985 resultados para transverse cracking


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To preliminarily evaluate prospectively the accuracy and reliability of a specific ad hoc reduction-compression forceps in intraoral open reduction of transverse and displaced mandibular angle fractures. STUDY DESIGN: We analyzed the clinical and radiologic data of 7 patients with 7 single transverse and displaced angle fractures. An intraoral approach was performed in all of the patients without using perioperative intermaxillary fixation. A single Arbeitsgemeinschaft Osteosynthese (AO) unilock reconstruction plate was fixed to each stable fragment with 3 locking screws (2.0 mm in 5 patients and 2.4 mm in 2 patients) at the basilar border of the mandible, according to AO/American Society of Internal Fixation (ASIF) principles. Follow-up was at 1, 3, 6, and 12 months, and we noted the status of healing and complications, if any. RESULTS: All of the patients had satisfactory fracture reduction as well as a successful treatment outcome without complications. CONCLUSION: This preliminary study demonstrated that the intraoral reduction of transverse and displaced angle fractures using a specific ad hoc reduction-forceps results in a high rate of success.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Load transfer across transverse joints has always been a factor contributing to the useful life of concrete pavements. For many years, round steel dowels have been the conventional load transfer mechanism. Many problems have been associated with the round steel dowels. The most detrimental effect of the steel dowel is corrosion. Repeated loading over time also damages joints. When a dowel is repeatedly loaded over a long period of time, the high bearing stresses found at the top and bottom edge of a bar erode the surrounding concrete. This oblonging creates multiple problems in the joint. Over the past decade, Iowa State University has performed extensive research on new dowel shapes and materials to mitigate the effects of oblonging and corrosion. This report evaluates the bearing stress performance of six different dowel bar types subjected to two different shear load laboratory test methods. The first load test is the AASHTO T253 method. The second procedure is an experimental cantilevered dowel test. The major objective was to investigate and improve the current AASHTO T253 test method for determining the modulus of dowel support, k0. The modified AASHTO test procedure was examined alongside an experimental cantilever dowel test. The modified AASHTO specimens were also subjected to a small-scale fatigue test in order to simulate long-term dowel behavior with respect to concrete joint damage. Loss on ignition tests were also performed on the GFRP dowel specimens to determine the resin content percentage. The study concluded that all of the tested dowel bar shapes and materials were adequate with respect to performance under shear loading. The modified AASHTO method yielded more desirable results than the ones obtained from the cantilever test. The investigators determined that the experimental cantilever test was not a satisfactory test method to replace or verify the AASHTO T253 method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Due to patency of the arterial duct and the parallel circulation during the fetal life, coarctation remains a difficult diagnosis prenatally and even shortly after birth. Fisrtly, our study aimed to assess accuracy of a new cardiographie index based on morphologie measurements of the distal aortic arch, the Carotid-Subclavian Artery Index (CSA Index), the ratio of the distal transverse aortic arch diameter to the distance between the left carotid artery and the left subclavian artery, in detecting coarctation in newborns, infants and children, independently of other cardiac lesions. Secondly, to assess the additive value of another morphologie index in predicting coarctation, the 1/0 ratio, the ratio of isthmus to descending aorta diameter. Methods: It is a retrospective cohort study in a tertiary care children's hospital. Offline echocardiographic measurements of great vessels and aortic arch dimensions were done in 69 patients with coarctation. We calculate their CSA index, and their 1/0 ratio. Values of CSA Index and 1/0 ratio from coarctation group were compared with those from a normal local control population. Results: 69 echocardiograms from patients with coarctation were analysed. Compared with controls, patients with coarctation had a significantly lower CSA index (0.88 ±0.49 vs 2.65 ±0.82, p <0.0001) and 1/0 ratio. The same significant difference was observed, independently of age and other associated defects, even complex ones. CSA Index confirmed its good sensitivity and specificity (99% and 96% respectively). This was not improved by adding the I/D ratio. Conclusions: An abnormal CSA index is highly suggestive of coarctation independently of age, of the presence of a patent ductus arteriosus or of other cardiac defects. The addition of another anatomie index, the I/D ratio, was not helpful in our study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Various test methods exist for measuring heat of cement hydration; however, most current methods require expensive equipment, complex testing procedures, and/or extensive time, thus not being suitable for field application. The objectives of this