863 resultados para Controlled immobilization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study describes the development of amperometric sensors based on poly(allylamine hydrochloride) (PAH) and lutetium bisphthalocyanine (LuPc(2)) films assembled using the Layer-by-Layer (LbL) technique. The films have been used as modified electrodes for catechol quantification. Electrochemical measurements have been employed to investigate the catalytic properties of the LuPc(2) immobilized in the LbL films. By chronoamperometry, the sensors present excellent sensitivity (20 nA mu M(-1)) in a wide linear range (R(2) = 0.994) up to 900 mu M and limit of detection (s/n = 3) of 37.5 x 10(-8) M for catechol. The sensors have good reproducibility and can be used at least for ten times. The work potential is +0.3 V vs. saturated calomel electrode (SCE). In voltammetry measurements, the calibration curve shows a good linearity (R(2) = 0.992) in the range of catechol up to 500 mu M with a sensitivity of 90 nA mu M(-1) and LD of 8 mu M. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In chemical analyses performed by laboratories, one faces the problem of determining the concentration of a chemical element in a sample. In practice, one deals with the problem using the so-called linear calibration model, which considers that the errors associated with the independent variables are negligible compared with the former variable. In this work, a new linear calibration model is proposed assuming that the independent variables are subject to heteroscedastic measurement errors. A simulation study is carried out in order to verify some properties of the estimators derived for the new model and it is also considered the usual calibration model to compare it with the new approach. Three applications are considered to verify the performance of the new approach. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Artificial vesicles or liposomes composed of lipid bilayers have been widely exploited as building blocks for artificial membranes, in attempts to mimic membrane interaction with drugs and proteins and to investigate drug delivery processes. In this study we report on the immobilization of liposomes of 1,2-dipalmitoyi-sn-Glycero-3-[Phospho-rac-(1-glycerol)] (Sodium Salt) (DPPG) in layer-by-layer (LbL) films, alternated with poly (amidoamine) G4 (PAMAM) dendrimer layers. The average size of the liposomes in solution was 120 nm as determined by dynamic light scattering, with their spherical shape being inferred from scanning electron microscopy (SEM) in cast films. LbL films containing up to 20 PAMAM/DPPG bilayers were assembled onto glass and/or silicon wafer substrates. The growth of the multilayers was achieved by alternately immersing the substrates into the PAMAM and DPPG solutions for 5 and 10 min, respectively. The formation of PAMAM/DPPG liposome multilayers and its ability to interact with BSA were confirmed by Fourier transform infrared spectroscopy (FTIR). The structural features and film thickness were obtained using X-ray diffraction and surface plasmon resonance (SPR). (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper outlines the results obtained with biosensors designed for urea amperometric detection. The incorporation of urease into a bipolymeric substrate consisting of poly(pyrrole) and poly(5-amino-1-naphthol) was performed through four different approaches: direct adsorption, entrapment in cellulose acetate layer. cross-linking with glutaraldehyde, and also covalent attachment to the polymeric matrix. Poly(pyrrole) acts as amperometric transducer in these biosensors, while poly(5-amino-1-naphthol) drastically reduces the interference signal of agents such as ascorbic and uric acids. The biosensors containing urease covalently attached to the substrate provided interesting results in terms of sensitivity towards urea (0.50 mu A cm(-2) mmol(-1) L), lifetime (20 days) and short response times, due to the enzyme immobilization method used. All biosensors analyzed showed also a wide linear concentration range (up to 100 mmol L(-1)) and low detection limits (0.22-0.58 mmol L(-1)). (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper describes the immobilization of nanoparticles onto conducting substrates by using both electrostatic layer-by-layer and electrophoretic deposition (EPD) methods. These two techniques were compared in high-performance electrochromic electrodes based on mixed nickel hydroxide nanoparticles. In addition to easy handling, EPD seems to be the most suitable method for the immobilization of nanoparticles, leading to higher electrochromic efficiencies, lower response times and higher stability upon coloration and bleaching cycling. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dynamic atmosphere generator with a naphthalene emission source has been constructed and used for the development and evaluation of a bioluminescence sensor based on the bacteria Pseudomonas fluorescens HK44 immobilized in 2% agar gel (101 cell mL(-1)) placed in sampling tubes. A steady naphthalene emission rate (around 7.3 nmol min(-1) at 27 degrees C and 7.4 mLmin(-1) of purified air) was obtained by covering the diffusion unit containing solid naphthalene with a PTFE filter membrane. The time elapsed from gelation of the agar matrix to analyte exposure (""maturation time"") was found relevant for the bioluminescence assays, being most favorable between 1.5 and 3 h. The maximum light emission, observed after 80 min, is dependent on the analyte concentration and the exposure time (evaluated between 5 and 20 min), but not on the flow rate of naphthalene in the sampling tube, over the range of 1.8-7.4 nmol min(-1). A good linear response was obtained between 50 and 260 nmol L-1 with a limit of detection estimated in 20 nmol L-1 far below the recommended threshold limit value for naphthalene in air. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper deals with the immobilization of redox mediators and proteins onto protected porous silicon surfaces to obtain their direct electrochemical reactions and to retain their bioactivities. This paper shows that MP-11 and viologens are able to establish chemical bonds with 3-aminopropyltriethoxylsilane-modified porous silicon surface. The functionalization of the surfaces have been fully characterized by energy dispersive X-ray analysis (EDX) and X-ray photoelectron spectroscopy (XPS) to examine the immobilization of these mediators onto the solid surface. Amperometric and open circuit potential measurements have shown the direct electron transfer between glucose oxidase and the electrode in the presence of the viologen mediator covalently linked to the 3-aminopropyltriethoxylsilane (APTES)-modified porous silicon surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymeric electroactive blends formed by electropolymerized aniline inside a non-conductive polyacrylamide porous matrix were already shown as suitable materials for the electrocontrolled release of model compounds like safranin. In this paper the intermolecular interactions between the two components of the blend are put in evidence by Raman spectroscopy measurements. Also, in situ optical microscopy was used to follow changes occurring in the polyaniline/polyacrylamide blend during pyrocathecol violet release tests. These two sets of experiments show the possibility of controlling electrochemically the release of both, safranin (a cation) and pyrocathecol violet (an anion) and allow to infer a release mechanism based on the electromechanical properties of the blends explaining the dependence of the release kinetics on the applied potential. Tetracycline release curves for different potentials and pHs are shown and the obtained profiles are in agreement with those expected for a device acting as an electrochemically driven pump due to the artificial muscle properties of the conducting phase of the blends. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Asystematic study on the surface-enhanced Raman scattering (SERS) for 3,6-bi-2-pyridyl-1,2,4,5-tetrazine (bptz) adsorbed onto citrate-modified gold nanoparticles (cit-AuNps) was carried out based on electronic and vibrational spectroscopy and density functional methods. The citrate/bptz exchange was carefully controlled by the stepwise addition of bptz to the cit-AuNps, inducing flocculation and leading to the rise of a characteristic plasmon coupling band in the visible region. Such stepwise procedure led to a uniform decrease of the citrate SERS signals and to the rise of characteristic peaks of bptz, consistent with surface binding via the N heterocyclic atoms. In contrast, single addition of a large amount of bptz promoted complete aggregation of the nanoparticles, leading to a strong enhancement of the SERS signals. In this case, from the distinct Raman profiles involved, the formation of a new SERS environment became apparent, conjugating the influence of the local hot spots and charge-transfer (CT) effects. The most strongly enhanced vibrations belong to a(1) and b(2) representations, and were interpreted in terms of the electromagnetic and the CT mechanisms: the latter involving significant contribution of vibronic coupling in the system. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A carbon-supported binary Pt(3)Sn catalyst has been prepared using a modified polymeric precursor method under controlled synthesis conditions This material was characterized using X-ray diffraction (XRD). and the results indicate that 23% (of a possible 25%) of Sn is alloyed with Pt, forming a dominant Pt(3)Sn phase. Transmission election microscopy (TEM) shows good dispersion of the electrocatalyst and small particle sizes (3 6 nm +/- 1 nm) The polarization curves for a direct ethanol fuel cell using Pt(3)Sn/C as the anode demonstrated Improved performance compared to that of a PtSn/C E-TEK. especially in the intrinsic resistance-controlled and mass transfer regions. This behavior is probably associated with the Pt(3)Sn phase. The maximum power density for the Pt(3)Sn/C electrocatalyst (58 mW cm(-2)) is nearly twice that of a PtSn/C E-TEK electrocatalyst (33 mW cm(-2)) This behavior is attributed to the presence of a mixed Pt(9)Sn and Pt(3)Sn alloy phase in the commercial catalysts (C) 2009 Elsevier B V All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The synthesis and self-assembly of tetragonal phase-containing L1(0)-Fe(55)Pt(45) nanorods with high coercive field is described. The experimental procedure resulted in a tetragonal/cubic phase ratio close to 1:1 for the as-synthesized nanoparticles. Using different surfactant/solvent proportions in the process allowed control of particle morphology from nanospheres to nanowires. Monodisperse nanorods with lengths of 60 +/- 5 nm and diameters of 2-3 nm were self-assembled in a perpendicular oriented array onto a substrate surface using hexadecylamine as organic spacer. Magnetic alignment and properties assigned, respectively, to the shape anisotropy and the tetragonal phase suggest that the self-assembled materials are a strong candidate to solve the problem of random magnetic alignment observed in FePt nanospheres leading to applications in ultrahigh magnetic recording (UHMR) systems capable of achieving a performance of the order of terabits/in(2).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Continuous subcutaneous insulin infusion (CSII) treatment among children with type 1 diabetes is increasing in Sweden. However, studies evaluating glycaemic control in children using CSII show inconsistent results. Omitting bolus insulin doses using CSII may cause reduced glycaemic control among adolescents. The distribution of responsibility for diabetes self-management between children and parents is often unclear and needs clarification. There is much published support for continued parental involvement and shared diabetes management during adolescence. Guided Self-Determination (GSD) is an empowerment-based, person-centred, reflection and problem solving method intended to guide the patient to become self-sufficient and develop life skills for managing difficulties in diabetes self-management. This method has been adapted for adolescents and parents as Guided Self-Determination-Young (GSD-Y). This study aims to evaluate the effect of an intervention with GSD-Y in groups of adolescents starting on insulin pumps and their parents on diabetes-related family conflicts, perceived health and quality of life (QoL), and metabolic control. Here, we describe the protocol and plans for study enrolment. Methods. This study is designed as a randomized, controlled, prospective, multicentre study. Eighty patients between 12-18 years of age who are planning to start CSII will be included. All adolescents and their parents will receive standard insulin pump training. The education intervention will be conducted when CSII is to be started and at four appointments in the first 4 months after starting CSII. The primary outcome is haemoglobin A1c levels. Secondary outcomes are perceived health and QoL, frequency of blood glucose self-monitoring and bolus doses, and usage of carbohydrate counting. The following instruments will be used to evaluate perceived health and QoL: Disabkids, 'Check your health', the Diabetes Family Conflict Scale and the Swedish Diabetes Empowerment Scale. Outcomes will be evaluated within and between groups by comparing data at baseline, and at 6 and 12 months after starting treatment. Results and discussion. In this study, we will assess the effect of starting an insulin pump together with the model of Guided Self-Determination to determine whether this approach leads to retention of improved glycaemic control, QoL, responsibility distribution and reduced diabetes-related conflicts in the family. Trial registration: Current controlled trials: ISRCTN22444034

