971 resultados para Gases, Asphyxiating and poisonous


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aims of this study were to evaluate the isoflurane sparing and clinical effects of a constant rate infusion of morphine - lidocaine - ketamine (MLK) in healthy sheep undergoing experimental gastrointestinal surgery. Twelve adult female sheep (Texel breed) were used, weighing 36.5 +/- 8.1 kg. The sheep were anesthetized for the implantation of duodenal cannulas. The sheep were premedicated with 0.3 mg kg(-1) intramuscular (IM) morphine and 20 mu g kg(-1) intravenous (IV) detomidine. After premedication, anesthesia was induced using 5 mg kg(-1) ketamine and 0.5 mg kg(-1) diazepam IV and maintained using isoflurane in 100% oxygen. After the induction of anesthesia, the animals were allocated into two groups (each n=6); the GMLK (MLK group - 10 mg morphine, 150 mg lidocaine, 30 mg de ketamine were added in 500 mL saline) received a 10 mL kg(-1)h(-1) MLK infusion during the maintenance of anesthesia, and GCON (control group) received 10 mL kg(-1)h(-1) of 0.9% sodium chloride. The animals were mechanically ventilated. Cardiopulmonary variables and end-tidal isoflurane concentration (FE'Iso) were measured at baseline (immediately before the surgery) and 15, 30 and 45 minutes after initiation of surgery. In GMLK, there was a decrease in the FE 'Iso at 15, 30 and 45 minutes, a reduction of up to 75.6% during the surgery. The HR was lower in GMLK compared with GCON at 30 minutes, and the MAP was at during baseline in GCON compared with GMLK. The standing time was less in GMLK than in GCON. The use of intravenous MLK was demonstrated to offer great efficiency as part of a balanced anesthesia protocol in sheep, with a 75.6% reduction in the need for isoflurane, providing stability of the cardiovascular parameters and blood gases with a shortened recovery period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The state of insulating oils used in transformers is determined through the accomplishment of physical-chemical tests, which determine the state of the oil, as well as the chromatography test, which determines possible faults in the equipment. This article concentrate on determining, from a new methodology, a relationship among the variation of the indices obtained from the physical-chemical tests with those indices supplied by the chromatography tests.The determination of the relationship among the tests is accomplished through the application of neural networks. From the data obtained by physical-chemical tests, the network is capable to determine the relationship among the concentration of the main gases present in a certain sample, which were detected by the chromatography tests.More specifically, the proposed approach uses neural networks of perceptron type constituted of multiple layers. After the process of network training, it is possible to determine the existent relationship between the physical-chemical tests and the amount of gases present in the insulating oil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is great concern about the possible harmful effects of exposure to volatile anesthetics. The current study aimed at evaluating, for the first time, the effects of occupational exposure to anesthetic gases on physicians who work in operating rooms, by determining several inflammatory cytokines. Plasma inflammatory cytokines (IL-1β, -6, -8, -10, -12, TNF-α) were investigated in 30 individuals who were allocated into two groups of 15: the exposed group, consisting of operating room medical personnel exposed to a mixture of anesthetic gases for 3 years, and a control group composed of medical personnel not exposed to anesthetic gases. The concentrations of volatile anesthetics were measured in the operating room by means of an infrared portable analyzer Our findings suggest an increase of the pro-inflammatory IL-8 (p < 0.05) in medical personnel exposed to high concentrations of anesthetic gases, even for a relatively short period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)