994 resultados para Commercial Concentration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The discussion based on surfactant cleaning action is commonly used in chemistry classrooms for the comprehension of theoretical concepts related to surface tension and micelle formation. The experimental quantification of surface tension of aqueous solutions of surfactants provides the practical instruments for this discussion. The present paper describes a simplification on the common apparatus employed for the drop-weight method, making the determination of surface tension accessible to any chemistry lab. The surface tension of various liquids and the critical micelle concentration, CMC, of three commercial surfactants were measured with this modified method, and proved to be consistent with literature values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficiency of a new procedure for the digestion of natural waters, based on a microwave-activated photochemical reactor was evaluated in this work. Fluorescence spectra showed a 99% reduction in the emission of a 40 mg L-1 humic acid solution after 15 min of UV irradiation. In the presence of H2O2, only 3 min were necessary to accomplish a reduction of almost 100% in the emission and 6 min to reduce the concentration of dissolved organic carbon by 95%. The copper recovery from synthetic samples containing commercial humic acid, from soil suspensions, as well as from natural waters varied between 91.5 and 106.6%. The digestion of dissolved and unfiltered samples was successfully accomplished in 6 and 12 min, respectively. No contaminations or sample losses were observed. Results of copper speciation in natural waters showed that this metal is predominantly bound to natural ligands. Only 3-6% of the total recoverable copper is present in the labile form.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The spectrophotometric determination of Cd(II) using a flow injection system provided with a solid-phase reactor for cadmium preconcentration and on-line reagent preparation, is described. It is based on the formation of a dithizone-Cd complex in basic medium. The calibration curve is linear between 6 and 300 µg L-1 Cd(II), with a detection limit of 5.4 µg L-1, an RSD of 3.7% (10 replicates in duplicate) and a sample frequency of 11.4 h-1. The proposed method was satisfactorily applied to the determination of Cd(II) in surface, well and drinking waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow system coupled to a tungsten coil atomizer in an atomic absorption spectrometer (TCA-AAS) was developed for As(III) determination in waters, by extraction with sodium diethyldithiocarbamate (NaDDTC) as complexing agent, and by sorption of the As(III)-DDTC complex in a micro-column filled with 5 mg C18 reversed phase (10 µL dry sorbent), followed by elution with ethanol. A complete pre-concentration/elution cycle took 208 s, with 30 s sample load time (1.7 mL) and 4 s elution time (71 µL). The interface and software for the synchronous control of two peristaltic pumps (RUN/ STOP), an autosampler arm, seven solenoid valves, one injection valve, the electrothermal atomizer and the spectrometer Read function were constructed. The system was characterized and validated by analytical recovery studies performed both in synthetic solutions and in natural waters. Using a 30 s pre-concentration period, the working curve was linear between 0.25 and 6.0 µg L-1 (r = 0.9976), the retention efficiency was 94±1% (6.0 µg L-1), and the pre-concentration coefficient was 28.9. The characteristic mass was 58 pg, the mean repeatability (expressed as the variation coefficient) was 3.4% (n=5), the detection limit was 0.058 µg L-1 (4.1 pg in 71 µL of eluate injected into the coil), and the mean analytical recovery in natural waters was 92.6 ± 9.5 % (n=15). The procedure is simple, economic, less prone to sample loss and contamination and the useful lifetime of the micro-column was between 200-300 pre-concentration cycles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work the degradation of aqueous solutions of reactive azo-dyes is reported using a combined reductive/advanced oxidative process based in the H2O2/zero-valent iron system. At optimized experimental conditions (pH 7, H2O2 100 mg L-1, iron 7 g L-1) and using a continuous system containing commercial iron wool, the process afforded almost total discolorization of aqueous solutions of three reactive azo-dyes (reactive orange 16, reactive black 5 and brilliant yellow 3G-P) at a hydraulic retention time of 2.5 min. At these conditions the hydrogen peroxide is almost totally consumed while the released total soluble iron reaches a concentration compatible with the current Brazilian legislation (15 mg L-1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immunoassay