871 resultados para ultrassonografia ocular


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE:

The purpose of this study was to report on Tsukamurella as a mimic of atypical mycobacterial infection.

METHODS:

We report a patient who had received repeated corneal grafts with culture-proven Tsukamurella keratitis.

RESULTS:

A slow-progressing corneal abscess that initially developed adjacent to a corneal stitch responded poorly to empiric antibiotic treatment. A preliminary culture report revealed fast-growing mycobacterial species. Treatment adjustments successfully controlled the disease. A final diagnosis of Tsukamurella was subsequently made on the basis of cultures.

CONCLUSIONS:

Tsukamurella exhibits laboratory similarities to mycobacteria and should be considered in the differential of atypical infection of the ocular surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess the use of eye care and its predictors among diabetic patients in China. DESIGN: Cross-sectional, clinic-based study. PARTICIPANTS: Diabetic patients 18 years of age or older were recruited consecutively from an urban tertiary and community hospitals and from a rural clinic in Guangdong, China. METHODS: Information obtained by questionnaire and chart review included: demographic and socioeconomic status, knowledge about diabetic retinopathy (DR), and ocular and medical history. MAIN OUTCOME MEASURES: Self-reported or chart history of an eye examination ever or within the preceding 12 months. RESULTS: The participation rate among 889 eligible subjects was 92.7%. Among 824 participants (mean age, 62.6+/-12.9 years; 58.8% female), 550 (66.7%) had not been examined in the last year as recommended by the American Academy of Ophthalmology, and 356 (43.2%) had never been examined. For the rural hospital, these figures were 81.1% and 68.7%, respectively. In regression analyses, factors associated with having an eye examination in the last year were: attendance at urban hospitals (odds ratio [OR], 3.46 [P<0.001] and 1.76 [P = 0.021] for the tertiary and community hospitals, respectively, compared with the rural clinic), higher DR knowledge score (OR, 1.24; P = 0.001), greater concern about vision loss (OR, 1.22; P = 0.007), and recommendation of regular eye examinations by the provider (OR, 2.36; P = 0.011). Predictors of ever having an eye examination were similar. Monthly income and health insurance status were not predictive of being examined. CONCLUSIONS: These results suggest that the low proportion of diabetic receiving recommended annual eye examinations in China may be improved through patient and physician education. Copyright © 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Low corneal hysteresis is associated with longer axial length in Chinese secondary school children. The authors sought to explore this association in primary school children. METHODS: LogMAR presenting visual acuity, cycloplegic refractive error, ocular biometry, central corneal thickness (CCT), and corneal hysteresis (CH) was assessed for children in grades 1 to 3 at an academically competitive urban school in Shantou, China. RESULTS: Among 872 eligible children (mean age, 8.6 ± 2.1 years), 651 (74.7%) completed the examination. Among 1299 examined eyes, 111 (8.5%) had uncorrected vision ≤6/12. Mean spherical equivalent refractive error for all eyes was +0.26 ± 1.41 D, and axial length (AL) was 22.7 ± 0.90 mm. CH for the lowest (mean AL, 21.7 ± 0.39 mm), two middle (mean AL, 22.4 ± 0.15 and 22.9 ± 0.15 mm), and highest quartiles (mean AL, 23.7 ± 0.74 mm) of AL were 10.6 ± 2.1 mm Hg, 10.4 ± 2.1 mm Hg, 10.3 ± 2.3 mm Hg, and 10.2 ± 2.3 mm Hg respectively (age- and gender-adjusted Pearson's correlation coefficient r = -0.052; P = 0.001). In generalized estimating equation models adjusting for age, gender, and CCT, lower CH was significantly associated with longer AL (P < 0.001) and more myopic refractive error (P = 0.001). CONCLUSIONS: CH measurement is practical in young children because this is when myopia undergoes its most rapid progression. Prospective follow-up of this cohort at high risk for myopia is under way to determine whether low CH is predictive, or a consequence, of long AL.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess the sensitivity and specificity of models predicting myopia onset among ethnically Chinese children. METHODS: Visual acuity, height, weight, biometry (A-scan, keratometry), and refractive error were assessed at baseline and 3 years later using the same equipment and protocol in primary schools in Xiamen (China) and Singapore. A regression model predicting the onset of myopia < -0.75 diopters (D) after 3 years in either eye among Xiamen children was validated with Singapore data. RESULTS: Baseline data were collected from 236 Xiamen children (mean age, 7.82 ± 0.63 years) and from 1979 predominantly Chinese children in Singapore (7.83 ± 0.84 years). Singapore children were significantly taller and heavier, and had more myopia (31.4% vs. 6.36% < -0.75 D in either eye, P < 0.001) and longer mean axial length. Three-year follow-up was available for 80.0% of Xiamen children and 83.1% in Singapore. For Xiamen, the area under the receiver-operator curve (AUC) in a model including ocular biometry, height, weight, and presenting visual acuity was 0.974 (95% confidence interval [CI], 0.945-0.997). In Singapore, the same model achieved sensitivity, specificity, and positive predictive value of 0.844, 0.650, and 0.669, with an AUC of 0.815 (95% CI, 0.791-0.839). CONCLUSIONS: Accuracy in predicting myopia onset based on simple measurements may be sufficient to make targeted early intervention practical in settings such as Singapore with high myopia prevalence. Models based on cohorts with a greater prevalence of high myopia than that in Xiamen could be used to assess accuracy of models predicting more severe forms of myopia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To describe the distribution of central corneal thickness (CCT), intraocular pressure (IOP), and their determinants and association with glaucoma in Chinese adults.DESIGN: Population-based cross-sectional study.METHODS: Chinese adults aged 50 years and older were identified using cluster random sampling in Liwan District, Guangzhou. CCT (both optical [OCCT] and ultrasound [UCCT]), intraocular pressure (by Tonopen, IOP), refractive error (by autorefractor, RE), radius of corneal curvature (RCC), axial length (AL), and body mass index (BMI) were measured, and history of hypertension and diabetes (DM) was collected by questionnaire. Right eye data were analyzed.RESULTS: The mean values of OCCT, UCCT, and IOP were 512 ± 29.0 μm, 542 ± 31.4 μm, and 15.2 ± 3.1 mm Hg, respectively. In multiple regression models, CCT declined with age (P < .001) and increased with greater RCC (P < .001) and DM (P = .037). IOP was positively associated with greater CCT (P < .001), BMI (P < .001), and hypertension (P < .001). All 25 persons with open-angle glaucoma had IOP <21 mm Hg. CCT did not differ significantly between persons with and without open- or closed-angle glaucoma. Among 65 persons with ocular hypertension (IOP >97.5th percentile), CCT (555 ± 29 μm) was significantly (P = .01) higher than for normal persons.CONCLUSIONS: The distributions of CCT and IOP in this study are similar to that for other Chinese populations, though IOP was lower than for European populations, possibly due to lower BMI and blood pressure. Glaucoma with IOP <21 mm Hg is common in this population. We found no association between glaucoma and CCT, though power (0.3) for this analysis was low.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES:

