918 resultados para Fair value measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The demand for an evidence-based clinical practice involving lower limb amputees is increasing. Some of the critical care decisions are related to the loading applied on the residuum partially responsible for comfort and functional outcome. This loading can be assessed using inverse dynamics equations. Typically, this method requires a gait laboratory (e.g., 3D motion analysis system, force-plates). It is mainly suited for the analysis only few steps of walking while being expensive and labour intensive. However, recent scientific and industrial developments demonstrated that discrete and light portable sensors can be placed within the prosthesis to measure accurately the loading during an unlimited number of steps and activities of daily living. Several studies indicated that method based on direct measurements might provide more realistic results. Furthermore, it is a user-friendly method more accessible to clinicians, such as prosthetists. The purpose of this symposium will be to give an overview of these additional opportunities for clinicians to obtain relevant data for evidence-based practice. The three main aims will be: • To present some of the equipment used for direct measurements, • To propose ways to analyse some key data sets, • To give some practical example of data sets for transtibial and transfemoral amputees.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, a non-linear excitation controller using inverse filtering is proposed to damp inter-area oscillations. The proposed controller is based on determining generator flux value for the next sampling time which is obtained by maximising reduction rate of kinetic energy of the system after the fault. The desired flux for the next time interval is obtained using wide-area measurements and the equivalent area rotor angles and velocities are predicted using a non-linear Kalman filter. A supplementary control input for the excitation system, using inverse filtering approach, to track the desired flux is implemented. The inverse filtering approach ensures that the non-linearity introduced because of saturation is well compensated. The efficacy of the proposed controller with and without communication time delay is evaluated on different IEEE benchmark systems including Kundur's two area, Western System Coordinating Council three-area and 16-machine, 68-bus test systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a series of publications over the last decade, Australian National University Professor Margaret Thornton has documented a disturbing change in the nature of legal education. This body of work culminates in a recently published book based on interviews with 145 legal academics in Australia, the United Kingdom, New Zealand and Canada. In it, Thornton describes a feeling of widespread unease among legal academics that society, government, university administrators and students themselves are moving away from viewing legal education as a public good which benefits both students and society. Instead, legal education is increasingly being viewed as a purely private good, for consumption by the student in the quest for individual career enhancement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The Spine Functional Index (SFI) is a patient reported outcome measure with sound clinimetric properties and clinical viability for the determination of whole-spine impairment. To date, no validated Turkish version is available. The purpose of this study is to cross-culturally adapted the SFI for Turkish-speaking patients (SFI-Tk) and determine the psychometric properties of reliability, validity and factor structure in a Turkish population with spine musculoskeletal disorders. Methods The SFI English version was culturally adapted and translated into Turkish using a double forward and backward method according to established guidelines. Patients (n = 285, cervical = l29, lumbar = 151, cervical and lumbar region = 5, 73% female, age 45 ± 1) with spine musculoskeletal disorders completed the SFI-Tk at baseline and after a seven day period for test-retest reliability. For criterion validity the Turkish version of the Functional Rating Index (FRI) was used plus the Neck Disability Index (NDI) for cervical patients and the Oswestry Disability Index (ODI) for back patients. Additional psychometric properties were determined for internal consistency (Chronbach’s α), criterion validity and factor structure. Results There was a high degree of internal consistency (α = 0.85, item range 0.80-0.88) and test-retest reliability (r = 0.93, item range = 0.75-0.95). The factor analysis demonstrated a one-factor solution explaining 24.2% of total variance. Criterion validity with the ODI was high (r = 0.71, p < 0.001) while the FRI and NDI were fair (r = 0.52 and r = 0.58, respectively). The SFI-Tk showed no missing responses with the ‘half-mark’ option used in 11.75% of total responses by 77.9% of participants. Measurement error from SEM and MDC90 were respectively 2.96% and 7.12%. Conclusions The SFI-Tk demonstrated a one-factor solution and is a reliable and valid instrument. The SFI-Tk consists of simple and easily understood wording and may be used to assess spine region musculoskeletal disorders in Turkish