967 resultados para Extraoral Traction Appliances


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chronic rotator cuff tendon tears lead to fatty infiltration and muscle atrophy with impaired physiological functions of the affected muscles. However, the cellular and molecular mechanisms of corresponding pathophysiological processes remain unknown. The purpose of this study was to characterize the expression pattern of adipogenic (PPARgamma, C/EBPbeta) and myogenic (myostatin, myogenin, Myf-5) transcription factors in infraspinatus muscle of sheep after tenotomy, implantation of a tension device, refixation of the tendon, and rehabilitation, reflecting a model of chronic rotator cuff tears. In contrast to human patients, the presented sheep model allows a temporal evaluation of the expression of a given marker in the same individual over time. Semiquantitative RT/PCR analysis of PPARgammaã, myostatin, myogenin, Myf-5, and C/EBPbeta transcript levels was carried out with sheep muscle biopsy-derived total RNA. We found a significantly increased expression of Myf-5 and PPARgamma after tenotomy and a significant change for Myf-5 and C/EBPbeta after continuous traction and refixation. This experimental sheep model allows the molecular analysis of pathomechanisms of muscular changes after rotator cuff tear. The results point to a crucial role of the transcription factors PPARgamma, C/EBPbeta, and Myf-5 in impairment and regeneration of rotator cuff muscles after tendon tears in sheep.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Throughout the years, various treatment modalities have been presented for the treatment of Class II Division 1 malocclusions. The goal of this paper is to present a treatment approach that involves the extraction of the maxillary first molars followed by use of fixed appliances with low-friction brackets. This treatment approach has proven to be an efficient treatment modality for Class II Division 1 malocclusions, especially with noncompliant patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we introduce a cooperative environment between the Interactive Digital TV (IDTV) and home networking with the aim of allowing the interaction between interactive TV applications and the controllers of the in-home appliances in a natural way. More specifically, our proposal consists of merging MHP (Multimedia Home Platform), one of the main standard frameworks for IDTV, with OSGi (Open Service Gateway Initiative), the most widely used open platform to set up Residential Gateways. To overcome the radically different nature of these specifications the function-oriented MHP middleware and the service-oriented OSGi framework , we define a new kind of application, coined as XbundLET. Although this software bridge is suitable to enable the interaction between MHP and OSGi applications in both directions, we concretely focus on exposing our implementation experience in only one direction: from MHP to the OSGi world.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die personalintensive manuelle Durchführung notwendiger Handhabungsaufgaben im Materialfluss ist bedingt durch die oftmals vielfältig auftretenden charakteristischen Eigenschaften der zu behandelnden Stückgutobjekte. Typische Beispiele hierfür sind die Tätigkeiten des Kommissionierens und Sortierens, geprägt durch einen hohen Anteil manueller Tätigkeiten zur Handhabung wie: Vereinzeln, Greifen, Bewegen, Auf- und Abstapeln, Ordnen, Beladen und Ähnliche. Innovative Greifersysteme zur Stückguthandhabung eröffnen neue Möglichkeiten zur weiteren Automatisierung auch in diesem Bereich. Ein Lösungsansatz zur Entwicklung neuer Greifsysteme ist es, gezielt Friktionskräfte in Oberflächenbereiche des zu greifenden Objektes einzubringen und diese für den Handhabungsvorgang z.B. als Haltekräfte zu nutzen. Bei guten Reibwerten und entsprechender Anordnung der Wirkelemente können Objekte auch dann rein reibschlüssig gegriffen werden, wenn deren Oberfläche nur seitlich und von oben zugänglich ist, wie etwa Kartons im Packmusterverbund auf der Palette.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Decentralised controls offer advantages for the implementation as well as the operation of controls of steady conveyors. Such concepts are mainly based on RFID. Due to the reduced expense for appliances and software, however, the plant behaviour cannot be determined as accurately as in centrally controlled systems. This article describes a simulation-based method by which the performances of these two control concepts can easily be evaluated in order to determine the suitability of the decentralised concept.