986 resultados para CARDIAC-PERFORMANCE
Resumo:
This work describes a novel use for the polymeric film, poly(o-aminophenol) (PAP) that was made responsive to a specific protein. This was achieved through templated electropolymerization of aminophenol (AP) in the presence of protein. The procedure involved adsorbing protein on the electrode surface and thereafter electroploymerizing the aminophenol. Proteins embedded at the outer surface of the polymeric film were digested by proteinase K and then washed away thereby creating vacant sites. The capacity of the template film to specifically rebind protein was tested with myoglobin (Myo), a cardiac biomarker for ischemia. The films acted as biomimetic artificial antibodies and were produced on a gold (Au) screen printed electrode (SPE), as a step towards disposable sensors to enable point-of-care applications. Raman spectroscopy was used to follow the surface modification of the Au-SPE. The ability of the material to rebind Myo was measured by electrochemical techniques, namely electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The devices displayed linear responses to Myo in EIS and SWV assays down to 4.0 and 3.5 μg/mL, respectively, with detection limits of 1.5 and 0.8 μg/mL. Good selectivity was observed in the presence of troponin T (TnT) and creatine kinase (CKMB) in SWV assays, and accurate results were obtained in applications to spiked serum. The sensor described in this work is a potential tool for screening Myo in point-of-care due to the simplicity of fabrication, disposability, short time response, low cost, good sensitivity and selectivity.
Resumo:
IEEE International Conference on Communications (IEEE ICC 2015). 8 to 12, Jun, 2015, IEEE ICC 2015 - Communications QoS, Reliability and Modeling, London, United Kingdom.
Resumo:
A 66-year-old female with Streptococcus viridans aortic and tricuspid infective endocarditis develops, during the course of antibiotic therapy, rupture of a right coronary sinus of Valsalva aneurysm to the right ventricle. An urgent cardiac surgery is preformed with implantation of a mechanical aortic prosthesis and a right coronary sinus plasty. Six months later a huge aortic pseudoaneurysm is diagnosed and she is submitted to a second uneventful surgery. A review is done for the significant features with discussion of diagnosis and therapy.
Resumo:
The shifted Legendre orthogonal polynomials are used for the numerical solution of a new formulation for the multi-dimensional fractional optimal control problem (M-DFOCP) with a quadratic performance index. The fractional derivatives are described in the Caputo sense. The Lagrange multiplier method for the constrained extremum and the operational matrix of fractional integrals are used together with the help of the properties of the shifted Legendre orthonormal polynomials. The method reduces the M-DFOCP to a simpler problem that consists of solving a system of algebraic equations. For confirming the efficiency and accuracy of the proposed scheme, some test problems are implemented with their approximate solutions.
Resumo:
Cardiac hydatid cyst is a rare disease, especially in children. An 11-year-old boy with a previous anaphylactic reaction and episodes of abdominal pain was admitted for workup of an acquired long systolic murmur. Echocardiographic investigation disclosed a tumor of the right ventricular anterior wall, with multiple loculations. Magnetic resonance imaging characterized it as a multilobular tumor with cyst formation and disclosed another cyst in the right pulmonary artery. With a positive ELISA reaction the child was admitted for surgery with the diagnosis of cardiac and pulmonary hydatid cysts. Cardiac surgery was performed with good results, followed by medical treatment with albendazole.
Resumo:
Although the Giemsa-stained thick blood smear (GTS) remains the gold standard for the diagnosis of malaria, molecular methods are more sensitive and specific to detect parasites and can be used at reference centers to evaluate the performance of microscopy. The description of the Plasmodium falciparum, P. vivax, P. malariae and P. ovale ssrRNA gene sequences allowed the development of a polymerase chain reaction (PCR) that had been used to differentiate the four species. The objective of this study was to determine Plasmodium species through PCR in 190 positive smears from patients in order to verify the quality of diagnosis at SUCEN's Malaria Laboratory. Considering only the 131 positive results in both techniques, GTS detected 4.6% of mixed and 3.1% of P. malariae infections whereas PCR identified 19.1% and 13.8%, respectively.
