920 resultados para Aortic Valve Stenosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ischaemic spinal cord injury (SCI) remains the Achilles heel of open and endovascular descending thoracic and thoracoabdominal repair. Neurological outcomes have improved coincidentially with the introduction of neuroprotective measures. However, SCI (paraplegia and paraparesis) remains the most devastating complication. The aim of this position paper is to provide physicians with broad information regarding spinal cord blood supply, to share strategies for shortening intraprocedural spinal cord ischaemia and to increase spinal cord tolerance to transitory ischaemia through detection of ischaemia and augmentation of spinal cord blood perfusion. This study is meant to support physicians caring for patients in need of any kind of thoracic or thoracoabdominal aortic repair in decision-making algorithms in order to understand, prevent or reverse ischaemic SCI. Information has been extracted from focused publications available in the PubMed database, which are cohort studies, experimental research reports, case reports, reviews, short series and meta-analyses. Individual chapters of this position paper were assigned and after delivery harmonized by Christian D. Etz, Ernst Weigang and Martin Czerny. Consequently, further writing assignments were distributed within the group and delivered in August 2014. The final version was submitted to the EJCTS for review in September 2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A one-year-old healthy sheep received an implant stenting the mural ('posterior') leaflet of the mitral valve. The experiment was authorized by the Cantonal Ethical Committee. The surgery was performed on the open, beating heart during cardiopulmonary bypass (CPB). Management of anaesthesia was based on isoflurane with mechanical intermittent positive pressure ventilation (IPPV) of the lungs, combined with intercostal nerve blocks and intravenous fentanyl and lidocaine. Marked cardiovascular depression occurred towards the end of CPB time and required high doses of dopamine, dobutamine, lidocaine and ephedrine to allow for weaning off the CPB pump. Moreover, severe pulmonary dysfunction developed when IPPV was re-initiated after CPB. Hypoxaemia persisted throughout the recovery from general anaesthesia. Multiple organ failure developed gradually during the three postoperative days, leading to euthanasia of the animal. As described in this case, marked lung injury associated with some degree of failure of other vital organs may occur in sheep after CPB. Intraoperative cardiorespiratory complications when weaning-off may indicate the development of 'post-pump syndrome'.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Since the initial publication in 2000, Angiotensin II-infused mice have become one of the most popular models to study abdominal aortic aneurysm in a pre-clinical setting. We recently used phase contrast X-ray based computed tomography to demonstrate that these animals develop an apparent luminal dilatation and an intramural hematoma, both related to mural ruptures in the tunica media in the vicinity of suprarenal side branches. AIMS The aim of this narrative review was to provide an extensive overview of small animal applicable techniques that have provided relevant insight into the pathogenesis and morphology of dissecting AAA in mice, and to relate findings from these techniques to each other and to our recent PCXTM-based results. Combining insights from recent and consolidated publications we aimed to enhance our understanding of dissecting AAA morphology and anatomy. RESULTS AND CONCLUSION We analyzed in vivo and ex vivo images of aortas obtained from macroscopic anatomy, histology, high-frequency ultrasound, contrast-enhanced micro-CT, micro-MRI and PCXTM. We demonstrate how in almost all publications the aorta has been subdivided into a part in which an intact lumen lies adjacent to a remodeled wall/hematoma, and a part in which elastic lamellae are ruptured and the lumen appears to be dilated. We show how the novel paradigm fits within the existing one, and how 3D images can explain and connect previously published 2D structures. We conclude that PCXTM-based findings are in line with previous results, and all evidence points towards the fact that dissecting AAAs in Angiotensin II-infused mice are actually caused by ruptures of the tunica media in the immediate vicinity of small side branches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS Transcatheter mitral valve replacement (TMVR) is an emerging technology with the potential to treat patients with severe mitral regurgitation at excessive risk for surgical mitral valve surgery. Multimodal imaging of the mitral valvular complex and surrounding structures will be an important component for patient selection for TMVR. Our aim was to describe and evaluate a systematic multi-slice computed tomography (MSCT) image analysis methodology that provides measurements relevant for transcatheter mitral valve replacement. METHODS AND RESULTS A