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Successful computer-supported distance education requires that its enabling technologies are accessible and usable anywhere. They should work seamlessly inside and outside the information superhighway, wherever the target learners are located, without obtruding on the learning activity. It has long been recognised that the usability of interactive computer systems is inversely related to the visibility of the implementing technologies. Reducing the visibility of technology is especially challenging in the area of online language learning systems, which require high levels of interactivity and communication along multiple dimensions such as speaking, listening, reading and writing. In this article, the authors review the concept of invisibility as it applies to the design of interactive technologies and appliances. They describe a specialised appliance matched to the requirements for distance second language learning, and report on a successful multi-phase evaluation process, including initial field testing at a Thai open university.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Successful computer-supported distance education requires that its enabling technologies are accessible and usable anywhere. They should work seamlessly inside and outside the information superhighway, wherever the target learners are located, without obtruding on the learning activity. It has long been recognised that the usability of interactive computer systems is inversely related to the visibility of the implementing technologies. Reducing the visibility of technology is especially challenging in the area of online language learning systems, which require high levels of interactivity and communication along multiple dimensions such as speaking, listening, reading and writing. In this article, the authors review the concept of invisibility as it applies to the design of interactive technologies and appliances. They describe a specialised appliance matched to the requirements for distance second language learning, and report on a successful multi-phase evaluation process, including initial field testing at a Thai open university.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Es sollen hochfeste, gewichtreduzierte Zug- und Tragmittel aus hochmodularen (HM) und hochfesten (HT) Fasern validiert und dabei sowohl runde als auch flache, riemenartige Strukturen untersucht werden. Dadurch sind effizientere Fördersysteme und die Überwindung technischer Grenzen möglich. Darüber hinaus soll das Hauptkriterium für ein breites Anwendungsspektrum geschaffen werden: ein anerkanntes, zerstörungsfreies Prüfverfahren, mit dem der Austausch- bzw. Wartungszeitpunkt des textilen Tragmittels bestimmt werden kann. Können die o. g. Punkte erfolgreich bearbeitet werden, erfolgt eine Ausdehnung der textilen Strukturen in den Bereich kraftübertragender Maschinenelemente. Anhand von Feldversuchen in fördertechnischen Anlagen im Bergbau/ Intralogistik soll erstmals der vollständige Nachweis geführt werden, dass derartige textile Strukturen in technischen Anwendungen eingesetzt werden können. Der Nachweis umfasst die Validierung einer Vielzahl von Einzelschwerpunkten wie die Entwicklung einer Endlos-Herstellungstechnologie bzw. Endverbindung, die Tragmitteldimensionierung, die Erbringung von Festigkeitsnachweisen, die Erarbeitung von Vorschriften und die Erprobung der Verfahren zur Zustandsüberwachung.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Energieeffiziente und leistungsfähige Zug- und Tragmittel aus hochmoduligen (HM) und hochfesten (HT) Fasern rücken seit einigen Jahren in den Fokus von Aufzugherstellern und Betreibern. Hauptgrund dafür ist, das die bisher eingesetzten Stahldrahtseile auf Grund ihrer vergleichsweise hohen Eigenmasse an technische Grenzen stoßen. Seile aus hochfesten Polymerfasern haben gegenüber Stahldrahtseilen eine vergleichbare oder sogar höhere Zugfestigkeit und ein vier- bis sechsfach geringeres Gewicht. Um das Potential dieser Fasern optimal auszunutzen, sind sowohl die Anordnung der Fasern als auch die Schmierstoffeinbringung zu untersuchen. Diesbezüglich wurden verschiedenen Seilkonstruktions- und Schmierstoffvarianten entwickelt und im Dauerbiegeversuch validiert.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION The purpose of this study was to examine the overall success of miniscrews inserted in the paramedian palatal region for support of various appliances during orthodontic treatment. METHODS The patients received 1 or 2 miniscrews in the paramedian anterior palate of 8.0-mm length and 1.6-mm diameter placed during orthodontic treatment by the same experienced orthodontist. RESULTS In total, 196 patients (121 girls, 75 boys; median age, 11.7; interquartile range, 3.7) who received 384 miniscrews were evaluated. Two hundred four miniscrews were used with rapid palatal expansion appliances, 136 with appliances for distalization of posterior teeth, and 44 with other appliances, such as transpalatal arches for tooth stabilization. The overall survival of the miniscrews was excellent (97.9%) in the cases examined. Cox regression analysis showed no difference in the overall survival rates of miniscrews loaded with different appliances for sex (hazard ratio, 0.95; 95% confidence interval, 0.71-1.27; P = 0.73) after adjusting for appliance and age. CONCLUSIONS This study shows that miniscrews placed in the paramedian anterior palate for supporting various orthodontic appliances have excellent survival.