obtained using DVB/CAR/PDMS fiber, with 10 min extraction at 25 °C and 0.15 min desorption at 260 °C (BTEX), and PDMS/DVB fiber, with 60 min extraction at 90 °C, 10% NaCl and 5 min desorption at 270 °C (PAH). LOD intervals were 3x10-2 - 5x10-2 µg L-1 (BTEX) and 1.6x10-3 - 1.4 µg L-1 (PAH). The methods were applied to forty-five groundwater samples from monitoring wells of gas stations and only benzene level exceeded the limit established by Brazilian regulations.
Resumo:
Diplomityö on osa Mikkelin ammattikorkeakoulun YTI:ssä vuosina 2005 - 2008 toteutettua ”Yritysten ympäristöriskit” EU-osarahoitteista hanketta. Työn tarkoituksena oli tunnistaa, arvioida ja luokittaa Etelä-Savossa, Juvalla toimivan yhdyskuntajätevedenpuhdistamon ympäristöriskit sekä antaa neuvoja löytyneiden riskien hallintaan. Jätevedenpuhdistamon toiminnasta syntyvät mahdolliset ympäristöriskitekijät tunnistettiin kirjallisuusselvitysten sekä haastattelujen avulla. Riskien tunnistamisen jälkeen riskien kartoittamiseen, arviointiin ja luokittamiseen käytettiin osia eri riskianalyysimenetelmistä. Riskit jaettiin viiteen eri riskiluokkaan; vakavasta riskistä merkityksettömään riskiin. Juvan kunnan jätevedenpuhdistamolla esiintyi neljän pienimmän riskiluokan riskejä, ja vakavia riskejä ei kartoituksessa tullut esille lainkaan. Riskejä arvioitiin niin sanotuissa normaalioloissa. Merkittävin yksittäinen riskitekijä jätevedenpuhdistamolla oli haitallisen tai poikkeavan aineen kulkeutuminen jäteveden mukana puhdistamolle. Tämä voisi heikentää puhdistamon puhdistustulosta merkittävästi. Kun laitosta ajetaan ympäristöluvassa asetettujen vaatimusten mukaisesti ja alueella sijaitsevat teollisuuslaitokset noudattavat heille annettuja määräyksiä, ei Juvan jätevedenpuhdistamolta aiheudu merkittäviä päästöjä maa-perään tai pohjavesiin.