systematic step-by-step measurement methodology is described for structures of the mitral valvular complex including: the mitral valve annulus, left ventricle, left atrium, papillary muscles and left ventricular outflow tract. To evaluate reproducibility, two observers applied this methodology to a retrospective series of 49 cardiac MSCT scans in patients with heart failure and significant mitral regurgitation. For each of 25 geometrical metrics, we evaluated inter-observer difference and intra-class correlation. The inter-observer difference was below 10% and the intra-class correlation was above 0.81 for measurements of critical importance in the sizing of TMVR devices: the mitral valve annulus diameters, area, perimeter, the inter-trigone distance, and the aorto-mitral angle. CONCLUSIONS MSCT can provide measurements that are important for patient selection and sizing of TMVR devices. These measurements have excellent inter-observer reproducibility in patients with functional mitral regurgitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transcatheter mitral interventions has been developed to address an unmet clinical need and may be an alternative therapeutic option to surgery with the intent to provide symptomatic and prognostic benefit. Beyond MitraClip therapy, alternative repair technologies are being developed to expand the transcatheter intervention armamentarium. Recently, the feasibility of transcatheter mitral valve implantation in native non-calcified valves has been reported in very high-risk patients. Acknowledging the lack of scientific evidence to date, it is difficult to predict what the ultimate future role of transcatheter mitral valve interventions will be. The purpose of the present report is to review the current state-of-the-art of mitral valve intervention, and to identify the potential future scenarios, which might benefit most from the transcatheter repair and replacement devices under development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gebiet: Kardiologie Abstract: OBJECTIVES: Severe neurologiCal defiCit (ND) due to aCute aortiC disseCtion type A (AADA) was Considered a ContraindiCation for surgery beCause of poor prognosis. ReCently, more aggressive indiCation for surgery despite neurologiCal symptoms has shown aCCeptable – postoperative CliniCal results. The aim of this study was to evaluate early and mid-term outComes of patients with AADA presenting with aCute ND. – – METHODS: Data from 53 patients with new-onset ND who reCeived surgiCal repair for AADA between 2005 and 2012 at our institution were retrospeCtively reviewed. ND was defined as foCal motor or sensory defiCit, hemiplegia, paraplegia, Convulsions or Coma. NeurologiCal symptoms were evaluated preoperatively using the Glasgow Coma SCale (GCS) and modified Rankin SCale (mRS), and at disCharge as well as 3–6 months postoperatively using the mRS and National Institutes of Health Stroke SCale. Involvement of Carotid arteries was assessed in the pre- and postoperative Computed tomography. LogistiC regression analysis was performed to deteCt prediCtive faCtors for reCovery of ND. – – RESULTS: Of the 53 patients, 29 (54.7%) showed Complete reCovery from foCal ND at follow-up. NeurologiCal symptoms persisted in 24 (45.3%) patients, of whiCh 8 (33%) died without neurologiCal assessment at follow-up. Between the two groups (patients with reCovery and – those with persisting ND), there was no signifiCant differenCe regarding the duration of hypothermiC CirCulatory arrest (28 ± 14 vs 36 ± 20 min) or severely reduCed ConsCiousness (GCS <8). Multivariate analysis showed signifiCant differenCes for the preoperative mRS between the two groups (P < 0.007). A high preoperative mRS was assoCiated with persistenCe of neurologiCal symptoms (P < 0.02). CardiovasCular risk faCtors, age or involvement of supra-aortiC branChes were not prediCtive for persistenCe of ND. – – CONCLUSION: More than half of our patients reCovered Completely from ND due to AADA after surgery. Severity of CliniCal symptoms had a prediCtive value. Patients suffering from AADA and presenting with ND before surgery should not be exCluded from emergenCy surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE This study aims to report the management of patients with spontaneous isolated dissection of the abdominal aorta (sIAAD). METHODS A cohort of 18 consecutive patients (12 male, mean age 58 years) with sIAAD was treated between 1990 and 2009. Dissection was asymptomatic in ten and symptomatic in eight patients. Retrospective data analysis from patient charts was performed. Follow-up included clinical examination, ultrasound, and/or CT-angiography. Mean follow-up was 54 months (range 1-211). RESULTS In total, eight out of 18 received invasive treatment. All asymptomatic patients initially underwent conservative treatment and surveillance. Spontaneous false lumen thrombosis occurred in four (40 %), and three patients showed relevant aneurysmatic progression and underwent elective invasive treatment (open n = 2, endovascular n = 1), representing a crossover