964 resultados para Control loop
Resumo:
This paper studies the performance of integer and fractional order controllers in a hexapod robot with joints at the legs having viscous friction and flexibility. For that objective the robot prescribed motion is characterized in terms of several locomotion variables. The controller performance is analised through the Nyquist stability criterion. A set of model-based experiments reveals the influence of the different controller implementations upon the proposed metrics.
Resumo:
The theory of fractional calculus goes back to the beginning of the theory of differential calculus, but its application received attention only recently. In the area of automatic control some work was developed, but the proposed algorithms are still in a research stage. This paper discusses a novel method, with two degrees of freedom, for the design of fractional discrete-time derivatives. The performance of several approximations of fractional derivatives is investigated in the perspective of nonlinear system control.
Resumo:
The concept of differentiation and integration to non-integer order has its origins in the seventeen century. However, only in the second-half of the twenty century appeared the first applications related to the area of control theory. In this paper we consider the study of a heat diffusion system based on the application of the fractional calculus concepts. In this perspective, several control methodologies are investigated and compared. Simulations are presented assessing the performance of the proposed fractional-order algorithms.
Resumo:
In this article we describe several methods for the discretization of the differintegral operator sa, where α = u + jv is a complex value. The concept of the conjugated-order differintegral is also introduced, which enables the use of complex-order differintegrals while still producing real-valued time responses and transfer functions. The performance of the resulting approximations is analysed in both the time and frequency domains. Several results are presented that demonstrate its utility in control system design.
Resumo:
Under the pseudoinverse control, robots with kinematical redundancy exhibit an undesirable chaotic joint motion which leads to an erratic behavior. This paper studies the complexity of fractional dynamics of the chaotic response. Fourier and wavelet analysis provides a deeper insight, helpful to know better the lack of repeatability problem of redundant manipulators. This perspective for the study of the chaotic phenomena will permit the development of superior trajectory control algorithms.
Resumo:
This paper shows that a hierarchical architecture, distributing several control actions in growing levels of complexity and using resources of reconfigurable computing, enables one to take into account the ease of future modifications, updates and improvements in robotic applications. An experimental example of a Stewart—Gough platform control (a platform applied as the solution to countless practical problems) is presented using reconfigurable computing. The software and hardware developed are structured in independent blocks. This open architecture implementation allows easy expansion of the system and better adaptation of the platform to its related tasks.
Resumo:
Scope of study: welding operations result in harmful emissions of nanoparticles; the aim of emissions monitorisation is to evaluate exposure levels and to derive protection measures in order to protect exposed workers; however, the traditional approach of comparing measured concentrations with exposure limits cannot be used; but risk levels can be quantified by using Control Banding Strategies.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Electrotécnica e Computadores
Resumo:
El desarrollo de equipos ultrasonográficos portátiles ha permitido incorporar esta técnica a los métodos de detección precoz de la Hidatidosis Humana. En esta experiência fueron efectuadas 690 ecografias, hallándose un 5.51% de imágenes compatibles en población general y un 12.24% en grupos de riesgo (convivientes de casos operados). Se observo una disminución significativa de los porcentajes de infección en el hombre en población general en Ias áreas bajo programa de control, utilizándose Ias encuestas ecográficas para esta determinación. Se concluyó sobre la posibilidad de incorporar la ecografía a los sistemas de vigilância epidemiológica de la hidatidosis humana.
Resumo:
This work was undertaken in the municipality of Pedro de Toledo (São Paulo State, Brazil) in 1987, to clarify aspects related to the transmission levels of Schistosoma mansoni in a human population where the snail host is Biomphalaria tenagophila. Since 1980 a control programme has been undertaken in this municipality. Urban and rural populations (4,719 subjects) were submitted to faecal examinations (Kato-Katz method). The overall prevalence rate was 4.8% being higher in males (6.2%) and also in the rural zone (5.8%). The geometric mean of S. mansoni eggs was 35.1 eggs per gramme of faeces (epg). Approximately 80.0% of the carriers presented less than 100 epg and only 20 individuals (9.0%) eliminated more than half of total eggs. The highest index of potencial contamination (IPC) was in the age group of 5 to 20 years (57.6%). Two thirds of the investigated patients (207) were autochthonous of Pedro de Toledo. The geographical distribution of the carriers showed a clear aggregation of the autochthonous cases and a close association between human contact sites and breeding places of B. tenagophila. This study shows that schistosomiasis subjects were not randomly aggregated, the youngsters should be the main target in the prophylaxis, and the efficacy of the control programme.
Resumo:
This paper develops an energy management system with integration of smart meters for electricity consumers in a smart grid context. The integration of two types of smart meters (SM) are developed: (i) consumer owned SM and (ii) distributor owned SM. The consumer owned SM runs over a wireless platform - ZigBee protocol and the distributor owned SM uses the wired environment - ModBus protocol. The SM are connected to a SCADA system (Supervisory Control And Data Acquisition) that supervises a network of Programmable Logic Controllers (PLC). The SCADA system/PLC network integrates different types of information coming from several technologies present in modern buildings. The developed control strategy implements a hierarchical cascade controller where inner loops are performed by local PLCs, and the outer loop is managed by a centralized SCADA system, which interacts with the entire local PLC network. In order to implement advanced controllers, a communication channel was developed to allow the communication between the SCADA system and the MATLAB software. (C) 2014 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Resumo:
This paper deals with a hierarchical structure composed by an event-based supervisor in a higher level and two distinct proportional integral (PI) controllers in a lower level. The controllers are applied to a variable speed wind energy conversion system with doubly-fed induction generator, namely, the fuzzy PI control and the fractional-order PI control. The event-based supervisor analyses the operation state of the wind energy conversion system among four possible operational states: park, start-up, generating or brake and sends the operation state to the controllers in the lower level. In start-up state, the controllers only act on electric torque while pitch angle is equal to zero. In generating state, the controllers must act on the pitch angle of the blades in order to maintain the electric power around the nominal value, thus ensuring that the safety conditions required for integration in the electric grid are met. Comparisons between fuzzy PI and fractional-order PI pitch controllers applied to a wind turbine benchmark model are given and simulation results by Matlab/Simulink are shown. From the results regarding the closed loop point of view, fuzzy PI controller allows a smoother response at the expense of larger number of variations of the pitch angle, implying frequent switches between operational states. On the other hand fractional-order PI controller allows an oscillatory response with less control effort, reducing switches between operational states. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
This paper is on an onshore variable speed wind turbine with doubly fed induction generator and under supervisory control. The control architecture is equipped with an event-based supervisor for the supervision level and fuzzy proportional integral or discrete adaptive linear quadratic as proposed controllers for the execution level. The supervisory control assesses the operational state of the variable speed wind turbine and sends the state to the execution level. Controllers operation are in the full load region to extract energy at full power from the wind while ensuring safety conditions required to inject the energy into the electric grid. A comparison between the simulations of the proposed controllers with the inclusion of the supervisory control on the variable speed wind turbine benchmark model is presented to assess advantages of these controls. (C) 2015 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).