983 resultados para Compressor valve
Resumo:
PRINCIPLES: Cardiac myxoma is the most commonly diagnosed cardiac tumour. Infection of herpes simplex virus 1 (HSV1) has been postulated to be a factor for this pathologic entity. The aim of the current study was to evaluate the association between HSV 1 and myxoma occurrence.METHODS: Between 1965 and 2005, 70 patients (36 female, mean age: 52.6 years) underwent a resection of myxoma. Selected variables such as hospital mortality and morbidity were studied. A follow-up (FU; mean FU time: 138 +/- 83 months) was obtained (76% complete). Immunohistological studies with monoclonal antibodies against HSV type 1 were performed on tumour biopsies of 40 patients.RESULTS: The mean age was 53 +/- 16 years (range 23 to 84 years, 51% female). Of the investigated population, 31 (44%) were in New York Heart Association (NYHA) class III-IV. Mitral valve stenosis was identified in 14 patients (20%), and in 25 (36%) patients mitral valve was insufficient. During hospitalisation 3 patients suffered from a transient neurological disorder, and in addition to myxoma resection 18 (25.7%) patients had to undergo an additional intervention. The overall survival rate was 91% at 40 years. There was no early postoperative mortality in follow-up, although 4 patients died and 2 patients had been re-operated on for recurrent myxomas after 2 and 9 years. Immunohistology revealed no positive signals for HSV-1 antigens among the 40 analysed cases.CONCLUSION: Complete surgical resection, septum included, was the treatment of choice and mandatory to prevent relapse. Peri-operative morbidity and mortality over 40 years remained low, and no association between HSV infection and occurrence of cardiac myxoma was found.
Resumo:
Atrial septal defects (ASDs) are typically asymptomatic in infancy and early childhood, and elective defect closure is usually performed at ages of 4 to 6 years. Severe pulmonary hypertension (PH) complicating an ASD is seen in adulthood and has only occasionally been reported in small children. A retrospective study was undertaken to evaluate the incidence of severe PH complicating an isolated ASD and requiring early surgical correction. During a 10-year period (1996 to 2006), 355 pediatric patients underwent treatment for isolated ASDs either surgically or by catheter intervention at 2 tertiary referral centers. Two hundred ninety-seven patients had secundum ASDs, and 58 had primum ASDs with mild to moderate mitral regurgitation. Eight infants were found with isolated ASDs (6 with secundum ASDs and 2 with primum ASDs) associated with significant PH, accounting for 2.2% of all patients with ASDs at the centers. These 8 infants had invasively measured pulmonary artery pressures of 50% to 100% of systemic pressure. They were operated in the first year of life and had complicated postoperative courses requiring specific treatment for PH for up to 16 weeks postoperatively. The ultimate outcomes in all 8 infants were good, with persistent normalization of pulmonary pressures during midterm follow-up of up to 60 months (median 28). All other patients with ASDs had normal pulmonary pressures, and the mean age at defect closure was significantly older, at 6.2 years for secundum ASDs and 3.2 years for primum ASDs. In conclusion, ASDs were rarely associated with significant PH in infancy but then required early surgery and were associated with excellent midterm outcomes in these patients.
Resumo:
A 25-year-old male asylum-seeker presented with chest pain, exertional dyspnea, and orthopnea 20 years after the surgical repair of a pentalogy of Fallot. An extracardiac mass compressing the right ventricle was subsequently detected and surgical decompression was performed to relieve the resulting right intraventricular hypertension. At operation, the mass proved to be a coagulase-negative, staphylococcal abscess. In addition, the removal of the mass unmasked a previously nonrecognized pulmonary outflow stenosis that required balloon dilatation and beta-blocker therapy. While infections are known to occur after sternotomy, the formation of an abscess in the anterior mediastinum several years after the intervention appears to be exceptional; this diagnosis came to mind only after the more common complications had been considered, e.g., pseudoaneurysm or pericardial hematoma. To our knowledge, this is the first report of an abscess in the anterior mediastinum that had probably formed over many years following a sternotomy, compressed the right ventricle and masked a pulmonary stenosis.
Resumo:
Aortic stenosis mostly occurs among old-old patients. Once symptoms appear, prognosis is guarded, with 2-year mortality as high as 50%. Transcatheter Aortic Valve Implantation (TAVI) is a new therapeutic option in patients at very high surgical risk, who are mostly older persons. However, TAVI is associated with some complications, and patient selection remains a challenge. Comprehensive geriatric assessment (CGA) identifies patients with medical and functional problems likely to affect the TAVI post-operative course. Collaboration between cardiologists and geriatricians will likely become a standard approach to enhance the assessment of these frail patients and identify those most likely to benefit from TAVI.
Resumo:
OBJECTIVES: To assess the performance of 45F vs. 36F smartcanula in CPB with gravity drainage alone. METHODS: Twenty patients were randomly assigned to two groups receiving for venous drainage a smartcanula which is collapsed over a mandrel for trans-atrial insertion into the inferior vena cava and expanded in situ to either 45F or 36F. RESULTS: Valve replacement/repair was realized in 7/10 and/or CABG in 6/10 for 36F (69+/-13 years) vs. 5/10 and 5/10, respectively, for 45F (63+/-11 years: NS). Body weight and surface area (BSA) were 83+/-9 kg (1.9+/-0.2 m2, max 2.2 m2) for 36F vs. 79+/-6 kg: NS (1.9+/-0.1 m2 (NS), max 2.1 m2) for 45F. Insertion and access orifice diameter (area) was 6 mm and 10 mm (78.5 mm2) for the 36F vs. 6 mm and 13 mm (132 mm2) for the 45F (+69%). Calculated target pump flow (2.4 l/min/m2) was 4.7+/-0.4 l/min for 36F vs. 4.5+/-0.3 l/min for 45F. Achieved pump flow accounted for 5.0+/-0.3 l/min for 36F (8% above target) vs. 4.8+/-0.3 l/min for 45F (8% above target): NS. The water balance during the pump run (clear volume added minus hemofilter and urine output) was 2.2+/-0.3 l for 36F vs. 2.0 l for 45F: NS. CONCLUSION: Due to its 'open' wall (the vena cava provides the seal), its reduced wall thickness (range: 0.0-0.4 mm), and its self-expanding design, the 36F smartcanula requiring a 30F access orifice has sufficient drainage capacity by gravity alone for full CPB in adults with a BSA up to 2.2 mm2.
Resumo:
Despite improvements in health care, the incidence of infective endocarditis has not decreased over the past decades. This apparent paradox is explained by a progressive evolution in risk factors; while classic predisposing conditions such as rheumatic heart disease have been all but eradicated, new risk factors for infective endocarditis have emerged. These include intravenous drug use, sclerotic valve disease in elderly patients, use of prosthetic valves, and nosocomial disease. Newly identified pathogens, which are difficult to cultivate--eg, Bartonella spp and Tropheryma whipplei--are present in selected individuals, and resistant organisms are challenging conventional antimicrobial therapy. Keeping up with these changes depends on a comprehensive approach, allying understanding of the pathogenesis of disease with the development of new drugs for infective endocarditis. Infection by staphylococci and streptococci is being dissected at the molecular level. New ideas for antimicrobial agents are being developed. These novel insights should help redefine preventive and therapeutic strategies against infective endocarditis.
Resumo:
Anticoagulants are a mainstay of cardiovascular therapy, and parenteral anticoagulants have widespread use in cardiology, especially in acute situations. Parenteral anticoagulants include unfractionated heparin, low-molecular-weight heparins, the synthetic pentasaccharides fondaparinux, idraparinux and idrabiotaparinux, and parenteral direct thrombin inhibitors. The several shortcomings of unfractionated heparin and of low-molecular-weight heparins have prompted the development of the other newer agents. Here we review the mechanisms of action, pharmacological properties and side effects of parenteral anticoagulants used in the management of coronary heart disease treated with or without percutaneous coronary interventions, cardioversion for atrial fibrillation, and prosthetic heart valves and valve repair. Using an evidence-based approach, we describe the results of completed clinical trials, highlight ongoing research with currently available agents, and recommend therapeutic options for specific heart diseases.