speaking patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements of aerosol particle number size distributions (15-700 nm), CO and NOx were performed in a bus tunnel, Australia. Daily mean particle size distributions of mixed diesel/CNG (Compressed Natural Gas) buses traffic flow were determined in 4 consecutive measurement days. EFs (Emission Factors) of Particle size distribution of diesel buses and CNG buses were obtained by MLR (Multiple Linear Regression) methods, particle distributions of diesel buses and CNG buses were observed as single accumulation mode and nuclei-mode separately. Particle size distributions of mixed traffic flow were decomposed by two log-normal fitting curves for each 30 minutes interval mean scans, all the mix fleet PSD emission can be well fitted by the summation of two log-normal distribution curves, and these were composed of nuclei mode curve and accumulation curve, which were affirmed as the CNG buses and diesel buses PN emission curves respectively. Finally, particle size distributions of diesel buses and CNG buses were quantified by statistical whisker-box charts. For log-normal particle size distribution of diesel buses, accumulation mode diameters were 74.5~87.5nm, geometric standard deviations were 1.89~1.98. As to log-normal particle size distribution of CNG buses, nuclei-mode diameters were 21~24 nm, geometric standard deviations were 1.27~1.31.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the past several decades there has been a sharp increase in the number of studies focused on the relationship between vision and driving. The intensified attention to this topic has most likely been stimulated by the lack of an evidence basis for determining vision standards for driving licensure and a poor understanding about how vision impairment impacts driver safety and performance. Clinicians depend on the literature on vision and driving to advise visually impaired patients appropriately about driving fitness. Policy makers also depend on the scientific literature in order to develop guidelines that are evidence-based and are thus fair to persons who are visually impaired. Thus it is important for clinicians and policy makers alike to understand how various study designs and measurement methods should be interpreted so that the conclusions and recommendations they make are not overly broad, too narrowly constrained, or even misguided. We offer a methodological framework to guide interpretations of studies on vision and driving that can also serve as a heuristic for researchers in the area. Here, we discuss research designs and general measurement methods for the study of vision as they relate to driver safety, driver performance, and driver-centered (self-reported) outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The purpose of this paper is to examine consumer perceptions of value of financial institutions using social media to interact with consumers; if overall perceived value predicts a consumer’s intention to adopt, and if intention predicts self-reported adoption of social media to interact with a financial institution; and if perceptions of value in using social media to interact with a financial institution changes over time. Design/methodology/approach Self-administered surveys were run at two time points; 2010 and 2014. Data were analyzed using multiple and mediated regressions, and t-tests. Comparisons are made between the two time points. Findings Perceived usefulness, economic value, and social value predicted overall perceived value, which in turn predicted a consumer’s intention to adopt social media to interact with a financial institution. At Time 2, adoption intention predicted self-reported usage behavior. Finally, there were significant differences between perceptions across Time 1 and 2. Research limitations/implications The implications of the research highlight the importance of overall perceived value in the role of adoption intention, and that at Time 2, adoption intention predicted self-reported adoption to read and share content. A reduction in perceptions of value and intentions from Time 1 to Time 2 could be explained by perceptions of technology insecurity. In future studies, the authors recommend examining inhibitors to adoption including hedonic value. Practical implications The findings suggest that consumers will use social media if the sector creates and clearly articulates consumer value from using social media. The sector also needs to address technology security perceptions to increase usage of social media. Originality/value This paper is one of the first to investigate the consumer’s perspective in social media adoption by financial institutions, by exploring the role of value in consumer adoption and usage of social media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM To investigate the number of hypertensive patients, the optometrist is able to identify by routinely taking blood pressure (BP) measurements for patients in "at -risk" groups, and to sample patients' opinions regarding in -office BP measurement. Many of the optometrists in Saudi Arabia practice in optical stores. These stores are wide spread, easily accessible and seldom need appointments. The expanding role of the optometrist as a primary health care provider (PHCP) and the increasing