948 resultados para Fixed partial denture
Resumo:
Purpose: The purpose of this study was to assess, through electromyographic activity (EMG), the silent period (SP) of masseter and anterior temporal muscles in dentate subjects (DS) and complete denture wearers (CDW).Materials and Methods: The evaluations were performed at the initial and final period of the mastication for the DS group. For the CDW group, the evaluations were performed at the initial period of mastication, with old complete dentures worn for more than 10 years (OCDW) and at the final period of the mastication with new complete dentures (NCDW), 5 months after rehabilitation. Twenty-four asymptomatic subjects (12 DS, 12 CDW) answered a questionnaire based on the Research Diagnostic Criteria for temporomandibular disorders. The CDW group answered the questionnaire before and after new denture insertion and after 5 months of rehabilitation. The SP of the muscles was recorded through EMG at the initial and final periods of mastication using artificial food (Optocal). The operator monitored 35 chewing cycles performed to grind the artificial food and selected eight open-close-clench-chewing cycles for the record.Results: The SP of the muscles analyzed with new complete dentures showed no statistical difference in comparison to the old dentures. There was a statistically significant difference in the SP between the CDW and DS groups for initial and final chewing.Conclusion: Lowered muscular capacity and ability reduced the SP of muscles after rehabilitation with NCDWs.
Resumo:
Complete and partial loss of maxillary bone may jeopardize oral physiology and generate complications as oral-sinus-nasal communication. Palatal obturator prostheses are a treatment alternative for rehabilitation of these patients. The aim of this study was to assess stress distribution, through photoelasticity, on palatal obturator prostheses associated with different attachment systems (o'ring, bar clip, and o'ring/bar clip) of implants and submitted to relining. Two photoelastic models were fabricated according to an experimental maxillary model with oral-sinus-nasal communication. One model did not present implants, whereas the other included 2 implants with 13.0 mm in length in the left ridge. Four colorless maxillary obturator prostheses were fabricated and relined with soft silicone. One of these prostheses presented no attachment system, whereas the remaining prostheses included attachment systems adapted to the implants. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope during loading with 100 N at 10 mm/s. The results were based on observation during the experiment and photographic records of stress on the photoelastic model. The bar clip system exhibited the highest stress concentration followed by o'ring/bar clip and o'ring systems. The attachment systems presented different stress distribution with greater concentration surrounding the implants and homogenous stress distribution on the photoelastic model without implants. The highest concentration of fringes occurred, in ascending order, with o'ring, o'ring/bar clip, and bar clip systems.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The effectiveness of microwave disinfection of maxillary complete dentures on the treatment of Candida-related denture stomatitis was evaluated. Patients (n = 60) were randomly assigned to one of four treatment groups of 15 subjects each; Control group: patients performed the routine denture care; Mw group: patients had their upper denture microwaved (650 W per 6 min) three times per week for 30 days; group MwMz: patients received the treatment of Mw group in conjunction with topical application of miconazole three times per day for 30 days; group Mz: patients received the antifungal therapy of group MwMz. Cytological smears and mycological cultures were taken from the dentures and the palates of all patients before treatment at day 15 and 30 of treatment and at follow-up (days 60 and 90). The effectiveness of the treatments was evaluated by Kruskal-Wallis and Mann-Whitney tests. Microbial and clinical analysis of the control group demonstrated no significant decrease in the candidal infection over the clinical trial. Smears and cultures of palates and dentures of the groups Mw and MwMz exhibited absence of Candida at day 15 and 30 of treatment. on day 60 and 90, few mycelial forms were observed on 11 denture smears (36.6%) from groups Mw and MwMz, but not on the palatal smears. Miconazole (group Mz) neither caused significant reduction of palatal inflammation nor eradicated Candida from the dentures and palates. Microwaving dentures was effective for the treatment of denture stomatitis. The recurrence of Candida on microwaved dentures at follow-up was dramatically reduced.