968 resultados para ultrasound ct
Resumo:
Background: Few data on the definition of simple robust parameters to predict image noise in cardiac computed tomography (CT) exist. Objectives: To evaluate the value of a simple measure of subcutaneous tissue as a predictor of image noise in cardiac CT. Methods: 86 patients underwent prospective ECG-gated coronary computed tomographic angiography (CTA) and coronary calcium scoring (CAC) with 120 kV and 150 mA. The image quality was objectively measured by the image noise in the aorta in the cardiac CTA, and low noise was defined as noise < 30HU. The chest anteroposterior diameter and lateral width, the image noise in the aorta and the skin-sternum (SS) thickness were measured as predictors of cardiac CTA noise. The association of the predictors and image noise was performed by using Pearson correlation. Results: The mean radiation dose was 3.5 ± 1.5 mSv. The mean image noise in CT was 36.3 ± 8.5 HU, and the mean image noise in non-contrast scan was 17.7 ± 4.4 HU. All predictors were independently associated with cardiac CTA noise. The best predictors were SS thickness, with a correlation of 0.70 (p < 0.001), and noise in the non-contrast images, with a correlation of 0.73 (p < 0.001). When evaluating the ability to predict low image noise, the areas under the ROC curve for the non-contrast noise and for the SS thickness were 0.837 and 0.864, respectively. Conclusion: Both SS thickness and CAC noise are simple accurate predictors of cardiac CTA image noise. Those parameters can be incorporated in standard CT protocols to adequately adjust radiation exposure.
Resumo:
[EN] OBJECTIVE: To determine the value of ultrasonography in the assessment of patients with idiopathic carpal tunnel syndrome (CTS) and poor outcome after carpal tunnel release. METHODS: A total of 88 consecutive patients with CTS (104 hands) underwent open surgical release of the median nerve. Ultrasound (US) examination was performed blind to any patient's data. The median nerve area at tunnel inlet and outlet, the retinaculum distance, and the flattening ratio were measured. The main outcome variable was the patient's overall satisfaction using a five-point Likert scale (1 = worse, 2 = no change, 3 = slightly better, 4 = much better, 5 = cured) at 3 months postoperatively. Pre- and postoperative ultrasonographic findings in relation to clinical outcome were analysed. RESULTS: Improvement (scores 4 or 5 on the Likert scale) was recorded in 75 hands (72%). After carpal tunnel release, the cross-sectional area at tunnel inlet decreased from a mean of 14.2 to 13.3 mm2 in the group with clinical improvement and also from a mean of 12.5 to 11.6 mm2 in the group with no change or slight improvement. No significant changes in the cross-sectional area at tunnel outlet, retinaculum distance, and flattening ratio were observed. CONCLUSION: Reduction of the median nerve cross-sectional area at tunnel inlet at 3 months after carpal tunnel release was similar in patients reporting cure or great improvement and in those with slight or no improvement. Ultrasonography is of limited value in assessment of patients with poor outcome after median nerve release.
Resumo:
Background: Congenital cytomegalovirus (CMV) infection may lead to cerebral injury and neurodevelopmental delay. Cranial computed tomography (CT) is currently the standard imaging technique for predicting the outcome of CMV infected patients. Ultrasound (US) is a safe means to assess the extent of cerebral injury due to CMV infection in neonates, and unlike CT, is readily available at the bedside. Aim: To report the accuracy of US in predicting neurodevelopmental and sensorineural outcome in patients with congenital CMV infection. Study design: 57 newborns with congenital CMV infection underwent brain US and were followed prospectively for motor skills, developmental quotient and hearing function. Results: An abnormal US was found in 12/57 newborns. At least one sequela (Developmental Quotient < 85, motor delay, sensorineural hearing loss) was present in 10/11 surviving children with abnormal US (1 patient died in the neonatal period) vs 3/45 newborns with normal US (OR for death or poor outcome: 154, CI 17.3-1219.6, p<0.001, positive predictive value 91.7%, negative predictive value 93.3%). Conclusion: A good correlation is shown between ultrasound abnormalities and the prediction of outcome, suggesting that US may be used to study and follow CMV infected neonates. Our findings await confirmation in a larger population.