global prevalence of hypertension, highlight the need for an integrated approach towards detecting and monitoring hypertension. METHODS Automated BP measurements were made twice (during the same session) at five selected optometry practices using a validated BP monitor (Omron M6) to assess the number of patients with high BP (HBP) - in at -risk groups -visiting the eye clinic routinely. Prior to data collection, practitioners underwent a two-day training workshop by a cardiologist on hypertension and how to obtain accurate BP readings. A protocol for BP measurement was distributed and retained in all participating clinics. The general attitude towards cardiovascular health of 480 patients aged 37.2 (依12.4)y and their opinion towards in-office BP measurement was assessed using a self -administered questionnaire. RESULTS A response rate of 83.6% was obtained for the survey. Ninety -three of the 443 patients (21.0% ) tested for BP in this study had HBP. Of these, (62 subjects) 67.7% were unaware of their HBP status. Thirty of the 105 subjects (28.6%) who had previously been diagnosed with HBP, still had HBP at the time of this study, and only 22 (73.3%) of these patients were on medication. Also, only 25% of the diagnosed hypertensive patients owned a BP monitor. CONCLUSION Taking BP measurements in optometry practices, we were able to identify one previously undiagnosed patient with HBP for every 8 adults tested. We also identified 30 of 105 previously diagnosed patients whose BP was poorly controlled, twenty-two of whom were on medication. The patients who participated in this study were positively disposed toward the routine measurement of BP by optometrists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper provides insights into salient issues in the development of the Integrated Reporting () Framework, and emerging issues in the implementation of this Framework, with the aim of identifying opportunities for future research. The International Integrated Reporting Council (IIRC) has recently produced a reporting framework for the preparation of a concise, user-oriented corporate report which expands the scope of a company’s reporting using a multiple capitals concept and requires a description of a company’s business model, allowing a better communication of its value creation proposition. To gain international acceptance, the market-based benefits of adopting the framework must be demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background In the emergency department, portable point-of-care testing (POCT) coagulation devices may facilitate stroke patient care by providing rapid International Normalized Ratio (INR) measurement. The objective of this study was to evaluate the reliability, validity, and impact on clinical decision-making of a POCT device for INR testing in the setting of acute ischemic stroke (AIS). Methods A total of 150 patients (50 healthy volunteers, 51 anticoagulated patients, 49 AIS patients) were assessed in a tertiary care facility. The INR's were measured using the Roche Coaguchek S and the standard laboratory technique. Results The interclass correlation coefficient and 95% confidence interval between overall POCT device and standard laboratory value INRs was high (0.932 (0.69 - 0.78). In the AIS group alone, the correlation coefficient and 95% CI was also high 0.937 (0.59 - 0.74) and diagnostic accuracy of the POCT device was 94%. Conclusions When used by a trained health professional in the emergency department to assess INR in acute ischemic stroke patients, the CoaguChek S is reliable and provides rapid results. However, as concordance with laboratory INR values decreases with higher INR values, it is recommended that with CoaguChek S INRs in the > 1.5 range, a standard laboratory measurement be used to confirm the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IT consumerization is both a major opportunity and significant challenge for organizations. However, IS research has hardly discussed the implications for IT management so far. In this paper we address this topic by empirically identifying organizational themes for IT consumerization and conceptually exploring the direct and indirect effects on the business value of IT, IT capabilities, and the IT function. More specifically, based on two case studies, we identify eight organizational themes: consumer IT strategy, policy development and responsibilities, consideration of private life of employees, user involvement into IT-related processes, individualization, updated IT infrastructure, end user support, and data and system security. The contributions of this paper are: (1) the identification of organizational themes for IT consumerization; (2) the proposed effects on the business value of IT, IT capabilities and the IT function, and; (3) combining empirical insights into IT consumerization with managerial theories in the IS discipline.