957 resultados para Evaluation methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: From February 2001 to February 2002, 946 patients with advanced GI stromal tumors (GISTs) treated with imatinib were included in a controlled EORTC/ISG/AGITG (European Organisation for Research and Treatment of Cancer/Italian Sarcoma Group/Australasian Gastro-Intestinal Trials Group) trial. This analysis investigates whether the response classification assessed by RECIST (Response Evaluation Criteria in Solid Tumors), predicts for time to progression (TTP) and overall survival (OS). PATIENTS AND METHODS: Per protocol, the first three disease assessments were done at 2, 4, and 6 months. For the purpose of the analysis (landmark method), disease response was subclassified in six categories: partial response (PR; > 30% size reduction), minor response (MR; 10% to 30% reduction), no change (NC) as either NC- (0% to 10% reduction) or NC+ (0% to 20% size increase), progressive disease (PD; > 20% increase/new lesions), and subjective PD (clinical progression). RESULTS: A total of 906 patients had measurable disease at entry. At all measurement time points, complete response (CR), PR, and MR resulted in similar TTP and OS; this was also true for NC- and NC+, and for PD and subjective PD. Patients were subsequently classified as responders (CR/PR/MR), NC (NC+/NC-), or PD. This three-class response categorization was found to be highly predictive of further progression or survival for the first two measurement points. After 6 months of imatinib, responders (CR/PR/MR) had the same survival prognosis as patients classified as NC. CONCLUSION: RECIST perfectly enables early discrimination between patients who benefited long term from imatinib and those who did not. After 6 months of imatinib, if the patient is not experiencing PD, the pattern of radiologic response by tumor size criteria has no prognostic value for further outcome. Imatinib needs to be continued as long as there is no progression according to RECIST.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To develop a provisional definition for the evaluation of response to therapy in juvenile dermatomyositis (DM) based on the Paediatric Rheumatology International Trials Organisation juvenile DM core set of variables. METHODS: Thirty-seven experienced pediatric rheumatologists from 27 countries achieved consensus on 128 difficult patient profiles as clinically improved or not improved using a stepwise approach (patient's rating, statistical analysis, definition selection). Using the physicians' consensus ratings as the "gold standard measure," chi-square, sensitivity, specificity, false-positive and-negative rates, area under the receiver operating characteristic curve, and kappa agreement for candidate definitions of improvement were calculated. Definitions with kappa values >0.8 were multiplied by the face validity score to select the top definitions. RESULTS: The top definition of improvement was at least 20% improvement from baseline in 3 of 6 core set variables with no more than 1 of the remaining worsening by more than 30%, which cannot be muscle strength. The second-highest scoring definition was at least 20% improvement from baseline in 3 of 6 core set variables with no more than 2 of the remaining worsening by more than 25%, which cannot be muscle strength (definition P1 selected by the International Myositis Assessment and Clinical Studies group). The third is similar to the second with the maximum amount of worsening set to 30%. This indicates convergent validity of the process. CONCLUSION: We propose a provisional data-driven definition of improvement that reflects well the consensus rating of experienced clinicians, which incorporates clinically meaningful change in core set variables in a composite end point for the evaluation of global response to therapy in juvenile DM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: Contribution of 3-phase 18F-fluorocholine PET/CT in suspected prostate cancer recurrence at early rise of PSA. PATIENTS, METHODS: Retrospective analysis was performed in 47 patients after initial treatment with radiotherapy (n=30) or surgery (n=17). Following CT, 10 minutes list-mode PET acquisition was done over the prostate bed after injection of 300 MBq of 18F-fluorocholine. Three timeframes of 3 minutes each were reconstructed for analysis. All patients underwent subsequent whole body PET/CT. Delayed pelvic PET/CT was obtained in 36 patients. PET/CT was interpreted visually by two observers and SUVmax determined for suspicious lesions. Biopsies were obtained from 13 patients. RESULTS: Biopsies confirmed the presence of cancer in 11 of 13 patients with positive PET for a total of 15 local recurrences in which average SUVmax increased during 14 minutes post injection and marginally decreased in delayed scanning. Conversely inguinal lymph nodes with mild to moderate metabolic activity on PET showed a clearly different pattern with decreasing SUVmax on dynamic images. Three-phase PET/CT contributed to the diagnostic assessment of 10 of 47 patients with biological evidence of recurrence of cancer. It notably allowed the discrimination of confounding blood pool or urinary activity from suspicious hyperactivities. PET/CT was