Resumo:
[ES]The purpose of this paper was to use threedimensional computed tomographic reconstruction as another tool to teach in the veterinary colleges. 2-millimeters thick transverse images of two foals and one dog were obtained. Images provided excellent detail of relevant anatomic structures and detailed information regarding the extent of disease and accurate discrimination of neoplastic versus non-neoplastic diseases. Tridimensional reconstruction can be a valuable diagnostic aid for clinical evaluation of several disturbances and could be used as a tool for teaching anatomy in veterinary schools.
Resumo:
Aim: To evaluate the early response to treatment to an antiangiogenetic drug (sorafenib) in a heterotopic murine model of hepatocellular carcinoma (HCC) using ultrasonographic molecular imaging. Material and Methods: the xenographt model was established injecting a suspension of HuH7 cells subcutaneously in 19 nude mice. When tumors reached a mean diameter of 5-10 mm, they were divided in two groups (treatment and vehicle). The treatment group received sorafenib (62 mg/kg) by daily oral gavage for 14 days. Molecular imaging was performed using contrast enhanced ultrasound (CEUS), by injecting into the mouse venous circulation a suspension of VEGFR-2 targeted microbubbles (BR55, kind gift of Bracco Swiss, Geneve, Switzerland). Video clips were acquired for 6 minutes, then microbubbles (MBs) were destroyed by a high mechanical index (MI) impulse, and another minute was recorded to evaluate residual circulating MBs. The US protocol was repeated at day 0,+2,+4,+7, and +14 from the beginning of treatment administration. Video clips were analyzed using a dedicated software (Sonotumor, Bracco Swiss) to quantify the signal of the contrast agent. Time/intensity curves were obtained and the difference of the mean MBs signal before and after high MI impulse (Differential Targeted Enhancement-dTE) was calculated. dTE represents a numeric value in arbitrary units proportional to the amount of bound MBs. At day +14 mice were euthanized and the tumors analyzed for VEGFR-2, pERK, and CD31 tissue levels using western blot analysis. Results: dTE values decreased from day 0 to day +14 both in treatment and vehicle groups, and they were statistically higher in vehicle group than in treatment group at day +2, at day +7, and at day +14. With respect to the degree of tumor volume increase, measured as growth percentage delta (GPD), treatment group was divided in two sub-groups, non-responders (GPD>350%), and responders (GPD<200%). In the same way vehicle group was divided in slow growth group (GPD<400%), and fast growth group (GPD>900%). dTE values at day 0 (immediately before treatment start) were higher in non-responders than in responders group, with statistical difference at day 2. While dTE values were higher in the fast growth group than in the slow growth group only at day 0. A significant positive correlation was found between VEGFR-2 tissue levels and dTE values, confirming that level of BR55 tissue enhancement reflects the amount of tissue VEGF receptor. Conclusions: the present findings show that, at least in murine experimental models, CEUS with BR55 is feasable and appears to be a useful tool in the prediction of tumor growth and response to sorafenib treatment in xenograft HCC.
Resumo:
In this thesis two major topics inherent with medical ultrasound images are addressed: deconvolution and segmentation. In the first case a deconvolution algorithm is described allowing statistically consistent maximum a posteriori estimates of the tissue reflectivity to be restored. These estimates are proven to provide a reliable source of information for achieving an accurate characterization of biological tissues through the ultrasound echo. The second topic involves the definition of a semi automatic algorithm for myocardium segmentation in 2D echocardiographic images. The results show that the proposed method can reduce inter- and intra observer variability in myocardial contours delineation and is feasible and accurate even on clinical data.
Resumo:
Vergleich von Datensätzen,die mit Hilfe von den Programmen "Volume©","Pulmo©", "Yacta©" und PulmoFUNC(ILab) erstellt wurden. Dabei wurden jeweils die Lungen- und Emphysemvolumina verglichen, die mit den 4 Programmen ermittelt wurden. Außerdem wurde noch die mittlere Lungendichte als Mittelwert aller Lungenvoxel bestimmt. Zusätzlich wurde noch der Emphysemindex als Quotient aus Emphysem- und Lungenvolumina errechnet. Die Programme waren unterschiedlich benutzerfreundlich in der Bearbeitung: Die weitestgehend manuell zu bearbeitenden Programme Volume© und Pulmo© benötigten zur Bearbeitung deutlich mehr Zeit als die überwiegend automatisch arbeitenden Programme Yacta und PulmoFUNC(ILab).