To assess the use of eye care and its predictors among diabetic patients in Indonesia.

METHODS:

Diabetic patients aged 18 years and older were recruited consecutively from a university clinic and 2 community clinics in Jakarta, Indonesia. Information obtained by questionnaire and record review included demographic and socioeconomic status, knowledge about diabetic retinopathy, and ocular and medical history. The main outcome was self-reported or record history of an eye examination by an eye care professional with dilation of the pupil within the preceding year.

RESULTS:

Among 196 participants (mean [SD] age, 58.4 [9.4] years; 61.5% female), 166 (84.7%) had not undergone ocular examination in the last year, including 100 of 119 patients (84.0%) at the university clinic. Fewer than half (82 of 166 [49.4%]) of all patients reported being told of the need for eye examinations by their physician. In regression analyses, factors associated with having an eye examination were higher diabetic retinopathy knowledge score (odds ratio = 1.52; P = .01) and years since being diagnosed as having diabetes (odds ratio = 1.71 for third vs first tertile; P = .02). Education, income, health insurance status, and diagnosis of diabetic retinopathy were not predictive of examination. The most common reasons given by subjects for not having had eye examinations concerned lack of knowledge about the need for care (97 of 160 subjects [60.6%]), while financial barriers were cited by only 22 of 160 subjects (13.8%).