positive in all patients with PSA>or=2 ng/ml (n=34) and in 4/13 patients presenting PSA values<2 ng/ml. CONCLUSION: 18F-fluorocholine 3-phase PET/CT showed a progressively increasing SUVmax in biopsy confirmed cancer lesions up to 14 minutes post injection while decreasing in inguinal lymph nodes interpreted as benign. Furthermore, it was very useful in differentiating local recurrences from confounding blood pool and urinary activity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Of the approximately 25,000 bridges in Iowa, 28% are classified as structurally deficient, functionally obsolete, or both. Because many Iowa bridges require repair or replacement with a relatively limited funding base, there is a need to develop new bridge materials that may lead to longer life spans and reduced life-cycle costs. In addition, new and effective methods for determining the condition of structures are needed to identify when the useful life has expired or other maintenance is needed. Due to its unique alloy blend, high-performance steel (HPS) has been shown to have improved weldability, weathering capabilities, and fracture toughness than conventional structural steels. Since the development of HPS in the mid-1990s, numerous bridges using HPS girders have been constructed, and many have been economically built. The East 12th Street Bridge, which replaced a deteriorated box girder bridge, is Iowa’s first bridge constructed using HPS girders. The new structure is a two-span bridge that crosses I-235 in Des Moines, Iowa, providing one lane of traffic in each direction. A remote, continuous, fiber-optic based structural health monitoring (SHM) system for the bridge was developed using off-the-shelf technologies. In the system, sensors strategically located on the bridge collect raw strain data and then transfer the data via wireless communication to a gateway system at a nearby secure facility. The data are integrated and converted to text files before being uploaded automatically to a website that provides live strain data and a live video stream. A data storage/processing system at the Bridge Engineering Center in Ames, Iowa, permanently stores and processes the data files. Several processes are performed to check the overall system’s operation, eliminate temperature effects from the complete strain record, compute the global behavior of the bridge, and count strain cycles at the various sensor locations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The manipulation of DNA is routine practice in botanical research and has made a huge impact on plant breeding, biotechnology and biodiversity evaluation. DNA is easy to extract from most plant tissues and can be stored for long periods in DNA banks. Curation methods are well developed for other botanical resources such as herbaria, seed banks and botanic gardens, but procedures for the establishment and maintenance of DNA banks have not been well documented. This paper reviews the curation of DNA banks for the characterisation and utilisation of biodiversity and provides guidelines for DNA bank management. It surveys existing DNA banks and outlines their operation. It includes a review of plant DNA collection, preservation, isolation, storage, database management and exchange procedures. We stress that DNA banks require full integration with existing collections such as botanic gardens, herbaria and seed banks, and information retrieval systems that link such facilities, bioinformatic resources and other DNA banks. They also require efficient and well-regulated sample exchange procedures. Only with appropriate curation will maximum utilisation of DNA collections be achieved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Each winter, the Iowa Department of Transportation (Iowa DOT) maintenance operators are primarily responsible for plowing snow off federal and state roads. Drivers typically work long shifts under treacherous conditions. In addition to properly navigating the vehicle, drivers are required to operate several plowing mechanisms simultaneously, such as plow controls and salt sprayers. However, operators have few opportunities during the year to practice and refine their skills. An ideal training program would provide operators with the opportunity to practice these skills under realistic yet safe conditions, as well as provide basic training to novice or less-experienced operators. Recent technological advancements have made driving simulators a desirable training and research tool. This literature review discusses much of the recent research establishing simulator fidelity and espousing its applicability. Additionally, this report provides a summary of behavioral and eye tracking research involving driving simulators. Other research topics include comparisons between novice and expert drivers’ behavioral patterns, methods for avoiding cybersickness in virtual environments, and a synopsis of current personality measures with respect to job performance and driving performance. This literature review coincides with a study designed to examine the effectiveness of virtual reality snowplow simulator training for current maintenance operators, using the TranSim VS III truck and snowplow simulator recently purchased by the Iowa