Resumo:
AIMS: Recent evidence suggests that cardiac progenitor cells (CPCs) may improve cardiac function after injury. The underlying mechanisms are indirect, but their mediators remain unidentified. Exosomes and other secreted membrane vesicles, hereafter collectively referred to as extracellular vesicles (EVs), act as paracrine signalling mediators. Here, we report that EVs secreted by human CPCs are crucial cardioprotective agents. METHODS AND RESULTS: CPCs were derived from atrial appendage explants from patients who underwent heart valve surgery. CPC-conditioned medium (CM) inhibited apoptosis in mouse HL-1 cardiomyocytic cells, while enhancing tube formation in human umbilical vein endothelial cells. These effects were abrogated by depleting CM of EVs. They were reproduced by EVs secreted by CPCs, but not by those secreted by human dermal fibroblasts. Transmission electron microscopy and nanoparticle tracking analysis showed most EVs to be 30-90 nm in diameter, the size of exosomes, although smaller and larger vesicles were also present. MicroRNAs most highly enriched in EVs secreted by CPCs compared with fibroblasts included miR-210, miR-132, and miR-146a-3p. miR-210 down-regulated its known targets, ephrin A3 and PTP1b, inhibiting apoptosis in cardiomyocytic cells. miR-132 down-regulated its target, RasGAP-p120, enhancing tube formation in endothelial cells. Infarcted hearts injected with EVs from CPCs, but not from fibroblasts, exhibited less cardiomyocyte apoptosis, enhanced angiogenesis, and improved LV ejection fraction (0.8 ± 6.8 vs. -21.3 ± 4.5%; P < 0.05) compared with those injected with control medium. CONCLUSION: EVs are the active component of the paracrine secretion by human CPCs. As a cell-free approach, EVs could circumvent many of the limitations of cell transplantation.
Resumo:
The phosphoinositide 3-kinase (PI3K) family has multiple vascular functions, but the specific regulatory isoform supporting lymphangiogenesis remains unidentified. Here, we report that deletion of the Pik3r1 gene, encoding the regulatory subunits p85alpha, p55alpha, and p50alpha impairs lymphatic sprouting and maturation, and causes abnormal lymphatic morphology, without major impact on blood vessels. Pik3r1 deletion had the most severe consequences among gut and diaphragm lymphatics, which share the retroperitoneal anlage, initially suggesting that the Pik3r1 role in this vasculature is anlage-dependent. However, whereas lymphatic sprouting toward the diaphragm was arrested, lymphatics invaded the gut, where remodeling and valve formation were impaired. Thus, cell-origin fails to explain the phenotype. Only the gut showed lymphangiectasia, lymphatic up-regulation of the transforming growth factor-beta co-receptor endoglin, and reduced levels of mature vascular endothelial growth factor-C protein. Our data suggest that Pik3r1 isoforms are required for distinct steps of embryonic lymphangiogenesis in different organ microenvironments, whereas they are largely dispensable for hemangiogenesis.
Resumo:
The pathogenesis of infective endocarditis (IE) is being dissected at the molecular level, which should help redefine new preventive and therapeutic strategies against IE. In spite of improving health care, the incidence of IE has not decreased over the last decades. While classical predisposing conditions such as rheumatic heart disease were being eradicated, new features of IE have emerged. These include IE in intravenous drug users, IE in elderly patients with sclerotic valve disease, prosthetic valve IE and nosocomial IE. The epidemiology, pathogenesis, diagnosis, prevention and treatment of IE are being reviewed in this article.
Resumo:
Three cases are reported of salmonella aortitis observed in three men aged 55, 60 and 48 years, the last of whom had a prosthetic aortic valve and ascending aorta. The microorganisms were S. typhi murium, S. paratyphi B, and S. wien. Despite antibiotic treatment two patients died of perforating aortitis. The third patient developed S. wien gastroenteritis a few days after surgical replacement of the aortic valve and the ascending aorta. Five years later he presented with several bacteremic episodes due to S. wien, which recurred despite several courses of cotrimoxazole treatment. He has now been asymptomatic for over one year under prolonged cotrimoxazole treatment. Since vascular infection may occur following non typhi salmonellosis in 5% of patients over 50, or who have underlying endothelial lesions, the question arises as to whether non typhi S. gastroenteritis should be treated with antibiotics in these high risk patients, in contrast to present recommendations.
