991 resultados para 140
Resumo:
High-quality neodymium doped GGG laser crystals have been grown by Czochralski (Cz) method. Results of Nd:GGG thin chip laser operating at 1.064 μm pumped by Ti:sapphire laser operating at 808 nm were reported. The slop efficiency was as high as 20%.
Resumo:
30. Reise des FFS "Walther Herwig" (Island/Neufundland; 17. 7. - 23. 8. 1969)
Resumo:
A cruise aboard the vessel Cassiopeia was held from 14 to 22 November 2000. The objective to map the fishing areas, to study the variation of the catch, income, specific composition and length on wishbone Polysteganus coeruleopunctatus (cachucho) in relation to fishing areas, depth and immersion time of the fish pots. The total capture registered was 4.350,00 Kg for 1600 fish pots and 32 effectuated throws. The highest capture per throw was registered in the interval of depth between the 140 to 180 meters. Regarding the time of immersion, the better captures were obtained in the interval between 25 and 30 hours. The profits during this cross were for fish-trap (2, 71 kg), per throw 135,00 Kg and for immersion hour 6,07 kg. P. coeruleopunctatus (cachucho) was more abundant in number in Quissico, while in Zavora it was abundant in number and also in weight. Likewise, the cachucho was more abundant in number and weight in the captures of the fish pots submerged less than 24 hours, 100-140 meters depth. Cachucho catch under 100 meters depth was quite reduced (less than 1 %). The middle length of the cachucho captured during the cross was 275,7 mm. There were significant differences in the lengths of the cachucho accordingly to depth or fishing area. The smallest individual (fish) was captured by fish pots that were submerged more than 24 hours. The principal recommendations of the study refer to maintenance of the current fishing effort with regard to the number of fish pots, and explore the fishing areas on a rotating basis, to avoid the local effort, currently high.
Resumo:
采用脉冲激光沉积法、选取β-BBO陶瓷作为靶材在掺Sr^2+的α-BBO(001)衬底上进行了生长β-BBO薄膜的实验,生长出表面光滑、无色透明的薄膜。采用X射线粉末衍射(XRD)、高分辨X射线衍射仪(XRC)对薄膜进行分析测试,结果表明,所制备的β-BBO薄膜择优取向为(001)面,薄膜的双晶摇摆曲线半峰宽值FWHM为1000"左方无显示出β-BBO薄膜较好的结晶质量,其紫外吸收边同β-BBO单晶一样也为190nm,但薄膜的透过率略有下降。采用调Q脉冲Nd:YAG激光器观察了β-BBO薄膜的倍频效应。
Resumo:
Computer programs were developed to calculate the parameters commonly used in fisheries statistics: catch per unit effort, catch by species, size distribution, etc. These parameters were computed for collective fishing, purse seine and beach seine; important aspects of the artisanal fisheries in the Ebrié Lagoon.
Resumo:
Laser induced damage threshold (LIDT) of multi-layer dielectric used in pulse compressor gratings (PCG) was investigated. The sample was prepared by e-beam evaporation (EBE). LIDT was detected following ISO standard 11254-1.2. It was found that LIDTs of normal and 51.2 deg. incidence (transverse electric (TE) mode) were 14.14 and 9.31 J/cm2, respectively. A Nomarski microscope was employed to map the damage morphology, and it was found that the damage behavior was pit-concave-plat structure for normal incidence, while it was pit structure for 51.2 deg. incidence with TE mode. The electric field distribution was calculated to illuminate the difference of LIDT between the two incident cases.
Resumo:
We construct an F(R) gravity theory corresponding to the Weyl invariant two scalar field theory. We investigate whether such F (R) gravity can have the antigravity regions where the Weyl curvature invariant does not diverge at the Big Bang and Big Crunch singularities. It is revealed that the divergence cannot be evaded completely but can be much milder than that in the original Weyl invariant two scalar field theory. (C) 2014 The Authors. Published by Elsevier B.V.
Resumo:
Quality of cardiopulmonary resuscitation (CPR) improves through the use of CPR feedback devices. Most feedback devices integrate the acceleration twice to estimate compression depth. However, they use additional sensors or processing techniques to compensate for large displacement drifts caused by integration. This study introduces an accelerometer-based method that avoids integration by using spectral techniques on short duration acceleration intervals. We used a manikin placed on a hard surface, a sternal triaxial accelerometer, and a photoelectric distance sensor (gold standard). Twenty volunteers provided 60 s of continuous compressions to test various rates (80-140 min(-1)), depths (3-5 cm), and accelerometer misalignment conditions. A total of 320 records with 35312 compressions were analysed. The global root-mean-square errors in rate and depth were below 1.5 min(-1) and 2 mm for analysis intervals between 2 and 5 s. For 3 s analysis intervals the 95% levels of agreement between the method and the gold standard were within -1.64-1.67 min(-1) and -1.69-1.72 mm, respectively. Accurate feedback on chest compression rate and depth is feasible applying spectral techniques to the acceleration. The method avoids additional techniques to compensate for the integration displacement drift, improving accuracy, and simplifying current accelerometer-based devices.