975 resultados para 3RD-MOLARS
Resumo:
In the present work, we experimentally study the flow of water over textured hydrophobic surfaces in a micro-channel. Shear stress measurements are done along with direct visualization of trapped air pockets on the hydrophobic surface. The trapped air pockets on such surfaces are known to be responsible for apparent slip at these surfaces and hence in significant drag reduction. In typical circumstances, the apparent slip reduces over time as seen, for example, from our shear stress measurements. This implies that the drag reduction will not be sustained. We have performed extensive visualizations of the trapped air pockets while varying flow parameters like the flow rate and the pressure. We present here direct visualizations that show that under some conditions, the air pockets can grow with time. The variation of the air pocket size with time is found to change qualitatively and quantitatively as the flow rate is varied. These measured changes in the air pocket size with time have a direct bearing on the sustainability of apparent slip in micro-channel flows.
Resumo:
Air can be trapped on the crevices of specially textured hydrophobic surfaces immersed in water. This heterogenous state of wetting in which the water is in contact with both the solid surface and the entrapped air is not stable. Diffusion of air into the surrounding water leads to gradual reduction in the size and numbers of the air bubbles. The sustainability of the entrapped air on such surfaces is important for many underwater applications in which the surfaces have to remain submersed for longer time periods. In this paper we explore the suitability of different classes of surface textures towards the drag reduction application by evaluating the time required for the disappearance of the air bubbles under hydrostatic conditions. Different repetitive textures consisting of holes, pillars and ridges of different sizes have been generated in silicon, aluminium and brass by isotropic etching, wire EDM and chemical etching respectively. These surfaces were rendered hydrophobic with self-assembled layer of fluorooctyl trichlorosilane for silicon and aluminium surfaces and 1-dodecanethiol for brass surfaces. Using total internal reflection the air bubbles are visualized with the help of a microscope and time lapse photography. Irrespective of the texture, both the size and the number of air pockets were found to decrease with time gradually and eventually disappear. In an attempt to reverse the diffusion we explore the possibility of using electrolysis to generate gases at the textured surfaces. The gas bubbles are nucleated everywhere on the surface and as they grow they coalesce with each other and get pinned at the texture edges.
Resumo:
Ceramic/Porcelain insulators are widely used in power transmission lines to provide mechanical support for High voltage conductors in addition to withstand electrical stresses. As a result of lightning, switching or temporary over voltages that could initiate flashover under worst weather conditions, and to operate within interference limits. Given that the useful life in service of the individual insulator elements making up the insulator strings is hard to predict, they must be verified periodically to ensure that adequate line reliability is maintained at all times. Over the years utilities have adopted few methods to detect defective discs in a string, subsequently replacement of the faulty discs are being carried out for smooth operation. But, if the insulator is found to be defective in a string at some location that may not create any changes in the field configuration, there is no need to replace to avoid manpower and cost of replacement. Due to deficiency of electric field data for the existing string configuration, utilities are forced to replace the discs which may not be essentially required. Hence, effort is made in the present work to simulate the potential and electric field along the normal and with faults induced discs in a string up to 765 kV system voltages using Surface Charge Simulation Method (SCSM). A comparison is made between simulated results, experimental and field data and it was found that the computed results are quite acceptable and useful.
Resumo:
In many applications, when communicating with a host, we may or may not be concerned about the privacy of the data but are mainly concerned about the integrity of data being transmitted. This paper presents a simple algorithm based on zero knowledge proof by which the receiver can confirm the integrity of data without the sender having to send the digital signature of the message directly. Also, if the same document is sent across by the same user multiple times, this scheme results in different digital signature each time thus making it a practical one-time signature scheme.
Resumo:
In this paper we present the design of ``e-SURAKSHAK,'' a novel cyber-physical health care management system of Wireless Embedded Internet Devices (WEIDs) that sense vital health parameters. The system is capable of sensing body temperature, heart rate, oxygen saturation level and also allows noninvasive blood pressure (NIBP) measurement. End to end internet connectivity is provided by using 6LoWPAN based wireless network that uses the 802.15.4 radio. A service oriented architecture (SOA) 1] is implemented to extract meaningful information and present it in an easy-to-understand form to the end-user instead of raw data made available by sensors. A central electronic database and health care management software are developed. Vital health parameters are measured and stored periodically in the database. Further, support for real-time measurement of health parameters is provided through a web based GUI. The system has been implemented completely and demonstrated with multiple users and multiple WEIDs.
