937 resultados para CMOS sensors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, fibre optic sensors (FOS) were used to investigate the interfacial stress-strain behaviour of bonded-in basalt fibre reinforced polymer (BFRP) rods loaded into glulam members. Pull-out tests were conducted to examine the effect of bonded length and load-to-grain direction on the distribution of stress at the BFRP rod/adhesive zone. It was observed that the stress concentration at the loaded end of the BFRP rod of the samples was significantly the highest while the unloaded end showed the lowest. Increasing the bonded length at the same loading configuration resulted in a decrease in stress concentration at the loaded end. The stress concentration at the loaded end of the perpendicular to the grain samples was relatively higher than that of the corresponding parallel to the grain samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because of their extraordinary structural and electrical properties, two dimensional materials are currently being pursued for applications such as thin-film transistors and integrated circuit. One of the main challenges that still needs to be overcome for these applications is the fabrication of air-stable transistors with industry-compatible complementary metal oxide semiconductor (CMOS) technology. In this work, we experimentally demonstrate a novel high performance air-stable WSe2 CMOS technology with almost ideal voltage transfer characteristic, full logic swing and high noise margin with different supply voltages. More importantly, the inverter shows large voltage gain (~38) and small static power (Pico-Watts), paving the way for low power electronic system in 2D materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Development of Internet-of-Services will be hampered by heterogeneous Internet-of-Things infrastructures, such as inconsistency in communicating with participating objects, connectivity between them, topology definition & data transfer, access via cloud computing for data storage etc. Our proposed solutions are applicable to a random topology scenario that allow establishing of multi-operational sensor networks out of single networks and/or single service networks with the participation of multiple networks; thus allowing virtual links to be created and resources to be shared. The designed layers are context-aware, application-oriented, and capable of representing physical objects to a management system, along with discovery of services. The reliability issue is addressed by deploying IETF supported IEEE 802.15.4 network model for low-rate wireless personal networks. Flow- sensor succeeded better results in comparison to the typical - sensor from reachability, throughput, energy consumption and diversity gain viewpoint and through allowing the multicast groups into maximum number, performances can be improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-08

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé : Les photodiodes à avalanche monophotonique (SPAD) sont d'intérêts pour les applications requérant la détection de photons uniques avec une grande résolution temporelle, comme en physique des hautes énergies et en imagerie médicale. En fait, les matrices de SPAD, souvent appelés photomultiplicateurs sur silicium (SiPM), remplacent graduellement les tubes photomultiplicateurs (PMT) et les photodiodes à avalanche (APD). De plus, il y a une tendance à utiliser les matrices de SPAD en technologie CMOS afin d'obtenir des pixels intelligents optimisés pour la résolution temporelle. La fabrication de SPAD en technologie CMOS commerciale apporte plusieurs avantages par rapport aux procédés optoélectroniques comme le faible coût, la capacité de production, l'intégration d'électronique et la miniaturisation des systèmes. Cependant, le défaut principal du CMOS est le manque de flexibilité de conception au niveau de l'architecture du SPAD, causé par le caractère fixe et standardisé des étapes de fabrication en technologie CMOS. Un autre inconvénient des matrices de SPAD CMOS est la perte de surface photosensible amenée par la présence de circuits CMOS. Ce document présente la conception, la caractérisation et l'optimisation de SPAD fabriqués dans une technologie CMOS commerciale (Teledyne DALSA 0.8µm HV CMOS - TDSI CMOSP8G). Des modifications de procédé sur mesure ont été introduites en collaboration avec l'entreprise CMOS pour optimiser les SPAD tout en gardant la compatibilité CMOS. Les matrices de SPAD produites sont dédiées à être intégrées en 3D avec de l'électronique CMOS économique (TDSI) ou avec de l'électronique CMOS submicronique avancée, produisant ainsi un SiPM 3D numérique. Ce SiPM 3D innovateur vise à remplacer les PMT, les APD et les SiPM commerciaux dans les applications à haute résolution temporelle. L'objectif principal du groupe de recherche est de développer un SiPM 3D avec une résolution temporelle de 10 ps pour usage en physique des hautes énergies et en imagerie médicale. Ces applications demandent des procédés fiables avec une capacité de production certifiée, ce qui justifie la volonté de produire le SiPM 3D avec des technologies CMOS commerciales. Ce mémoire étudie la conception, la caractérisation et l'optimisation de SPAD fabriqués en technologie TDSI-CMOSP8G.