Resumo:
Introduction Lower pole kidney stones represent at time a challenge for the urologist. The gold standard treatment for intrarenal stones <2 cm is Extracorporeal Shock Wave Lithotripsy (ESWL) while for those >2 cm is Percutaneous Nephrolithotomy (PCNL). The success rate of ESWL, however, decreases when it is employed for lower pole stones, and this is particularly true in the presence of narrow calices or acute infundibular angles. Studies have proved that ureteroscopy (URS) is an efficacious alternative to ESWL for lower pole stones <2 cm, but this is not reflected by either the European or the American guidelines. The aim of this study is to present the results of a large series of flexible ureteroscopies and PCNLs for lower pole kidney stones from high-volume centers, in order to provide more evidences on the potential indications of the flexible ureteroscopy for the treatment of kidney stones. Materials and Methods A database was created and the participating centres retrospectively entered their data relating to the percutaneous and flexible ureteroscopic management of lower pole kidney stones. Patients included were treated between January 2005 and January 2010. Variables analyzed included case load number, preoperative and postoperative imaging, stone burden, anaesthesia (general vs. spinal), type of lithotripter, access location and size, access dilation type, ureteral access sheath use, visual clarity, operative time, stone-free rate, complication rate, hospital stay, analgesic requirement and follow-up time. Stone-free rate was defined as absence of residual fragments or presence of a single fragment <2 mm in size at follow-up imaging. Primary end-point was to test the efficacy and safety of flexible URS for the treatment of lower pole stones; the same descriptive analysis was conducted for the PCNL approach, as considered the gold standard for the treatment of lower pole kidney stones. In this setting, no statistical analysis was conducted owing to the different selection criteria of the patients. Secondary end-point consisted in matching the results of stone-free rates, operative time and complications rate of flexible URS and PCNL in the subgroup of patients harbouring lower pole kidney stones between 1 and 2 cm in the higher diameter. Results A total 246 patients met the criteria for inclusion. There were 117 PCNLs (group 1) and 129 flexible URS (group 2). Ninety-six percent of cases were diagnosed by CT KUB scan. Mean stone burden was 175±160 and 50±62 mm2 for groups 1 and 2, respectively. General anaesthesia was induced in 100 % and 80% of groups 1 and 2, respectively. Pneumo-ultrasonic energy was used in 84% of cases in the PCNL group, and holmium laser in 95% of the cases in the flexible URS group. The mean operative time was 76.9±44 and 63±37 minutes for groups 1 and 2 respectively. There were 12 major complications (11%) in group 1 (mainly Grade II complications according to Clavidien classification) and no major complications in group 2. Mean hospital stay was 5.7 and 2.6 days for groups 1 and 2, respectively. Ninety-five percent of group 1 and 52% of group 2 required analgesia for a period longer than 24 hours. Intraoperative stone-free rate after a single treatment was 88.9% for group 1 and 79.1% for group 2. Overall, 6% of group 1 and 14.7% of group 2 required a second look procedure. At 3 months, stone-free rates were 90.6% and 92.2% for groups 1 and 2, respectively, as documented by follow-up CT KUB (22%) or combination of intra-venous pyelogram, regular KUB and/or kidney ultrasound (78%). In the subanalysis conducted comparing 82 vs 65 patients who underwent PCNL and flexible URS for lower pole stones between 1 and 2 cm, intreoperative stone-free rates were 88% vs 68% (p= 0.03), respectively; anyway, after an auxiliary procedure which was necessary in 6% of the cases in group 1 and 23% in group 2 (p=0.03), stone-free rates at 3 months were not statistically significant (91.5% vs 89.2%; p=0.6). Conversely, the patients undergoing PCNL maintained a higher risk of complications during the procedure, with 9 cases observed in this group versus 0 in the group of patients treated with URS (p=0.01) Conclusions These data highlight the value of flexible URS as a very effective and safe option for the treatment of kidney stones; thanks to the latest generation of flexible devices, this new technical approach seems to be a valid alternative in particular for the treatment of lower pole kidney stones less than 2 cm. In high-volume centres and in the hands of skilled surgeons, this technique can approach the stone-free rates achievable through PCNL in lower pole stones between 1 and 2 cm, with a very low risk of complications. Furthermore, the results confirm the high success rate and relatively low morbidity of modern PCNL for lower pole stones, with no difference detectable between the prone and supine position.