research are to identify, develop, and evaluate a standard test procedure for characterization and quality control of pavement concrete mixtures using a calorimetry technique. This research project has three phases. Phase I was designed to identify the user needs, including performance requirements and precision and bias limits, and to synthesize existing test methods for monitoring the heat of hydration, including device types, configurations, test procedures, measurements, advantages, disadvantages, applications, and accuracy. Phase II was designed to conduct experimental work to evaluate the calorimetry equipment recommended from the Phase I study and to develop a standard test procedure for using the equipment and interpreting the test results. Phase II also includes the development of models and computer programs for prediction of concrete pavement performance based on the characteristics of heat evolution curves. Phase III was designed to study for further development of a much simpler, inexpensive calorimeter for field concrete. In this report, the results from the Phase I study are presented, the plan for the Phase II study is described, and the recommendations for Phase III study are outlined. Phase I has been completed through three major activities: (1) collecting input and advice from the members of the project Technical Working Group (TWG), (2) conducting a literature survey, and (3) performing trials at the CP Tech Center’s research lab. The research results indicate that in addition to predicting maturity/strength, concrete heat evolution test results can also be used for (1) forecasting concrete setting time, (2) specifying curing period, (3) estimating risk of thermal cracking, (4) assessing pavement sawing/finishing time, (5) characterizing cement features, (6) identifying incompatibility of cementitious materials, (7) verifying concrete mix proportions, and (8) selecting materials and/or mix designs for given environmental conditions. Besides concrete materials and mix proportions, the configuration of the calorimeter device, sample size, mixing procedure, and testing environment (temperature) also have significant influences on features of concrete heat evolution process. The research team has found that although various calorimeter tests have been conducted for assorted purposes and the potential uses of calorimeter tests are clear, there is no consensus on how to utilize the heat evolution curves to characterize concrete materials and how to effectively relate the characteristics of heat evolution curves to concrete pavement performance. The goal of the Phase II study is to close these gaps.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of precast, prestressed concrete piles in the foundation of bridge piers has long been recognized as a valuable option for bridge owners and designers. However, the use of these precast, prestressed concrete piles in integral abutment bridges has not been widespread because of concerns over pile flexibility and the potential for concrete cracking and deterioration of the prestressing strands due to long-term exposure to moisture. This report presents the details of the first integral abutment bridge in the state of Iowa that utilized precast, prestressed concrete piles in the abutment. The bridge, which was constructed in Tama County in 2000, consists of a 110 ft. long, 30 ft. wide, single-span PC girder superstructure with a left-side-ahead 20º skew angle. The bridge was instrumented with a variety of strain gages, displacement sensors, and thermocouples to monitor and help in the assessment of structural behavior. The results of this monitoring are presented, and recommendations are made for future application of precast, prestressed concrete piles in integral abutment bridges. In addition to the structural monitoring data, this report presents the results of a survey questionnaire that had been mailed to each of the 50 state DOT chief bridge engineers to ascertain their current practices for precast, prestressed concrete piles and especially the application of these piles in integral abutment bridges.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: In vitro mechanical injury of articular cartilage is useful to identify events associated with development of post-traumatic osteoarthritis (OA). To date, many in vitro injury models have used animal cartilage despite the greater clinical relevance of human cartilage. We aimed to characterize a new in vitro injury model using elderly human femoral head cartilage and compare its behavior to that of an existing model with adult bovine humeral head cartilage. DESIGN: Mechanical properties of human and bovine cartilage disks were characterized by elastic modulus and hydraulic permeability in radially confined axial compression, and by Young's modulus, Poisson's ratio, and direction-dependent radial strain in unconfined compression. Biochemical composition was assessed in terms of tissue water, solid, and glycosaminoglycan (GAG) contents. Responses to mechanical injury were assessed by observation of macroscopic superficial tissue cracks and histological measurements of cell viability following single injurious ramp loads at 7 or 70%/s strain rate to 3 or 14 MPa peak stress. RESULTS: Confined compression moduli and Young's moduli were greater in elderly human femoral cartilage vs adult bovine humeral cartilage whereas hydraulic