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: The purpose of this study was to perform histological and histometric analyses of the repair process of autogenous bone grafts fixed at rat calvaria with ethyl-cyanoacrylate adhesive. Material and Methods: Thirty-two rats were divided into two groups (n=16), Group I - Control and Group II - Adhesive. Osteotomies were made at the right parietal bone for graft obtainment using a 4-mm-diameter trephine drill. Then, the bone segments were fixed with the adhesive in the parietal region of the opposite side to the donor site. After 10 and 30 days, 8 animals of each group were euthanized and the calvarias were laboratorially processed for obtaining hematoxylin and eosin-stained slides for histological and histometric analyses. Results: An intense inflammatory reaction was observed at the 10-day period. At 30 days, this reaction was less intense, despite the presence of adhesive at the recipient-site/graft interface. Graft incorporation to the recipient site was observed only at the control group, which maintained the highest graft size at 10 and 30 days. Conclusions: Although the fragment was stable, the presence of adhesive in Group II did not allow graft incorporation to the recipient site, determining a localized, discrete and persistent inflammatory reaction.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Processo FAPESP: 05/02384-4
Resumo:
Statement of problem. Microwave irradiation has been suggested as a method to disinfect denture bases. However, the effect of microwave heating on the dimensional stability of the relined denture bases is unknown.Purpose. The purpose of this study was to evaluate the dimensional stability of intact and relined acrylic resin denture bases after microwave disinfection.Material and methods. A standard brass cast simulating an edentulous maxillary arch was machined and used to fabricate 2- and 4-mm-thick denture bases (n=200), which were processed with heat-polymerized acrylic resin (Lucitone 550). The 2-mm thick-specimens (n=160) were relined with 2 mm of autopolymerizing resin (Tokuso Rebase Fast, Ufi Gel Hard, Kooliner, or New Truliner). Distances between 5 removable pins on the standard brass cast were measured with a Nikon optical comparator, and the area (mm(2)) formed by the distance between 5 pins was calculated and served as baseline. During fabrication, the pins were transferred to the intaglio surface of the specimens. Differences between the baseline area and those subsequently determined for the specimens were used to calculate the percent dimensional changes. The intact and relined denture bases were divided into 4 groups (n=10) and evaluated after: polymerization (control group P); 1 cycle of microwave disinfection (MW); daily microwave disinfection for 7 days (control group MW7); water storage for 7 days (WS7). Microwave irradiation was performed for 6 minutes at 650 W. Data were analyzed using 2-way ANOVA followed by Tukey's test (alpha=.05).Results. Intact specimens and those relined with Kooliner and New Truliner showed increased shrinkage after 1 (P=.05, .018, and .001, respectively) and 7 (P <.001, .003, and <.001, respectively) cycles of microwave disinfection. With the exception of specimens relined with Kooliner, intact specimens showed greater shrinkage than the relined specimens after 7 cycles of microwave disinfection.Conclusions. Microwave disinfection produced increased shrinkage of intact specimens and those relined with New Truliner and Kooliner.
Resumo:
Objectives: This study investigated the effect of relining, water storage and cyclic loading on the ultimate flexural strength (FSU) and on the flexural strength at the proportional limit (FSPl) of a denture base acrylic resin (Lucitone 550-L).Methods: Rectangular bars of L were made (64 mm x 10 mm x 2 mm) and relined (1.3 mm) with four relining resins (Kooliner-K, Ufi Gel Hard-UGH, Tokuso Rebase Fast-TR and New Truliner-NT). In addition, specimens relined with L and intact L specimens were made (64 mm x 10 mm x 3.3 mm). A three-point flexural test was applied on the specimens (n = 10) after (1) polymerization; (2) water storage (30 days); (3) cyclic loading (10,000 cycles at 5 Hz) and (4) water storage (30 days) + cyclic loading. Data (MPa) were analyzed with three-way ANOVA and Tukey's HSD tests (alpha = 0.05). To test for a possible correlation between FSU and FSPl, a linear regression coefficient 'r' was calculated.Results: After water storage, L-UGH and L-TR demonstrated an increased FSU (41.4950.64 MPa and 49.95-57.36 MPa, respectively) (P < 0.05). Only L-TR demonstrated an increased FSPl (20.58-24.21 MPa) after water storage (P < 0.05). L-L had the highest FSU (between 78.57 and 85.09 MPa) and FSPl (between 31.30 and 34.17 MPa) (P < 0.05). The cyclic loading decreased the FSU and FSPl of all materials (P < 0.05). Regression analysis showed a strong linear correlation between the two variables (r = 0.941).Conclusions: Water storage improved the FSU of L-UGH and L-TR and the FSPl of L-TR. L-L produced the highest FSU and FSPl. The FSU and FSPl of all materials were detrimentally influenced by cyclic loading.