techniques provide simple, powerful and inexpensive methods for analysis of environmental contaminants. However, the acceptance of immunoassays is dependent on the clear demonstration of quality and validity compared to more traditional techniques. In this review, primarily, the understanding and the fundamentals of immunoassay methods are given in order to make good use of immunoassays, especially of EIA tests. Special attention is given to the concepts related to the enzyme-linked immunosorbent assay (ELISA) formats, such as inhibition concentration at 50% (IC50), detection limit (LOD), cross-reactivity (CR %). It is also explained why some immunoassays are quantitative methods whereas others can only be used as screening methods. A list of main commercial kits for detection of priority pollutants is given in order to help analysts. Others formats, such as flow-injection immunoassay analysis (FIIA), immunoassay chromatography and immunosensors are also cited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A systematic electrochemical study of a novel cyanide free galvanic plating solution of alkaline zinc is presented. Cell Hull tests and potentiodynamic linear polarization measurements were carried out to evaluate the influence of operational parameters, such as concentration, current efficiency and degradation of additives. The stability of the bath was assessed by a long term test during 40 h at 200 A m-2. The morphology of the coatings was characterized by scanning electron microscopy. The results showed good performance of the plating solution. The cost is similar to that of the commercial cyanide bath and lower than that of the commercial cyanide free bath.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study describes phenol adsorption on commercial active carbon (CAF) under alkaline conditions in the concentration range of 0.01 to 2.08 mmol L-1. Surface characterization has been performed by means of surface area measurements, IR spectroscopy and Boehm titration. The effect of temperature on the adsorption equilibrium isotherm was investigated at 23, 30, 40, 50 and 60 °C. The results showed that adsorption capacity decreased with increasing temperature. The adsorption kinetics and the role of surface characteristics on the adsorption of phenol also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection turbidimetric procedure exploiting merging zones is proposed for determining homatropine methylbromide (HMB) in pharmaceutical preparations. The determination is based on the precipitation reaction of homatropine methylbromide with AgNO3 solution to form a precipitate, which was measured at 410 nm. The analytical curve was linear in the HMB concentration range from 8.0x10-4 to 1.7x10-3 mol L-1, with a detection limit of 9.5x10-5 mol L-1. The recoveries ranged from 94.9 to 104 %, the sampling frequency was 75 h-1 and relative standard deviations were smaller than 2.0 % for solutions containing 1.2x10-3 and 1.5x10-3 mol L-1 HMB (n=10). The results obtained for commercial formulations using the FIA procedure were in good agreement with those obtained by using a comparative method (r= 0.9983).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work commercial filters papers were organomodified with tetraethylorthosilicate (TEOS) and 3-aminopropyltriethoxysilane (3-APTS), aiming at the development of a new analytical procedure for in-situ speciation of labile and inert metal species in aquatic systems. Parameters that exert influence on the metal lability such as pH, chelating time, concentration and characteristics of the organic matter were studied in the laboratory using tests for metal recuperation. The results showed slower kinetics for Cu ion than for Ni, Mn and Cd in the absence of aquatic humic substances (AHS). The relative lability observed for complexed metals in aquatic humic substances using organomodified filter papers was Cu>>Cd>Ni>Mn. The pH values, structural characteristics and concentration of AHS exert strong influence on the lability of the metals. The results obtained showed that the utilization of organomodified filter papers can be an interesting and promising alternative for in situ characterization of metal lability in aquatic systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasuodatus on tehokas entsyymiliuosten konsentrointi- ja puhdistusmenetelmä. Prosessin ongelmana on kuitenkin kalvojen likaantumisesta johtuva suodatuksen aikainen vuon pienentyminen ja kalvojen hankala puhdistaminen. Oikeilla kalvovalinnoilla ja optimaalisilla pesustrategioilla voidaan suodatus- ja pesuaikoja lyhentää ja nain parantaa suodatusprosessin tehokkuutta ja tuotteen laatua. Työn kirjallisessa osassa on käsitelty entsyymiliuosten ja polymeerikalvojen suodatusprosessiin vaikuttavia