permeability was less. Radial deformations of axially compressed explant disks were more anisotropic (direction-dependent) for the human cartilage. In both cartilage sources, tissue cracking and associated cell death during injurious loading was common for 14 MPa peak stress at both strain rates. CONCLUSION: Despite differences in mechanical properties, acute damage induced by injurious loading was similar in both elderly human femoral cartilage and adult bovine humeral cartilage, supporting the clinical relevance of animal-based cartilage injury models. However, inherent structural differences such as cell density may influence subsequent cell-mediated responses to injurious loading and affect the development of OA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: To compare the delineations and interpretations of target volumes by physicians in different radio-oncology centers. MATERIALS AND METHODS: Eleven Swiss radio-oncology centers delineated volumes according to ICRU 50 recommendations for one prostate and one head and neck case. In order to evaluate the consistency of the volume delineations, the following parameters were determined: 1) the target volumes (GTV, CTV and manually expanded PTV) and their extensions in the three main axes and 2) the correlation of the volume delineated by each pair of centers using the ratio of the intersection to the union (called proximity index). RESULTS: The delineated prostate volume was 105+/-55cm(3) for the CTV and 218+/-44cm(3) for the PTV. The delineated head and neck volume was 46+/-15cm(3) for the GTV, 327+/-154cm(3) for the CTV and 528+/-106cm(3) for the PTV. The mean proximity index for the prostate case was 0.50+/-0.13 for the CTV and 0.57+/-0.11 for the PTV. The proximity index for the head and neck case was 0.45+/-0.09 for the GTV, 0.42+/-0.13 for the CTV and 0.59+/-0.06 for the PTV. CONCLUSIONS: Large discrepancies between all the delineated target volumes were observed. There was an inverse relationship between the CTV volume and the margin between CTV and PTV, leading to less discrepancies in the PTV than is the CTV delineations. There was more spread in the sagittal and frontal planes due to CT pixel anisotropy, which suggests that radiation oncologists should delineate the target volumes not only in the transverse plane, but also in the sagittal and frontal planes to improve the delineation by allowing a consistency check.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

this study presents a review of published geological data, combined with original observations on the tectonics of the simplon massif and the Lepontine gneiss dome in the Western Alps. New observations concern the geometry of the Oligocene Vanzone back fold, formed under amphibolite facies conditions, and of its root between Domodossola and Locarno, which is cut at an acute angle by the Miocene, epi- to anchizonal, dextral centovalli strike-slip fault. the structures of the simplon massif result from collision over 50 Ma between two plate boundaries with a different geometry: the underthrusted European plate and the Adriatic indenter. Detailed mapping and analysis of a complex structural interference pattern, combined with observations on the metamorphic grade of the superimposed structures and radiometric data, allow a kinematic model to be developed for this zone of oblique continental collision. the following main Alpine tectonic phases and structures may be distinguished: 1. NW-directed nappe emplacement, starting in the Early Eocene (similar to 50 Ma); 2. W, SW and S- verging transverse folds; 3. transpressional movements on the dextral simplon ductile shear zone since similar to 32 Ma; 4. formation of the Bergell - Vanzone backfolds and of the southern steep belt during the Oligocene, emplacement of the mantle derived 31 - 29 Ma Bergell and Biella granodiorites and porphyritic andesites as well as intrusions of 29-25 Ma crustal aplites and pegmatites; 5. formation of the dextral discrete Rhone-Simplon line and the centovalli line during the Miocene, accompanied by the pull-apart development of the Lepontine gneiss dome - Dent blanche (Valpelline) depression. It is suggested that movements of shortening in fan shaped NW, W and sW directions accompanied the more regular NW- to WNW-directed displacement of the Adriatic indenter during continental collision.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

At 3 T, the effective wavelength of the RF field is comparable to the dimension of the human body, resulting in B1 standing wave effects and extra variations in phase. This effect is accompanied by an increase in B0 field inhomogeneity compared to 1.5 T. This combination results in nonuniform magnetization preparation by the composite MLEV weighted T2 preparation (T2 Prep) sequence used for coronary magnetic resonance angiography (MRA). A new adiabatic refocusing T2 Prep sequence is presented in which the magnetization is tipped into the transverse plane with a hard RF pulse and refocused using a pair of adiabatic fast-passage RF pulses. The isochromats are subsequently returned to the longitudinal axis using a hard RF pulse. Numerical simulations predict an excellent suppression of artifacts originating from B1 inhomogeneity while achieving good contrast enhancement between coronary arteries and surrounding tissue. This was confirmed by an in vivo study, in which coronary MR angiograms were obtained without a T2 Prep, with an MLEV weighted T2 Prep and the proposed adiabatic T2 Prep. Improved quantitative and qualitative coronary MRA image measurement was achieved using the adiabatic T2 Prep at 3 T.