952 resultados para CT scanning
Resumo:
This aim of this study was to evaluate the root apex of mandibular premolars regarding the presence of main and accessory foramina. The root apexes from fifty extracted mandibular single-rooted premolars were examined by scanning electron microscopy (SEM). The apical openings had their diameter measured and were identified as main or accessory foramina. Double blinded and calibrated examiners analyzed the SEM photographs and classified the premolar roots into three types, based on the presence and size of the apical openings. Type I: roots with a single main apical foramen and no accessory foramina; type II: roots with a main foramen and one or more accessory foramina; type III: roots with accessory foramina only. For the first premolar, 16 roots were classified as type I (48.48%), 4 as type II (12.12%) and 13 as type III (39.40%). For the second premolars, 10 roots were classified as type I (58.83%), 3 as type II (17.65%) and 4 as type III (23.52%). The high incidence of roots with accessory foramina only (type III), mainly in the first premolar, warns of the need for caution during working length determination and apical debridement.
Resumo:
A new device for irrigation, which presents hydrodynamic activation based on the pressure-suction technology, has recently been introduced to the market: the Rinsendo system. This study compared the efficacy of the Rinsendo system and conventional (manualdynamic) irrigation in the removal of debris from the root canal walls, using scanning electron microscopy (SEM). Twenty mandibular premolars with completely formed roots were selected and randomly divided into group 1 (irrigation with the Rinsendo system) and group 2 (conventional irrigation). The canals were irrigated with 1 ml of saline at each change of instrument. instrumentation started with a #15 K file and continued up to a #40 K file, which was standardized as the working length instrument. Then, the teeth were sectioned in buccolingual direction and the halves were sputter-coated with gold and examined by SEM. The apical, middle and cervical root canal thirds were evaluated, and the results were analyzed statistically by the Mann-Whitney test for comparison between methods, Kruskal-Wallis test for comparison among thirds, and Miller test for individual comparisons. A significance level of 5% was set for all analyses. The results did not show significant differences (p>0.05) between methods at each third and among thirds for each technique analyzed individually. in conclusion, there was no difference in the cleaning ability of the Rinsendo system and conventional irrigation.
Resumo:
This study evaluated the efficacy of 2 types of rotary instruments employed in association with sodium hypochlorite (NaOCl) or EDTA in removing calcium hydroxide (CH) residues from root canals dentin walls. Forty-two mandibular human incisors were instrumented with the ProTaper System up to F2 instrument, irrigated with 2.5% NaOCl followed by 17% EDTA and filled with a CH intracanal dressing. After 7 days, the CH dressing was removed using 4 techniques: NiTi rotary instrument size 25, 0.06 taper (K3 Endo) and irrigation with 17% EDTA (Group 1), NiTi rotary F1 instrument (ProTaper) and irrigation with 17% EDTA (Group 2), NiTi rotary instrument size 25, 0.06 taper and irrigation with 2.5% NaOCl (Group 3) and NiTi rotary F1 instrument and irrigation with 2.5% NaOCl (Group 4). Two roots without intracanal dressing were used as negative controls. Teeth were evaluated by scanning electron microscopy, in the cervical and apical canal thirds. None of the techniques removed the CH dressing completely. In the apical and cervical thirds, F1 instrument was better than instrument size 25, 0.06 taper in removing CH residues (p<0.05), regardless of the final irrigating solution. No difference was found between the irrigating solutions in the groups of F1 instrument and of instrument size 25, 0.06 taper (p>0.05). The negative controls had no CH residues on the dentin walls. In conclusion, the ProTaper F1 instrument was better than K3 Endo instrument size 25, 0.06 taper in the removal of CH intracanal medication, regardless of irrigating solution used.
Resumo:
The presence of precipitates in metallic materials affects its durability, resistance and mechanical properties. Hence, its automatic identification by image processing and machine learning techniques may lead to reliable and efficient assessments on the materials. In this paper, we introduce four widely used supervised pattern recognition techniques to accomplish metallic precipitates segmentation in scanning electron microscope images from dissimilar welding on a Hastelloy C-276 alloy: Support Vector Machines, Optimum-Path Forest, Self Organizing Maps and a Bayesian classifier. Experimental results demonstrated that all classifiers achieved similar recognition rates with good results validated by an expert in metallographic image analysis. © 2011 Springer-Verlag Berlin Heidelberg.