CONCLUSION:

The low proportion of diabetic subjects receiving recommended annual eye examinations in Indonesia might be improved through patient and physician education.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess determinants of patients' willingness to pay (WTP) for potential components of a multi-tiered cataract surgical package offered by a non-governmental organization (NGO) in rural China. DESIGN: Cross-sectional study. METHODS: Demographic and clinical data were collected from 505 patients presenting for cataract screening or surgery in Yangjiang, China. Willingness to pay for potential enhancements to the current surgery package was assessed using a bidding format with random payment cards. RESULTS: Among 426 subjects (84.4%) completing interviews, the mean age was 73.9 ± 7.3 years, 67.6% were women and 73% (n = 310) would pay for at least one offering, with 33-38% WTP for each item. Among those who would pay, the mean WTP for food was US$1.68 ± 0.13, transportation US$3.24 ± 0.25, senior surgeon US$50.0 ± 3.36 and US$89.4 ± 4.19 for an imported intra-ocular lens (IOL). The estimated total recovery from these enhancements under various assumptions would be US$20-50 (compared to the current programme price of US$65). In multivariate models, WTP for the senior surgeon increased with knowledge of a person previously operated for cataract (OR = 2.13, 95% CI 1.42-3.18, p < 0.001). Willingness to pay for the imported IOL increased with knowledge of a previously operated person (OR = 1.85, 95% CI 1.24-2.75, p < 0.01) and decreased with age >75 years (OR = 0.61, 0.40-0.93, p < 0.05). CONCLUSIONS: Opportunities exist to increase cataract programme revenues through multi-tiered offerings in this setting, allowing greater subsidization of low-income patients. Personal familiarity with cataract surgery is important in determining WTP. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: We sought to determine whether corneal biomechanical parameters are predictive of reduction in axial length after anti-metabolite trabeculectomy. METHODS: Chinese subjects undergoing trabeculectomy with mitomycin C by a single experienced surgeon underwent the following measurements: Corneal hysteresis (CH, Ocular Response Analyzer, Reichert Ophthalmic Instruments), Goldmann intra-ocular pressure (IOP), central corneal thickness (CCT) and axial length (AL, IOLMaster, Carl Zeiss Meditec, Dublin, CA) were measured pre-operatively, and AL, CH and IOP were measured 1 day and 1 week post-operatively. RESULTS: Mean age of 31 subjects was 52.0 ± 15.2 years, and 15 (48.4%) were female. The mean pre-operative IOP of 21.4 ± 9.3 mmHg was reduced to 8.2 ± 4.6 mmHg 1 day and 11.0 ± 4.4 mmHg 1 week post-operatively (p < 0.001). AL declined from 22.99 ± 0.90 to 22.76 ± 0.87 mm at 1 day and 22.74 ± 0.9 mm at 1 week; 30/31 (%) eyes had a decline in AL (p < 0.001, sign test). In multivariate linear regression models including post-operative data from 1 day and 1 week, greater decline in Goldmann IOP (p < 0.0001, greater pre-op axial length (p < 0.001) and lower pre-operative CH (p = 0.03), were all associated with greater decline in post-operative axial length. CONCLUSIONS: Eyes with lesser ability of the ocular coat to absorb energy (lower CH) had significantly greater decrease in axial length after trabeculectomy-induced IOP-lowering.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate how potentially functional genetic variants are coinherited on each of four common complement factor H (CFH) and CFH-related gene haplotypes and to measure expression of these genes in eye and liver tissues.

Methods: We sequenced the CFH region in four individuals (one homozygote for each of four common CFH region haplotypes) to identify all genetic variants. We studied associations between the haplotypes and AMD phenotypes in 2157 cases and 1150 controls. We examined RNA-seq profiles in macular and peripheral retina and retinal pigment epithelium/choroid/sclera (RCS) from eight eye donors and three liver samples.

Results: The haplotypic coinheritance of potentially functional variants (including missense variants, novel splice sites, and the CFHR3–CFHR1 deletion) was described for the four common haplotypes. Expression of the short and long CFH transcripts differed markedly between the retina and liver. We found no expression of any of the five CFH-related genes in the retina or RCS, in contrast to the liver, which is the main source of the circulating proteins.

