941 resultados para Computer-assisted image analysis
Resumo:
This work proposes the development of a Computer System for Analysis of Mammograms SCAM, that aids the doctor specialist in the identification and analysis of existent lesions in digital mammograms. The computer system for digital mammograms processing will make use of a group of techniques of Digital Image Processing (DIP), with the purpose of aiding the medical professional to extract the information contained in the mammogram. This system possesses an interface of easy use for the user, allowing, starting from the supplied mammogram, a group of processing operations, such as, the enrich of the images through filtering techniques, the segmentation of areas of the mammogram, the calculation the area of the lesions, thresholding the lesion, and other important tools for the medical professional's diagnosis. The Wavelet Transform will used and integrated into the computer system, with the objective of allowing a multiresolution analysis, thus supplying a method for identifying and analyzing microcalcifications
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: Quantificar, usando o sistema de imagem digital, medidas palpebrais antes e após a cirurgia de blefaroplastia superior. MÉTODOS: Foram avaliadas 18 pálpebras de 9 pacientes atendidas no HC da FMB - UNESP, com idade entre 40 a 75 anos, do sexo feminino, portadoras de dermatocálase. Foram obtidas fotografias das pacientes antes e após 60 dias da blefaroplastia da pálpebra superior. As imagens foram transferidas para um computador e analisadas pelo programa Scion Image Frame Grabber. Os parâmetros avaliados foram: a altura da fenda palpebral em posição primária do olhar, altura do sulco palpebral superior e o ângulo palpebral lateral antes e depois de 60 dias da realização da cirurgia de blefaroplastia superior. RESULTADOS: Após a cirurgia, houve aumento da altura da fenda palpebral e do sulco palpebral superior. Contudo, o ângulo palpebral lateral não se alterou. CONCLUSÃO: A posição palpebral se altera após a blefaroplastia e o processamento de imagens digitais possibilita quantificar estas alterações, mensurando os resultados obtidos com a cirurgia.
Resumo:
Inseminations with frozen-thawed epididymal sperm have resulted in low-pregnancy rates of mares. If fertility of epididymal sperm could be improved, it would help to preserve genetic material from stallions that have suffered severe injuries, been castrated or have died. The aim of the present study was to investigate the effect of different extenders and pre-freezing addition of capacitation media on freezability of epididymal sperm and on storage at 5 degrees C for 24 h. In experiment 1, epididymal sperm samples were diluted and subsequently frozen with three different extenders: Botu-Crio((R)), EDTA-Lactose and INRA-82. Motility analysis using computer assisted sperm analyzer (CASA) demonstrated better motility for sperm in Botu-Crio((R)) than in the other extenders; EDTA-Lactose yielded better motility than INRA-82 on most evaluated parameters. There was no difference in membrane integrity among the studied extenders. From 18 inseminated mares, 12 (66%) were pregnant 15 days after AI with frozen-thawed epididymal sperm showing that Botu-Crio((R)) was able to maintain the fertility potential. In experiment 2, the effect of incubation of epididymal sperm before freezing in three capacitation media (Fert Talp, Sperm Talp, Talp + Progesterone), seminal plasma, or control was tested. Based on post-thaw motility evaluation by CASA, samples incubated in Sperm Talp showed better motility values. There were no differences in plasma or acrosomal membranes or in mitochondrial potential among groups. We concluded that Botu-Crio((R)) was better than the other extenders in the ability to preserve epididymal sperm and that pre-freeze addition of Sperm Talp was also beneficial. (c) 2008 Published by Elsevier B.V.
