992 resultados para Anderson, Benedict
Resumo:
The Wiskott-Aldrich syndrome (WAS) is a rare X-linked primary immunodeficiency characterized by recurrent infections, thrombocytopenia, eczema, and high incidence of malignancy and autoimmunity. The cellular mechanisms underlying autoimmune complications in WAS have been extensively studied; however, they remain incompletely defined. We investigated the characteristics of IL-10-producing CD19+CD1dhighCD5+ B cells (CD1dhighCD5+ Breg) obtained from Was gene knockout (WKO) mice and found that their numbers were significantly lower in these mice compared to wild type (WT) controls. Moreover, we found a significant age-dependent reduction of the percentage of IL-10-expressing cells in WKO CD1dhighCD5+ Breg cells as compared to age-matched WT control mice. CD1dhighCD5+ Breg cells from older WKO mice did not suppress the in vitro production of inflammatory cytokines from activated CD4+ T cells. Interestingly, CD1dhighCD5+ Breg cells from older WKO mice displayed a basal activated phenotype which may prevent normal cellular responses, among which is the expression of IL-10. These defects may contribute to the susceptibility to autoimmunity with age in patients with WAS.
Resumo:
Neste trabalho avaliou-se o produto dose área e estimou-se a dose na entrada da pele em exames pediátricos, cujos resultados mostraram valores, em média, 100% acima do adotado como referência para a realização deste trabalho (0,070 mGy). Simultaneamente, fez-se a aferição dos parâmetros técnicos dos equipamentos usados para a obtenção das imagens radiográficas. Os resultados revelaram que o desempenho dos equipamentos está de acordo com a legislação sanitária vigente. Logo, as doses elevadas foram atribuídas ao emprego de técnicas de baixa tensão e à falta de especialização para a realização de exames pediátricos. Realizaram-se medidas das doses absorvidas na região gonadal durante as exposições radiográficas utilizando-se dosímetros termoluminescentes, que se mostraram inadequados para a obtenção destas medidas. Usou-se então uma câmara de ionização e os valores obtidos revelaram que as doses absorvidas sobre a região gonadal estão abaixo dos limites que poderiam causar esterilidade temporária ou permanente.
Resumo:
OBJETIVO: Avaliar o valor prognóstico da distensão de alças intestinais observada em radiografias na evolução e mortalidade de neonatos com enterocolite necrosante. MATERIAIS E MÉTODOS: Nas radiografias de abdome de 53 pacientes obtidas no momento da suspeita diagnóstica de enterocolite necrosante, foi realizada a medida do diâmetro da alça mais distendida (AD), assim como a distância entre a borda superior da primeira vértebra lombar e a borda inferior da segunda (L1-L2), a distância entre as bordas laterais dos pedículos da primeira vértebra lombar (L1), e foram estabelecidas as associações entre AD/L1-L2 e AD/L1. Esta medida foi considerada como possível determinante de potenciais complicações, intervenção cirúrgica e mortalidade. RESULTADOS: Os pacientes que necessitaram de tratamento cirúrgico, aqueles que tiveram complicações durante a evolução e aqueles que morreram da doença tiveram a relação entre AD e AD/L1-L2 maiores (p < 0,05). Os valores de AD/L1 e a localização da alça mais distendida não foram diferentes nos grupos com evolução desfavorável. CONCLUSÃO: Distensão de alça intestinal detectada em radiografias de abdome realizadas na admissão sugerem pior prognóstico em enterocolite necrosante. Outrossim, medidas do diâmetro da alça mais distendida nessas radiografias são um método simples e reprodutível que oferece informações diagnósticas e prognósticas.
Resumo:
PURPOSE: Pediatric rhabdomyosarcoma (RMS) has two common histologic subtypes: embryonal (ERMS) and alveolar (ARMS). PAX-FOXO1 fusion gene status is a more reliable prognostic marker than alveolar histology, whereas fusion gene-negative (FN) ARMS patients are clinically similar to ERMS patients. A five-gene expression signature (MG5) previously identified two diverse risk groups within the fusion gene-negative RMS (FN-RMS) patients, but this has not been independently validated. The goal of this study was to test whether expression of the MG5 metagene, measured using a technical platform that can be applied to routine pathology material, would correlate with outcome in a new cohort of patients with FN-RMS. EXPERIMENTAL DESIGN: Cases were taken from the Children's Oncology Group (COG) D9803 study of children with intermediate-risk RMS, and gene expression profiling for the MG5 genes was performed using the nCounter assay. The MG5 score was correlated with clinical and pathologic characteristics as well as overall and event-free survival. RESULTS: MG5 standardized score showed no significant association with any of the available clinicopathologic variables. The MG5 signature score showed a significant correlation with overall (N = 57; HR, 7.3; 95% CI, 1.9-27.0; P = 0.003) and failure-free survival (N = 57; HR, 6.1; 95% CI, 1.9-19.7; P = 0.002). CONCLUSIONS: This represents the first, validated molecular prognostic signature for children with FN-RMS who otherwise have intermediate-risk disease. The capacity to measure the expression of a small number of genes in routine pathology material and apply a simple mathematical formula to calculate the MG5 metagene score provides a clear path toward better risk stratification in future prospective clinical trials. Clin Cancer Res; 21(20); 4733-9. ©2015 AACR.
Resumo:
Os autores relatam um caso de abordagem mista para o tratamento endovascular de doença oclusiva da artéria tibial anterior por acesso pedioso retrógrado, no qual a abordagem tradicional anterógrada foi inadequada em vencer uma oclusão. A técnica parece oferecer uma opção para procedimentos endovasculares, que objetivam o tratamento de lesões da artéria tibial anterior em que a via anterógrada convencional mostre-se inadequada.