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cobalt-labelled motoneuron dendrites of the frog spinal cord at the level of the second spinal nerve were photographed in the electron microscope from long series of ultrathin sections. Three-dimensional computer reconstructions of 120 dendrite segments were analysed. The samples were taken from two locations: proximal to cell body and distal, as defined in a transverse plane of the spinal cord. The dendrites showed highly irregular outlines with many 1-2 microns-long 'thorns' (on average 8.5 thorns per 100 microns 2 of dendritic area). Taken together, the reconstructed dendrite segments from the proximal sites had a total length of about 250 microns; those from the distal locations, 180 microns. On all segments together there were 699 synapses. Nine percent of the synapses were on thorns, and many more close to their base on the dendritic shaft. The synapses were classified in four groups. One third of the synapses were asymmetric with spherical vesicles; one half were symmetric with spherical vesicles; and one tenth were symmetric with flattened vesicles. A fourth, small class of asymmetric synapses had dense-core vesicles. The area of the active zones was large for the asymmetric synapses (median value 0.20 microns 2), and small for the symmetric ones (median value 0.10 microns 2), and the difference was significant. On average, the areas of the active zones of the synapses on thin dendrites were larger than those of synapses on large calibre dendrites. About every 4 microns 2 of dendritic area received one contact. There was a significant difference between the areas of the active zones of the synapses at the two locations. Moreover, the number per unit dendritic length was correlated with dendrite calibre. On average, the active zones covered more than 4% of the dendritic area; this value for thin dendrites was about twice as large as that of large calibre dendrites. We suggest that the larger active zones and the larger synaptic coverage of the thin dendrites compensate for the longer electrotonic distance of these synapses from the soma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Correction of sagittal and transverse maxillary discrepancies in patients with cleft lip or palate remains a challenge for craniofacial surgeons. Distraction osteogenesis has revolutionized the conceptualization and approach to the craniofacial malformations and has become a reliable and irreplaceable part of the surgical armamentarium. We are reporting a case of sequential maxillary advancement and transpalatal expansion using internal distraction in a patient with unilateral cleft lip and palate presenting with severe maxillary sagittal and transverse deficiencies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to design a wearable system for kinetics measurement of multi-segment foot joints in long-distance walking and to investigate its suitability for clinical evaluations. The wearable system consisted of inertial sensors (3D gyroscopes and 3D accelerometers) on toes, forefoot, hindfoot, and shank, and a plantar pressure insole. After calibration in a laboratory, 10 healthy elderly subjects and 12 patients with ankle osteoarthritis walked 50m twice wearing this system. Using inverse dynamics, 3D forces, moments, and power were calculated in the joint sections among toes, forefoot, hindfoot, and shank. Compared to those we previously estimated for a one-segment foot model, the sagittal and transverse moments and power in the ankle joint, as measured via multi-segment foot model, showed a normalized RMS difference of less than 11%, 14%, and 13%, respectively, for healthy subjects, and 13%, 15%, and 14%, for patients. Similar to our previous study, the coronal moments were not analyzed. Maxima-minima values of anterior-posterior and vertical force, sagittal moment, and power in shank-hindfoot and hindfoot-forefoot joints were significantly different between patients and healthy subjects. Except for power, the inter-subject repeatability of these parameters was CMC>0.90 for healthy subjects and CMC>0.70 for patients. Repeatability of these parameters was lower for the forefoot-toes joint. The proposed measurement system estimated multi-segment foot joints kinetics with acceptable repeatability but showed difference, compared to those previously estimated for the one-segment foot model. These parameters also could distinguish patients from healthy subjects. Thus, this system is suggested for outcome evaluations of foot treatments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The primary somatosensory cortex (SI) contains Brodmann areas (BA) 1, 2, 3a, and 3b. Research in non-human primates showed that BAs 3b, 1, and 2 each contain one full representation of the hand with separate representations for each finger. This research also showed that the finger representation in BA3b has larger and clearer finger somatotopy than BA1 and 2. Although several efforts to map finger somatotopy in SI by fMRI have been made at 1.5 and 3T these studies have yielded variable results and were not able to detect single subject finger somatotopy, probably due to the limited spatial extent of the cortical areas representing a digit (close to the resolution in most fMRI experiments), complications due to acquisition of consistent maps for individual subjects (Schweizer et al 2008), or inter-individual variability in sulcal anatomy impeding group studies. Here, we used 7T fMRI to investigate finger somatotopy in SI, some of its functional characteristics, and its reproducibility. Methods: Eight right-handed male subjects were scanned on a 7T scanner (Siemens Medical, Germany) with an 8-channel Tx/Rx rf-coil (Rapid Biomedical, Germany). 