Resumo:
Die zuverlässige Berechnung von quantitativen Parametern der Lungenventilation ist für ein Verständnis des Verhaltens der Lunge und insbesondere für die Diagnostik von Lungenerkrankungen von großer Bedeutung. Nur durch quantitative Parameter sind verlässliche und reproduzierbare diagnostische Aussagen über den Gesundheitszustand der Lunge möglich. Im Rahmen dieser Arbeit wurden neue quantitative Verfahren zur Erfassung der Lungenventilation basierend auf der dynamischen Computer- (CT) und Magnetresonanztomographie (MRT) entwickelt. Im ersten Teil dieser Arbeit wurde die Frage untersucht, ob das Aufblähen der Lunge in gesunden Schweinelungen und Lungen mit Akutem Lungenversagen (ARDS) durch einzelne, diskrete Zeitkonstanten beschrieben werden kann, oder ob kontinuierliche Verteilungen von Zeitkonstanten die Realität besser beschreiben. Hierzu wurden Serien dynamischer CT-Aufnahmen während definierter Beatmungsmanöver (Drucksprünge) aufgenommen und anschließend aus den Messdaten mittels inverser Laplace-Transformation die zugehörigen Verteilungen der Zeitkonstanten berechnet. Um die Qualität der Ergebnisse zu analysieren, wurde der Algorithmus im Rahmen von Simulationsrechnungen systematisch untersucht und anschließend in-vivo an gesunden und ARDS-Schweinelungen eingesetzt. Während in den gesunden Lungen mono- und biexponentielle Verteilungen bestimmt wurden, waren in den ARDS-Lungen Verteilungen um zwei dominante Zeitkonstanten notwendig, um die gemessenen Daten auf der Basis des verwendeten Modells verlässlich zu beschreiben. Es wurden sowohl diskrete als auch kontinuierliche Verteilungen gefunden. Die CT liefert Informationen über das solide Lungengewebe, während die MRT von hyperpolarisiertem 3He in der Lage ist, direkt das eingeatmete Gas abzubilden. Im zweiten Teil der Arbeit wurde zeitlich hochaufgelöst das Einströmen eines 3He-Bolus in die Lunge erfasst. Über eine Entfaltungsanalyse wurde anschließend das Einströmverhalten unter Idealbedingungen (unendlich kurzer 3He-Bolus), also die Gewebeantwortfunktion, berechnet und so eine Messtechnik-unabhängige Erfassung des Einströmens von 3He in die Lunge ermöglicht. Zentrale Fragestellung war hier, wie schnell das Gas in die Lunge einströmt. Im Rahmen von Simulationsrechnungen wurde das Verhalten eines Entfaltungsalgorithmus (basierend auf B-Spline Repräsentationen) systematisch analysiert. Zusätzlich wurde ein iteratives Entfaltungsverfahren eingesetzt. Aus zeitlich hochaufgelösten Messungen (7ms) an einer gesunden und einer ARDS-Schweinelunge konnte erstmals nachgewiesen werden, dass das Einströmen in-vivo in weniger als 0,1s geschieht. Die Ergebnisse zeigen Zeitkonstanten im Bereich von 4ms–50ms, wobei zwischen der gesunden Lungen und der ARDS-Lunge deutliche Unterschiede beobachtet wurden. Zusammenfassend ermöglichen daher die in dieser Arbeit vorgestellten Algorithmen eine objektivere Bestimmung quantitativer Parameter der Lungenventilation. Dies ist für die eindeutige Beschreibung ventilatorischer Vorgänge in der Lunge und somit für die Lungendiagnostik unerlässlich. Damit stehen quantitative Methoden für die Lungenfunktionsdiagnostik zur Verfügung, deren diagnostische Relevanz im Rahmen wissenschaftlicher und klinischer Studien untersucht werden kann.
Resumo:
Background: The recent increasing incidence of intrahepatic cholangiocellular carcinoma (ICC) in cirrhosis increased the problem of noninvasive differential diagnosis between ICC and hepatocellular carcinoma (HCC) in cirrhosis. In literature there isn’t data about treatment and prognosis of ICC in cirrhosis. Aim: To investigate the role of the different imaging techniques in the diagnosis of ICC in cirrhosis; to analyze treatments and prognosis with particular attention to factors associated with survival. Methods: The data of 30 cirrhotic patients with ICC were retrospectively collected; patients were referred to Liver Units (S.Orsola-Malpighi and S.Matteo Hospitals) between 2005 and 2011. The results of contrast-enhanced ultrasound (CEUS), computed tomography (CT) and magnetic resonance (MR) were evaluated; the enhancement pattern at different imaging techniques were analysed, with particular attention to misdiagnosis of HCC. We evaluated the different treatments and survival of the study group and then we performed the survival analysis of different clinico-pathologic factors. Results: Twenty-five patients underwent CEUS, 27 CT and 10 MR. In 3 cases (12%) CEUS misdiagnosed ICC for HCC, in 7 cases (26%) CT misdiagnosed ICC and in 1 case (10%) MR misdiagnosed ICC. Patient were followed for a mean of 30 months (range:4-86), with a mean survival of 30 months. Twenty-four out of 30 patients were treated with curative approach, while the other 6 underwent TACE (n=4), radioembolization (n=1) or systemic treatment with Gemcitabine (n=1). The univariate analysis revealed that CA19-9 levels, surveillance program and nodule size were significantly related with survival. By multivariate analysis only nodule size £ 40mm was significant (p=0,004). Conclusion: Diagnosis of ICC in cirrhosis remains difficult because there isn’t a typical enhancement pattern and in some cases it cannot be distinguished from HCC by the different imaging techniques. The study of survival related factors shows that nodule size ≤ 40mm is correlated with improved survival.
Resumo:
Auf der Suche nach dem „vulnerablen Plaque“, der ein besonders hohes Risiko für Schlaganfall und Herzinfarkt besitzt, findet momentan ein Paradigmenwechsel statt. Anstelle des klassischen Stenosegrades gewinnt die Darstellung der Plaquemorphologie zunehmend an Bedeutung. Fragestellung: Ziel dieser Arbeit ist es, die Fähigkeiten eines modernen 16-Kanal-CT hinsichtlich der Auflösung des Plaqueinneren bei Atherosklerose der Karotiden zu untersuchen und den Halo-Effekt in vivo zu erforschen. Methoden: Für die Studie wurden von 28 Patienten mit bekannter, symptomatischer Karotisstenose vor der gefäßchirurgischen Intervention CT-Bilder angefertigt, die nachfolgend mit der Histologie der Gefäßpräparate korreliert wurden. Auf diese Weise konnten die mikroskopisch identifizierten Lipidkerne im CT-Bild eingezeichnet und hinsichtlich ihrer Fläche und Dichtewerte evaluiert werden. In einem weiteren Schritt führten 2 Radiologen in Unkenntnis der histologischen Ergebnisse unabhängig voneinander eine Befundung durch und markierten mutmaßliche Lipidkerne. Zudem wurden sowohl in der verblindeten als auch in der histologiekontrollierten Auswertung die Plaquetypen anhand der AHA-Klassifikation bestimmt. Ein dritter Befundungsdurchgang geschah unter Zuhilfenahme einer von uns entwickelten Software, die CT-Bilder farbkodiert um die Detektion der Lipidkerne zu verbessern. Anhand der Farbkodierung wurde zudem ein Indexwert errechnet, der eine objektive Zuordnung zur AHA-Klassifikation ermöglichen sollte. Von 6 Patienten wurde zusätzlich noch eine native CT-Aufnahme angefertigt, die durch MPR exakt an die Kontrastmittelserie angeglichen wurde. Auf diese Weise konnte der Halo-Effekt, der die Plaqueanteile im lumennahen Bereich überstrahlt, quantifiziert und charakterisiert werden. Ergebnisse: Während die Einstufung in die AHA-Klassifikation sowohl durch den Befunder als auch durch den Softwarealgorithmus eine hohe Korrelation mit der Histologie aufweist (Typ IV/Va: 89 %, Typ Vb: 70 %, Typ Vc: 89 %, Typ VI: 55 %), ist die Detektion der Lipidkerne in beiden Fällen nicht ausreichend gut und die Befunderabhängigkeit zu groß (Cohens Kappa: 18 %). Eine Objektivierung der AHA-Klassifikation der Plaques durch Indexberechnung nach Farbkodierung scheint möglich, wenn auch dem Befunder nicht überlegen. Die fibröse Kappe kann nicht abgegrenzt werden, da Überstrahlungseffekte des Kontrastmittels dessen HU-Werte verfälschen. Dieser Halo-Effekt zeigte sich im Median 1,1 mm breit mit einer Standardabweichung von 0,38 mm. Eine Abhängigkeit von der Kontrastmitteldichte im Gefäßlumen konnte dabei nicht nachgewiesen werden. Der Halo-Effekt fiel im Median um -106 HU/mm ab, bei einer Standardabweichung von 33 HU/mm. Schlussfolgerung: Die CT-Technologie zeigt sich, was die Darstellung von einzelnen Plaquekomponenten angeht, den bekannten Fähigkeiten der MRT noch unterlegen, insbesondere in Bezug auf die fibröse Kappe. Ihre Fähigkeiten liegen bisher eher in der Einstufung von Plaques in eine grobe Klassifikation, angelehnt an die der AHA. Die klinische Relevanz dessen jedoch gilt es in Zukunft in größeren Studien weiter zu untersuchen. Auch lässt die Weiterentwicklung der Computertomographie auf eine zukünftig höhere Auflösung der Plaquemorphologie hoffen.