Resumo:
The purpose of this study was to evaluate commercially pure titanium implant surfaces modified by laser beam (LS) and LS associated with sodium silicate (SS) deposition, and compare them with machined surface (MS) and dual acid-etching surfaces (AS) modified. Topographic characterization was performed by scanning electron microscopy-X-ray energy dispersive spectroscopy (SEM-EDX), and by mean roughness measurement before surgery. Thirty rabbits received 60 implants in their right and left tibias. One implant of each surface in each tibia. The implants were removed by reverse torque for vivo biomechanical analysis at 30, 60, and 90 days postoperative. In addition, the surface of the implants removed at 30 days postoperative was analyzed by SEM-EDX. The topographic characterization showed differences between the analyzed surfaces, and the mean roughness values of LS and SS were statistically higher than AS and MS. At 30 days, values removal torque LS and SS groups showed a statistically significant difference (p < 0.05) when compared with MS and AS. At 60 days, groups LS and SS showed statistically significant difference (p < 0.05) when compared with MS. At 90 days, only group SS presented statistically higher (p < 0.05) in comparison with MS. The authors can conclude that physical chemistry properties and topographical of LS and SS implants increases bone-implant interaction and provides higher degree of osseointegration when compared with MS and AS. © 2012 Wiley Periodicals, Inc.
Resumo:
Objectives: The aim of this study was to compare cone beam CT (CBCT) in a small field of view (FOV) with a solid-state sensor and a photostimulable phosphor plate system for detection of cavitated approximal surfaces. Methods: 257 non-filled approximal surfaces from human permanent premolars and molars were recorded by two intraoral digital receptors, a storage phosphor plate (Digora Optime, Soredex) and a solid-state CMOS sensor (Digora Toto, Soredex), and scanned in a cone beam CT unit (3D Accuitomo FPD80, Morita) with a FOV of 4 cm and a voxel size of 0.08 mm. Image sections were carried out in the axial and mesiodistal tooth planes. Six observers recorded surface cavitation in all images. Validation of the true absence or presence of surface cavitation was performed by inspecting the surfaces under strong light with the naked eye. Differences in sensitivity, specificity and agreement were estimated by analysing the binary data in a generalized linear model using an identity link function. Results: A significantly higher sensitivity was obtained by all observers with CBCT (p,0.001), which was not compromised by a lower specificity. Therefore, a significantly higher overall agreement was obtained with CBCT (p,0.001). There were no significant differences between the Digora Optime phosphor plate system and the Digora Toto CMOS sensor for any parameter. Conclusions: CBCT was much more accurate in the detection of surface cavitation in approximal surfaces than intraoral receptors. The differences are interpreted as clinically significant. A CBCT examination performed for other reasons should also be assessed for approximal surface cavities in teeth without restorations. © 2013 The British Institute of Radiology.
Resumo:
The aim of this study was to compare two endodontic preparation systems using micro-CT analysis. Twenty-four one-rooted mandibular premolars were selected and randomly assigned to two groups. The samples (n = 12) of Group 1 were prepared using the ProTaper Universal rotary system, while Group 2 (n = 12) was prepared using the EndoEZE AET system complemented by manual apical preparation with K-type hand files up to #30. A 2.5% sodium hypochlorite solution was used in both groups for irrigating. Both groups were scanned by highresolution microcomputed tomography before and after preparation (SkyScan 1172, SkyScan, Kontich, Belgium). The root canal volume and surface area was measured before and after preparation, and the differences were calculated and analyzed for statistically significant differences using ANOVA complemented by the Tukey test (p < 0.05). The results showed no statistically significant differences between the mean volumes of dentin removal by the two systems. However, the EndoEZE AET system presented a significantly greater mean surface area compared to the ProTaper system (p < 0.05). The EndoEZE AET system enabled preparation of a greater root canal surface area when compared to the ProTaper Universal system. There seemed to be no difference in dentin volume loss between the two systems used.
Resumo:
Objective: To assess the influence of anatomical location on computed tomography (CT) numbers in mid- and full field of view (FOV) cone beam computed tomography (CBCT) scans. Study Design: Polypropylene tubes with varying concentrations of dipotassium hydrogen phosphate (K2HPO4) solutions (50-1200 mg/mL) were imaged within the incisor, premolar, and molar dental sockets of a human skull phantom. CBCT scans were acquired using the NewTom 3G and NewTom 5G units. The CT numbers of the K2HPO 4 phantoms were measured, and the relationship between CT numbers and K2HPO4 concentration was examined. The measured CT numbers of the K2HPO4 phantoms were compared between anatomical sites. Results: At all six anatomical locations, there was a strong linear relationship between CT numbers and K2HPO4 concentration (R 2 > 0.93). However, the absolute CT numbers varied considerably with the anatomical location. Conclusion: The relationship between CT numbers and object density is not uniform through the dental arch on CBCT scans. © 2013 Elsevier Inc.
Resumo:
Correlative fractography is a new expression proposed here to describe a new method for the association between scanning electron microscopy (SEM) and light microscopy (LM) for the qualitative and quantitative analysis of fracture surfaces. This article presents a new method involving the fusion of one elevation map obtained by extended depth from focus reconstruction from LM with exactly the same area by SEM and associated techniques, as X-ray mapping. The true topographic information is perfectly associated to local fracture mechanisms with this new technique, presented here as an alternative to stereo-pair reconstruction for the investigation of fractured components. The great advantage of this technique resides in the possibility of combining any imaging methods associated with LM and SEM for the same observed field from fracture surface. © Microscopy Society of America 2013.
Resumo:
The description of the larva of Amblyomma romitii Tonelli-Rondelli is based on optical and scanning electron microscopy. Larvae were obtained under laboratory conditions from an engorged female collected on capybara from Rurópolis municipality, State of Pará, Northern Brazil. Several characters are presented including the chaetotaxy of idiosoma, palpi and Haller's organ. The larval porotaxy (topographical and numerical patterns of integumentary structures) was presented and compared to that of the other Amblyomma spp. larvae. The mitochondrial 16S rDNA partial sequence of A. romitii generated in the present study was aligned with sequences previously determined for other Amblyomma species available in Genbank and with some species presently sequenced. The larval morphology of A. romitii and other Neotropical Amblyomma spp. larvae is discussed as well as the DNA sequence and its phylogenetic position among other species of the genus. © 2012 Springer Science+Business Media Dordrecht.
Resumo:
Objective To describe the technique of deep anterior lamellar keratoplasty (DALK) with Descemet's membrane (DM) exposure in horse eyes. Also, to compare the efficacy and safety of viscodissection and big-bubble techniques for DALK. Animals studied Thirty-four ex vivo horse eyes. Procedure Deep anterior lamellar keratoplasty was performed in 34 ex vivo horse eyes. Two groups (Group V - viscodissection - 2% sodium hyaluronate; Group A - air - big-bubble) of 17 eyes were studied. Other than the substance used, the surgical technique was similar for both groups. Nonperforated eyes were submitted for light microscopic histologic evaluation and scanning electron microscopic (SEM) analysis. Results Group V - Perforations occurred in 18% of the eyes during surgery. Light microscopy revealed exposure of DM in 28% of the eyes with mean thickness of the remaining stroma being 70.4μm. Group A - Perforations occurred in 42% of the eyes. Light microscopy revealed exposure of DM in 60% of the eyes with mean thickness of the remaining stroma being 23.3μm. No significant differences in safety, efficacy and thickness of the remaining stroma (including all eyes or excluding those with DM exposure) were observed. SEM of the surgical site revealed a more even surface in those eyes with DM exposure compared to eyes with thicker remaining stroma in both groups. Conclusions We describe two DALK techniques (viscodissection and big-bubble) for use in horses. No significant differences in safety, efficacy and thickness of the remaining stroma were observed. However, a nonsignificant trend toward the big-bubble technique being more efficacious but less safe was observed. © 2012 American College of Veterinary Ophthalmologists.
Resumo:
An indirect method for the georeferencing of 3D point clouds obtained with terrestrial laser scanning (TLS) data using control lines is presented. This technique could be used for rapid data acquisition where resources do not permit the use of expensive navigation sensors or the placement of pre-signalised targets. The most important characteristic is the development of a mathematical model based on the principle that the direction vector of the TLS straight line is coplanar with the plane defined by the origin of the TLS system, one endpoint of a control line and the direction vector of the control line in the ground reference coordinate system. The transformation parameters are estimated by minimising the distance between the control lines and their corresponding TLS straight lines. The proposed method was tested using both simulated and real data, and the advantages of this new approach are compared with conventional surveying methods. © 2013 This article is a U.S. Government work and is in the public domain in the USA.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
El Instituto Nicaraguense de Energia presenta al BID una solicitud de cooperacion tecnica consistente en el adiestramiento de un grupo de profesionales en tecnicas de analisis de sistemas electricos debiles o longitudinales de paises en desarrollo.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)