1.3x1.3x1.3mm3 resolution fMRI data were acquired using a sinusoidal readout EPI sequence (Speck et al, 2008) and FOV=210mm, TE/TR=27ms/2.5s, GRAPPA=2. Each volume contained 28 transverse slices covering SI. A single EPI volume with 64 slices was acquired to aid coregistration. 1x1x1mm3 anatomical data were acquire using the MP2RAGE sequence (Marques et al, 2009; TE/TR/TI1,2/TRmprage=2.63ms/7.2ms/0.9,3.2s/5s). Subjects were positioned supine in the scanner with their right arm comfortably against the magnet bore. An experimenter was positioned at the entrance of the bore where he could easily reach and stroke successively the two distal phalanxes of each digit. The order of stroked digit was D1 (thumb)-D3-D5-D2-D4, with 20s ON, 10s OFF alternated. This sequence was repeated four times per run and two functional runs were acquired per subject. Realignment, smoothing (FWHM 2 mm), coregistration of the anatomical to the fMRI data and calculation of t-statistics were done using SPM8. An SI mask was obtained via an F-contrast (p<0.001) over all digits. Within the mask, voxels were labeled with the number of the digit demonstrating the highest t-value for that particular voxel. Results: For all subjects, areas corresponding to the five digits were identified in contralateral SI. BA3b showed the most consistent somatotopic finger representation (see an example in Fig.1). The five digits were localized in a consecutive order in the cortex, with D1 most anterior, inferior and distal and D5, most posterior, superior and medial (mean distance between centres of mass of digit representations ±stderr: 4.2±0.7mm; see Fig. 2). The analysis of average beta values within each finger representation region revealed the specificity of the somatotopic region to the tactile input for each tested finger (except digit 4 and 5). Five of these subjects also presented an orderly and consecutive representation of the five digits in BA1 and 2. Conclusions: Our data reveal that the increased BOLD sensitivity at 7T and the high spatial resolution used in this study allow consistent somatotopic mapping using human touch as a stimulus and that human SI contains at least three separate regions that contain five separate representations of all single contralateral fingers. Moreover, adjacent fingers were represented at adjacent cortical regions across the three SI regions. The spatial organization of SI as reflected in individual subject topography corresponds well with previous electrophysiological data in non-human primates. The small distance between digit representations highlights the need for the high spatial resolution available at 7T.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To assess the value of sampling lymph nodes located far sidelong colorectal cancer specimens, we analyzed retrospectively surgical specimens from 345 colorectal cancer patients. The mesocolic and perirectal fat was divided into 2 fractions: close to (<5 cm) and distant from (>5 cm) the tumor. Tumors were located in the cecum (n = 61), ascending colon (n = 29), transverse colon (n = 31), descending colon (n = 27), sigmoid colon (n = 108), and rectum (n = 89). The median number of lymph nodes sampled was 17 in both fractions (range, 4-66), 12 (range, 0-46) in the close fraction, and 3 (range, 0-33) in the distant fraction. There were 169 pN0, 104 pN1, and 72 pN2 cases. The pN staging was accurate in all cases except 10 based on the close fraction alone; of these, 6 were upstaged from pN0 to pN1 and 4 from pN1 to pN2 when the distant fraction was considered. Among pN1-upstaged cases, 5 were rectal (3/5 with neoadjuvant radiotherapy) and 1 colonic. In the colon, we found that lymph node location is more important than lymph node number because metastatic lymph nodes were present mostly in the peritumoral area. This suggests that lymph nodes should be initially recovered from the pericolic fat close to the tumor. If there are less than 4 positive lymph nodes and less than 12 lymph nodes examined in total, additional lymph nodes should be retrieved from the distal fraction for potential upstaging. In the rectum, systematic sampling of close and distant lymph nodes is mandatory because in rare cases, metastases are detected only in distant lymph nodes, particularly in patients who have undergone neoadjuvant radiotherapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Traumatic hernia of the abdominal wall is a rare and easily missed injury in the presence of major pelvic and abdominal lesions. We present a radiographically documented case of combined pelvic and acetabular fracture with a major contralateral traumatic hernia with avulsion of the internal oblique, the external oblique and the transverse abdominal muscles diagnosed four months after the initial trauma. To our knowledge no similar case has been described in the current literature.