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Light cure of resin-based adhesives is the mainstay of orthodontic bonding. In recent years, alternatives to conventional halogen lights offering reduced curing time and the potential for lower attachment failure rates have emerged. The relative merits of curing lights in current use, including halogen-based lamps, light-emitting diodes (LEDs), and plasma arc lights, have not been analyzed systematically. In this study, we reviewed randomized controlled trials and controlled clinical trials to assess the risks of attachment failure and bonding time in orthodontic patients in whom brackets were cured with halogen lights, LEDs, or plasma arc systems. METHODS Multiple electronic database searches were undertaken, including MEDLINE, EMBASE, and the Cochrane Oral Health Group's Trials Register, CENTRAL. Language restrictions were not applied. Unpublished literature was searched on ClinicalTrials.gov, the National Research Register, Pro-Quest Dissertation Abstracts, and Thesis database. Search terms included randomized controlled trial, controlled clinical trial, random allocation, double blind method, single blind method, orthodontics, LED, halogen, bond, and bracket. Authors of primary studies were contacted as required, and reference lists of the included studies were screened. RESULTS Randomized controlled trials and clinical controlled trials directly comparing conventional halogen lights, LEDs, or plasma arc systems involving patients with full arch, fixed, or bonded orthodontic appliances (not banded) with follow-up periods of a minimum of 6 months were included. Using predefined forms, 2 authors undertook independent extraction of articles; disagreements were resolved by discussion. The assessment of the risk of bias of the randomized controlled trials was based on the Cochrane Risk of Bias tool. Ten studies met the inclusion criteria; 2 were excluded because of high risk of bias. In the comparison of bond failure risk with halogen lights and plasma arc lights, 1851 brackets were included in both groups. Little statistical heterogeneity was observed in this analysis (I(2) = 4.8%; P = 0.379). There was no statistical difference in bond failure risk between the groups (OR, 0.92; 95% CI, 0.68-1.23; prediction intervals, 0.54, 1.56). Similarly, no statistical difference in bond failure risk was observed in the meta-analysis comparing halogen lights and LEDs (OR, 0.96; 95% CI, 0.64-1.44; prediction intervals, 0.07, 13.32). The pooled estimates from both comparisons were OR, 0.93; 95% CI, 0.74-1.17; and prediction intervals, 0.69, 1.17. CONCLUSIONS There is no evidence to support the use of 1 light cure type over another based on risk of attachment failure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Our objective was to investigate potential associations between maxillary sinus floor extension and inclination of maxillary second premolars and second molars in patients with Class II Division 1 malocclusion whose orthodontic treatment included maxillary first molar extractions. METHODS The records of 37 patients (18 boys, 19 girls; mean age, 13.2 years; SD, 1.62 years) treated between 1998 and 2004 by 1 orthodontist with full Begg appliances were used in this study. Inclusion criteria were white patients with Class II Division 1 malocclusion, sagittal overjet of ≥4 mm, treatment plan including extraction of the maxillary first permanent molars, no missing teeth, and no agenesis. Maxillary posterior tooth inclination and lower maxillary sinus area in relation to the palatal plane were measured on lateral cephalograms at 3 time points: at the start and end of treatment, and on average 2.5 years posttreatment. Data were analyzed for the second premolar and second molar inclinations by using mixed linear models. RESULTS The analysis showed that the second molar inclination angle decreased by 7° after orthodontic treatment, compared with pretreatment values, and by 11.5° at the latest follow-up, compared with pretreatment. There was evidence that maxillary sinus volume was negatively correlated with second molar inclination angle; the greater the volume, the smaller the inclination angle. For premolars, inclination increased by 15.4° after orthodontic treatment compared with pretreatment, and by 8.1° at the latest follow-up compared with baseline. The volume of the maxillary sinus was not associated with premolar inclination. CONCLUSIONS We found evidence of an association between maxillary second molar inclination and surface area of the lower sinus in patients treated with maxillary first molar extractions. Clinicians who undertake such an extraction scheme in Class II patients should be aware of this potential association and consider appropriate biomechanics to control root uprighting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tin is a notable anti-erosive agent, and the biopolymer chitosan has also shown demineralisation-inhibiting properties. Therefore, the anti-erosive/anti-abrasive efficacy of the combination of both compounds was tested under in situ conditions. Twenty-seven volunteers were included in a randomised, double-blind, three-cell crossover in situ trial. Enamel specimens were recessed on the buccal aspects of mandibular