DOT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To assess the digital educational technology interface Caring for the sensory environment in the neonatal unit: noise, lighting and handling based on ergonomic criteria. METHODS Descriptive study, in which we used the guidelines and ergonomic criteria established by ISO 9241-11 and an online Likert scale instrument to identify problems and interface qualities. The instrument was built based on Ergolist, which follows the criteria of ISO 9141-11. There were 58 undergraduate study participants from the School of Nursing of Ribeirao Preto, University of Sao Paulo, who attended the classes about neonatal nursing content. RESULTS All items were positively evaluated by more than 70% of the sample. CONCLUSION Educational technology is appropriate according to the ergonomic criteria and can be made available for teaching nursing students.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two main approaches are commonly used to empirically evaluate linear factor pricingmodels: regression and SDF methods, with centred and uncentred versions of the latter.We show that unlike standard two-step or iterated GMM procedures, single-step estimatorssuch as continuously updated GMM yield numerically identical values for prices of risk,pricing errors, Jensen s alphas and overidentifying restrictions tests irrespective of the modelvalidity. Therefore, there is arguably a single approach regardless of the factors being tradedor not, or the use of excess or gross returns. We illustrate our results by revisiting Lustigand Verdelhan s (2007) empirical analysis of currency returns.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we explore the effects of the minimum pension program on welfare andretirement in Spain. This is done with a stylized life-cycle model which provides a convenient analytical characterization of optimal behavior. We use data from the Spanish Social Security to estimate the behavioral parameters of the model and then simulate the changes induced by the minimum pension in aggregate retirement patterns. The impact is substantial: there is threefold increase in retirement at 60 (the age of first entitlement) with respect to the economy without minimum pensions, and total early retirement (before or at 60) is almost 50% larger.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Electrical bioimpedance spectroscopy (BIS) allows the evaluation of limb extracellular fluid (R0) and total fluid (Rinf). BIS could facilitate post-surgical oedema evaluation after total knee arthroplasty (TKA), as it is easily performed and is non-invasive. However, neither its applicability in this context nor the influence of metallic implants on measurement has been evaluated. The aim of this study was to evaluate the influence of TKA implants on the BIS R0 and Rinf variables used for oedema evaluation. METHOD: This was a prospective non-randomized comparative clinical trial. One oedema-free group of patients with TKA was compared with a group presenting similar characteristics except for the arthroplasty, to assess the influence of the implant on BIS measurement in the absence of oedema. The TKA group included 15 patients who had undergone surgery more than a year previously, and the control group included 19 patients awaiting TKA surgery. Volume and perimeter measurements served as reference criterions. The lower limb percentage differences for BIS, knee perimeter and volume were calculated. The significance of differences between groups was calculated for all measurement methods, using the Mann-Whitney test. The setting was a Department of Orthopedic Surgery and Traumatology in a university hospital. RESULTS: The differences between groups were not significant for R0, Rinf, volume and perimeter. R0 showed the smallest mean difference in limb percentage difference between groups [means (SD): TKA 3.98 (8.09), controls 3.97 (5.16)]. CONCLUSIONS: The lower-leg percentage difference in the TKA group is comparable with that of healthy subjects. R0 can be used for oedema evaluation following TKA surgery, as there was no sign of alteration from the metallic implant. These findings indicate the potential for early oedema evaluation after TKA. More research is warranted to extensively validate the application of BIS for oedema evaluation after TKA. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigates the comparative performance of five small areaestimators. We use Monte Carlo simulation in the context of boththeoretical and empirical populations. In addition to the direct andindirect estimators, we consider the optimal composite estimator withpopulation weights, and two composite estimators with estimatedweights: one that assumes homogeneity of within area variance andsquare bias, and another one that uses area specific estimates ofvariance and square bias. It is found that among the feasibleestimators, the best choice is the one that uses area specificestimates of variance and square bias.