955 resultados para Bodily fluids.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports the first observations of transition from a pre-vortex breakdown (Pre-VB) flowreversal to a fully developed central toroidal recirculation zone in a non-reacting, double-concentric swirling jet configuration and its response to longitudinal acoustic excitation. This transition proceeds with the formation of two intermediate, critical flow regimes. First, a partially penetrated vortex breakdown bubble (VBB) is formed that indicates the first occurrence of an enclosed structure as the centre jet penetration is suppressed by the growing outer roll-up eddy; resulting in an opposed flow stagnation region. Second, a metastable transition structure is formed that marks the collapse of inner mixing vortices. In this study, the time-averaged topological changes in the coherent recirculation structures are discussed based on the non-dimensional modified Rossby number (Ro(m)) which appears to describe the spreading of the zone of swirl influence in different flow regimes. Further, the time-mean global acoustic response of pre-VB and VBB is measured as a function of pulsing frequency using the relative aerodynamic blockage factor (i.e., maximum radial width of the inner recirculation zone). It is observed that all flow modes except VBB are structurally unstable as they exhibit severe transverse radial shrinkage (similar to 20%) at the burner Helmholtz resonant modes (100-110 Hz). In contrast, all flow regimes show positional instability as seen by the large-scale, asymmetric spatial shifting of the vortex core centres. Finally, the mixing transfer function M (f) and magnitude squared coherence lambda(2)(f) analysis is presented to determine the natural couplingmodes of the system dynamic parameters (u', p'), i.e., local acoustic response. It is seen that the pre-VB flow mode exhibits a narrow-band, low pass filter behavior with a linear response window of 100-105 Hz. However, in the VBB structure, presence of critical regions such as the opposed flow stagnation region alters the linearity range with the structure showing a response even at higher pulsing frequencies (100-300 Hz). (C) 2013 AIP Publishing LLC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An analysis of the energy budget for the general case of a body translating in a stationary fluid under the action of an external force is used to define a power loss coefficient. This universal definition of power loss coefficient gives a measure of the energy lost in the wake of the translating body and, in general, is applicable to a variety of flow configurations including active drag reduction, self-propulsion and thrust generation. The utility of the power loss coefficient is demonstrated on a model bluff body flow problem concerning a two-dimensional elliptical cylinder in a uniform cross-flow. The upper and lower boundaries of the elliptic cylinder undergo continuous motion due to a prescribed reflectionally symmetric constant tangential surface velocity. It is shown that a decrease in drag resulting from an increase in the strength of tangential surface velocity leads to an initial reduction and eventual rise in the power loss coefficient. A maximum in energetic efficiency is attained for a drag reducing tangential surface velocity which minimizes the power loss coefficient. The effect of the tangential surface velocity on drag reduction and self-propulsion of both bluff and streamlined bodies is explored through a variation in the thickness ratio (ratio of the minor and major axes) of the elliptical cylinders.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rigid splitter plates in the wake of bluff bodies are known to suppress the primary vortex shedding. In the present work, we experimentally study the problem of a flexible splitter plate in the wake of a circular cylinder. In this case, the splitter plate is free to continuously deform along its length due to the fluid forces acting on it; the flexural rigidity (EI) of the plate being an important parameter. Direct visualizations of the splitter plate motions, for very low values of flexural rigidity (EI), indicate periodic traveling wave type deformations of the splitter plate with maximum tip amplitudes of the order of I cylinder diameter. As the Reynolds number based on cylinder diameter is varied, two regimes of periodic splitter plate motions are found that are referred to as mode I and mode II, with a regime of aperiodic motions between them. The frequency of plate motions in both periodic modes is found to be close to the plane cylinder Strouhal number of about 0.2, while the average frequencies in the non-periodic regime are substantially lower. The measured normalized phase speed of the traveling wave for both periodic modes is also close to the convection speed of vortices in the plane cylinder wake. As the flexural rigidity of the plate (EI) is increased, the response of the plate was found to shift to the right when plotted with flow speed or Re. To better capture the effect of varying EI, we define and use a non-dimensional bending stiffness, K*, similar to the ones used in the flag flutter problem, K*=EI/(0.5 rho(UL3)-L-2), where U is the free-stream velocity and L is the splitter plate length. Amplitude data for different EI cases when plotted against this parameter appear to collapse on to a single curve for a given splitter plate length. Measurements of the splitter plate motions for varying splitter plate lengths indicate that plates that are substantially larger than the formation length of the plane cylinder wake have similar responses, while shorter plates show significant differences.