rate of 30 %. Late mortality was 20 % (n = 2) in this group. In symptomatic patients, five underwent urgent treatment due to persistent abdominal or back pain (n = 4) or contained rupture (n = 1); one was treated for claudication. The remaining two patients presented with irreversible spinal cord ischemia and were treated conservatively. Three patients were treated by open surgery and three by endovascular interventions (two stentgrafts, one Palmaz XXL stent). Early and late morbidity and mortality was 0 % in this group. There were no reinterventions CONCLUSION: The majority of patients with sIADD require invasive treatment, with EVAR being the preferable treatment option today. In asymptomatic IADD, primary surveillance is justifiable, but close surveillance due to expansion is necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM To identify morphologic factors affecting aortic expansion in patients with uncomplicated type B aortic dissections. METHODS Computed tomography data of 24 patients (18 male; median age: 61 years), diagnosed with acute uncomplicated type B aortic dissections between 2002 and 2013, were retrospectively reviewed. All patients had at least two computed tomography angiography scans and six months of uneventful follow-up. Computed tomography scans were assessed by two independent readers with regard to presence and number of entry tears. Thoracic and abdominal aortic diameters were derived using image processing software. RESULTS Twenty-two of 24 patients showed aortic expansion over a median computed tomography angiographic follow-up of 33.2 months. Annual rates showed an increase of 1.7 mm for total aortic diameter, 2.1 mm for the false and a decrease of -0.4 mm for the true lumen. In three patients (12.5%), aortic diameter exceeded 60 mm during follow-up, and all three patients underwent thoracic endovascular aortic repair. Patients with a maximum aortic diameter <4 cm at baseline showed a significantly higher expansion rate compared to cases with an initial maximum aortic diameter of ≥4 cm (p=0.0471). A median of two entries (range: 1-5) was recognized per patient. Presence of more than two entry tears (n = 13) was associated with faster overall diameter expansion (mean annual rates: 2.18 mm vs. 1.16 mm; p = 0.4556), and decrease of the cross-sectional surface of the true lumen over time (annual rate for > 2 entries vs. ≤2 entries: -7.8 mm(2) vs. +37.5 mm(2); p = 0.0369). Median size of entry tears was 12 mm (range: 2-53 mm). CONCLUSIONS The results presented herein suggest that uncomplicated type B aortic dissection patients with more than two entry tears and/or an initial maximum aortic diameter of<4 cm are at risk for aortic dilatation and, therefore, may require stricter follow-up including the possible need for early intervention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE The purpose of this study was to identify morphologic factors affecting type I endoleak formation and bird-beak configuration after thoracic endovascular aortic repair (TEVAR). METHODS Computed tomography (CT) data of 57 patients (40 males; median age, 66 years) undergoing TEVAR for thoracic aortic aneurysm (34 TAA, 19 TAAA) or penetrating aortic ulcer (n = 4) between 2001 and 2010 were retrospectively reviewed. In 28 patients, the Gore TAG® stent-graft was used, followed by the Medtronic Valiant® in 16 cases, the Medtronic Talent® in 8, and the Cook Zenith® in 5 cases. Proximal landing zone (PLZ) was in zone 1 in 13, zone 2 in 13, zone 3 in 23, and zone 4 in 8 patients. In 14 patients (25%), the procedure was urgent or emergent. In each case, pre- and postoperative CT angiography was analyzed using a dedicated image processing workstation and complimentary in-house developed software based on a 3D cylindrical intensity model to calculate aortic arch angulation and conicity of the landing zones (LZ). RESULTS Primary type Ia endoleak rate was 12% (7/57) and subsequent re-intervention rate was 86% (6/7). Left subclavian artery (LSA) coverage (p = 0.036) and conicity of the PLZ (5.9 vs. 2.6 mm; p = 0.016) were significantly associated with an increased type Ia endoleak rate. Bird-beak configuration was observed in 16 patients (28%) and was associated with a smaller radius of the aortic arch curvature (42 vs. 65 mm; p = 0.049). Type Ia endoleak was not associated with a bird-beak configuration (p = 0.388). Primary type Ib endoleak rate was 7% (4/57) and subsequent re-intervention rate was 100%. Conicity of the distal LZ was associated with an increased type Ib endoleak rate (8.3 vs. 2.6 mm; p = 0.038). CONCLUSIONS CT-based 3D aortic morphometry helps to identify risk factors of type I endoleak formation and bird-beak configuration during TEVAR. These factors were LSA coverage and conicity within the landing zones for type I endoleak formation and steep aortic angulation for bird-beak configuration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess spatial and temporal pressure characteristics in patients with repaired aortic coarctation compared to young healthy volunteers using time-resolved