Resumo:
Results on the optimization of analytical methods for the determination of phosphorus in phosphino-polycarboxylate (PPCA), used frequently as scale inhibitor during oil production, by ICP-AES and ICP-MS are presented. Due to the complex matrix of production waters (brines) and their high concentration in inorganic phosphorus, the separation of organic phosphorus prior to its determination is necessary. In this work, minicolumns of silica immobilized C18 were used. Optimization of the separation step resulted in the following working conditions: (1) prewashing of the column with methanol (80% v/v); (2) use of a flow rate of 5 mL/min and 10 mL/min, respectively, for the preconditioning step and for percolation of the water sample; (3) final elution of organic phosphorus with 7 mL of buffer of H3BO3/NaOH (0.05 M, pH 9) with a flow rate of 1 mL/min. Sample detection limits (3s) for different combinations of nebulizers and spectrometric methods, based on 10 mL water aliquots, are: ICP-AES -Cross flow (47 mg/L) and Ultrasonic (18 mug/L); ICP-MS -Cross flow (1.2 mug/L), Cyclonic (0.7 mug/L) and Ultrasonic (0.5 mug/L). Typical recoveries of organic phosphorus are between 90 and 95% and the repeatability of the whole procedure is better than 10%. The developed methodology was applied successfully to samples from the oil-well NA 46, platform PNA 2, Campos basin, Brazil. Assessment of the PPCA inhibitor was possible at lower concentrations than achieved by current analytical methods, resulting in benefits such as reduced cost of chemicals, postponed oil production and lower environmental impacts.
Resumo:
This work describes the construction of a home-made low-cost reactor, using easily available materials, capable of destroying efficiently dissolved organic matter. Just 30 minutes of irradiation were sufficient to destroy more than 99% of the humic acids present in a solution of 4 mg C L-1. Copper speciation was evaluated in natural waters of different salinities to test the reactor's efficiency in destroying organically complexed metal species. The effect of the organic matter concentration, salinity, dissolved oxygen and temperature in the photo-oxidation process is discussed.
Contribuição ao estudo de uma metodologia alternativa para obtenção de dioxissulfeto de terras raras
Resumo:
In the last decade, many method has been developed to obtain oxysufides. However, theses materials were obtained by reaction involved gaseous toxics, CO, CS2, H2S and S. In the present work, the synthesis of lanthanum oxysufides actived by europium (III) through an alternative method has been made. This method involve the rare earth sulfate reduction under an atmosphere of argon contained 10% hydrogen using the thermogravimetric technique. The results showed the formation of the phase TR2O2S (TR = La and Eu) at temperatures which depend upon the heating rate, respectively 650 - 830ºC at 5ºC min-1 and 680 - 800ºC at 10ºC min-1. The oxysufides obtained are characterized by infrared spectroscopy. The method developed is more economic than the usual industrial methods and the environmental problems during the synthesis are also better controled.
Resumo:
The fundaments of the modern Density Functional Theory (DFT), its basic theorems, principles and methodology are presented. This review also discuss important and widely used concepts in chemistry but that had not been precisely defined until the development of the DFT. These concepts were proposed and used from an empirical base, but now their precise definition are well established in the DFT formalism. Concepts such as chemical potential (electronegativity), hardness, softness and Fukui function are presented and their consequences to the understanding of chemical reactivity are discussed.
Resumo:
The present paper aims to bring under discussion some theoretical and practical aspects about the proposition, validation and analysis of QSAR models based on multiple linear regression. A comprehensive approach for the derivation of extrathermodynamic equations is reviewed. Some examples of QSAR models published in the literature are analyzed and criticized.
Resumo:
The comparative QSAR is a tool for validating any statistical model that seems to be reasonable in describing an interaction between a bioactive new chemical entity, BIONCE, and the biological system. In order to deeper the understanding of the relationships and the meaning of parameters within the model it is necessary some kind of lateral validation. This validation can be accomplished by chemical procedures using physicochemical organic reactions and by means of biological systems. In this paper we review some of such comparisons and also present a lateral validation between the same set of antimicrobial hydrazides acting against Saccharomyces cerevisiae yeast and Escherichia coli bacterium cells. QSARs are presented to shed light in this important way of stating that the QSAR model is not the endpoint, but the beginning.
Resumo:
In this review it is presented some aspects of electrothermal atomic absorption spectrometry with tungsten coil (ETAW-AAS) since its beginning until the present days as well as the perspectives for this technique. Some aspects concerning its development and theoretical concepts are discussed. The analytical figures of merit such as limit of detection (LD), characteristic mass (m0), relative standard deviation (RSD), accuracy and precision are evaluated, compared and discussed considering published works. It is also evaluated its advantages, applications, limitations and instrumental development. The use of diode laser as radiation source and its perspectives to ETAW are also discussed.
Resumo:
The process of building mathematical models in quantitative structure-activity relationship (QSAR) studies is generally limited by the size of the dataset used to select variables from. For huge datasets, the task of selecting a given number of variables that produces the best linear model can be enormous, if not unfeasible. In this case, some methods can be used to separate good parameter combinations from the bad ones. In this paper three methodologies are analyzed: systematic search, genetic algorithm and chemometric methods. These methods have been exposed and discussed through practical examples.
Resumo:
Probably one of the most difficult and challenging aspects of measuring trace metals in natural waters is to avoid contamination during sampling, manipulation and analysis. This work discusses how to avoid contamination using simple procedures, and considers alternative methods to purify deionised water and low grade reagents to enable accurate determination of trace metals in natural waters in a common laboratory. Measurements were performed by cathodic stripping voltammetry and copper was used as a model metal to test the procedures. It was possible to evaluate copper speciation in natural waters even when total dissolved copper concentration was as low as 1.5 nmol L-1. The methods' accuracy was confirmed by analysis of certified seawater.