972 resultados para CT, Radiation Dose, Image Quality


Relevância:

40.00% 40.00%

Publicador:

Resumo:

RATIONALE:We investigated the impact of canakinumab, a fully human anti-interleukin-1b monoclonal antibody on inflammation and HRQoL in gouty arthritis patients.METHODS: In this 8-week, single-blind, dose-ranging study, patients with acute gouty arthritis flares, unresponsive/intolerant or contraindicated to NSAIDs and/or colchicine were randomized to single subcutaneous canakinumab (10, 25, 50, 90, or 150mg, N5143) or single intramuscular triamcinolone acetonide (TA, 40mg, N557). Patients assessed pain (Likert scale), physicians assessed clinical signs of joint inflammation, and HRQoL was recorded using SF-36.RESULTS: At baseline, 98% patients had moderate-to-extreme pain, 85% had moderate/severe joint swelling, 64-79% had elevated inflammatory markers and HRQoL scores indicated impaired physical function. Percentage of patients with no/mild pain was numerically greater in most canakinumab groups vs. TA, 24-72h post-dose; difference significant for 150mg group at these time-points (P<0.05). Canakinumab 150mg was associated with significantly lower Likert scores for tenderness [OR, 3.2; 95% CI, 1.27-7.89; P50.014] and swelling (OR, 2.7; 95% CI, 1.09-6.50, P50.032) at 72h vs. TA; erythema was not different. Median CRP and SAA levels normalized by 7 days post-dose in most canakinumab groups, but remained elevated in TA. Physical function improved at 7 days postdose in all groups, highest improvement for canakinumab 150mg. SF-36 scores for physical functioning and bodily pain with canakinumab 150mg approached US general population scores by 7 days post-dose and exceeded normal values by 8 weeks post-dose.CONCLUSION: Canakinumab 150mg produced significantly greater and rapid pain-relief and improvements in HRQoL vs. TAin acute gouty arthritis patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of radiotherapy is to deliver enough radiation to the tumor in order to achieve maximum tumour control in the irradiated volume with as few serious complications as possible with an irradiation dose as low as possible to normal tissue. The quality of radiotherapy is essential for optimal treatment and quality control is to reduce the bias in clinical trials avoiding possible major deviations. The assurance and quality control programs have been developed in large european (EORTC, GORTEC) and american cooperative groups (RTOG) of radiation oncology since the 1980s. We insist here on the importance of quality assurance in radiotherapy and the current status in this domain and the criteria for quality control especially for current clinical trials within GORTEC are discussed here.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Rapid response to : Madan M Rehani and Manorma Berry Radiation doses in computed tomography BMJ 2000; 320: 593-594

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Diplomityössä on käsitelty paperin pinnankarkeuden mittausta, joka on keskeisimpiä ongelmia paperimateriaalien tutkimuksessa. Paperiteollisuudessa käytettävät mittausmenetelmät sisältävät monia haittapuolia kuten esimerkiksi epätarkkuus ja yhteensopimattomuus sileiden papereiden mittauksissa, sekä suuret vaatimukset laboratorio-olosuhteille ja menetelmien hitaus. Työssä on tutkittu optiseen sirontaan perustuvia menetelmiä pinnankarkeuden määrittämisessä. Konenäköä ja kuvan-käsittelytekniikoita tutkittiin karkeilla paperipinnoilla. Tutkimuksessa käytetyt algoritmit on tehty Matlab® ohjelmalle. Saadut tulokset osoittavat mahdollisuuden pinnankarkeuden mittaamiseen kuvauksen avulla. Parhaimman tuloksen perinteisen ja kuvausmenetelmän välillä antoi fraktaaliulottuvuuteen perustuva menetelmä.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