appliances, extraorally demineralised (6 × 2 min/day) and intraorally treated with toothpaste slurries (2 × 2 min/day). Within the slurry treatment time, one-half of the specimens received additional intraoral brushing (5 s, 2.5 N). The tested toothpastes included a placebo toothpaste, an experimental NaF toothpaste (1,400 ppm F(-)) and an experimental F/Sn/chitosan toothpaste (1,400 ppm F(-), 3,500 ppm Sn(2+), 0.5% chitosan). The percentage reduction of tissue loss (slurry exposure/slurry exposure + brushing) compared to placebo was 19.0 ± 47.3/21.3 ± 22.4 after use of NaF and 52.5 ± 30.9/50.2 ± 34.3 after use of F/Sn/chitosan. F/Sn/chitosan was significantly more effective than NaF (p ≤ 0.001) and showed good efficacy against erosive and erosive-abrasive tissue loss. This study suggests that the F/Sn/chitosan toothpaste could provide good protection for patients who frequently consume acidic foodstuffs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES It is well known that Sn(2+) is a notable anti-erosive agent. There are indications that biopolymers such as chitosan can enhance the effect of Sn(2+), at least in vitro. However, little information exists about their anti-erosive/anti-abrasive in situ effects. In the present in situ study, the efficacy of Sn(2+)-containing toothpastes in the presence or absence of chitosan was tested. METHODS Ten subjects participated in the randomised crossover study, wearing mandibular appliances with human enamel specimens. Specimens were extraorally demineralised (7 days, 0.5 % citric acid, pH 2.6; 6 × 2 min/day) and intraorally exposed to toothpaste suspensions (2 × 2 min/day). Within the suspension immersion time, one half of the specimens were additionally brushed intraorally with a powered toothbrush (5 s, 2.5 N). Tested preparations were a placebo toothpaste (negative control), two experimental toothpastes (F/Sn = 1,400 ppm F(-), 3,500 ppm Sn(2+); F/Sn/chitosan = 1,400 ppm F(-), 3,500 ppm Sn(2+), 0.5 % chitosan) and an SnF2-containing gel (positive control, GelKam = 3,000 ppm Sn(2+), 1,000 ppm F(-)). Substance loss was quantified profilometrically (μm). RESULTS In the placebo group, tissue loss was 11.2 ± 4.6 (immersion in suspension) and 17.7 ± 4.7 (immersion in suspension + brushing). Immersion in each Sn(2+)-containing suspension significantly reduced tissue loss (p ≤ 0.01); after immersion in suspension + brushing, only the treatments with GelKam (5.4 ± 5.5) and with F/Sn/chitosan (9.6 ± 5.6) significantly reduced loss [both p ≤ 0.05 compared to placebo; F/Sn 12.8 ± 6.4 (not significant)] CONCLUSION Chitosan enhanced the efficacy of the Sn(2+)-containing toothpaste as an anti-erosive/anti-abrasive agent. CLINICAL RELEVANCE The use of Sn(2+)- and chitosan-containing toothpaste is a good option for symptomatic therapy in patients with regular acid impacts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE The aim of the therapy is mechanical and functional stabilization of high dislocated hips with dysplasia coxarthrosis using total hip arthroplasty (THA). INDICATIONS Developmental dysplasia of the hip (DDH) in adults, symptomatic dysplasia coxarthrosis, high hip dislocation according to Crowe type III/IV, and symptomatic leg length inequality. CONTRAINDICATIONS Cerebrospinal dysfunction, muscular dystrophy, apparent disturbance of bone metabolism, acute or chronic infections, and immunocompromised patients. SURGICAL TECHNIQUE With the patient in a lateral decubitus position an incision is made between the anterior border of the gluteus maximus muscle and the posterior border of the gluteus medius muscle (Gibson interval). Identification of the sciatic nerve to protect the nerve from traction disorders by visual control. After performing trochanter flip osteotomy, preparation of the true actetabulum if possible. Implantation of the reinforcement ring, preparation of the femur and if necessary for mobilization, resection until the trochanter minor. Test repositioning under control of the sciatic nerve. Finally, refixation of the trochanteric crest. POSTOPERATIVE MANAGEMENT During hospital stay, intensive mobilization of the hip joint using a continuous passive motion machine with maximum flexion of 70°. No active abduction and passive adduction over the body midline. Maximum weight bearing 10-15 kg for 8 weeks, subsequently, first clinical and radiographic follow-up and deep venous thrombosis prophylaxis until full weight bearing. RESULTS From 1995 to 2012, 28 THAs of a Crow type IV high hip-dislocation were performed in our institute. Until now 14 patients have been analyzed during a follow-up of 8 years in 2012. Mid-term results showed an improvement of the postoperative clinical score (Merle d'Aubigné score) in 86 % of patients. Good to excellent results were obtained in 79 % of cases. Long-term results are not yet available. In one case an iatrogenic neuropraxia of the sciatic nerve was observed and after trauma a redislocation of the arthroplasty appeared in another case. In 2 cases an infection of the THA appeared 8 and 15 months after index surgery. No pseudoarthrosis of the trochanter or aseptic loosening was noticed.