Conclusions: We identified all genetic variants on common CFH region haplotypes and described their coinheritance. Understanding their functional effects will be key to developing and stratifying AMD therapies. The small scale of our expression study prevented us from investigating the relationships between CFH region haplotypes and their expression, and it will take time and collaboration to develop epidemiologic-scale studies. However, the striking difference between systemic and ocular expression of complement regulators shown in this study suggests important implications for the development of intraocular and systemic treatments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microneedles (MNs) are minimally invasive devices consisting of numerous micron-sized projections amassed on a baseplate, designed to enhance transdermal drug delivery. When applied to the skin, the needles puncture the outermost layer, the stratum corneum, forming aqueous conduits through which drugs can diffuse to the dermal microcirculation. With an average length of 50-900 μm, MNs are short enough to avoid stimulation of dermal nerves and do not induce bleeding, yet gain access to the skin's rich microcirculation for drug delivery. MNs have been extensively investigated for drug and vaccine delivery, demonstrating their efficacy at increasing the number of compounds amenable to delivery through the skin. This chapter discusses the materials and fabrication methods involved in MN production, alongside the different types of MN arrays and their delivery capabilities. The field has expanded to consider novel applications of MNs including minimally invasive patient monitoring, ocular delivery and enhanced administration of cosmeceuticals. Patient usage and effects on the skin are also considered in terms of safety, efficacy and acceptability. The next steps in MN development are to focus on the scale-up of manufacturing processes, a challenge considering the number of small-scale methods detailed in the literature. Regulatory guidance is awaited to direct this, alongside provision of clearer patient instruction for safe and effective use of MN devices. MNs have tremendous potential to yield real benefits for patients and industry and with continued research in the key areas highlighted, this will begin to be realised over the next number of years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Glaucoma patients are still at risk of becoming blind. It is of clinical significance to determine the risk of blindness and its causes to prevent its occurrence. This systematic review estimates the number of treated glaucoma patients with end-of-life visual impairment (VI) and blindness and the factors that are associated with this.

METHODS: A systematic literature search in relevant databases was conducted in August 2014 on end-of-life VI. A total of 2574 articles were identified, of which 5 on end-of-life VI. Several data items were extracted from the reports and presented in tables.

RESULTS: All studies had a retrospective design. A considerable number of glaucoma patients were found to be blind at the end of their life; with up to 24% unilateral and 10% bilateral blindness. The following factors were associated with blindness: (1) baseline severity of visual field loss: advanced stage of glaucoma or substantial visual field loss at the initial visit; (2) factors influencing progression: fluctuation of intraocular pressure (IOP) during treatment, presence of pseudoexfoliation, poor patient compliance, higher IOP; (3) longer time period: longer duration of disease and older age at death because of a longer life expectancy; and (4) coexistence of other ocular pathology.