ABSTRACT The objective of this study was to evaluate the effect of heat treatment and ultraviolet radiation (UV-C) in the prevention of chilling injury in mangoes cv. Tommy Atkins previously stored or not under injury condition after their transference to ambient condition. Fruits were divided into groups: two were hydrothermally treated (46.1 ºC/90 min; 55 ºC/5 min) and two were exposed to UV-C radiation (1.14 kJ m-2; 2.28 kJ m-2). These groups were stored under chilling injury conditions (5 ºC for 14 days), as established in preliminary tests. Other untreated groups were stored at 12 ºC or 5 ºC. After the storage period, they were transferred to ambient conditions (21.9 ºC; 55% RH) and the quality was evaluated. All the data were submitted to multivariate analysis as the tool to verify the simultaneous effect of the treatments under the quality parameters. The multivariate analysis indicated that the hydrothermal treatments at 46.1 °C/90 min and 55 °C/5 min and the UV-C radiation at doses of 1.14 kJ m-2 and 2.28 kJ m-2 were effective in minimized the symptoms of chilling injury in mangoes ‘Tommy Atkins’ stored at 5 °C for 14 days. However, after their transference to environmental condition at 21.9 °C, only the UV-C kept this control, especially at a dose of 2.28 kJ m-2. This treatment did not prevent the development of the characteristic color or affected the normal ripening and allowed the conservation of fruit for a period of 14 days at 5 °C, plus seven days of storage at environmental condition, which corresponds to the shipping transportation plus the time for sale.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We compared the health-related quality-of-life of patients with newly diagnosed multiple myeloma aged over 65 years or transplant-ineligible in the pivotal, phase III FIRST trial. Patients received: i) continuous lenalidomide and low-dose dexamethasone until disease progression; ii) fixed cycles of lenalidomide and low-dose dexamethasone for 18 months; or iii) fixed cycles of melphalan, prednisone, thalidomide for 18 months. Data were collected using the validated questionnaires (QLQ-MY20, QLQ-C30, and EQ-5D). The analysis focused on the EQ-5D utility value and six domains pre-selected for their perceived clinical relevance. Lenalidomide and low-dose dexamethasone, and melphalan, prednisone, thalidomide improved patients' health-related quality-of-life from baseline over the duration of the study across all pre-selected domains of the QLQ-C30 and EQ-5D. In the QLQ-MY20, lenalidomide and low-dose dexamethasone demonstrated a significantly greater reduction in the Disease Symptoms domain compared with melphalan, prednisone, thalidomide at Month 3, and significantly lower scores for QLQ-MY20 Side Effects of Treatment at all post-baseline assessments except Month 18. Linear mixed-model repeated-measures analyses confirmed the results observed in the cross-sectional analysis. Continuous lenalidomide and low-dose dexamethasone delays disease progression versus melphalan, prednisone, thalidomide and has been associated with a clinically meaningful improvement in health-related quality-of-life. These results further establish continuous lenalidomide and low-dose dexamethasone as a new standard of care for initial therapy of myeloma by demonstrating superior health-related quality-of-life during treatment, compared with melphalan, prednisone, thalidomide.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: The present study was aimed at evaluating the viability of replacing 18F with 99mTc in dose calibrator linearity testing. Materials and Methods: The test was performed with sources of 99mTc (62 GBq) and 18F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical 99mTc and 18F sources activities were calculated and subsequently compared. Results: Mean deviations between experimental and theoretical 99mTc and 18F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the 99mTc source as measured with the equipment pre-calibrated to measure 99mTc and 18F was 3.42 (± 0.06), and for the 18F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: The results of the linearity test using 99mTc were compatible with those obtained with the 18F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in 18F acquisition suggest 99mTc as the element of choice to perform dose calibrator linearity tests in centers that use 18F, without any detriment to the procedure as well as to the quality of the nuclear medicine service.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