Resumo:
BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.
Resumo:
Centrifugal compressors are widely used for example in process industry, oil and gas industry, in small gas turbines and turbochargers. In order to achieve lower consumption of energy and operation costs the efficiency of the compressor needs to be improve. In the present work different pinches and low solidity vaned diffusers were utilized in order to improve the efficiency of a medium size centrifugal compressor. In this study, pinch means the decrement of the diffuser flow passage height. First different geometries were analyzed using computational fluid dynamics. The flow solver Finflo was used to solve the flow field. Finflo is a Navier-Stokes solver. The solver is capable to solve compressible, incompressible, steady and unsteady flow fields. Chien's k-e turbulence model was used. One of the numerically investigated pinched diffuser and one low solidity vaned diffuser were studied experimentally. The overall performance of the compressor and the static pressure distribution before and after the diffuser were measured. The flow entering and leaving the diffuser was measured using a three-hole Cobra-probe and Kiel-probes. The pinch and the low solidity vaned diffuser increased the efficiency of the compressor. Highest isentropic efficiency increment obtained was 3\% of the design isentropic efficiency of the original geometry. It was noticed in the numerical results that the pinch made to the hub and the shroud wall was most beneficial to the operation of the compressor. Also the pinch made to the hub was better than the pinchmade to the shroud. The pinch did not affect the operation range of the compressor, but the low solidity vaned diffuser slightly decreased the operation range.The unsteady phenomena in the vaneless diffuser were studied experimentally andnumerically. The unsteady static pressure was measured at the diffuser inlet and outlet, and time-accurate numerical simulation was conducted. The unsteady static pressure showed that most of the pressure variations lay at the passing frequency of every second blade. The pressure variations did not vanish in the diffuser and were visible at the diffuser outlet. However, the amplitude of the pressure variations decreased in the diffuser. The time-accurate calculations showed quite a good agreement with the measured data. Agreement was very good at the design operation point, even though the computational grid was not dense enough inthe volute and in the exit cone. The time-accurate calculation over-predicted the amplitude of the pressure variations at high flow.
Resumo:
Tässä diplomityössä käsitellään erään tuotekehitysprojektissa tehdyn turbokoneen prototyypin takuumittauksia. Takuumittauksilla on tarkoitus varmistaa alustavasti valmistetun prototyypin toimivuus. Mittauksista saatuja arvoja on lopuksi tarkoitus verrata suunnitteluarvoihin, jolloin nähdäänkuinka hyvin suunnitelmat ja alustavat suunnittelulaskelmat ovat onnistuneet koskien tätä turbokonetta. Työssä esitellään pääpiirteissään laitteen toiminta. Takuumittauksia varten tarpeelli-set mitattavat suureet ja vaihtoehtoiset mittausmenetelmät on esitelty. Lisäksi on suunniteltu mittausjärjestelmä PI-kaavioineen, jolla pystytään saamaan riittävän kat-tava mittaustulos laajuus. Työssä on myös esitelty miten mittaustuloksista saadaan tarvittavat vertailuarvot verrattavaksi alustaviin suunnittelulaskelmiin. Tämä diplomityö on tehty, että alustavat mittaussuunnitelmat olisi valmiina olemassa jotta varsinainen takuumittauslaitteisto pystytään rakentamaan nopeasti turbokoneen prototyypin valmistuttua. Lopuksi saadun mittausotannan käsitteleminen on myös selvempää, koska riittävät teoreettiset perusteet mittausaineiston käsittelemiseen on myös kerätty tähän työhön. Työssä käsiteltävän mittausjärjestelmän pääpaino on virtaus ja lämpöteknisillä mitta-uksilla. Myös sähköteknisiä mittauksia ja turbokoneen rakenteellisen toimivuuden mittauksia on käsitelty tässä työssä. Tässä diplomityö antaa kattavat perustiedot tarvittaviin mittausmenetelmiin ja miten varsinainen mittaustieto saadaan jalostettua vertailtavaan muotoon. Siinä käsitellään myös vaikeuksia joita toimivanmittausjärjestelmän kehittämisessä on otettava huo-mioon.