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present work, we experimentally study and demarcate the stall flutter boundaries of a NACA 0012 airfoil at low Reynolds numbers (Re similar to 10(4)) by measuring the forces and flow fields around the airfoil when it is forced to oscillate. The airfoil is placed at large mean angle of attack (alpha(m)), and is forced to undergo small amplitude pitch oscillations, the amplitude (Delta alpha) and frequency (f) of which are systematically varied. The unsteady loads on the oscillating airfoil are directly measured, and are used to calculate the energy transfer to the airfoil from the flow. These measurements indicate that for large mean angles of attack of the airfoil (alpha(m)), there is positive energy transfer to the airfoil over a range of reduced frequencies (k=pi fc/U), indicating that there is a possibility of airfoil excitation or stall flutter even at these low Re (c=chord length). Outside this range of reduced frequencies, the energy transfer is negative and under these conditions the oscillations would be damped. Particle Image Velocimetry (PIV) measurements of the flow around the oscillating airfoil show that the shear layer separates from the leading edge and forms a leading edge vortex, although it is not very clear and distinct due to the low oscillation amplitudes. On the other hand, the shear layer formed after separation is found to clearly move periodically away from the airfoil suction surface and towards it with a phase lag to the airfoil oscillations. The phase of the shear layer motion with respect to the airfoil motions shows a clear difference between the exciting and the damping case.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper control of oblique vortex shedding in the wake behind a straight circular cylinder is explored experimentally and computationally. Towards this, steady rotation of the cylinder about its axis is used as a control device. Some limited studies are also performed with a stepped circular cylinder, where at the step the flow is inevitably three-dimensional irrespective of the rotation rate. When there is no rotation, the vortex shedding pattern is three dimensional as described in many previous studies. With a non-zero rotation rate, it is demonstrated experimentally as well as numerically that the shedding pattern becomes more and more two-dimensional. At sufficiently high rotation rates, the vortex shedding is completely suppressed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Model free simulations are performed to study the effect of the presence of side wall in compressible mixing of two parallel dissimilar gaseous streams with significant temperature difference. The turbulence statistics shows the three dimensional nature of the flow with and without the presence of side walls. The presence of side wall neither makes the flow field two dimensional, nor suppresses three dimensional disturbances. However, the comparison of shear layer growth rate and wall pressures reveal a better match with the two dimensional simulation results. This better match is explained on the basis of formation of oblique structures due to the presence of side walls which also suppress the distribution of momentum in third direction making the pressures to be higher as compared with the case without side walls. (C) 2013 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In several chemical and space industries, small bubbles are desired for efficient interaction between the liquid and gas phases. In the present study, we show that non-uniform electric field with appropriate electrode configurations can reduce the volume of the bubbles forming at submerged needles by up to three orders of magnitude. We show that localized high electric stresses at the base of the bubbles result in slipping of the contact line on the inner surface of the needle and subsequent bubble formation occurs with contact line inside the needle. We also show that for bubble formation in the presence of highly non-uniform electric field, due to high detachment frequency, the bubbles go through multiple coalescences and thus increase the apparent volume of the detached bubbles. (C) 2013 AIP Publishing LLC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bentonite in slurry walls needs to be amended with organo-clay to control the migration of organic contaminants. Consolidation behaviour of the slurry is important because it will reduce the total effective stress owing to mobilisation of frictional force between the side wall of the trench and the slurry. Compressibility of the slurry of bentonite is expected to undergo significant changes owing to amendment with organo-clay and according to the nature of the fluid. Standard one-dimensional consolidation tests were carried out on slurries of bentonite, organo-clay and their mixtures by remoulding them to their respective liquid limit consistency with water as well as fluids of low polarity, such