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pavements tend to deteriorate with time under repeated traffic and/or environmental loading. By detecting pavement distresses and damage early enough, it is possible for transportation agencies to develop more effective pavement maintenance and rehabilitation programs and thereby achieve significant cost and time savings. The structural health monitoring (SHM) concept can be considered as a systematic method for assessing the structural state of pavement infrastructure systems and documenting their condition. Over the past several years, this process has traditionally been accomplished through the use of wired sensors embedded in bridge and highway pavement. However, the use of wired sensors has limitations for long-term SHM and presents other associated cost and safety concerns. Recently, micro-electromechanical sensors and systems (MEMS) and nano-electromechanical systems (NEMS) have emerged as advanced/smart-sensing technologies with potential for cost-effective and long-term SHM. This two-pronged study evaluated the performance of commercial off-the-shelf (COTS) MEMS sensors embedded in concrete pavement (Final Report Volume I) and developed a wireless MEMS multifunctional sensor system for health monitoring of concrete pavement (Final Report Volume II).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé : Le transistor monoélectronique (SET) est un dispositif nanoélectronique très attractif à cause de son ultra-basse consommation d’énergie et sa forte densité d’intégration, mais il n’a pas les capacités suffisantes pour pouvoir remplacer complètement la technologie CMOS. Cependant, la combinaison de la technologie SET avec celle du CMOS est une voie intéressante puisqu’elle permet de profiter des forces de chacune, afin d’obtenir des circuits avec des fonctionnalités additionnelles et uniques. Cette thèse porte sur l’intégration 3D monolithique de nanodispositifs dans le back-end-of-line (BEOL) d’une puce CMOS. Cette approche permet d’obtenir des circuits hybrides et de donner une valeur ajoutée aux puces CMOS actuelles sans altérer le procédé de fabrication du niveau des transistors MOS. L’étude se base sur le procédé nanodamascène classique développé à l’UdeS qui a permis la fabrication de dispositifs nanoélectroniques sur un substrat de SiO2. Ce document présente les travaux réalisés sur l’optimisation du procédé de fabrication nanodamascène, afin de le rendre compatible avec le BEOL de circuits CMOS. Des procédés de gravure plasma adaptés à la fabrication de nanostructures métalliques et diélectriques sont ainsi développés. Le nouveau procédé nanodamascène inverse a permis de fabriquer des jonctions MIM et des SET métalliques sur une couche de SiO2. Les caractérisations électriques de MIM et de SET formés avec des jonctions TiN/Al2O3 ont permis de démontrer la présence de pièges dans les jonctions et la fonctionnalité d’un SET à basse température (1,5 K). Le transfert de ce procédé sur CMOS et le procédé d’interconnexions verticales sont aussi développés par la suite. Finalement, un circuit 3D composé d’un nanofil de titane connecté verticalement à un transistor MOS est réalisé et caractérisé avec succès. Les résultats obtenus lors de cette thèse permettent de valider la possibilité de co-intégrer verticalement des dispositifs nanoélectroniques avec une technologie CMOS, en utilisant un procédé de fabrication compatible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fiber optical sensors have played an important role in applications for monitoring the health of civil infrastructures, such as bridges, oil rigs, and railroads. Due to the reduction in cost of fiber-optic components and systems, fiber optical sensors have been studied extensively for their higher sensitivity, precision and immunity to electrical interference compared to their electrical counterparts. A fiber Bragg grating (FBG) strain sensor has been employed for this study to detect and distinguish normal and lateral loads on rail tracks. A theoretical analysis of the relationship between strain and displacement under vertical and horizontal strains on an aluminum beam has been performed, and the results are in excellent agreement with the measured strain data. Then a single FBG sensor system with erbium-doped fiber amplifier broadband source has been carried out. Force and temperature applied on the system have resulted in changes of 0.05 nm per 50 με and 0.094 nm per 10 oC at the center wavelength of the FBG. Furthermore, a low cost fiber-optic sensor system with a distributed feedback (DFB) laser as the light source has been implemented. We show that it has superior noise and sensitivity performances compared to strain gauge sensors. The design has been extended to accommodate multiple sensors with negligible cross talk. When two cascaded sensors on a rail track section are tested, strain readings of the sensor 20 inches away from the position of applied force decay to one seventh of the data of the sensor at the applied force location. The two FBG sensor systems can detect 1 ton of vertical load with a square wave pattern and 0.1 ton of lateral loads (3 tons and 0.5 ton, respectively, for strain gauges). Moreover, a single FBG sensor has been found capable of detecting and distinguishing lateral and normal strains applied at different frequencies. FBG sensors are promising alternatives to electrical sensors for their high sensitivity,ease of installation, and immunity to electromagnetic interferences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biochemical agents, including bacteria and toxins, are potentially dangerous and responsible for a wide variety of diseases. Reliable detection and characterization of small samples is necessary in order to reduce and eliminate their harmful consequences. Microcantilever sensors offer a potential alternative to the state of the art due to their small size, fast response time, and the ability to operate in air and liquid environments. At present, there are several technology limitations that inhibit application of microcantilever to biochemical detection and analysis, including difficulties in conducting temperature-sensitive experiments, material inadequacy resulting in insufficient cell capture, and poor selectivity of multiple analytes. This work aims to address several of these issues by introducing microcantilevers having integrated thermal