977 resultados para Adjustable flow oil pump


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fluid-flow pattern and residence-time distribution (r.t.d.) of the fluid in a continuous casting mould have been studied using a water model. The two recirculating zones below the discharge ports have been found to be asymmetric. The effect of casting speed, discharge port diameter, shroud well depth and the immersion depth on r.t.d. have been investigated. The r.t.d. curve has been well represented by a model of two backmix cells of equal volume in series. The exist of the fluid has been found to be non-uniform across the cross-section of the mould. The fluid-flow pattern has been observed to change with time in a random fashion. Dead volume of upto 31.8% has been found with smaller discharge ports.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have discussed here the flow of a dilute suspension of rigid particles in Newtonian fluid in slowly varying tubes characterized by a small parameter ε. Solutions are presented in the form of asymptotic expansions in powers of ε. The effect of the suspension on the fluid is described by two parameters β and γ which depend on the volume fraction of the particles which we assume to be small. It is found that the presence of the particles accelerate the process of eddy formation near the constriction and shifts the point of separation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oxygen transfer rate and the corresponding power requirement to operate the rotor are vital for design and scale-up of surface aerators. The aeration process can be analyzed in two ways such as batch and continuous systems. The process behaviors of batch and continuous flow systems are different from each other. The experimental and numerical results obtained through the batch systems cannot be relied on and applied for the designing of the continuous aeration tank. Based on the experimentation on batch and continuous type systems, the present work compares the performance of both the batch and continuous surface aeration systems in terms of their oxygen transfer capacity and power consumption. A simulation equation developed through experimentation has shown that continuous flow surface aeration systems are taking more energy than the batch systems. It has been found that batch systems are economical and better for the field application but not feasible where large quantity of wastewater is produced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The unsteady two-dimensional laminar mixed convection flow in the stagnation region of a vertical surface has been studied where the buoyancy forces are due to both the temperature and concentration gradients. The unsteadiness in the flow and temperature fields is caused by the time-dependent free stream velocity. Both arbitrary wall temperature and concentration, and arbitrary surface heat and mass flux variations have been considered. The Navier-Stokes equations, the energy equation and the concentration equation, which are coupled nonlinear partial differential equations with three independent variables, have been reduced to a set of nonlinear ordinary differential equations. The analysis has also been done using boundary layer approximations and the difference between the solutions has been discussed. The governing ordinary differential equations for buoyancy assisting and buoyancy opposing regions have been solved numerically using a shooting method. The skin friction, heat transfer and mass transfer coefficients increase with the buoyancy parameter. However, the skin friction coefficient increases with the parameter lambda, which represents the unsteadiness in the free stream velocity, but the heat and mass transfer coefficients decrease. In the case of buoyancy opposed flow, the solution does not exist beyond a certain critical value of the buoyancy parameter. Also, for a certain range of the buoyancy parameter dual solutions exist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The low frequency dielectric behavior of castor oil (a vegetable oil) has been analyzed quite exhaustively in the context of its application as impregnant in capacitors. For the sake of completeness and in order to understand the relaxation phenomena in this liquid dielectric, this high frequency dielectric study was undertaken. In order to compare its properties with a liquid dielectric used in similar application and whose high frequency behavior has been quite well analyzed, Arochlor 1476 was studied. It is observed that both liquids have distributed relaxation times. The distribution parameters together with the two distinct relaxation times have been calculated by measuring the average relaxation time. It has been found that the distinct relaxation times thus calculated represent the dielectric behavior quite satisfactorily. The average dipole moments, dipole radii and thermal activation energies for dipole relaxation have also been evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amongv arioums ethodtsh,e t ransmissliionne o r thei mpedantcueb em ethohda sb eenm ospt opulafro r thee xperimenetavla luatioonf thea cousticiaml pedanocef a terminatioTnh. ee xistinmg ethodisn,c luding theo nesre porteeda rlierb, y thea uthorrse quirleo catioonf thes oundp ressumrei nima nd/orm axima, or elsem akeu se0 f somei terativep rocedureTsh. e presenpt aperd ealsw ith a methodo f analysios f standinwga vews hichd oesn otd epenodn anyo f thesein volvepdr ocedureIts i.s applicabtloe thec aseo f stationarays w ella sm ovingm ediaI.t enableosn to evaluatteh e impedancoef anyp assivbel ackb ox,a s well as the aeroacoustcich aracteristicosf a sourceo f pulsatingg asf low, with the leaste xperimentawl ork andc omputatiotinm ea ndw itht hee xtraa dvantagoef usinga givenim pedanctueb ef or wavelengtahss largea s fourt imesit s lengthA. methodo f externaml easuremenntost, involvinugs eo f anyi mpedance tubef, or evaluatintgh ea eroacouscthica racteristoicf as sourcoef pulsatingga sf lowi s alsod ealtw ith, based on the definition of attenuation or insertion loss of a muffler.