CONCLUSIONS: Further prevention of blindness in glaucoma patients is needed. To reach this goal, it is important to address the risk factors for blindness identified in this review, especially those that can be modified, such as advanced disease at diagnosis, high and fluctuating IOP, and poor compliance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente relatório pretende descrever as atividades desenvolvidas durante o estágio no Hospital Veterinário do Restelo e apresentar a casuística relativa a este período. É apresentado também um estudo de casos sobre uveítes caninas e monografia sobre o tema. A uveíte é uma das afeções oculares mais frequentes nos cães, muitas vezes associada a outras afeções sistémicas. Foi realizado um estudo retrospetivo com 50 cães que se apresentaram neste Hospital nos anos de 2011 e 2012 com diagnóstico primário de uveíte, com o objetivo de caracterizar a distribuição das uveítes na população canina e avaliar as suas causas, em especial a relação com doenças sistémicas. O número de causas oculares identificadas foi igual ao número de causas sistémicas, o que reforça o importante papel de determinadas afeções sistémicas na etiologia da uveíte; ### Abstract Clinic in Small Animals Canine Uveitis: Retrospective Study of 50 cases The present report aims to describe the activities developed during the traineeship in Veterinary Hospital of Restelo and presents the casuistry relating to this period. It also presents a case study about canine uveitis and a monograph about it. Uveitis is one of the most common ocular diseases in dogs, often associated with others systemic diseases. We conducted a retrospective study in 50 dogs presented at the Hospital in 2011 and 2012 with a primary diagnosis of uveitis, with the purpose of characterizing the distribution of uveitis in the dog population and evaluate their causes, in particularly the relationship with systemic diseases. The number of identified ocular causes was equal to the number of systemic causes, which reinforces the important role of certain systemic conditions in the etiology of uveitis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta tese apresenta um sistema de localização baseado exclusivamente em ultrassons, não necessitando de recorrer a qualquer outra tecnologia. Este sistema de localização foi concebido para poder operar em ambientes onde qualquer outra tecnologia não pode ser utilizada ou o seu uso está condicionado, como são exemplo aplicações subaquáticas ou ambientes hospitalares. O sistema de localização proposto faz uso de uma rede de faróis fixos permitindo que estações móveis se localizem. Devido à necessidade de transmissão de dados e medição de distâncias foi desenvolvido um pulso de ultrassons robusto a ecos que permite realizar ambas as tarefas com sucesso. O sistema de localização permite que as estações móveis se localizem escutando apenas a informação em pulsos de ultrassons enviados pelos faróis usando para tal um algoritmo baseado em diferenças de tempo de chegada. Desta forma a privacidade dos utilizadores é garantida e o sistema torna-se completamente independente do número de utilizadores. Por forma a facilitar a implementação da rede de faróis apenas será necessário determinar manualmente a posição de alguns dos faróis, designados por faróis âncora. Estes irão permitir que os restantes faróis, completamente autónomos, se possam localizar através de um algoritmo iterativo de localização baseado na minimização de uma função de custo. Para que este sistema possa funcionar como previsto será necessário que os faróis possam sincronizar os seus relógios e medir a distância entre eles. Para tal, esta tese propõe um protocolo de sincronização de relógio que permite também obter as medidas de distância entre os faróis trocando somente três mensagens de ultrassons. Adicionalmente, o sistema de localização permite que faróis danificados possam ser substituídos sem comprometer a operabilidade da rede reduzindo a complexidade na manutenção. Para além do mencionado, foi igualmente implementado um simulador de ultrassons para ambientes fechados, o qual provou ser bastante preciso e uma ferramenta de elevado valor para simular o comportamento do sistema de localização sobre condições controladas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ocular pathologies are among the most debilitating medical conditions affecting all segments of the population. Traditional treatment options are often ineffective, and gene therapy has the potential to become an alternative approach for the treatment of several pathologies. Methacrylate polymers have been described as highly biocompatible and are successfully used in medical applications. Due to their cationic nature, these polymers can be used to form polyplexes with DNA for its delivery. This work aims to study the potential of PDMAEMA (poly(2-(N,N’-dimethylamino)ethyl methacrylate)) as a non viral gene delivery system to the retina. The first part of this work aimed to study the potential for gene delivery of a previously synthesized PDMAEMA polymer of high molecular weight (354kDa). In the second part, we synthesized by RAFT a PDMAEMA with a lower molecular weight (103.3kDa) and similarly, evaluated its ability to act as a gene delivery vehicle. PDMAEMA/DNA polyplexes were prepared at 5, 7.5, 10, 12.5 and 20 nitrogen/phosphorous (N/P) ratio for the 354kDa PDMAEMA and at 5 and 7.5 for the 103.3kDa PDMAEMA. Dynamic light scattering and zeta potential measurements confirmed the nanosize and positive charge of polyplexes for all ratios and for both polymers. Both high and low Mw PDMAEMA were able to efficiently complex and protect DNA from DNase I degradation. Their cytotoxicity was evaluated using a non-retinal cell line (HEK293) and a retinal pigment epithelium (RPE) cell line (D407). We have found that cytotoxicity of the free polymer is concentration and time dependent, as expected, and negligible for all the concentrations of the PDMAEMA-DNA polyplexes. Furthermore, for the concentrations to be used in vivo, the 354kDa PDMAEMA showed no signs of inflammation upon injection in the intravitreal space of C57BL/6 mice. The transfection efficiency, as evaluated by fluorescence microscopy and flow cytometry, showed that the D407 retinal cells were transfected by polyplexes of both high and low Mw PDMAEMA, but with varied efficiency, which was dependent on the N/P ratio. Althogether, these results suggest that PDMAEMA is a feasible candidate for non-viral gene delivery to the retina, and this work constitutes the basis of further studies to elucidate the bottleneck in transfection and further optimization of the material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de doutoramento, Ciências Biomédicas, Departamento de Ciências Biomédicas e Medicina, Universidade do Algarve, 2015