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For this week's Favorites of the Week, Dr. Matthew Rimmer wanted to focus in on some of the specific points that came up in the Congressional hearing on fair use earlier this week. While a bit different than our usual "favorites of the week" post, it's a really fantastic in-depth look at some of the issues, which I'm sure many of you will enjoy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This essay provides a critical assessment of the Fair Use Project based at the Stanford Center for Internet and Society. In evaluating the efficacy of the Fair Use Project, it is worthwhile considering the litigation that the group has been involved in, and evaluating its performance. Part 1 outlines the history of the Stanford Center for Internet and Society, and the aims and objectives of the Fair Use Project. Part 2 considers the litigation in Shloss v. Sweeney over a biography concerning Lucia Joyce, the daughter of the avant-garde literary great, James Joyce. Part 3 examines the dispute over the Harry Potter Lexicon. Part 4 looks at the controversy over the Shepard Fairey poster of President Barack Obama, and the resulting debate with Associated Press. Part 5 of the essay considers the intervention of the Fair Use Project as an amicus curiae in the ‘Column case’. Part 6 explores the participation of the Fair Use Project as an amicus curiae in the litigation over 60 Years Later, an unauthorised literary sequel to J.D. Salinger’s The Catcher in the Rye. Part 7 of the essay investigates the role of the Fair Use project in disputes over copyright law and musical works. Part 8 investigates the role of the Fair Use Project as an advocate in disputes over copyright law, fair use, documentary films, and internet videos. The conclusion has main three arguments. First, it contends that Australia should establish a Fair Use Project to support creative artists in litigation over copyright exceptions. Second, it maintains that Australia should adopt a flexible, open-ended defence of fair use, and draw upon the rich jurisprudence in the United States on the fair use doctrine. Finally, this paper argues that support should be given at an international level to the proposal for a Treaty on Access to Knowledge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To analyse and compare standing thoracolumbar curves in normal weight participants and participants with obesity, using an electromagnetic device, and to analyse the measurement reliability. Material and Methods. Cross-sectional study was carried out. 36 individuals were divided into two groups (normal-weight and participants with obesity) according to their waist circumference. The reference points (T1–T8–L1–L5 and both posterior superior iliac spines) were used to perform a description of thoracolumbar curvature in the sagittal and coronal planes. A transformation from the global coordinate system was performed and thoracolumbar curves were adjusted by fifth-order polynomial equations. The tangents of the first and fifth lumbar vertebrae and the first thoracic vertebra were determined from their derivatives. The reliability of the measurement was assessed according to the internal consistency of the measure and the thoracolumbar curvature angles were compared between groups. Results. Cronbach’s alpha values ranged between 0.824 (95% CI: 0.776–0.847) and 0.918 (95% CI: 0.903–0.949). In the coronal plane, no significant differences were found between groups; however, in sagittal plane, significant differences were observed for thoracic kyphosis. Conclusion. There were significant differences in thoracic kyphosis in the sagittal plane between two groups of young adults grouped according to their waist circumference.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To analyze the ability to discriminate between healthy individuals and individuals with chronic nonspecific low back pain (CNLBP) by measuring the relation between patient-reported outcomes and objective clinical outcome measures of the erector spinae (ES) muscles using an ultrasound during maximal isometric lumbar extension. Design Cross-sectional study with screening and diagnostic tests with no blinded comparison. Setting University laboratory. Participants Healthy individuals (n=33) and individuals with CNLBP (n=33). Interventions Each subject performed an isometric lumbar extension. With the variables measured, a discriminate analysis was performed using a value ≥6 in the Roland and Morris disability questionnaire (RMDQ) as the grouping variable. Then, a logistic regression with the functional and architectural variables was performed. A new index was obtained from each subject value input in the discriminate multivariate analysis. Main Outcome Measures Morphologic muscle variables of the ES muscle were measured through ultrasound images. The reliability of the measures was calculated through intraclass correlation coefficients (ICCs). The relation between patient-reported outcomes and objective clinical outcome measures was analyzed using a discriminate function from standardized values of the variables and an analysis of the reliability of the ultrasound measurement. Results The reliability tests show an ICC value >.95 for morphologic and functional variables. The independent variables included in the analysis explained 42% (P=.003) of the dependent variable variance. Conclusions The relation between objective variables (electromyography, thickness, pennation angle) and a subjective variable (RMDQ ≥6) and the capacity of this relation to identify CNLBP within a group of healthy subjects is moderate. These results should be considered by clinicians when treating this type of patient in clinical practice.