Resumo:
Since its induction, the selective-identity (sID) model for identity-based cryptosystems and its relationship with various other notions of security has been extensively studied. As a result, it is a general consensus that the sID model is much weaker than the full-identity (ID) model. In this paper, we study the sID model for the particular case of identity-based signatures (IBS). The main focus is on the problem of constructing an ID-secure IBS given an sID-secure IBS without using random oracles-the so-called standard model-and with reasonable security degradation. We accomplish this by devising a generic construction which uses as black-box: i) a chameleon hash function and ii) a weakly-secure public-key signature. We argue that the resulting IBS is ID-secure but with a tightness gap of O(q(s)), where q(s) is the upper bound on the number of signature queries that the adversary is allowed to make. To the best of our knowledge, this is the first attempt at such a generic construction.
Resumo:
The present study experimentally evaluates the performance of control (standard cylinder specimen), damaged (mechanical loading after thermal exposure) and repaired / retrofitted normal plain concrete cylinders using different repair schemes such as on use of FRP wraps, Geo-polymers, etc., to restore the capacity of damaged structural concrete elements. The control-companion specimen in the series provides the reference frame against which both, specimen damage levels were quantified and the benefits of a specimen repaired subsequent to damage were assessed.
Resumo:
Elettra is one of the first 3rd-generation storage rings, recently upgraded to routinely operate in top-up mode at both 2.0 and 2.4 GeV. The facility hosts four dedicated beamlines for crystallography, two open to the users and two under construction, and expected to be ready for public use in 2015. In service since 1994, XRD1 is a general-purpose diffraction beamline. The light source for this wide (4-21 keV) energy range beamline is a permanent magnet wiggler. XRD1 covers experiments ranging from grazing incidence X-ray diffraction to macromolecular crystallography, from industrial applications of powder diffraction to X-ray phasing with long wavelengths. The bending magnet powder diffraction beamline MCX has been open to users since 2009, with a focus on microstructural investigations and studies under non-ambient conditions. A superconducting wiggler delivers a high photon flux to a new fully automated beamline dedicated to macromolecular crystallography and to a branch beamline hosting a high-pressure powder X-ray diffraction station (both currently under construction). Users of the latter experimental station will have access to a specialized sample preparation laboratory, shared with the SISSI infrared beamline. A high throughput crystallization platform equipped with an imaging system for the remote viewing, evaluation and scoring of the macromolecular crystallization experiments has also been established and is open to the user community.
Resumo:
Vehicular Ad-hoc Networks (VANET), is a type of wireless ad-hoc network that aims to provide communication among vehicles. A key characteristic of VANETs is the very high mobility of nodes that result in a frequently changing topology along with the frequent breakage and linkage of the paths among the nodes involved. These characteristics make the Quality of Service (QoS) requirements in VANET a challenging issue. In this paper we characterize the performance available to applications in infrastructureless VANETs in terms of path holding time, path breakage probability and per session throughput as a function of various vehicle densities on road, data traffic rate and number of connections formed among vehicles by making use of table-driven and on-demand routing algorithms. Several QoS constraints in the applications of infrastructureless VANETs are observed in the results obtained.
Resumo:
Wrist pulse signal contains more important information about the health status of a person and pulse signal diagnosis has been employed in oriental medicine since very long time. In this paper we have used signal processing techniques to extract information from wrist pulse signals. For this purpose we have acquired radial artery pulse signals at wrist position noninvasively for different cases of interest. The wrist pulse waveforms have been analyzed using spatial features. Results have been obtained for the case of wrist pulse signals recorded for several subjects before exercise and after exercise. It is shown that the spatial features show statistically significant changes for the two cases and hence they are effective in distinguishing the changes taking place due to exercise. Support vector machine classifier is used to classify between the groups, and a high classification accuracy of 99.71% is achieved. Thus this paper demonstrates the utility of the spatial features in studying wrist pulse signals obtained under various recording conditions. The ability of the model to distinguish changes occurring under two different recording conditions can be potentially used for health care applications.