AbstractObjective:In the present study, the authors investigated the in vitrobehavior of radio-resistant breast adenocarcinoma (MDA-MB-231) cells line and radiosensitive peripheral blood mononuclear cells (PBMC), as a function of different radiation doses, dose rates and postirradiation time kinetics, with a view to the interest of clinical radiotherapy.Materials and Methods:The cells were irradiated with Co-60, at 2 and 10 Gy and two different exposure rates, 339.56 cGy.min–1 and the other corresponding to one fourth of the standard dose rates, present over a 10-year period of cobalt therapy. Post-irradiation sampling was performed at pre-established kinetics of 24, 48 and 72 hours. The optical density response in viability assay was evaluated and a morphological analysis was performed.Results:Radiosensitive PBMC showed decrease in viability at 2 Gy, and a more significant decrease at 10 Gy for both dose rates. MDAMB- 231 cells presented viability decrease only at higher dose and dose rate. The results showed MDA-MB-231 clone expansion at low dose rate after 48–72 hours post-radiation.Conclusion:Low dose rate shows a possible potential clinical impact involving decrease in management of radio-resistant and radiosensitive tumor cell lines in cobalt therapy for breast cancer.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Some beetle species can have devastating economic impacts on forest and nursery industries. A recent example is Anophophora glabripennis, a species of beetle known in the United States as the ''Asian Longhorrned beetle'', which has damaged many American forests, and is a threat which can unintentionally reach south American countries, including Brazil. This work presents a new method based on X-ray computerized tomography (CT) and image processing for beetle injury detection in forests. Its results show a set of images with correct identification of the location of beetles in living trees as well as damage evaluation with time.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Planar, large area, position sensitive silicon detectors are widely utilized in high energy physics research and in medical, computed tomography (CT). This thesis describes author's research work relating to development of such detector components. The key motivation and objective for the research work has been the development of novel, position sensitive detectors improving the performance of the instruments they are intended for. Silicon strip detectors are the key components of barrel-shaped tracking instruments which are typically the innermost structures of high energy physics experimental stations. Particle colliders such as the former LEP collider or present LHC produce particle collisions and the silicon strip detector based trackers locate the trajectories of particles emanating from such collisions. Medical CT has become a regular part of everyday medical care in all developed countries. CT scanning enables x-ray imaging of all parts of the human body with an outstanding structural resolution and contrast. Brain, chest and abdomen slice images with a resolution of 0.5 mm are possible and latest CT machines are able to image whole human heart between heart beats. The two application areas are presented shortly and the radiation detection properties of planar silicon detectors are discussed. Fabrication methods and preamplifier electronics of the planar detectors are presented. Designs of the developed, large area silicon detectors are presented and measurement results of the key operating parameters are discussed. Static and dynamic performance of the developed silicon strip detectors are shown to be very satisfactory for experimental physics applications. Results relating to the developed, novel CT detector chips are found to be very promising for further development and all key performance goals are met.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study was conducted to evaluate the physicochemical and microbiological characteristics of raspberries exposed to different radiation doses. The fruits were harvested in the city of Campestre, MG, packed in polyethylene bags, and transported to the Federal University of Lavras (UFLA), where they were separated into 4 lots. Irradiation was performed at the Center for Development of Nuclear Technology in Belo Horizonte, MG. The doses used were 0 (control), 0.5, 1.0, and 2.0 kGy. After irradiation, the fruits were transported back to UFLA and stored at 1 ºC and 95% relative humidity (RH) for 12 days. The physicochemical analyses for mass loss, total soluble solids, titratable acidity, pH, total soluble sugars, total soluble pectin, firmness, vitamin C content, total antioxidant activity, and total phenolic, and the microbiological assays (coliform at 35 and 45 ºC, psychrotrophic and filamentous fungi and yeasts) were performed after 0, 3, 6, 9, and 12 days of storage. Lower loss of mass and filamentous fungi and yeast count were observed in the irradiated fruits, and 2 kGy was determined as the most effective dose for microbial control, but this irradiation dose also resulted in increased loss of fruit firmness.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The cellular structure of healthy food products, with added dietary fiber and low in calories, is an important factor that contributes to the assessment of quality, which can be quantified by image analysis of visual texture. This study seeks to compare image analysis techniques (binarization using Otsu’s method and the default ImageJ algorithm, a variation of the iterative intermeans method) for quantification of differences in the crumb structure of breads made with different percentages of whole-wheat flour and fat replacer, and discuss the behavior of the parameters number of cells, mean cell area, cell density, and circularity using response surface methodology. Comparative analysis of the results achieved with the Otsu and default ImageJ algorithms showed a significant difference between the studied parameters. The Otsu method demonstrated the crumb structure of the analyzed breads more reliably than the default ImageJ algorithm, and is thus the most suitable in terms of structural representation of the crumb texture.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In Brazil, although the coffee plantations are predominantly grown under full sunlight, the use of agroforestry systems can lead to socioeconomic advantages, thus providing a favorable environment to the crop by promoting its sustainability as well as environmental preservation. However, there is a lack of information on physiological quality of the coffee seeds produced under different levels of solar radiation. Within this context, the objective of this study was to evaluate the influence of different levels of solar radiation and maturation stages on the physiological quality of coffee (Coffea arabica L.) seeds, cv. Acaiá Cerrado MG-1474. Three levels of solar radiation (plants grown under full sunlight; under plastic screens of 35% shading; and under plastic screens of 50% shading) and three maturation stages (cherry, greenish-yellow and green) were assessed. Physiological quality of seeds was assessed by using germination test, first count of germination, abnormal seedlings, dead seeds, and seedlings with open cotyledonary leaves. Electrophoretic analysis of isoenzymes catalase, esterase, superoxide dismutase and peroxidase was also performed. With the evolution of development the coffee seeds presents increases on physiological quality, and at its beginning the seeds show improvements on quality with the reduction of solar radiation.