as carbon tetrachloride, and inundating with different fluids. Organo-clay and its mixture with bentonite when moulded with water exhibit lower compressibility than bentonite in any pore fluid, but their compressibility increases when moulded with carbon tetrachloride and inundated with the same fluid. These changes in the compressibility of bentonite amended with organo-clay are explained by particle rearrangements, changes in the development of the diffuse double layer and contribution from the water adsorbed in the inter-lamellar space of the clay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thermoacoustic prime mover (TAPM) has gained considerable attention as a pressure wave generator to drive pulse tube refrigerator (PTR) due to no moving parts, reasonable efficiency, use of environmental friendly working fluids etc. To drive PTCs, lower frequencies (f) with larger pressure amplitudes (Delta P) are essential, which are affected by geometric and operating parameters of TAPM as well as working fluids. For driving PTRs, a twin standing wave TAPM is built and studied by using different working fluids such as helium, argon, nitrogen and their binary mixtures. Simulation results of DeltaEc are compared with experimental data wherever possible. DeltaEc predicts slightly increased resonance frequencies, but gives larger Delta P and lower temperature difference Delta T across stack. High mass number working fluid leads to lower frequency with larger Delta P, but higher Delta T. Studies indicate that the binary gas mixture of right composition with lower Delta T can be arrived at to drive TAPM of given geometry. (C) 2013 Elsevier Ltd and IIR. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The performance of a two-phase heat transport device such as the loop heat pipe is influenced by the evaporative heat transfer coefficient in the evaporator. From previous experiments with loop heat pipes, it has been observed that fluids with a high heat pipe figure of merit have a high heat transfer coefficient. Considering an evaporating extended thin film, this paper theoretically corroborates this experimental observation by deriving a direct link between the evaporative heat flux at the interface and the fluid figures of merit (namely interline heat flow parameter and heat pipe figure of merit) in the thin film. Numerical experiments with different working fluids clearly show that a fluid with high figure of merit also has a high cumulative heat transfer in the microregion encompassing the evaporating thin film. Thus, a loop heat pipe or heat pipe that uses a working fluid with a high interline heat flow parameter and heat pipe figure of merit will lead to a high evaporative heat transfer coefficient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A droplet introduced in an external convective flow field exhibits significant multimodal shape oscillations depending upon the intensity of the aerodynamic forcing. In this paper, a theoretical model describing the temporal evolution of normal modes of the droplet shape is developed. The fluid is assumed to be weakly viscous and Newtonian. The convective flow velocity, which is assumed to be incompressible and inviscid, is incorporated in the model through the normal stress condition at the droplet surface and the equation of motion governing the dynamics of each mode is derived. The coupling between the external flow and the droplet is approximated to be a one-way process, i.e., the external flow perturbations effect the droplet shape oscillations and the droplet oscillation itself does not influence the external flow characteristics. The shape oscillations of the droplet with different fluid properties under different unsteady flow fields were simulated. For a pulsatile external flow, the frequency spectra of the normal modes of the droplet revealed a dominant response at the resonant frequency, in addition to the driving frequency and the corresponding harmonics. At driving frequencies sufficiently different from the resonant frequency of the prolate-oblate oscillation mode of the droplet, the oscillations are stable. But at resonance the oscillation amplitude grows in time leading to breakup depending upon the fluid viscosity. A line vortex advecting past the droplet, simulated as an isotropic jump in the far field velocity, leads to the resonant excitation of the droplet shape modes if and only if the time taken by the vortex to cross the droplet is less than the resonant period of the P-2 mode of the droplet. A train of two vortices interacting with the droplet is also analysed. It shows clearly that the time instant of introduction of the second vortex with respect to the droplet shape oscillation cycle is crucial in determining the amplitude of oscillation. (C) 2014 AIP Publishing LLC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, we present the characterization and performance studies of self-priming peristaltic pump for drug delivery application. Conventional materials and methods have been used to fabricate single cam mechanism based peristaltic micropump. To control the fluid flow precisely in micro liter range, a single cam mechanism has been used instead of conventional roller mechanism. The fabricated pump is suitable for liquid, gas and foam. Using water as a fluid medium, a flow rate