973 resultados para Accuracy rate


Relevância:

20.00% 20.00%

Publicador:

Resumo:

为使星载激光高度计实现高空间分辨力、高距离精度,提出了联合采用调频光纤激光器和相干测距的方法。详细讨论了这种方法的实现方案,并对方案中的激光发射功率、望远镜口径以及脉冲宽度对距离精度及信噪比的影响进行数值模拟。对系统参量进行分析,得到了相关参量的关系和优化的参量。结果表明,当望远镜口径为400 mm时,啁啾调频速率为1 MHz/μs,脉冲时间宽度150~350μs,发射功率10 W左右时,基于相干测距的星载激光高度计可以实现距离精度小于15 cm的技术指标。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

高重复频率热容主振荡功率放大器(MOPA)激光系统的工作过程一般只持续几秒至几十秒,在此过程中系统输出光束的波前畸变是动态变化的。采用环路径向剪切干涉(CRWSI)技术对高重复频率热容MOPA系统波前畸变的变化过程进行检测,并对系统的总体结构进行了设计。搭建了一个简化的实验系统,采用平凹透镜来代替光放大器产生波前畸变,并由此对环路径向剪切干涉仪的测量精度进行了验证。结果表明,实验测量结果与理论计算值之间的峰值误差为7.8%(0.02λ)。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A single-longitudinal-mode (SLM) laser-diode pumped Nd: YAG laser with adjustable pulse width is developed by using the techniques of pre-lasing and changing polarization of birefingent crystal. The Q-switching voltage is triggered by the peak of the pre-lasing pulse to achieve the higher stability of output pulse energy. The output energy of more than 1 mJ is obtained with output energy stability of 3% (rms) at 100 Hz. The pulse-width can be adjusted from 30 ns to 300 ns by changing the Q-switching voltage. The probability of putting out single-longitudinal-mode pulses is almost 100%. The laser can be run over four hours continually without mode hopping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, we report an all-fiber master oscillator power amplifier (MOPA) system, which can provide high repetition rate and nanosecond pulse with diffraction-limit. The system was constructed using a (2 + 1) X 1 multimode combiner. The Q-Switched, LD pumped Nd:YVO4 solid-state laser wets used (is master oscillator. The 976-nm fiber-coupled module is used as pump source. A 10-m long China-made Yb3+-doped D-shape double-clad large-mode-area fiber was used as amplifier fiber. The MOPA produced as much as 20-W average power with nanosecond pulse and near diffraction limited. The pulse duration is maintained at about 15 its during 50-175 kHz. The system employs a simple and compact architecture and is therefore suitable for the use in practical applications such as scientific and military airborne LIDAR and imaging. Based oil this system. the amplification performances of. the all fiber amplifier is investigated. (C) 2008 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple actively Q-switched double-clad fiber laser combining an amplifying cavity is reported by using a dynamic acoustooptic Q-switching as a beam splitter. Sub-100-ns. pulses independence of the repetition rate of acoustooptic modulator are almost changeless with repetition rate varied from 50 kHz to 1.5 MHz. With 4.5-W absorbed power, 9.4-W peak-power pulses at 1.5-MHz repetition rate with 75-ns pulse duration are generated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN]Hyperventilation, which is common both in-hospital and out-of-hospital cardiac arrest, decreases coronary and cerebral perfusion contributing to poorer survival rates in both animals and humans. Current resucitation guidelines recommend continuous monitoring of exhaled carbon dioxide (CO2) during cardiopulmonary resucitation (CPR) and emphasize good quality of CPR, including ventilations at 8-10 min1. Most of commercial monitors/de- brilators incorporate methods to compute the respiratory rate based on capnography since it shows uctuations caused by ventilations. Chest compressions may induce artifacts in this signal making the calculation of the respiratory rate di cult. Nevertheless, the accuracy of these methods during CPR has not been documented yet. The aim of this project is to analyze whether the capnogram is reliable to compute ventilation rate during CPR. A total of 91 episodes, 63 out-of-hospital cardiac arrest episodes ( rst database) and 28 in-hospital cardiac arrest episodes (second database) were used to develop an algorithm to detect ventilations in the capnogram, and the nal aim is to provide an accurate ventilation rate for feedback purposes during CPR. Two graphic user interfaces were developed to make the analysis easier and another two were adapted to carry out this project. The use of this interfaces facilitates the managment of the databases and the calculation of the algorithm accuracy. In the rst database, as gold standard every ventilation was marked by visual inspection of both the impedance, which shows uctuations with every ventilation, and the capnography signal. In the second database, volume of the respiratory ow signal was used as gold standard to mark ventilation instants since it is not a ected by chest compressions. The capnogram was preprocessed to remove high frequency noise, and the rst di erence was computed to de ne the onset of inspiration and expiration. Then, morphological features were extracted and a decission algorithm built based on the extracted features to detect ventilation instants. Finally, ventilation rate was calculated using the detected instants of ventilation. According to the results obtained in this project, the capnogram can be reliably used to give feedback ventilation rate, and therefore, on hyperventilation in a resucitation scenario.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[Es]Las guías de resucitación recomiendan el uso de dispositivos de feedback para mejorar la calidad de las compresiones torácicas. Estos sistemas calculan la profundidad y frecuencia de las compresiones torácicas e informan al rescatador para que, si es necesario, éste corrija su maniobra para ajustarse a los valores recomendados por las guías. La mayoría de estos dispositivos integran la aceleración dos veces para estimar la profundidad de compresión. Sin embargo, cuando la reanimación cardiopulmonar se realiza en vehículos en movimiento, como por ejemplo un tren de larga distancia, los sistemas que utilizan la señal de aceleración pueden verse afectados por las aceleraciones generadas por el propio tren. En este trabajo se estudia la precisión en el cálculo de la profundidad del pecho, a partir de la señal de aceleración, cuando la reanimación cardiopulmonar es realizada en un tren en movimiento. Este análisis permitirá determinar si los sistemas de feedback basados en la aceleración son aptos para ser utilizados en un tren de larga distancia.