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the existing traditional solar cookers, the cooking is performed near the collector which may be at an inconvenient location for cooking purposes. This paper proposes a hybrid solar cooking system where the solar energy is brought to the kitchen. The energy source is a combination of the solar thermal energy and the Liquefied Petroleum Gas (LPG) that is very common in kitchens. The solar thermal energy is transferred to the kitchen by means of a circulating fluid like oil. The transfer of solar heat is a two fold process wherein the energy from the collector is transferred first to an intermediate energy storage tank and then the energy is subsequently transferred from the tank to the cooking load. There are three parameters that are controlled in order to maximize the energy transfer from the collector to the load viz. the fluid flow rate from collector to tank, fluid flow rate from tank to load and the diameter of the pipes. The entire system is modeled using the bond graph approach. This paper discusses the implementation of such a system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper deals with the flow and heat-transfer problem of a steady axisymmetric laminar incompressible boundary layer swirling flow of a fluid through a conical hydrocyclone. The implicit finitedifference scheme is used to solve the partial differential equations governing the flow. The effect of swirl is found to be more pronounced on the longitudinal skin friction than on the tangential skin friction and heat transfer. The skin friction and heat transfer increase with swirl or with longitudinal distance. Swirl also gives rise to velocity overshoot in the longitudinal velocity profiles and the magnitude of the velocity overshoot increases as the swirl parameter increases. The results are found to be in good agreement with those of the local nonsimilarity and momentum integral methods but they differ appreciably from those of the local similarity method except for the longitudinal skin friction which is fairly in good agreement with that of the local similarity method.Die Arbeit beschäftigt sich mit der Strömung und dem Wärmeübergang in einem konischen Zyklon unter der Voraussetzung stationärer, achsensymmetrischer, laminarer, inkompressibler Grenzschichtströmung. Ein implizites Differenzenverfahren wird benutzt, um die partiellen Differentialgleichungen zu lösen. Der Einfluß des Dralls ist besonders ausgeprägt auf die longitudinale Komponente der Oberflächenreibung, weniger dagegen bei der tangentialen Komponente und beim Wärmeübergang. Die Oberflächenreibung und der Wärmeübergang nehmen zu mit dem Drall, sowie mit dem longitudinalen Abstand. Der Drall erzeugt ein Überschießen der Geschwindigkeit in der longitudinalen Abstand. Der Drall erzeugt ein Überschießen der Geschwindigkeit in der Längsrichtung. Die Größe des Überschusses nimmt mit wachsendem Drallparameter zu. Die Resultate stimmen gut mit den Ergebnissen der Theorie der lokalen Nichtähnlichkeit und der Impulsintegralmethode überein. Dagegen weichen sie mit Ausnahme der longitudinalen Komponente der Oberflächenreibung beträchtlich von den Resultaten der Theorie der lokalen Ähnlichkeit ab.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Six models (Simulators) are formulated and developed with all possible combinations of pressure and saturation of the phases as primary variables. A comparative study between six simulators with two numerical methods, conventional simultaneous and modified sequential methods are carried out. The results of the numerical models are compared with the laboratory experimental results to study the accuracy of the model especially in heterogeneous porous media. From the study it is observed that the simulator using pressure and saturation of the wetting fluid (PW, SW formulation) is the best among the models tested. Many simulators with nonwetting phase as one of the primary variables did not converge when used along with simultaneous method. Based on simulator 1 (PW, SW formulation), a comparison of different solution methods such as simultaneous method, modified sequential and adaptive solution modified sequential method are carried out on 4 test problems including heterogeneous and randomly heterogeneous problems. It is found that the modified sequential and adaptive solution modified sequential methods could save the memory by half and as also the CPU time required by these methods is very less when compared with that using simultaneous method. It is also found that the simulator with PNW and PW as the primary variable which had problem of convergence using the simultaneous method, converged using both the modified sequential method and also using adaptive solution modified sequential method. The present study indicates that pressure and saturation formulation along with adaptive solution modified sequential method is the best among the different simulators and methods tested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A numerical analysis of flow to a dug well in an unconfined aquifer is made, taking into account well storage, elastic storage release, gravity drainage, anisotropy, partial penetration, vertical flow and seepage surface at the well face, and treating the water table in the aquifer and water level in the well as unknown boundaries. The pumped discharge is maintained constant. The solution is obtained by a two-level iterative scheme. The effects of governing parameters on the drawdown, development of seepage surface and contribution from aquifer flow to the total discharge are discussed. The degree of anisotropy and partial penetration are found to be the parameters which affect the flow characteristics most significantly. The effect of anisotropy on the development of seepage surface is very pronounced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some errors have been observed in the analytical expression for the resistance to flow (lambda R), and in the computation of shear stress distribution (tau R) in the analysis of Prawal Sinha and Chandan Singh (1). These errors have been rectified in the present analysis. Also, better values have been suggested for the couple stress parameter alpha for getting better results for lambda R and tau R.