Resumo:
We report a case of phaeohyphomycosis caused by Exophiala jeanselmei in a cardiac transplant recipient maintained on immunosuppressive therapy with mycophenolate mofetil tacrolimus and prednisone. The lesion began after trauma on the right leg that evolved to multiple lesions with nodules and ulcers. Diagnosis was performed by histological examination and culture of pus from skin lesions. Treatment consisted of itraconazole (200 mg/day) for three months with no improvement and subsequently with amphotericin B (0.5 mg/Kg per day to a total of 3.8 g intravenously). After four months of treatment, the lesions showed marked improvement with reduction in the swelling and healing of sinuses and residual scaring.
Resumo:
RTUWO Advances in Wireless and Optical Communications 2015 (RTUWO 2015). 5-6 Nov Riga, Latvia.
Resumo:
INTRODUCTION: Adults with repaired tetralogy of Fallot (TOF) may be at risk for progressive right ventricular (RV) dilatation and dysfunction, which is commonly associated with arrhythmic events. In frequently volume-overloaded patients with congenital heart disease, tissue Doppler imaging (TDI) is particularly useful for assessing RV function. However, it is not known whether RV TDI can predict outcome in this population. OBJECTIVE: To evaluate whether RV TDI parameters are associated with supraventricular arrhythmic events in adults with repaired TOF. METHODS: We studied 40 consecutive patients with repaired TOF (mean age 35 +/- 11 years, 62% male) referred for routine echocardiographic exam between 2007 and 2008. The following echocardiographic measurements were obtained: left ventricular (LV) ejection fraction, LV end-systolic volume, LV end-diastolic volume, RV fractional area change, RV end-systolic area, RV end-diastolic area, left and right atrial volumes, mitral E and A velocities, RV myocardial performance index (Tei index), tricuspid annular plane systolic excursion (TAPSE), myocardial isovolumic acceleration (IVA), pulmonary regurgitation color flow area, TDI basal lateral, septal and RV lateral peak diastolic and systolic annular velocities (E' 1, A' 1, S' 1, E' s, A' s, S' s, E' rv, A' rv, S' rv), strain, strain rate and tissue tracking of the same segments. QRS duration on resting ECG, total duration of Bruce treadmill exercise stress test and presence of exercise-induced arrhythmias were also analyzed. The patients were subsequently divided into two groups: Group 1--12 patients with previous documented supraventricular arrhythmias (atrial tachycardia, fibrillation or flutter) and Group 2 (control group)--28 patients with no previous arrhythmic events. Univariate and multivariate analysis was used to assess the statistical association between the studied parameters and arrhythmic events. RESULTS: Patients with previous events were older (41 +/- 14 vs. 31 +/- 6 years, p = 0.005), had wider QRS (173 +/- 20 vs. 140 +/- 32 ms, p = 0.01) and lower maximum heart rate on treadmill stress testing (69 +/- 35 vs. 92 +/- 9%, p = 0.03). All patients were in NYHA class I or II. Clinical characteristics including age at corrective surgery, previous palliative surgery and residual defects did not differ significantly between the two groups. Left and right cardiac chamber dimensions and ventricular and valvular function as evaluated by conventional Doppler parameters were also not significantly different. Right ventricular strain and strain rate were similar between the groups. However, right ventricular myocardial TDI systolic (Sa: 5.4+2 vs. 8.5 +/- 3, p = 0.004) and diastolic indices and velocities (Ea, Aa, septal E/Ea, and RV free wall tissue tracking) were significantly reduced in patients with arrhythmias compared to the control group. Multivariate linear regression analysis identified RV early diastolic velocity as the sole variable independently associated with arrhythmic history (RV Ea: 4.5 +/- 1 vs. 6.7 +/- 2 cm/s, p = 0.01). A cut-off for RV Ea of < 6.1 cm/s identified patients in the arrhythmic group with 86% sensitivity and 59% specificity (AUC = 0.8). CONCLUSIONS: Our results suggest that TDI may detect RV dysfunction in patients with apparently normal function as assessed by conventional echocardiographic parameters. Reduction in RV early diastolic velocity appears to be an early abnormality and is associated with occurrence of arrhythmic events. TDI may be useful in risk stratification of patients with repaired tetralogy of Fallot.