Resumo:
The aim of the present study was to conduct a critical literature review about the technique of computer-guided surgery in implantology to highlight the indications, purposes, immediate loading of implants and complications, protocol of fabrication, and functioning of virtual planning software. This literature review was based on OLDMEDLINE and MEDLINE databases from 2002 to 2010 using the key words "computer-guided surgery" and "implant-supported prosthesis." Thirty-four studies regarding this topic were found. According to the literature review, it was concluded that the computer-assisted surgery is an excellent treatment alternative for patients with appropriate bone quantity for implant insertion in complete and partially edentulous arches. The Procera Nobel Guide software (Nobel Biocare) was the most common software used by the authors. In addition, the flapless surgery is advantageous for positioning of implants but with accurate indication. Although the computer-guided surgery may be helpful for virtual planning of cases with severe bone resorption, the conventional surgical technique is more appropriate. The surgical guide is important for insertion of the implants regardless of the surgical technique, and the success of immediate loading after computer-guided surgery depends on the accuracy of clinical and/or laboratorial steps.
Resumo:
The aim of this study was to analyze the color alterations performed by the CIE L*a*b* system in the digital imaging of shade guide tabs, which were obtained photographically according to the automatic and manual modes. This study also sought to examine the observers' agreement in quantifying the coordinates. Four Vita Lumin Vaccum shade guide tabs were used: A3.5, B1, B3 and C4. An EOS Canon digital camera was used to record the digital images of the shade tabs, and the images were processed using Adobe Photoshop software. A total of 80 observations (five replicates of each shade according to two observers in two modes, specifically, automatic and manual) were obtained, leading to color values of L*, a* and b*. The color difference (AE) between the modes was calculated and classified as either clinically acceptable or unacceptable. The results indicated that there was agreement between the two observers in obtaining the L*, a* and b* values related to all guides. However, the B1, B3, and C4 shade tabs had AE values classified as clinically acceptable (Delta E = 0.44, Delta E = 2.04 and Delta E = 2.69, respectively). The A3.5 shade tab had a AE value classified as clinically unacceptable (Delta E = 4.17), as it presented higher values for luminosity in the automatic mode (L* = 54.0) than in the manual mode (L* = 50.6). It was concluded that the B1, B3 and C4 shade tabs can be used at any of the modes in digital camera (manual or automatic), which was a different finding from that observed for the A3.5 shade tab.
Resumo:
The objective of this study was to examine the endothelial surface morphology and to perform morphometric analysis of the corneal endothelial cells of Yacare caiman (Caiman yacare) using scanning electron microscopy. Morphometric analysis with regard to polygonality, mean cell area, cell density and coefficient of variation of mean cell area was performed. Cell areas were measured using image analysis software. The normal corneal endothelium of Yacare caiman consisted of polygonal cells of uniform size and shape with interdigitations of the cell borders. Microvilli appeared as protrusions on the cellular surface. The average cell area was 270 +/- 24 mum(2) and the endothelial cell density was 3704 +/- 324 cells/mm(2). The coefficient of variation of cell area was 0.22. This study demonstrates that the Yacare caiman corneal endothelium is similar to those described in other vertebrates.
Resumo:
It has been used a new image analysis method, based on segmentation by shape parameters, for pits morphology examination from Al 2024 aluminum-copper alloy in chloride aqueous solution. Corrosion behavior of this alloys in naturally aerated 3.5% NaCl solution has been investigated through open circuit potential measurements. Afterwards, pits have been characterized by image analysis taking density and size measurements right from corroded surfaces. Morphological investigation has been conducted for profiles, cut orthogonally from mean surface planes, and observed through light microscopy. Image analysis data could demonstrate that pits are wider than deep, evoluting for conical, quasi-conical or irregular shapes. Most pits have presented a quasi-conical morphology, but the wider ones have evoluted to an irregular shape influenced by sub-surface microstructure. Image analysis based on shape segmentation could enhance the differences on morphological behavior. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Studies of DNA damage in gastric epithelial cells of Helicobacter pylori (H. pylori)-infected patients are conflicting, possibly due to different methods used for scoring DNA damage by Comet assay. Therefore, we compared the sensitivity of visual microscopic analysis (arbitrary units-scores and comets%) and image analysis system (tail moment), in the gastric epithelial cells from the antrum and corpus of 122 H. pylori-infected and 32 non-infected patients. The feasibility of cryopreserved peripheral blood lymphocytes and whole-blood cells for DNA damage biomonitoring was also investigated. In the antrum, the levels of DNA damage were significantly higher in H. pylori-infected patients with gastritis than in non-infected patients with normal mucosa, when evaluated by image analysis system, arbitrary units and comets%. In the corpus, the comets% was not sufficiently sensitive to detect the difference between H. pylori-infected patients with gastritis and non-infected patients with normal mucosa. The image analysis system was sensitive enough to detect differences between non-infected patients and H. pylori-infected patients with mild gastritis and between infected patients with moderate and severe gastritis, in both antrum, and corpus, while arbitrary units and comets% were unable to detect these differences. In cryopreserved peripheral blood lymphocytes, the levels of DNA damage (tail moment) were significantly higher in H. pylori-infected patients with moderate and severe gastritis than in non-infected patients. Overall, our results indicate that the image analysis system is more sensitive and adequate to measure the levels of DNA damage in gastric epithelial cells than the other methods assayed. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
A computer program, PhotoLin, written for an IBM-PC-compatible microcomputer is described which detects linear features in aerial photographs, satellite images and topographic maps. The program accepts images saved to PCX files as input and applies noise correction and smoothing filters and thinning routines. The output consists of a skeleton containing the median lines of linear features which can be represented on a map. The branches of the skeleton can be broken into sections of constant length for which the mean orientations are obtained for the preparation of rose diagrams. (C) 2001 Elsevier B.V. Ltd. All rights reserved.
Resumo:
Relief Bragg gratings were recorded on the surface of Ga-Ge-S glass samples by interference of two UV laser beams at 351 nm, Scanning force microscopy was used to perform a 3D image analysis of the resulting surface topography, which shows the superposition of an imprinted grating over the base topography of the glass. An important question regarding the efficiency of the grating is to determine to what extent the base topography reduces the intended coherent scattering of the grating because of its stochastic character. To answer this question we separated both base and grating structures by Fourier filtering, examined both spatial frequency and roughness, and determined the correlation. (C) 2001 Elsevier B.V. B.V. All rights reserved.
Resumo:
We outline a method for registration of images of cross sections using the concepts of The Generalized Hough Transform (GHT). The approach may be useful in situations where automation should be a concern. To overcome known problems of noise of traditional GHT we have implemented a slight modified version of the basic algorithm. The modification consists of eliminating points of no interest in the process before the application of the accumulation step of the algorithm. This procedure minimizes the amount of accumulation points while reducing the probability of appearing of spurious peaks. Also, we apply image warping techniques to interpolate images among cross sections. This is needed where the distance of samples between sections is too large. Then it is suggested that the step of registration with GHT can help the interpolation automation by simplifying the correspondence between points of images. Some results are shown.
Resumo:
Nerve regeneration in a sensory nerve was obtained by the application of different techniques: inside-out vein graft (IOVG group) and standard vein graft (SVG group). These techniques provide a good microenvironment for axon regeneration in motor nerves, but their efficiency for regeneration of sensory nerves is controversial. The saphenous nerve was sectioned and repaired by the inside-out and standard vein graft techniques in rats. After 4, 12, and 20 weeks the graft and the distal stump were observed under electron microscopy. In each studied period, the pattern, diameters, and thickness of the myelin sheaths of the regenerated axons were measured in the graft and distal stump. A comparative study about the regenerated nerve fibers by these two different techniques was performed. Regenerated nerve fibers were prominent in both vein grafts 4 weeks after the surgical procedures. On the other hand, in the distal stump, regenerated nerve fibers were observed only from 12 weeks. In both inside-out vein graft and standard vein graft statistical difference was not observed about the diameters and thickness of the myelinated fibers after 20 weeks. On the other hand, the inside-out group had greater regenerated axon number when compared to the standard group. There is a capillary invasion in both graft and distal stump, especially in the IOVG group. The regenerated axons follow these capillaries all the time like satellite microfascicles. After 20 weeks, the diameters of regenerated fibers repaired by the standard vein graft technique were closer to the normal fibers compared to the inside-out vein graft. On the other hand, the pattern of these regenerated axons was better in the IOVG group.