velocity-encoded three-dimensional phase-contrast magnetic resonance imaging (4D flow MRI) and derived 4D pressure difference maps. After in vitro validation against invasive catheterization as gold standard, 4D flow MRI of the thoracic aorta was performed at 1.5T in 13 consecutive patients after aortic coarctation repair without recoarctation and 13 healthy volunteers. Using in-house developed processing software, 4D pressure difference maps were computed based on the Navier-Stokes equation. Pressure difference amplitudes, maximum slope of pressure amplitudes and spatial pressure range at mid systole were retrospectively measured by three readers, and twice by one reader to assess inter- and intraobserver agreement. In vitro, pressure differences derived from 4D flow MRI showed excellent agreement to invasive catheter measurements. In vivo, pressure difference amplitudes, maximum slope of pressure difference amplitudes and spatial pressure range at mid systole were significantly increased in patients compared to volunteers in the aortic arch, the proximal descending and the distal descending thoracic aorta (p < 0.05). Greatest differences occurred in the proximal descending aorta with values of the three parameters for patients versus volunteers being 19.7 ± 7.5 versus 10.0 ± 2.0 (p < 0.001), 10.9 ± 10.4 versus 1.9 ± 0.4 (p = 0.002), and 8.7 ± 6.3 versus 1.6 ± 0.9 (p < 0.001). Inter- and intraobserver agreements were excellent (p < 0.001). Noninvasive 4D pressure difference mapping derived from 4D flow MRI enables detection of altered intraluminal aortic pressures and showed significant spatial and temporal changes in patients with repaired aortic coarctation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE The aim of this study was to evaluate the utility of cardiac postmortem magnetic resonance (PMMR) to perform routine measurements of the ventricular wall thicknesses and the heart valves and to assess if imaging measurements are consistent with traditional autopsy measurements. METHODS In this retrospective study, 25 cases with cardiac PMMR and subsequent autopsy were included. The thicknesses of the myocardial walls as well as the circumferences of all heart valves were measured on cardiac PMMR and compared to autopsy measurements. Paired samples T-test and the Wilcoxon-Signed rank test, were used to compare autopsy and cardiac PMMR measurements. For exploring correlations, the Pearson's Correlation coefficient and the Spearman's Rho test were used. RESULTS Cardiac PMMR measurements of the aortic and pulmonary valve circumferences showed no significant differences from autopsy measurements. The mitral and tricuspid valves circumferences differed significantly from autopsy measurements. Left myocardial and right myocardial wall thickness also differed significantly from autopsy measurements. Left and right myocardial wall thickness, and tricuspid valve circumference measurements on cardiac PMMR and autopsy, correlated strongly and significantly. CONCLUSION Several PMMR measurements of cardiac parameters differ significantly from corresponding autopsy measurements. However, there is a strong correlation between cardiac PMMR measurements and autopsy measurements in the majority of these parameters. It is important to note that myocardial walls are thicker when measured in situ on cardiac PMMR than when measured at autopsy. Investigators using post-mortem MR should be aware of these differences in order to avoid false diagnoses of cardiac pathology based on cardiac PMMR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this study was to assess whether epicardial and paracardial adipose tissue volumes, as determined by computed tomography (CT), correlate with coronary artery stenosis as determined by autopsy. The postmortem CT data and autopsy findings of 116 adult human decedents were retrospectively compared. Subjects were classified into three groups according to their degree of coronary artery stenosis: ≥50, <50%, and no stenosis. Epicardial and paracardial adipose tissue volumes were calculated based on manual segmentation after threshold based masking. In addition, epicardial adipose tissue thickness was measured using a caliper. All three parameters (thickness of epicardial fat and volumes of both epicardial and paracardial fat) were compared among the three groups and correlated with the degree of coronary artery stenosis. The group with no coronary artery stenosis showed the lowest mean values of epicardial adipose tissue volume, while the coronary artery stenosis ≥50 % group showed the highest volume. All measured variables (thickness of epicardial fat and volumes of both epicardial and paracardial fat) correlated significantly with the grade of coronary artery stenosis, even after controlling for BMI, however, epicardial adipose tissue volume exhibited the strongest correlation. This study reveals that there is an association between the degree of coronary artery stenosis and the amount of epicardial fat tissue: The larger the volume of epicardial fat, the higher the degree of coronary artery stenosis.