ominaisuuksia. Työssä on esitelty myös pesuaineiden ja pesukemikaalien ominaisuuksia sekä pesuprosessiin vaikuttavia tekijöitä. Työn kokeellinen osa koostui kahdesta osasta. Työn ensimmäisessä osassa etsittiin entsyymiliuosten ultrasuodatusprosessiin sopivaa kalvoa vertailemalla kalvojen permeabiliteetteja, hydrofiilisyytta, varausta ja peseytyvyyttä. Suodatuksissa käytettiin kahta Roal Oy:n tuottamaa entsyymiliuosta ja suodatukset tehtiin DSS Labstak M20-laitteistolla. Työn toisen osan tarkoituksena oli etsiä entsyymiliuosten suodatuksessa käytettävien kalvojen likaantumisen syyt sekä tehokas puhdistusaine kalvojen pesuun. Tehokasta pesuainetta etsittiin liotuskokeilla ja laboratoriomittakaavan poikkivirtauslaitteistolla. Analysointeja tehtiin muun muassa FTIR- spektroskoopilla, vuomittauksilla, pyyhkäisyelektronimikroskoopilla ja kontaktikulmamittauksilla. Entsyymiliuosten suodatuksiin sopivan kalvon etsinnässä testattujen kalvojen välillä oli suuria eroja niin permeabiliteeteissa kuin likaantumisessa ja puhdistumisessa, mutta mikään kalvoista ei erottunut ylivoimaisesti parhaaksi. Pesuaineista kaupalliset membraanien puhdistukseen tarkoitetut emäksiset pesuaineet osoittautuivat tehokkaimmiksi lian poistajiksi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the artificial neural networks (ANN) and partial least squares (PLS) regression were applied to UV spectral data for quantitative determination of thiamin hydrochloride (VB1), riboflavin phosphate (VB2), pyridoxine hydrochloride (VB6) and nicotinamide (VPP) in pharmaceutical samples. For calibration purposes, commercial samples in 0.2 mol L-1 acetate buffer (pH 4.0) were employed as standards. The concentration ranges used in the calibration step were: 0.1 - 7.5 mg L-1 for VB1, 0.1 - 3.0 mg L-1 for VB2, 0.1 - 3.0 mg L-1 for VB6 and 0.4 - 30.0 mg L-1 for VPP. From the results it is possible to verify that both methods can be successfully applied for these determinations. The similar error values were obtained by using neural network or PLS methods. The proposed methodology is simple, rapid and can be easily used in quality control laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the use of an optical fiber sensor to measure the soybean oil concentration in samples obtained from the mixture of pure biodiesel and commercial soybean oil. The operation of the device is based on the long-period grating sensitivity to the surrounding medium refractive index, which leads to measurable modifications in the grating transmission spectrum. The proposed analysis method results in errors in the oil concentration of 0.4% and 2.6% for pure biodiesel and commercial soybean oil, respectively. Techniques of total glycerol, dynamic viscosity, density, and hydrogen nuclear magnetic resonance spectroscopy were also employed to validate the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to study the influence of green tea consumption on fluoride ingestion. The extraction conditions of fluorides from green tea infusions were defined and nine brands of green tea available in Portugal were analyzed. The quantification of fluorides in the green tea was preceded by the implementation and validation of the potentiometric method (commercial fluoride selective electrode). The concentration of fluorides in the samples ranged from 0. 8 to 2. 0 mg L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mobile networks of earlier and current generations, or 2G and 3G networks, provide users voice and packet services with higher transmission rates and good quality over the same core network. When developing the next generation of mobile networks the current quality of services needs to be maintained. This thesis concentrates on the next generation mobile network, especially on the evolution of the packet network part. The new mobile network has requirements for the common packet backbone network, Mobile Packet Backbone Network, which is additionally discussed in this study. The next generation mobile network, called LTE/SAE, is currently under testing. The test system is called Container Trial System. It is a mini sized LTE/SAE site. The LTE/SAE is studied in this thesis concentrating on the evolved packet core, the SAE part of the composition. The empirical part of the study compares the LTE/SAE Container Trial System and commercial network designs and additionally produces documentation for internal personnel and customers. The research is performed by comparing the documentations and specifications of both the Container Trial System and commercial network. Since the LTE commercial network is not yet constructed, the comparison is done theoretically. The purpose is furthermore to find out if there are any design issues that could be done differently in the next version of the Container Trial System.