functionality and by introducing nanocrystalline diamond as new material for microcantilevers. Microcantilevers are designed, fabricated, characterized, and used for capture and detection of cells and bacteria. The first microcantilever type described in this work is a silicon cantilever having highly uniform in-plane temperature distribution. The goal is to have 100 μm square uniformly heated area that can be used for thermal characterization of films as well as to conduct chemical reactions with small amounts of material. Fabricated cantilevers can reach above 300C while maintaining temperature uniformity of 2−4%. This is an improvement of over one order of magnitude over currently available cantilevers. The second microcantilever type is a doped single crystal silicon cantilever having a thin coating of ultrananocrystalline diamond (UNCD). The primary application of such a device is in biological testing, where diamond acts as a stable, electrically isolated reaction surface while silicon layer provides controlled heating with minimum variations in temperature. This work shows that composite cantilevers of this kind are an effective platform for temperature-sensitive biological experiments, such as heat lysing and polymerase chain reaction. The rapid heat-transfer of Si-UNCD cantilever compromised the membrane of NIH 3T3 fibroblast and lysed the cell nucleus within 30 seconds. Bacteria cells, Listeria monocytogenes V7, were shown to be captured with biotinylated heat-shock protein on UNCD surface and 90% of all viable cells exhibit membrane porosity due to high heat in 15 seconds. Lastly, a sensor made solely from UNCD diamond is fabricated with the intention of being used to detect the presence of biological species by means of an integrated piezoresistor or through frequency change monitoring. Since UNCD diamond has not been previously used in piezoresistive applications, temperature-denpendent piezoresistive coefficients and gage factors are determined first. The doped UNCD exhibits a significant piezoresistive effect with gauge factor of 7.53±0.32 and a piezoresistive coefficient of 8.12×10^−12 Pa^−1 at room temperature. The piezoresistive properties of UNCD are constant over the temperature range of 25−200C. 300 μm long cantilevers have the highest sensitivity of 0.186 m-Ohm/Ohm per μm of cantilever end deflection, which is approximately half that of similarly sized silicon cantilevers. UNCD cantilever arrays were fabricated consisting of four sixteen-cantilever arrays of length 20–90 μm in addition to an eight-cantilever array of length 120 μm. Laser doppler vibrometry (LDV) measured the cantilever resonant frequency, which ranged as 218 kHz−5.14 MHz in air and 73 kHz−3.68 MHz in water. The quality factor of the cantilever was 47−151 in air and 18−45 in water. The ability to measure frequencies of the cantilever arrays opens the possibility for detection of individual bacteria by monitoring frequency shift after cell capture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stress is a phenomenon that on some level affects everyone’s lives on a daily basis. The autonomic nervous system controls the varying levels of stress at any given time. The responses of the autonomic nervous system adjust the body to cope with changing external and internal conditions. During high-stress situations the body is forced into a state of heightened alertness, which passes when the stressor is removed. The stressor can be any external or internal event that causes the body to respond. Stress is a very versatile phenomenon that can be both a cause and an indicator of other medical conditions, for example cardiovascular disease. Stress detection can therefore be helpful in identifying these conditions and monitoring the overall emotional state of a person. Electrodermal activity (EDA) is one of the most easily implemented ways to monitor the activity of the autonomic nervous system. EDA describes changes occurring in the various electrical properties of the skin, including skin conductivity and resistance. Increased emotional sweating has been proven to be one possible indication of stress. On the surface of the skin, increased sweating translates to increased skin conductivity, which can be observed through EDA measurements. This makes electrodermal activity a very useful tool in a wide range of applications where it is desirable to observe changes in a person’s stress level. EDA can be recorded by using specialized body sensors placed on specific locations on the body. Most commonly used recording sites are the palms of the hands due to the high sweat gland density on those areas. Measurement is done using at least two electrodes attached to the skin, and recording the electrical conductance between them. This thesis implements a prototype of a wireless EDA measurement system. The feasibility of the prototype is also verified with a small group of test subjects. EDA was recorded from the subjects while they were playing a game of Tetris. The goal was to observe variations in the measured EDA that would indicate changes in the subjects’ stress levels during the game. The analysis of the obtained measurement results confirmed the connection between stress and recorded EDA. During the game, random occurrences of lowered skin resistance were clearly observable, which indicates points in the game where the player felt more anxious. A wireless measurement system has the potential of offering more flexible and comfortable long-term measuring of EDA, and could be utilized in a wide range of applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal Diagnostics experiments to be carried out on board LISA Pathfinder (LPF) will yield a detailed characterisation of how temperature fluctuations affect the LTP (LISA Technology Package) instrument performance, a crucial information for future