1000 resultados para Adaptation théâtrale


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Sealing ability and bond strengths of total-etch and self-etch dentin adhesives used for immediate dentin sealing have not been assessed and established.Purpose. The purpose of this study was to determine the effectiveness of immediate dentin sealing (IDS) using total-etch or self-etch dentin adhesives on microleakage and microtensile bond strength.Material and methods. Twenty recently extracted molars were selected, and standard MOD inlay preparations were made with the gingival margins located below the cemento-enamel unction. The teeth were assigned to 4 experimental groups (n=5) according to the indirect composite restoration cementation technique used: (1) immediate dentin sealing with Adper Single Bond (TEBI); (2) conventional adhesive cementation technique using Adper Single Bond (TEAI); (3) immediate dentin sealing using Adper Prompt L-Pop (SEBI); or (4) conventional adhesive cementation technique using Adper Prompt L-Pop (SEAI). The restored teeth were thermal cycled 1,000 times between 5 degrees and 55 degrees C and then immersed in 50% ammoniacal silver nitrate. Three specimens per restoration were evaluated for microleakage, according to predefined scores, and submitted to Friedman's test (alpha-.05). The specimens were then sectioned to obtain 0.8 +/- 0.2-mm-thick sticks (with n ranging from 32 to 57 specimens) and submitted to microtensile bond strength (mu TBS) testing. The obtained data were submitted to 2-way ANOVA test (alpha=.05).Results. None of the experimental groups demonstrated complete elimination of marginal microleakage. There were significant differences in microleakage of the tested adhesives (P>.001). IDS microleakage scores were similar to those obtained using the conventional cementation technique (CCT) for both adhesives. The highest mean bond strengths were obtained with TEBI (51.1 MPa), whereas SEAI showed the lowest mean bond strengths (1.7 MPa). IDS resulted in significantly higher bond strengths than CCT (P<.001).Conclusions. Total-etch and self-etch adhesives have a significant effect on IDS. IDS resulted in high bond strengths for both adhesives; however, the microleakage was similar to that obtained with CCT (J Prosthet Dent 2009;102:1-9)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Control of microleakage represents a challenge for posterior composite restorations. The technique for composite placement may reduce microleakage. The null hypothesis of this in vitro study was that centripetal incremental insertion of composite resin would result in less microleakage than that obtained with the oblique incremental technique or bulk technique. Method and Materials: Standardized Class 2 preparations were made in 60 caries-free extracted third molars and randomly assigned to 3 groups ( n = 20): ( 1) oblique incremental insertion technique ( control), ( 2) centripetal incremental insertion technique, and ( 3) bulk insertion. The teeth were restored with a total-etch adhesive and micro-hybrid composite resin. The specimens were isolated with nail varnish except for a 2-mm-wide area around the restoration and then thermocycled ( 1,000 thermal cycles, 5 degrees C/ 55 degrees C; 30-second dwell time). The specimens were immersed in an aqueous solution of 50% silver nitrate for 24 hours, followed by 8 hours of immersion in a photo-developing solution and subsequently evaluated for leakage. The microleakage scores ( 0 to 4) obtained from the occlusal and cervical walls were analyzed with median nonparametric tests ( P <.05). Results: The null hypothesis was rejected. All techniques attained statistically similar dentin microleakage scores ( P =.15). The centripetal insertion technique displayed significantly less microleakage than the oblique technique at the enamel margins ( P =.04). Conclusion: None of the techniques eliminated marginal microleakage in Class 2 preparations. However, in occlusal areas, the centripetal technique performed significantly better than the other techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate the environmental condition of the Barra Bonita Reservoir, we adapted the Index of Biotic Integrity (IBI). We chose 24 sampling sites in which three types of habitats were sampled: the mouths of tributaries, the central reservoir and the lateral reservoir. Fish were caught in two seasons (dry and rainy) using 10 gillnet gangs, with meshes ranging from 3 to 12 cm between opposite knots, and funnel traps. Abiotic and biotic variables were measured. Due to the artificial nature of the reservoir, the term biotic integrity was considered inappropriate and the term RFAI (Reservoir Fish Assemblage Index) was adopted. Twelve metrics from sixteen possibles were selected using the Pearson correlation coefficient. The reference conditions were set up based on the criteria of the best condition observed. For each metric, a score of 1, 3 or 5 was assigned as it strongly