993 resultados para 331-C0014A


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Edoxaban, an oral direct factor Xa inhibitor, is in development for thromboprophylaxis, including prevention of stroke and systemic embolism in patients with atrial fibrillation (AF). P-glycoprotein (P-gp), an efflux transporter, modulates absorption and excretion of xenobiotics. Edoxaban is a P-gp substrate, and several cardiovascular (CV) drugs have the potential to inhibit P-gp and increase drug exposure. OBJECTIVE: To assess the potential pharmacokinetic interactions of edoxaban and 6 cardiovascular drugs used in the management of AF and known P-gp substrates/inhibitors. METHODS: Drug-drug interaction studies with edoxaban and CV drugs with known P-gp substrate/inhibitor potential were conducted in healthy subjects. In 4 crossover, 2-period, 2-treatment studies, subjects received edoxaban 60 mg alone and coadministered with quinidine 300 mg (n = 42), verapamil 240 mg (n = 34), atorvastatin 80 mg (n = 32), or dronedarone 400 mg (n = 34). Additionally, edoxaban 60 mg alone and coadministered with amiodarone 400 mg (n = 30) or digoxin 0.25 mg (n = 48) was evaluated in a single-sequence study and 2-cohort study, respectively. RESULTS: Edoxaban exposure measured as area under the curve increased for concomitant administration of edoxaban with quinidine (76.7 %), verapamil (52.7 %), amiodarone (39.8 %), and dronedarone (84.5 %), and exposure measured as 24-h concentrations for quinidine (11.8 %), verapamil (29.1 %), and dronedarone (157.6 %) also increased. Administration of edoxaban with amiodarone decreased the 24-h concentration for edoxaban by 25.7 %. Concomitant administration with digoxin or atorvastatin had minimal effects on edoxaban exposure. CONCLUSION: Coadministration of the P-gp inhibitors quinidine, verapamil, and dronedarone increased edoxaban exposure. Modest/minimal effects were observed for amiodarone, atorvastatin, and digoxin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Semi-Lagrangian finite volume schemes for the numerical approximation of linear advection equations are presented. These schemes are constructed so that the conservation properties are preserved by the numerical approximation. This is achieved using an interpolation procedure based on area-weighting. Numerical results are presented illustrating some of the features of these schemes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A coloration is an exact regular coloration if whenever two vertices are colored the same they have identically colored neighborhoods. For example, if one of the two vertices that are colored the same is connected to three yellow vertices, two white and red, then the other vertex is as well. Exact regular colorations have been discussed informally in the social network literature. However they have been part of the mathematical literature for some time, though in a different format. We explore this concept in terms of social networks and illustrate some important results taken from the mathematical literature. In addition we show how the concept can be extended to ecological and perfect colorations, and discuss how the CATREGE algorithm can be extended to find the maximal exact regular coloration of a graph.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reliability of electronic parts is a major concern for many manufacturers, since early failures in the field can cost an enormous amount to repair - in many cases far more than the original cost of the product. A great deal of effort is expended by manufacturers to determine the failure rates for a process or the fraction of parts that will fail in a period of time. It is widely recognized that the traditional approach to reliability predictions for electronic systems are not suitable for today's products. This approach, based on statistical methods only, does not address the physics governing the failure mechanisms in electronic systems. This paper discusses virtual prototyping technologies which can predict the physics taking place and relate this to appropriate failure mechanisms. Simulation results illustrate the effect of temperature on the assembly process of an electronic package and the lifetime of a flip-chip package.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Review of Making Mathematics with Needlework, edited by Sarah-Marie Belcastro and Carolyn Yackel, published by AK Peters Ltd, 2007 (ISBN 978-1-56881-331-8).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Nicardipine is a member of a family of calcium channel blockers named dihydropiridines that are known to be photolabile and may cause phototoxicity. It is therefore vital to develop analytical method which can study the photodegradation of nicardipine. Method: Forced acid degradation of nicardipine was conducted by heating 12 ml of 1 mg/ml nicardipine with 3 ml of 2.5 M HCl for two hours. A gradient HPLC medthod was developed using Agilent Technologies 1200 series quaternary system. Separation was achieved with a Hichrome (250 x 4.6 mm) 5 μm C18 reversed phase column and mobile phase composition of 70% A(100%v/v water) and 30% B(99%v/v acetonitrile + 1%v/v formic acid) at time zero, composition of A and B was then charged to 60%v/v A;40%v/v B at 10minutes, 50%v/v A; 50%v/v B at 30minutes and 70%v/v A; 30%v/v B at 35minutes. 20μl of 0.8mg/ml of nicardipine degradation was injected at room temperature (25oC). The gradient method was transferred onto a HPLC-ESI-MS system (HP 1050 series - AQUAMAX mass detector) and analysis conducted with an acid degradation concentration of 0.25mg/ml and 20μl injection volume. ESI spectra were acquired in positive ionisation mode with MRM 0-600 m/z. Results: Eleven nicardipine degradation products were detected in the HPLC analysis and the resolution (RS) between the respective degradants where 1.0, 1.2, 6.0, 0.4, 1.7, 3.7, 1.8, 1.0, and 1.7 respectively. Nine degradation products were identified in the ESI spectra with the respective m/z ratio; 171.0, 166.1, 441.2, 423.2, 455.2, 455.2, 331.1, 273.1, and 290.1. The possible molecular formulae for each degradants were ambiguously determined. Conclusion: A sensitive and specific method was developed for the analysis of nicardipine degradants. Method enables detection and quantification of nicardipine degradation products that can be used for the study of the kinetics of nicardipine degradation processes.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador: