987 resultados para 0.9 per mil were added


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A total of 2538 quarter milk samples from 638 lactating dairy cows from 47 farms in the canton of Bern, Switzerland, were investigated for streptococci. A novel, simple and inexpensive laboratory method was used for the differentiation of Streptococcus species, and a risk factor analysis was carried out. The prevalence in the quarter milk samples was 0.2 per cent for Streptococcus agalactiae, 1.3 per cent for Streptococcus uberis, 1.3 per cent for Streptococcus dysgalactiae, 0.1 per cent for Enterococcus species and 2.9 per cent for minor Streptococcus species (designated Streptococcus-Lactococcus-Enterococcus [SLE] group). Based on the somatic cell count (SCC), S uberis and S dysgalactiae were classified as 'major' pathogens and the bacteria in the SLE group as 'minor' pathogens. For S uberis, S dysgalactiae and bacteria in the SLE group, the most significant risk factor was an intramammary infection (IMI) of a neighbouring quarter by the same pathogen. Other significant risk factors for S uberis infection were a positive California Mastitis Test (CMT) result and a SCC of more than 100,000 cells/ml. Significant risk factors for IMI with S dysgalactiae were a positive CMT result, teat injury and palpable abnormalities in the udder. Infection with bacteria in the SLE group was significantly associated with a SCC of more than 100,000 cells/ml, a lactation number of more than 2, the right rear quarter (as the location of infection) and a positive CMT result.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Although lung clearance index (LCI) is a sensitive indicator of mild cystic fibrosis (CF) lung disease, it is rarely measured due to lengthy protocols and the commercial unavailability of multiple-breath washout (MBW) setups and tracer gases. We used a newly validated, commercially available nitrogen (N(2) ) MBW setup to assess success rate, duration, and variability of LCI within a 20 min timeframe, during clinical routine. We also evaluated the relationship between LCI and other clinical markers of CF lung disease. METHODS: One hundred thirty six children (83 with CF) between 4 and 16 years were studied in a pediatric CF outpatient setting. One hundred eighteen out of 136 children were naïve to MBW. Within 20 min, each child was trained, N(2) MBW was performed, and LCI was analyzed. We assessed intra- and between-test reproducibility in a subgroup of children. RESULTS: At least one LCI was feasible in 123 (90%) children, with a mean (range) of 3.3 (1.2-6.4) min per test. Two or more measurements were feasible in 56 (41%) children. Comparing LCI in CF versus controls, LCI mean (SD) was 12.0 (3.9) versus 6.1 (0.9), and the intra- and inter-test coefficient of repeatability was 1.00 versus 0.81 and 0.96 versus 0.62, respectively. LCI was correlated with spirometry, blood gases, and Pseudomonas aeruginosa infection. CONCLUSIONS: Using available N(2) MBW equipment, LCI measurements are practical and fast in children. LCI is correlated with markers of CF lung disease. Longer timeframes would be required for triplicate N(2) MBW tests in inexperienced children. Pediatr Pulmonol. © 2012 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the trauma surgeons' daily challenges is the balancing act between negative laparotomy and missed abdominal injury. We opted to characterize the indications that prompted a negative trauma exploratory laparotomy and the rate of missed abdominal injuries in an effort to optimize patient selection for laparotomy. At the Los Angeles County + University of Southern California Medical Center, negative laparotomies and missed injuries are consecutively captured and reviewed at the weekly mortality + morbidity (MM) conferences. All written reports of the MM meetings from January 2003 to December 2008 were reviewed to identify all patients who underwent a negative laparotomy or a laparotomy as a result of an initially missed abdominal injury. Over the 6-year study period, a total of 1871 laparotomies were performed, of which 73 (3.9%) were negative. The rate of missed injuries requiring subsequent laparotomy was 1.3 per cent (25 of 1871). The negative laparotomy rate and the rate of missed injuries did not vary significantly during the study period (2.8 to 4.7%, P = 0.875, and 0.7 to 2.9%, P = 0.689). Penetrating mechanisms accounted for the majority of negative laparotomies (58.9%). The primary indication for negative laparotomy was peritonitis (54.8%) followed by hypotension (28.8%) and suspicious computed tomographic scan findings (27.4%). The complication rate after negative laparotomy was 14.5 per cent, and of these, 10.1 per cent were directly related to the procedure. A low but steady rate of negative laparotomies and missed abdominal injuries after trauma remains. Negative laparotomies and missed abdominal injuries when they occur are still associated with significant complication rates and a prolonged length of stay.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Stopping antiretroviral therapy in patients with HIV-1 infection can reduce costs and side-effects, but carries the risk of increased immune suppression and emergence of resistance. METHODS: 430 patients with CD4-positive T-lymphocyte (CD4) counts greater than 350 cells per muL, and viral load less than 50 copies per mL were randomised to continued therapy (n=146) or scheduled treatment interruptions (n=284). Median time on randomised treatment was 21.9 months (range 16.4-25.3). Primary endpoints were proportion of patients with viral load less than 50 copies per mL at the end of the trial, and amount of drugs used. Analysis was intention-to-treat. This study is registered at ClinicalTrials.gov with the identifier NCT00113126. FINDINGS: Drug savings in the scheduled treatment interruption group, compared with continuous treatment, amounted to 61.5%. 257 of 284 (90.5%) patients in the scheduled treatment interruption group reached a viral load less than 50 copies per mL, compared with 134 of 146 (91.8%) in the continued treatment group (difference 1.3%, 95% CI-4.3 to 6.9, p=0.90). No AIDS-defining events occurred. Diarrhoea and neuropathy were more frequent with continuous treatment; candidiasis was more frequent with scheduled treatment interruption. Ten patients (2.3%) had resistance mutations, with no significant differences between groups. INTERPRETATION: Drug savings with scheduled treatment interruption were substantial, and no evidence of increased treatment resistance emerged. Treatment-related adverse events were more frequent with continuous treatment, but low CD4 counts and minor manifestations of HIV infection were more frequent with scheduled treatment interruption.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Individual adaptation of processed patient's blood volume (PBV) should reduce number and/or duration of autologous peripheral blood progenitor cell (PBPC) collections. STUDY DESIGN AND METHODS: The durations of leukapheresis procedures were adapted by means of an interim analysis of harvested CD34+ cells to obtain the intended yield of CD34+ within as few and/or short as possible leukapheresis procedures. Absolute efficiency (AE; CD34+/kg body weight) and relative efficiency (RE; total CD34+ yield of single apheresis/total number of preapheresis CD34+) were calculated, assuming an intraapheresis recruitment if RE was greater than 1, and a yield prediction models for adults was generated. RESULTS: A total of 196 adults required a total of 266 PBPC collections. The median AE was 7.99 x 10(6), and the median RE was 1.76. The prediction model for AE showed a satisfactory predictive value for preapheresis CD34+ only. The prediction model for RE also showed a low predictive value (R2 = 0.36). Twenty-eight children underwent 44 PBPC collections. The median AE was 12.13 x 10(6), and the median RE was 1.62. Major complications comprised bleeding episodes related to central venous catheters (n = 4) and severe thrombocytopenia of less than 10 x 10(9) per L (n = 16). CONCLUSION: A CD34+ interim analysis is a suitable tool for individual adaptation of the duration of leukapheresis. During leukapheresis, a substantial recruitment of CD34+ was observed, resulting in a RE of greater than 1 in more than 75 percent of patients. The upper limit of processed PBV showing an intraapheresis CD34+ recruitment is higher than in a standard large-volume leukapheresis. Therefore, a reduction of individually needed PBPC collections by means of a further escalation of the processed PBV seems possible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The Baxter Amicus Version 2.51 (A) and the Gambro BCT Trima Accel Version 5.0 (T) cell separators may produce multiple platelet (PLT) concentrates within a single donation. STUDY DESIGN AND METHODS: The single-needle multiple plateletpheresis procedures of the two devices were compared in a prospective, randomized, paired crossover study in 60 donors. The 120 donations were compared for donor comfort, collection efficiency, residual white blood cell (WBC) count, and (in selected patients) corrected count increment (CCI). RESULTS: The mean PLT yield and the resultant mean number of units per donation were significantly lower for A (6.06 x 10(11) vs. 7.48 x 10(11) and 2.57 vs. 3.19, respectively, both p < 0.001), in spite of a longer apheresis duration (89 min vs. 79 min; p < 0.001). This resulted in a higher collection rate of T (5.68 x 10(11) PLTs/hr vs. 4.10 x 10(11) PLTs/hr, p < 0.001). Residual WBC count of every unit was fewer than 5 x 10(6), but significantly fewer A-PLT donations contained more than 10(5) WBCs per unit (1 vs. 9, p = 0.008). Although the ACD-A consumption was slightly higher for A (489 mL vs. 469 mL, p = 0.04), a trend to a higher frequency of side effects was found for T (42.4% vs. 23.7%, p = 0.06). The 1-hour CCIs of 33 transfused A-PLT units were comparable with those of 43 T-PLT units (11.8 vs. 13.9, p = 0.480). CONCLUSIONS: Both cell separators showed safe collections of up to 4 PLT units per donation with adequate CCI. T produced a higher PLT yield despite shorter apheresis duration, but with slightly higher residual WBC counts and a trend to a higher side-effect frequency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Mitochondrial respiration is impaired during endotoxemia. While catecholamines are frequently used in sepsis, their effects on mitochondrial function are controversial. We assessed effects of dobutamine and dopamine endotoxin on isolated muscle mitochondria. MATERIALS AND METHODS: Sternocleidomastoid muscle mitochondria were isolated from six anesthetized pigs. Each sample was divided into six different groups. Three groups were incubated with endotoxin, three with vehicle. After 1 h, dopamine and dobutamine at final concentrations of 100 microM were added to the vehicle and endotoxin groups. After 2 h, state 3 and 4 respiration rates were determined for all mitochondrial complexes. Oxygen consumption was determined with a Clark-type electrode. RESULTS: Endotoxin increased glutamate-dependent state 4 respiration from 9.3 +/- 3.6 to 31.9 +/- 9.1 (P = 0.001) without affecting state 3 respiration. This reduced the efficiency of mitochondrial respiration (RCR; state 3/state 4, 9.9 +/- 1.9 versus 3.6 +/- 0.6; P < 0.001). The other complexes were unaffected. Catecholamine partially restored the endotoxin-induced increase in complex I state 4 respiration rate (31.9 +/- 9.1 versus 17.1 +/- 6.4 and 20.1 +/- 12.2) after dopamine and dobutamine, respectively (P = 0.007), and enhanced the ADP:O ratio (P = 0.033). CONCLUSIONS: Dopamine and dobutamine enhanced the efficiency of mitochondrial respiration after short-term endotoxin exposure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The effectiveness of various appendiceal stump closure methods has not been evaluated systematically. The aim of this study was to compare the morbidity of stump closure by stapling or use of endoloops. METHODS: A non-concurrent cohort study of prospectively acquired data was performed. The primary outcome variable was the rate of intra-abdominal surgical-site infection. Secondary outcome measures were complications, duration of intervention, hospital stay, rate of readmission to hospital and the difference in direct costs of the operation. RESULTS: Staples were used in 60.5 per cent and endoloops in 39.5 per cent of 6486 patients operated on for suspected appendicitis between January 1995 and December 2003. Among 4489 patients with acute appendicitis the rate of intra-abdominal surgical-site infection was 0.7 per cent in the stapler group and 1.7 per cent in the endoloop group (P = 0.004). The rate of readmission to hospital was 0.9 and 2.1 per cent respectively (P = 0.001). CONCLUSION: Application of a stapler for transection and closure of the appendiceal stump in patients with acute appendicitis lowered the risk of postoperative intra-abdominal surgical-site infection and the need for readmission to hospital.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to acquire information about the effect of an antibacterial and biodegradable poly-L-lactide (PLLA) coated titanium plate osteosynthesis on local infection resistance. For our in vitro and in vivo experiments, we used six-hole AO DC minifragment titanium plates. The implants were coated with biodegradable, semiamorphous PLLA (coating about 30 microm thick). This acted as a carrier substance to which either antibiotics or antiseptics were added. The antibiotic we applied was a combination of Rifampicin and fusidic acid; the antiseptic was a combination of Octenidin and Irgasan. This produced the following groups: Group I: six-hole AO DC minifragment titanium plate without PLLA; Group II: six-hole AO DC minifragment titanium plate with PLLA without antibiotics/antiseptics; Group III: six-hole AO DC minifragment titanium plate with PLLA + 3% Rifampicin and 7% fusidic acid; Group IV: six-hole AO DC minifragment titanium plate with PLLA + 2% Octenidin and 8% Irgasan. In vitro, we investigated the degradation and the release of the PLLA coating over a period of 6 weeks, the bactericidal efficacy of antibiotics/antiseptics after their release from the coating and the bacterial adhesion of Staphylococcus aureus to the implants. In vivo, we compared the infection rates in white New Zealand rabbits after titanium plate osteosynthesis of the tibia with or without antibacterial coating after local percutaneous bacterial inoculations at different concentrations (2 x 10(5)-2 x 10(8)): The plate, the contaminated soft tissues and the underlying bone were removed under sterile conditions after 28 days and quantitatively evaluated for bacterial growth. A stepwise experimental design with an "up-and-down" dosage technique was used to adjust the bacterial challenge in the area of the ID50 (50% infection dose). Statistical evaluation of the differences between the infection rates of both groups was performed using the two-sided Fisher exact test (p < 0.05). Over a period of 6 weeks, a continuous degradation of the PLLA coating of 13%, on average, was seen in vitro in 0.9% NaCl solution. The elution tests on titanium implants with antibiotic or antiseptic coatings produced average release values of 60% of the incorporated antibiotic or 62% of the incorporated antiseptic within the first 60 min. This was followed by a much slower, but nevertheless continuous, release of the incorporated antibiotic and antiseptic over days and weeks. At the end of the test period of 42 days, 20% of the incorporated antibiotic and 15% of the incorporated antiseptic had not yet been released from the coating. The antibacterial effect of the antibiotic/antiseptic is not lost by integrating it into the PLLA coating. The overall infection rate in the in vivo investigation was 50%. For Groups I and II the infection rate was both 83% (10 of 12 animals). In Groups III and IV with antibacterial coating, the infection rate was both 17% (2 of 12 animals). The ID50 in the antibacterial coated Groups III and IV was recorded as 1 x 10(8) CFU, whereas the ID50 values in the Groups I and II without antibacterial coating were a hundred times lower at 1 x 10(6) CFU, respectively. The difference between the groups with and without antibacterial coating was statistically significant (p = 0.033). Using an antibacterial biodegradable PLLA coating on titanium plates, a significant reduction of infection rate in an in vitro and in vivo investigation could be demonstrated. For the first time, to our knowledge, we were able to show, under standardized and reproducible conditions, that an antiseptic coating leads to the same reduction in infection rate as an antibiotic coating. Taking the problem of antibiotic-induced bacterial resistance into consideration, we thus regard the antiseptic coating, which shows the same level of effectiveness, as advantageous.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RATIONALE: Nighttime agitation occurs frequently in patients with dementia and represents the number one burden on caregivers today. Current treatment options are few and limited due to substantial side effects. OBJECTIVES: The aim of the study was to measure the effect of the cannabinoid dronabinol on nocturnal motor activity. METHODS: In an open-label pilot study, six consecutive patients in the late stages of dementia and suffering from circadian and behavioral disturbances-five patients with Alzheimer's disease and one patient with vascular dementia-were treated with 2.5 mg dronabinol daily for 2 weeks. Motor activity was measured objectively using actigraphy. RESULTS: Compared to baseline, dronabinol led to a reduction in nocturnal motor activity (P=0.028). These findings were corroborated by improvements in Neuropsychiatric Inventory total score (P=0.027) as well as in subscores for agitation, aberrant motor, and nighttime behaviors (P<0.05). No side effects were observed. CONCLUSIONS: The study suggests that dronabinol was able to reduce nocturnal motor activity and agitation in severely demented patients. Thus, it appears that dronabinol may be a safe new treatment option for behavioral and circadian disturbances in dementia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY DESIGN: Open label study to determine drug dose for a randomized double-blind placebo-controlled parallel study. OBJECTIVES: To assess the efficacy and side effects of oral Delta(9)-tetrahydrocannabinol (THC) and rectal THC-hemisuccinate (THC-HS) in SCI patients. SETTING: REHAB Basel, Switzerland. METHOD: Twenty-five patients with SCI were included in this three-phase study with individual dose adjustment, each consisting of 6 weeks. Twenty-two participants received oral THC open label starting with a single dose of 10 mg (Phase 1, completed by 15 patients). Eight subjects received rectal THC-HS (Phase 2, completed by seven patients). In Phase 3, six patients were treated with oral THC and seven with placebo. Major outcome parameters were the spasticity sum score (SSS) using the Modified Ashworth Scale (MAS) and self-ratings of spasticity. RESULTS: Mean daily doses were 31 mg with THC and 43 mg with THC-HS. Mean SSS for THC decreased significantly from 16.72 (+/-7.60) at baseline to 8.92 (+/-7.14) on day 43. Similar improvement was seen with THC-HS. We observed a significant improvement of SSS with active drug (P=0.001) in the seven subjects who received oral THC in Phase 1 and placebo in Phase 3. Major reasons for drop out were increase of pain and psychological side effects. CONCLUSION: THC is an effective and safe drug in the treatment of spasticity. At least 15-20 mg per day were needed to achieve a therapeutic effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Stent thrombosis is a safety concern associated with use of drug-eluting stents. Little is known about occurrence of stent thrombosis more than 1 year after implantation of such stents. METHODS: Between April, 2002, and Dec, 2005, 8146 patients underwent percutaneous coronary intervention with sirolimus-eluting stents (SES; n=3823) or paclitaxel-eluting stents (PES; n=4323) at two academic hospitals. We assessed data from this group to ascertain the incidence, time course, and correlates of stent thrombosis, and the differences between early (0-30 days) and late (>30 days) stent thrombosis and between SES and PES. FINDINGS: Angiographically documented stent thrombosis occurred in 152 patients (incidence density 1.3 per 100 person-years; cumulative incidence at 3 years 2.9%). Early stent thrombosis was noted in 91 (60%) patients, and late stent thrombosis in 61 (40%) patients. Late stent thrombosis occurred steadily at a constant rate of 0.6% per year up to 3 years after stent implantation. Incidence of early stent thrombosis was similar for SES (1.1%) and PES (1.3%), but late stent thrombosis was more frequent with PES (1.8%) than with SES (1.4%; p=0.031). At the time of stent thrombosis, dual antiplatelet therapy was being taken by 87% (early) and 23% (late) of patients (p<0.0001). Independent predictors of overall stent thrombosis were acute coronary syndrome at presentation (hazard ratio 2.28, 95% CI 1.29-4.03) and diabetes (2.03, 1.07-3.83). INTERPRETATION: Late stent thrombosis was encountered steadily with no evidence of diminution up to 3 years of follow-up. Early and late stent thrombosis were observed with SES and with PES. Acute coronary syndrome at presentation and diabetes were independent predictors of stent thrombosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Antiretroviral therapy (ART) decreases morbidity and mortality in HIV-infected patients but is associated with considerable adverse events (AEs). METHODS: We examined the effect of AEs to ART on mortality, treatment modifications and drop-out in the Swiss HIV Cohort Study. A cross-sectional evaluation of prevalence of 13 clinical and 11 laboratory parameters was performed in 1999 in 1,078 patients on ART. AEs were defined as abnormalities probably or certainly related to ART. A score including the number and severity of AEs was defined. The subsequent progression to death, drop-out and treatment modification due to intolerance were evaluated according to the baseline AE score and characteristics of individual AEs. RESULTS: Of the 1,078 patients, laboratory AEs were reported in 23% and clinical AEs in 45%. During a median follow up of 5.9 years, laboratory AEs were associated with higher mortality with an adjusted hazard ratio (HR) of 1.3 (95% confidence interval [CI] 1.2-1.5; P < 0.001) per score point. For clinical AEs no significant association with increased mortality was found. In contrast, an increasing score for clinical AEs (HR 1.11,95% CI 1.04-1.18; P = 0.002), but not for laboratory AEs (HR 1.07, 95% CI 0.97-1.17; P = 0.17), was associated with antiretroviral treatment modification. AEs were not associated with a higher drop-out rate. CONCLUSIONS: The burden of laboratory AEs to antiretroviral drugs is associated with a higher mortality. Physicians seem to change treatments to relieve clinical symptoms, while accepting laboratory AEs. Minimizing laboratory drug toxicity seems warranted and its influence on survival should be further evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to evaluate in a phantom study the effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation. MATERIALS AND METHODS: One or two 4-cm-thick circumferential layers of fat-equivalent material were added to the abdomen of an anthropomorphic phantom to simulate patients of three sizes: small (cross-sectional dimensions, 18 x 22 cm), average size (26 x 30 cm), and oversize (34 x 38 cm). Imaging was performed with a 64-MDCT scanner with combined z-axis and xy-axis tube current modulation according to two protocols: protocol A had a noise index of 12.5 H, and protocol B, 15.0 H. Radiation doses to three abdominal organs and the skin were assessed. Image noise also was measured. RESULTS: Despite increasing patient size, the image noise measured was similar for protocol A (range, 11.7-12.2 H) and protocol B (range, 13.9-14.8 H) (p > 0.05). With the two protocols, in comparison with the dose of the small patient, the abdominal organ doses of the average-sized patient and the oversized patient increased 161.5-190.6%and 426.9-528.1%, respectively (p < 0.001). The skin dose increased as much as 268.6% for the average-sized patient and 816.3% for the oversized patient compared with the small patient (p < 0.001). CONCLUSION: Oversized patients undergoing abdominal MDCT with tube current modulation receive significantly higher doses than do small patients. The noise index needs to be adjusted to the body habitus to ensure dose efficiency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Stent thrombosis may occur late after drug-eluting stent (DES) implantation, and its cause remains unknown. The present study investigated differences of the stented segment between patients with and without very late stent thrombosis with the use of intravascular ultrasound. METHODS AND RESULTS: Since January 2004, patients presenting with very late stent thrombosis (> 1 year) after DES implantation underwent intravascular ultrasound. Findings in patients with very late stent thrombosis were compared with intravascular ultrasound routinely obtained 8 months after DES implantation in 144 control patients, who did not experience stent thrombosis for > or = 2 years. Very late stent thrombosis was encountered in 13 patients at a mean of 630+/-166 days after DES implantation. Compared with DES controls, patients with very late stent thrombosis had longer lesions (23.9+/-16.0 versus 13.3+/-7.9 mm; P<0.001) and stents (34.6+/-22.4 versus 18.6+/-9.5 mm; P<0.001), more stents per lesion (1.6+/-0.9 versus 1.1+/-0.4; P<0.001), and stent overlap (39% versus 8%; P<0.001). Vessel cross-sectional area was similar for the reference segment (cross-sectional area of the external elastic membrane: 18.9+/-6.9 versus 20.4+/-7.2 mm2; P=0.46) but significantly larger for the in-stent segment (28.6+/-11.9 versus 20.1+/-6.7 mm2; P=0.03) in very late stent thrombosis patients compared with DES controls. Incomplete stent apposition was more frequent (77% versus 12%; P<0.001) and maximal incomplete stent apposition area was larger (8.3+/-7.5 versus 4.0+/-3.8 mm2; P=0.03) in patients with very late stent thrombosis compared with controls. CONCLUSIONS: Incomplete stent apposition is highly prevalent in patients with very late stent thrombosis after DES implantation, suggesting a role in the pathogenesis of this adverse event.