Resumo:
This master’s thesis describes the research done at the Medical Technology Laboratory (LTM) of the Rizzoli Orthopedic Institute (IOR, Bologna, Italy), which focused on the characterization of the elastic properties of the trabecular bone tissue, starting from october 2012 to present. The approach uses computed microtomography to characterize the architecture of trabecular bone specimens. With the information obtained from the scanner, specimen-specific models of trabecular bone are generated for the solution with the Finite Element Method (FEM). Along with the FEM modelling, mechanical tests are performed over the same reconstructed bone portions. From the linear-elastic stage of mechanical tests presented by experimental results, it is possible to estimate the mechanical properties of the trabecular bone tissue. After a brief introduction on the biomechanics of the trabecular bone (chapter 1) and on the characterization of the mechanics of its tissue using FEM models (chapter 2), the reliability analysis of an experimental procedure is explained (chapter 3), based on the high-scalable numerical solver ParFE. In chapter 4, the sensitivity analyses on two different parameters for micro-FEM model’s reconstruction are presented. Once the reliability of the modeling strategy has been shown, a recent layout for experimental test, developed in LTM, is presented (chapter 5). Moreover, the results of the application of the new layout are discussed, with a stress on the difficulties connected to it and observed during the tests. Finally, a prototype experimental layout for the measure of deformations in trabecular bone specimens is presented (chapter 6). This procedure is based on the Digital Image Correlation method and is currently under development in LTM.
Resumo:
La chirurgia con ultrasuoni focalizzati guidati da MRI (MR-g-FUS) è un trattamento di minima invasività, guidato dal più sofisticato strumento di imaging a disposizione, che utilizza a scopo diagnostico e terapeutico forme di energia non ionizzante. Le sue caratteristiche portano a pensare un suo possibile e promettente utilizzo in numerose aree della patologia umana, in particolare scheletrica. L'osteoma osteoide affligge frequentemente pazienti di giovane età, è una patologia benigna, con origine ed evoluzione non chiare, e trova nella termoablazione con radiofrequenza continua sotto guida CT (CT-g-RFA) il suo trattamento di elezione. Questo lavoro ha valutato l’efficacia, gli effetti e la sicurezza del trattamento dell’osteoma osteoide con MR-g-FUS. Sono stati presi in considerazione pazienti arruolati per MR-g-FUS e, come gruppo di controllo, pazienti sottoposti a CT-g-RFA, che hanno raggiunto un follow-up minimo di 18 mesi (rispettivamente 6 e 24 pazienti). Due pazienti erano stati esclusi dal trattamento MR-g-FUS per claustrofobia (2/8). Tutti i trattamenti sono stati portati a termine con successo tecnico e clinico. Non sono state registrate complicanze o eventi avversi correlati all’anestesia o alle procedure di trattamento, e tutti i pazienti sono stati dimessi regolarmente dopo 12-24 ore. La durata media dei trattamenti di MR-g-FUS è stata di 40±21 min. Da valori di score VAS pre-trattamento oscillanti tra 6 e 10 (su scala 0-10), i trattamenti hanno condotto tutti i pazienti a VAS 0 (senza integrazioni farmacologiche). Nessun paziente ha manifestato segni di persistenza di malattia o di recidiva al follow-up. Nonostante la neurolisi e la risoluzione dei sintomi, la perfusione del nidus è stata ritrovata ancora presente in oltre il 70% dei casi sottoposti a MR-g-FUS (4/6 pazienti). I risultati derivati da un'analisi estesa a pazienti più recentemente arruolati confermano questi dati. Il trattamento con MR-g-FUS sembra essere efficace e sicuro nel risolvere la sintomatologia dell'osteoma osteoide.