Resumo:
It is well known that wrist pulse signals contain information about the status of health of a person and hence diagnosis based on pulse signals has assumed great importance since long time. In this paper the efficacy of signal processing techniques in extracting useful information from wrist pulse signals has been demonstrated by using signals recorded under two different experimental conditions viz. before lunch condition and after lunch condition. We have used Pearson's product-moment correlation coefficient, which is an effective measure of phase synchronization, in making a statistical analysis of wrist pulse signals. Contour plots and box plots are used to illustrate various differences. Two-sample t-tests show that the correlations show statistically significant differences between the groups. Results show that the correlation coefficient is effective in distinguishing the changes taking place after having lunch. This paper demonstrates the ability of the wrist pulse signals in detecting changes occurring under two different conditions. The study assumes importance in view of limited literature available on the analysis of wrist pulse signals in the case of food intake and also in view of its potential health care applications.
Resumo:
The present study discusses the photosensitivity of GeS2 chalcogenide glass in response to irradiation with femtosecond pulses at 1047 nm. Bulk GeS2 glasses are prepared by conventional melt quenching technique and the amorphous nature of the glass is confirmed using X-ray diffraction. Ultrafast laser inscription technique is used to fabricate the straight channel waveguides in the glass. Single scan and multi scan waveguides are inscribed in GeS2 glasses of length 0.65 cm using a master oscillator power amplifier Yb doped fiber laser (IMRA mu jewel D400) with different pulse energy and translation speed. Diameters of the inscribed waveguides are measured and its dependence on the inscription parameters such as translation speed and pulse energy is studied. Butt coupling method is used to characterize the loss measurement of the inscribed optical waveguides. The mode field image of the waveguides is captured using CCD camera and compared with the mode field image of a standard SMF-28 fibers.
Resumo:
One-dimensional transient heat flow is interpreted as a procession of `macro-scale translatory motion of indexed isothermal surfaces'. A new analytical model is proposed by introducing velocity of isothermal surface in Fourier heat diffusion equation. The velocity dependent function is extracted by revisiting `the concept of thermal layer of heat conduction in solid' and `exact solution' to estimate thermal diffusivity. The experimental approach involves establishment of 1 D unsteady heat flow inside the sample through Step-temperature excitation. A novel self-reference interferometer is utilized to separate a `unique isothermal surface' in time-varying temperature field. The translatory motion of the said isothermal surface is recorded using digital camera to estimate its velocity. From the knowledge of thermo-optic coefficient, temperature of the said isothermal surface is predicted. The performance of proposed method is evaluated for Quartz sample and compared with literature.
Resumo:
Non-invasive, real-time dynamic monitoring of pressure inside a column with the aid of Fiber Bragg Grating (FBG) sensor is presented in the present work. A bare FBG sensor is adhered on the circumference of a pressure column normal to its axis, which has the ability to acquire the hoop strain induced by the pressure variation inside the column. Pressure induced hoop strain response obtained using FBG sensor is validated against the pressure measurements obtained from conventional pressure gauge. Further, a protrusion setup on the outer surface of the column has been proposed over which a secondary FBG sensor is bonded normal to its axis, in order to increase the gauge length of this FBG sensor. This is carried out in order to validate the variation in sensitivity of the protrusion bonded FBG sensor compared to the bare FBG sensor bonded over the surface. A comparative study is done between the two FBG sensors and a conventional pressure gauge in order to establish the capacity of FBG sensor obtained hoop strain response for pressure monitoring inside the column.
Resumo:
This paper deals with processing the EEG signals obtained from 16 spatially arranged electrodes to measure coupling or synchrony between the frontal, parietal, occipital and temporal lobes of the cerebrum under the eyes open and eyes closed conditions. This synchrony was measured using magnitude squared coherence, Short Time Fourier Transform and wavelet based coherences. We found a pattern in the time-frequency coherence as we moved from the nasion to the inion of the subject's head. The coherence pattern obtained from the wavelet approach was found to be far more capable of picking up peaks in coherence with respect to frequency when compared to the regular Fourier based coherence. We detected high synchrony between frontal polar electrodes that is missing in coherence plots between other electrode pairs. The study has potential applications in healthcare.