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT: Iron deficiency without anemia (IDWA) is related to adverse symptoms that can be relieved by supplementation. Since a blood donation can induce such an iron deficiency, we investigated the clinical impact of an iron treatment after blood donation. METHODS: One week after donation, we randomly assigned 154 female donors with IDWA aged <50 years to a 4-week oral treatment of ferrous sulfate vs. placebo. The main outcome was the change in the level of fatigue before and after the intervention. Also evaluated were aerobic capacity, mood disorder, quality of life, compliance and adverse events. Biological markers were hemoglobin and ferritin. RESULTS: Treatment effect from baseline to 4 weeks for hemoglobin and ferritin were 5.2 g/L (p < 0.01) and 14.8 ng/mL (p < 0.01) respectively. No significant clinical effect was observed for fatigue (-0.15 points, 95% confidence interval -0.9 to 0.6, p = 0.697) or for other outcomes. Compliance and interruption for side effects was similar in both groups. Additionally, blood donation did not induce overt symptoms of fatigue in spite of the significant biological changes it produces. CONCLUSIONS: These data are valuable as they enable us to conclude that donors with IDWA after a blood donation would not clinically benefit from iron supplementation. Trial registration: NCT00689793.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To assess the efficacy of a topical cyclosporine A (CsA), water-soluble prodrug, for promoting the survival of allogenic rat corneal grafts after penetrating keratoplasty (PKP). METHODS: Corneas of Brown-Norway rats (donors) were transplanted to Lewis rats (recipients). Transplanted rats were divided in three treatment groups: group I (PBS) and group II (0.26% Debio088) received drops five times per day. Group III received a daily intramuscular CsA injection (10 mg/kg/day). Blood CsA concentrations were measured on days 2 and 14. On day 4, 10, 13 after PKP, grafts were scored for corneal transparency, edema and extent of neovascularization. An opacity score of greater than or equal to 3 was considered as a nonreversible graft rejection process. On day 14, the experimental eyes were processed for histology. RESULTS: On day 13, 12 of the 18 corneal transplants (67%) in group I showed irreversible graft rejection. Three of 18 transplants (19%) in group II and 5 of 16 transplants (28%) in group III showed irreversible graft rejection (p=0.013/p=0.019, OR=0.14/0.06 versus vehicle). Each mean clinical score for edema, opacity, and neovessels in group II were significantly lower than those of the grafts in group I (respectively p=0.010, p=0.013, p=0.024) and III except for neovessels (respectively p=0.002, p=0.001, p=0.057). Histology confirmed the clinical results. The mean CsA blood levels for groups II and III were, respectively 54+/-141 mug/l and 755+/-319 mug/l on day 2 and 14+/-34 mug/l and 1318+/-463 mug/l on day 14. CONCLUSIONS: Debio088 CsA prodrug drops given five times daily are as effective as intramuscular injection of 10 mg/kg/day for the prevention of acute corneal graft rejection in rats.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the results of Muller's muscle-conjunctival resection for correction of blepharoptosis and to discuss the advantages of this procedure. METHODS: 38 patients (39 eyelids) were submitted to Muller's muscle-conjunctival resection. Blepharoptosis varied from 1.0 mm to 3.0 mm (mean: 2.0 mm). The amount of eyelid elevation produced by phenylephrine guided the amount of tissue to be resected. RESULT: 33 eyelids (85%) treated with this procedure were cosmetically acceptable. CONCLUSIONS: Muller's muscle-conjunctival resection procedure is a relatively simple technique for blepharoptosis, with good levator function and positive 10% phenylephrine test. The advantages are: preservation of tarsus and predictable results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Many countries used the PGMI (P=perfect, G=good, M=moderate, I=inadequate) classification system for assessing the quality of mammograms. Limits inherent to the subjectivity of this classification have been shown. Prior to introducing this system in Switzerland, we wanted to better understand the origin of this subjectivity in order to minimize it. Our study aimed at identifying the main determinants of the variability of the PGMI system and which criteria are the most subjected to subjectivity. Methods and Materials: A focus group composed of 2 experienced radiographers and 2 radiologists specified each PGMI criterion. Ten raters (6 radiographers and 4 radiologists) evaluated twice a panel of 40 randomly selected mammograms (20 analogic and 20 digital) according to these specified PGMI criteria. The PGMI classification was assessed and the intra- and inter-rater reliability was tested for each professional group (radiographer vs radiologist), image technology (analogic vs digital) and PGMI criterion. Results: Some 3,200 images were assessed. The intra-rater reliability appears to be weak, particularly in respect to inter-rater variability. Subjectivity appears to be largely independent of the professional group and image technology. Aspects of the PGMI classification criteria most subjected to variability were identified. Conclusion: Post-test discussions enabled to specify more precisely some criteria. This should reduce subjectivity when applying the PGMI classification system. A concomitant, important effort in training radiographers is also necessary.