857 resultados para Continuous improvements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Continuous intraperitoneal insulin infusion (CIPII) with the DiaPort system using regular insulin was compared to continuous subcutaneous insulin infusion (CSII) using insulin Lispro, to investigate the frequency of hypoglycemia, blood glucose control, quality of life, and safety.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coulometric nanotitrations were realized in a microchannel system using a continuous-flow titration technique with a triangle current-time profile. Redox and acid-base titrations were carried out on Fe(II) and nitric acid samples, respectively, with the same nanotitrator device. A linear relation between the concentration and the coulometric current transferred to the solution was found. The advantages of this universally applicable nanotitrator are fast response, low sample volume, high sensitivity, and high reproducibility as well as the convenience of handling an automated analyzer of the flow-through type.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bovine spongiform encephalopathy (BSE) rapid tests and routine BSE-testing laboratories underlie strict regulations for approval. Due to the lack of BSE-positive control samples, however, full assay validation at the level of individual test runs and continuous monitoring of test performance on-site is difficult. Most rapid tests use synthetic prion protein peptides, but it is not known to which extend they reflect the assay performance on field samples, and whether they are sufficient to indicate on-site assay quality problems. To address this question we compared the test scores of the provided kit peptide controls to those of standardized weak BSE-positive tissue samples in individual test runs as well as continuously over time by quality control charts in two widely used BSE rapid tests. Our results reveal only a weak correlation between the weak positive tissue control and the peptide control scores. We identified kit-lot related shifts in the assay performances that were not reflected by the peptide control scores. Vice versa, not all shifts indicated by the peptide control scores indeed reflected a shift in the assay performance. In conclusion these data highlight that the use of the kit peptide controls for continuous quality control purposes may result in unjustified rejection or acceptance of test runs. However, standardized weak positive tissue controls in combination with Shewhart-CUSUM control charts appear to be reliable in continuously monitoring assay performance on-site to identify undesired deviations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Da sich Additive Manufacturing (AM) von traditionellen Produktionsverfahren unterscheidet, entstehen neue Möglichkeiten im Produktdesign und im Supply Chain Setup. Die Auswirkungen der Aufhebung traditionellen Restriktionen im Produktdesign werden unter dem Begriff „Design for Additive Manufacturing“ intensiv diskutiert. In gleicher Weise werden durch AM Restriktionen im traditionellen Supply Chain Setup aufgehoben. Insbesondere sind die folgenden Verbesserungen möglich: Reduktion von Losgrössen und Lieferzeiten, bedarfsgerechte Produktion auf Abruf, dezentrale Produktion, Customization auf Ebene Bauteil und kontinuierliche Weiterentwicklung von Bauteilen. Viele Firmen investieren nicht selbst in die AM Technologien, sondern kaufen Bauteile bei Lieferanten. Um das Potential der AM Supply Chain mit Lieferanten umzusetzen, entstehen die folgenden Anforderungen an AM Einkaufsprozesse. Erstens muss der Aufwand pro Bestellung reduziert werden. Zweitens brauchen AM Nutzer einen direkten Zugang zu den Lieferanten ohne Umweg über die Einkaufsabteilung. Drittens müssen geeignete AM Lieferanten einfach identifiziert werden können. Viertens muss der Wechsel von Lieferanten mit möglichst geringem Aufwand möglich sein. Ein mögliche Lösung sind AM spezifische E-Procurement System um diese Anforderungen zu erfüllen

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate medetomidine as a continuous rate infusion (CRI) in horses in which anaesthesia is maintained with isoflurane and CRIs of ketamine and lidocaine. STUDY DESIGN: Prospective, randomized, blinded clinical trial. ANIMALS: Forty horses undergoing elective surgery. METHODS: After sedation and induction, anaesthesia was maintained with isoflurane. Mechanical ventilation was employed. All horses received lidocaine (1.5 mg kg(-1) initially, then 2 mg kg(-1) hour(-1)) and ketamine (2 mg kg(-1) hour(-1)), both CRIs reducing to 1.5 mg kg(-1) hour(-1) after 50 minutes. Horses in group MILK received a medetomidine CRI of 3.6 mug kg(-1) hour(-1), reducing after 50 minutes to 2.75 mug kg(-1) hour(-1), and horses in group ILK an equal volume of saline. Mean arterial pressure (MAP) was maintained above 70 mmHg using dobutamine. End-tidal concentration of isoflurane (FE'ISO) was adjusted as necessary to maintain surgical anaesthesia. Group ILK received medetomidine (3 mug kg(-1) ) at the end of the procedure. Recovery was evaluated. Differences between groups were analysed using Mann-Whitney, Chi-Square and anova tests as relevant. Significance was taken as p < 0.05. RESULTS: FE'ISO required to maintain surgical anaesthesia in group MILK decreased with time, becoming significantly less than that in group ILK by 45 minutes. After 60 minutes, median (IQR) FE'ISO in MILK was 0.65 (0.4-1.0) %, and in ILK was 1 (0.62-1.2) %. Physiological parameters did not differ between groups, but group MILK required less dobutamine to support MAP. Total recovery times were similar and recovery quality good in both groups. CONCLUSION AND CLINICAL RELEVANCE: A CRI of medetomidine given to horses which were also receiving CRIs of lidocaine and ketamine reduced the concentration of isoflurane necessary to maintain satisfactory anaesthesia for surgery, and reduced the dobutamine required to maintain MAP. No further sedation was required to provide a calm recovery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To examine the influence of a low dose dexmedetomidine infusion on the nociceptive withdrawal reflex and temporal summation in dogs during isoflurane anaesthesia. Study design Prospective experimental blinded cross-over study. Animals Eight healthy mixed breed dogs, body weight Mean +/- SD 26.5 +/- 8.4 kg and age 25 +/- 16 months. Methods Anaesthesia was induced with propofol and maintained with isoflurane (Fe'ISO 1.3%) delivered in oxygen and air. After stabilization, baseline recordings (time 0) were obtained, then a dexmedetomidine bolus (1 mug kg(-1) IV) followed by a continuous rate infusion (1 mug kg(-1) hour(-1) ) or saline placebo were administered. At times 10, 30 and 60 minutes after the initial bolus, electrical stimulations of increasing intensity were applied over the lateral plantar digital nerve, and administered both as single and as repeated stimuli. The resulting reflex responses were recorded using electromyography. Data were analysed using a multivariable linear regression model and a Kruskal Wallis test for single stimulation data, and repeated measures anova and paired t-test for repeated stimulation data. Results The AUC for the stimulus-response curves after single stimulation were similar for both treatments at time 0. At times 10, 30 and 60 the AUCs for the stimulus-response curves were significantly lower with dexmedetomidine treatment than with placebo. Temporal summation was evident in both treatments at times 0, 10, 30 and 60 starting from a stimulation intensity of 10 mA. The magnitude of temporal summation was smaller in dexmedetomidine than in placebo treated dogs at time 10, 30 and 60, but not at time 0. Conclusions During isoflurane anaesthesia, low dose dexmedetomidine suppresses the nociceptive reflex responses after single and repeated electrical stimulation. Clinical relevance This experimental study confirms previous reports on its peri-operative efficacy under clinical conditions, and further indicates that dexmedetomidine might reduce the risk of post-operative chronic pain development.