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Although breast milk has numerous benefits for infants' development, with greater effects in those born preterm (at < 37 gestational weeks), mothers of preterm infants have shorter breastfeeding duration than mothers of term infants. One of the explanations proposed is the difficulties in the transition from a Neonatal Intensive Care Unit (NICU) to the home environment. A person-centred proactive telephone support intervention after discharge from NICU is expected to promote mothers' sense of trust in their own capacity and thereby facilitate breastfeeding. Methods/design: A multicentre randomized controlled trial has been designed to evaluate the effectiveness and cost-effectiveness of person-centred proactive telephone support on breastfeeding outcomes for mothers of preterm infants. Participating mothers will be randomized to either an intervention group or control group. In the intervention group person-centred proactive telephone support will be provided, in which the support team phones the mother daily for up to 14 days after hospital discharge. In the control group, mothers are offered a person-centred reactive support where mothers can phone the breastfeeding support team up to day 14 after hospital discharge. The intervention group will also be offered the same reactive telephone support as the control group. A stratified block randomization will be used; group allocation will be by high or low socioeconomic status and by NICU. Recruitment will be performed continuously until 1116 mothers (I: 558 C: 558) have been included. Primary outcome: proportion of mothers exclusively breastfeeding at eight weeks after discharge. Secondary outcomes: proportion of breastfeeding (exclusive, partial, none and method of feeding), mothers satisfaction with breastfeeding, attachment, stress and quality of life in mothers/partners at eight weeks after hospital discharge and at six months postnatal age. Data will be collected by researchers blind to group allocation for the primary outcome. A qualitative evaluation of experiences of receiving/providing the intervention will also be undertaken with mothers and staff. Discussion: This paper presents the rationale, study design and protocol for a RCT providing person-centred proactive telephone support to mothers of preterm infants. Furthermore, with a health economic evaluation, the cost-effectiveness of the intervention will be assessed. Trial registration: NCT01806480

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Acupuncture is commonly used to reduce pain during labour despite contradictory results. The aim of this study is to evaluate the effectiveness of acupuncture with manual stimulation and acupuncture with combined manual and electrical stimulation (electro-acupuncture) compared with standard care in reducing labour pain. Our hypothesis was that both acupuncture stimulation techniques were more effective than standard care, and that electro-acupuncture was most effective.  Methods: A longitudinal randomised controlled trial. The recruitment of participants took place at the admission to the labour ward between November 2008 and October 2011 at two Swedish hospitals. 303 nulliparous women with normal pregnancies were randomised to: 40 minutes of manual acupuncture (MA), electro-acupuncture (EA), or standard care without acupuncture (SC). Primary outcome: labour pain, assessed by Visual Analogue Scale (VAS). Secondary outcomes: relaxation, use of obstetric pain relief during labour and post-partum assessments of labour pain. The sample size calculation was based on the primary outcome and a difference of 15 mm on VAS was regarded as clinically relevant, this gave 101 in each group, including a total of 303 women.  Results: Mean estimated pain scores on VAS (SC: 69.0, MA: 66.4 and EA: 68.5), adjusted for: treatment, age, education, and time from baseline, with no interactions did not differ between the groups (SC vs MA: mean difference 2.6, 95% confidence interval [CI] -1.7-6.9 and SC vs EA: mean difference 0.6 [95% CI] -3.6-4.8). Fewer number of women in the EA group used epidural analgesia (46%) than women in the MA group (61%) and SC group (70%) (EA vs SC: odds ratio [OR] 0.35; [95% CI] 0.19-0.67).  Conclusions: Acupuncture does not reduce women's experience of labour pain, neither with manual stimulation nor with combined manual and electrical stimulation. However, fewer women in the EA group used epidural analgesia thus indicating that the effect of acupuncture with electrical stimulation may be underestimated. These findings were obtained in a context with free access to other forms of pain relief.