space based gravitational wave detectors as the proposed eLISA. Amongst them, the study of temperature gradient fluctuations around the test masses of the Inertial Sensors will provide as well information regarding the contribution of the Brownian noise, which is expected to limit the LTP sensitivity at frequencies close to 1mHz during some LTP experiments. In this paper we report on how these kind of Thermal Diagnostics experiments were simulated in the last LPF Simulation Campaign (November, 2013) involving all the LPF Data Analysis team and using an end-to-end simulator of the whole spacecraft. Such simulation campaign was conducted under the framework of the preparation for LPF operations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simultaneous Localization and Mapping (SLAM) is a procedure used to determine the location of a mobile vehicle in an unknown environment, while constructing a map of the unknown environment at the same time. Mobile platforms, which make use of SLAM algorithms, have industrial applications in autonomous maintenance, such as the inspection of flaws and defects in oil pipelines and storage tanks. A typical SLAM consists of four main components, namely, experimental setup (data gathering), vehicle pose estimation, feature extraction, and filtering. Feature extraction is the process of realizing significant features from the unknown environment such as corners, edges, walls, and interior features. In this work, an original feature extraction algorithm specific to distance measurements obtained through SONAR sensor data is presented. This algorithm has been constructed by combining the SONAR Salient Feature Extraction Algorithm and the Triangulation Hough Based Fusion with point-in-polygon detection. The reconstructed maps obtained through simulations and experimental data with the fusion algorithm are compared to the maps obtained with existing feature extraction algorithms. Based on the results obtained, it is suggested that the proposed algorithm can be employed as an option for data obtained from SONAR sensors in environment, where other forms of sensing are not viable. The algorithm fusion for feature extraction requires the vehicle pose estimation as an input, which is obtained from a vehicle pose estimation model. For the vehicle pose estimation, the author uses sensor integration to estimate the pose of the mobile vehicle. Different combinations of these sensors are studied (e.g., encoder, gyroscope, or encoder and gyroscope). The different sensor fusion techniques for the pose estimation are experimentally studied and compared. The vehicle pose estimation model, which produces the least amount of error, is used to generate inputs for the feature extraction algorithm fusion. In the experimental studies, two different environmental configurations are used, one without interior features and another one with two interior features. Numerical and experimental findings are discussed. Finally, the SLAM algorithm is implemented along with the algorithms for feature extraction and vehicle pose estimation. Three different cases are experimentally studied, with the floor of the environment intentionally altered to induce slipping. Results obtained for implementations with and without SLAM are compared and discussed. The present work represents a step towards the realization of autonomous inspection platforms for performing concurrent localization and mapping in harsh environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work three different metallic metamaterials (MMs) structures such as asymmetric split ring resonators (A-SRRs), dipole and split H-shaped (ASHs) structures that support plasmonic resonances have been developed. The aim of the work involves the optimization of photonic sensor based on plasmonic resonances and surface enhanced infrared absorption (SEIRA) from the MM structures. The MMs structures were designed to tune their plasmonic resonance peaks in the mid-infrared region. The plasmonic resonance peaks produced are highly dependent on the structural dimension and polarisation of the electromagnetic (EM) source. The ASH structure particularly has the ability to produce the plasmonic resonance peak with dual polarisation of the EM source. The double resonance peaks produced due to the asymmetric nature of the structures were optimized by varying the fundamental parameters of the design. These peaks occur due to hybridization of the individual elements of the MMs structure. The presence of a dip known as a trapped mode in between the double plasmonic peaks helps to narrow the resonances. A periodicity greater than twice the length and diameter of the metallic structure was applied to produce narrow resonances for the designed MMs. A nanoscale gap in each structure that broadens the trapped mode to narrow the plasmonic resonances was also used. A thickness of 100 nm gold was used to experimentally produce a high quality factor of 18 in the mid-infrared region. The optimised plasmonic resonance peaks was used for detection of an analyte, 17β-estradiol. 17β-estradiol is mostly responsible for the development of human sex organs and can be found naturally in the environment through human excreta. SEIRA was the method applied to the analysis of the analyte. The work is important in the monitoring of human biology and in water treatment. Applying this method to the developed nano-engineered structures, enhancement factors of 10^5 and a sensitivity of 2791 nm/RIU was obtained. With this high sensitivity a figure of merit (FOM) of 9 was also achieved from the sensors. The experiments were verified using numerical simulations where the vibrational resonances of the C-H stretch from 17β-estradiol were modelled. Lastly, A-SRRs and ASH on waveguides were also designed and evaluated. These patterns are to be use as basis for future work.