of 12.5 mu l/rpm is achieved using a flexible silicone tube of inner diameter 1.5 mm and outer diameter 2.5 mm. Other than water, higher viscosity fluids showed a decrease in the flow rate. The designed micropump exhibits a linear dependence of flow rate in the voltage range of 2.5V to 5V. Drug delivery using micropump demands that the micropump has to pump against the blood pressure (maximum of 25kPa) with constant flow rate. Here the designed pump is able to pump the liquid with a constant flow rate of 500 mu l/min (water) up to a backpressure of 40kPa. It was observed that, by increasing the backpressure above 40kPa, flow rate of the pump gradually decreased to 125 mu l/min at 120kPa. In addition, Micropump based drug delivery demands that the micropump should be normally in closed condition in all the positions to avoid drug leakage and bleeding. Hence, micropump has been characterized for normally closed condition in all positions (0 degrees to 360 degrees). However, a minute leak of 0.14 % was found for an inlet pressure of 140kPa. Also, the normally closed region with no leak is observed up to 60kPa of pressure in all positions (0 degrees to 360 degrees).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Controlled motion of artificial nanomotors in biological environments, such as blood, can lead to fascinating biomedical applications, ranging from targeted drug delivery to microsurgery and many more. In spite of the various strategies used in fabricating and actuating nanomotors, practical issues related to fuel requirement, corrosion, and liquid viscosity have limited the motion of nanomotors to model systems such as water, serum, or biofluids diluted with toxic chemical fuels, such as hydrogen peroxide. As we demonstrate here, integrating conformal ferrite coatings with magnetic nanohelices offer a promising combination of functionalities for having controlled motion in practical biological fluids, such as chemical stability, cytocompatibility, and the generated thrust. These coatings were found to be stable in various biofluids, including human blood, even after overnight incubation, and did not have significant influence on the propulsion efficiency of the magnetically driven nanohelices, thereby facilitating the first successful ``voyage'' of artificial nanomotors in human blood. The motion of the ``nanovoyager'' was found to show interesting stick-slip dynamics, an effect originating in the colloidal jamming of blood cells in the plasma. The system of magnetic ``nanovoyagers'' was found to be cytocompatible with C2C12 mouse myoblast cells, as confirmed using MTT assay and fluorescence microscopy observations of cell morphology. Taken together, the results presented in this work establish the suitability of the ``nanovoyager'' with conformal ferrite coatings toward biomedical applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The complex multiscale physics of nano-particle laden functional droplets in a reacting environment is of fundamental and applied significance for a wide variety of applications ranging from thermal sprays to pharmaceutics to modern day combustors using new brands of bio-fuels. Formation of homogenous nucleated bubbles at the superheat limit inside vaporizing droplets (with or without nanoparticles) represents an unstable system. Here we show that self-induced boiling in burning functional pendant droplets can produce severe volumetric shape oscillations. Internal pressure build-up due to ebullition activity ejects bubbles from the droplet domain causing undulations on the droplet surface and oscillations in bulk. Through experiments, we establish that the degree of droplet deformation depends on the frequency and intensity of these bubble expulsion events. In a distinct regime of single isolated bubble residing in the droplet, however, pre-ejection transient time is identified by Darrieus-Landau evaporative instability, where bubble-droplet system behaves as a synchronized driver-driven system with bulk bubble-shape oscillations being imposed on the droplet. The agglomeration of nanophase additives modulates the flow structures within the droplet and also influences the bubble inception and growth leading to different levels of instabilities. (C) 2014 AIP Publishing LLC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we investigate the local flame surface statistics of constant-pressure turbulent expanding flames. First the statistics of local length ratio is experimentally determined from high-speed planar Mie scattering images of spherically expanding flames, with the length ratio on the measurement plane, at predefined equiangular sectors, defined as the ratio of the actual flame length to the length of a circular-arc of radius equal to the average radius of the flame. Assuming isotropic distribution of such flame segments we then convolute suitable forms of the length-ratio probability distribution functions (pdfs) to arrive at the corresponding area-ratio pdfs. It is found that both the length ratio and area ratio pdfs are near log-normally distributed and shows self-similar behavior with increasing radius. Near log-normality and rather intermittent behavior of the flame-length ratio suggests similarity with dissipation rate quantities which stimulates multifractal analysis. (C) 2014 AIP Publishing LLC.