departs (1), slightly departs (3) or approaches (5) the reference condition. The index value is the sum of the metrics partial scores and ranges from 12 to 60. To evaluate the importance of the unit of measurement of the metric, the index was calculated in fish number (RFAI(N)) and in weight (RFAI(w)). The correlation between RFAIN and RFAIw was very high (r = 0.90, n = 46) indicating that the unit of measurement does not influence the final result of the index. Most of the sampling sites were classified in the 'reasonable' RFAI category. Only the central sites were classified as 'poor'. To validate the RFAI, another index, the Habitat Quality Index (HQI), was built starting from the physiochemical and habitat variables collected. The correlation of the RFAI with the HQI was highly significant (RFAIN, r = 0.37; RFAI(w), r = 0.47; n = 46), indicating that they respond in the same way to environmental degradation. The HQI metrics which most affect RFAI were depth, surrounding landscape and macrophyte presence/absence. Copyright C) 2007 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this investigation was to examine coupling between visual information and body sway in children and young adults at various distances from a moving room front wall. Sixty children (from 4 to 14 years old) and 10 young adults stood upright inside a moving room that was oscillated at .2 and .5 Hz, at distances of .25, .5, 1, and 1.5 m from a front wall. Visual information induced body sway in all participants in all conditions. Young children swayed more than older participants, whether the moving room was oscillated or not. Coupling between visual information and body sway became stronger and the room movement influence became weaker with age. Up to the age of 10, coupling strength between visual information and body sway and the room movement influence were distance dependent. Postural control development appears to be dependent on how children reweight the contribution of varying sensory cues available in environment in order to control body sway. (C) 2007 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to examine the coupling between visual information and body sway and the adaptation in this coupling of individuals with cerebral palsy (CP). Fifteen children with and 15 without CP. 6-15 years old, were required to stand upright inside of a moving room. All children first performed two trials with no movement of the room and eyes open or closed, then four trials in which the room oscillated at 0.2 or 0.5 Hz (peak velocity of 0.6 cm/s), one trial in which the room oscillated at 0.2 Hz (peak velocity of 3.5 cm/s), and finally two other trials in which the room oscillated again at 0.2 Hz (peak velocity of 0.6 cm/s). Participants with CP coupled body sway to visual information provided by the moving room, comparable to the coupling of participants without CP. However, participants with CP exhibited larger body sway in maintaining upright position and more variable sway when body sway was induced by visual manipulation. They showed adaptive sensory motor coupling, e.g. down-weighting visual influence when a larger stimulus was provided, but not with the same magnitude as typically developing participants. This indicates that participants with CP have less capability of adaptation. (C) 2011 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Realizou-se adaptação cultural do Inventário de Oldenburg para estudantes (OLBI-S) em português e estimou-se sua confiabilidade e validade. O OLBI-S foi preenchido por 958 estudantes universitários brasileiros e 602 portugueses. O modelo fatorial original apresentou ajustamento adequado mas foram removidos dois itens com confiabilidade individual baixa (λ<0,5). A nova estrutura apresentou bom ajustamento a 2/3 da amostra total sendo invariante no 1/3 restante da amostra. Verificou-se baixa consistência interna e validade convergente, confiabilidade compósita aceitável, boa validade discriminante, concorrente e divergente. O OLBI-S não foi invariante nas amostras de Brasil e Portugal. O OLBI-S apresentou limitações e ausência de validade transcultural nas amostras estudadas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Realizou-se adaptação cultural do Inventário de Burnout de Copenhagen para estudantes (CBI-S) em português e estimou-se sua confiabilidade e validade. O CBI-S foi preenchido por 958 estudantes universitários brasileiros e 556 portugueses. O modelo fatorial original apresentou bom ajustamento entretanto, foram removidos dois itens com confiabilidade individual baixa (λ<0,5). A nova estrutura apresentou bom ajustamento a 2/3 da amostra total sendo invariante no 1/3 restante da amostra original. Verficou-se adequada consistência interna e validade convergente, discriminante e concorrente. Os pesos fatoriais do CBI-S não foram invariantes nas amostras de Brasil e Portugal. O CBI-S apresentou adequada confiabilidade e validade entretanto, verificou-se ausência de estabilidade transcultural.