Resumo:
This study aims to analyze and compare four micro-firms' organizational culture, evaluated through the Competing Values Framework (Quinn & Rohbaugh, 1983). Data was collected in 2011 and 2013 in firms selling the same type of software and providing the same kind of services, focusing on the years between 2008-2011. Findings point to somewhat different results of micro-firms, when comparing to other samples in the literature. Suggestions for future research are given.
Resumo:
This study aims at investigating the influence that entrepreneurial orientation has on export performance of Portuguese footwear small and mediumenterprises (SMEs). Therefore, a quantitative methodological approach was used, conducting a descriptive, exploratory and transversal empirical study, having applied a questionnaire to a sample of Portuguese companies exporting footwear. The research results suggest that entrepreneurial orientation enhances export performance in the analysed SMEs, particularly innovation and proactiveness, through the amount of funds invested, human resources dedicated to this activity, number of new products or services introduced in the market and frequent change in product lines or services and materialization of a long-term perspective, which is accompanied by innovative activities or new businesses. Therefore, the findings sustain the necessity to invest in entrepreneurial orientation as a strategic determinant, which contributes to the growth of small firms in foreignmarkets. Finally, the main limitation of this study is related to the sample size, since it was difficult to find companies willing to collaborate with this kind of research.
Resumo:
Redundant manipulators have some advantages when compared with classical arms because they allow the trajectory optimization, both on the free space and on the presence of abstacles, and the resolution of singularities. For this type of manipulators, several kinetic algorithms adopt generalized inverse matrices. In this line of thought, the generalized inverse control scheme is tested through several experiments that reveal the difficulties that often arise. Motivated by theseproblems this paper presents a new method that ptimizes the manipulability through a least squre polynomialapproximation to determine the joints positions. Moreover, the article studies influence on the dynamics, when controlling redundant and hyper-redundant manipulators. The experiment confirm the superior performance of the proposed algorithm for redundant and hyper-redundant manipulators, revealing several fundamental properties of the chaotic phenomena, and gives a deeper insight towards the future development of superior trajectory control algorithms.
Resumo:
This paper presents the dynamic analysis of robotic biped systems. The main goal is to gain insight into the phenomena of walking and to evaluate its performance. In this study, we propose three methods to quantitatively measure the dynamic efficiency of walking: energy analysis, perturbation analysis and lowpass frequency analysis. In order to accomplish this goal, the prescribed motion of the biped is completely characterised in terms of a set of locomotion variables, namely: step lenght, hip height, hip ripple, hip offset, foot clearance and link lenghts. based on these variables and their influence, the performance measures aer discussed and the results compared with those observed in nature.
Resumo:
Assessment of surgical performance is a must for every surgical practice nowadays and can be done by using scientific methods imported mostly from the Quality control tools that have been in use for long in industry. Surgical performance comprises several dimensions including clinical activity (mortality and morbidity as end points), academic activities, research and, more and more, efficiency. Stable long time results (efficacy), reducing error (safety) and meeting patient expectations (patient satisfaction) are among other performance components. This paper focus on the precise definitions of mortality and morbidity related to surgical activities and on the tools to evaluate patient complexity and assess pre operative risk. Some graphic representations are suggested to compare performance profiles of surgeons and to define individual performance profiles. Strong emphasis is put on pre operative risk assessment and its crucial role to interpret divergent surgical results. Where risk assessment is not possible or is unavailable, observed / expected ratios (O/E) for a given endpoint , be it mortality, length of stay or morbidity, must be established and routinely used to refer results and to identify performance outliers. Morbidity is being pointed out as a most valuable performance indicator in surgery because it is sensitive and comprises efficiency, safety and quality, at large.