992 resultados para size accuracy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hemolytic profile of an artificial device chronically implanted in the cardiovascular system may represent the difference between the success and failure in its long-term performance. Last decades have witnessed efforts on the development of methods capable of predicting red blood cell damage in artificial organs. However, all of them have had limited success to predict hemolysis. The primary cause of this problem is that such models do not take into consideration structures of turbulent flow. The present paper demonstrates that microscopic measurable occurrences of the turbulent flow may be linked to red blood cell trauma. This study suggests that if the smallest turbulent eddies dimension is under 10 m m hemolysis is not dependent on the exposure time and the red blood cells damage depends only on the dissipation of the turbulent energy in the erythrocyte membrane. The analysis reported here opens the possibility of mapping the flow field in artificial assist devices based on the smallest eddy length scales. This is a promising new trend and should be considered in the designing requirements of the next generations of artificial organs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Venturi scrubbers are high efficiency gas cleaners in which suspended particles are removed from gas streams by droplets formed by liquid atomisation, usually in the venturi throat. The size of the droplets formed is of fundamental importance to the performance of the equipment, both in terms of pressure drop and collection efficiency. In this study, drop sizes in a cylindrical laboratory scale venturi scrubber were measured using a laser diffraction technique. Gas velocity and liquid to gas ratios varied from 50 to 90 m/s and 0.5 to 2.0 l/m3, respectively. Water was inserted as perpendicular jets at the beginning of the throat. Measurements were performed at three positions: two located along the throat, and the last one at the end of the diffuser. The data presented here are a typical example of pneumatic atomisation and can be relevant to other industrial applications such as combustion and engine technology. Finally, results are compared to available correlations and the validity of these equations is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The knowledge of the slug flow characteristics is very important when designing pipelines and process equipment. When the intermittences typical in slug flow occurs, the fluctuations of the flow variables bring additional concern to the designer. Focusing on this subject the present work discloses the experimental data on slug flow characteristics occurring in a large-size, large-scale facility. The results were compared with data provided by mechanistic slug flow models in order to verify their reliability when modelling actual flow conditions. Experiments were done with natural gas and oil or water as the liquid phase. To compute the frequency and velocity of the slug cell and to calculate the length of the elongated bubble and liquid slug one used two pressure transducers measuring the pressure drop across the pipe diameter at different axial locations. A third pressure transducer measured the pressure drop between two axial location 200 m apart. The experimental data were compared with results of Camargo's1 algorithm (1991, 1993), which uses the basics of Dukler & Hubbard's (1975) slug flow model, and those calculated by the transient two-phase flow simulator OLGA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Production machines for next generation LSIs such as 4G-DRAMs and for large liquid crystal displays such as 0.5mx0.5m size, and information equipment such as magnetic hard disks and DVDs must have the positioning accuracy of a nano-meter order. To realize such a high degree of the positioning accuracy, not only precision machine elements and mechanisms but also high precision sensors, actuators and controller design techniques becomes crucial. This paper introduces recent topics of precision positioning and motion control technology in Japan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Longitudinal surveys are increasingly used to collect event history data on person-specific processes such as transitions between labour market states. Surveybased event history data pose a number of challenges for statistical analysis. These challenges include survey errors due to sampling, non-response, attrition and measurement. This study deals with non-response, attrition and measurement errors in event history data and the bias caused by them in event history analysis. The study also discusses some choices faced by a researcher using longitudinal survey data for event history analysis and demonstrates their effects. These choices include, whether a design-based or a model-based approach is taken, which subset of data to use and, if a design-based approach is taken, which weights to use. The study takes advantage of the possibility to use combined longitudinal survey register data. The Finnish subset of European Community Household Panel (FI ECHP) survey for waves 1–5 were linked at person-level with longitudinal register data. Unemployment spells were used as study variables of interest. Lastly, a simulation study was conducted in order to assess the statistical properties of the Inverse Probability of Censoring Weighting (IPCW) method in a survey data context. The study shows how combined longitudinal survey register data can be used to analyse and compare the non-response and attrition processes, test the missingness mechanism type and estimate the size of bias due to non-response and attrition. In our empirical analysis, initial non-response turned out to be a more important source of bias than attrition. Reported unemployment spells were subject to seam effects, omissions, and, to a lesser extent, overreporting. The use of proxy interviews tended to cause spell omissions. An often-ignored phenomenon classification error in reported spell outcomes, was also found in the data. Neither the Missing At Random (MAR) assumption about non-response and attrition mechanisms, nor the classical assumptions about measurement errors, turned out to be valid. Both measurement errors in spell durations and spell outcomes were found to cause bias in estimates from event history models. Low measurement accuracy affected the estimates of baseline hazard most. The design-based estimates based on data from respondents to all waves of interest and weighted by the last wave weights displayed the largest bias. Using all the available data, including the spells by attriters until the time of attrition, helped to reduce attrition bias. Lastly, the simulation study showed that the IPCW correction to design weights reduces bias due to dependent censoring in design-based Kaplan-Meier and Cox proportional hazard model estimators. The study discusses implications of the results for survey organisations collecting event history data, researchers using surveys for event history analysis, and researchers who develop methods to correct for non-sampling biases in event history data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The report describes those factors of the future that are related to the growth and needs of Russia, China, and India and that may provide significant internationalisation potential for Uusimaa companies. The report examines the emerging trends and market-entry challenges for each country separately. Additionally, it evaluates the training needs of Uusimaa companies in terms of the current offerings available for education on topics related to Russia, China, and India. The report was created via the Delphi method: experts were interviewed, and both Trendwiki material and the latest literature were used to create a summary of experts’ views, statements, and reasons behind recent developments. This summary of views was sent back to the experts with the objective of reaching consensus synthesising the differing views or, at least, of providing argumentation for the various alternative lines of development. In addition to a number of outside experts and business leaders, all heads of Finpro’s Finland Trade Centers participated in the initial interviews. The summary was commented upon by all Finpro consultants and analysts for Russia, China, and India, with each focusing on his or her own area of expertise. The literature used consisted of reports, listed for each country, and an extensive selection of the most recent newspaper articles. The report was created in January-April 2010. On 22 April 2010 its results were reviewed at the final report presentation in cooperation with the Uusimaa ELY Centre.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An understanding of seed germination ecology of weeds can assist in predicting their potential distribution and developing effective management strategies. Influence of environmental factors and seed size on germination and seedling emergence of Convolvulus arvensis (field bindweed) was studied in laboratory and greenhouse conditions. Germination occurred over a wide range of constant temperatures, between 15 and 40 ºC, with optimum germination between 20 and 25 ºC. Time to start germination, time to 50% germination and mean germination time increased while germination percentage and germination index decreased with an increase in temperature from 20 ºC, salinity and osmotic stress. However, germination was tolerant to low salt (25 mM) or osmotic stress (0.2 MPa), but as salinity and osmotic stress increased, germination percentage and germination index decreased. Seeds of C. arvensis placed at soil surface showed maximum emergence and decreased as seeding depth increased. Seeds of C. arvensis germinated over a wide range of pH (4 to 9) but optimum germination occurred at pH 6 to 8. Under highly alkaline and acidic pH, time to start germination, time to 50% germination and mean germination time increased while germination percentage and germination index decreased. Increase in field capacity caused decreased time to start germination, time to 50% germination and mean germination time but increased germination percentage and germination index. Bigger seeds had low time to start germination, time to 50% germination and mean germination time but high germination percentage and germination index. Smaller seeds were more sensitive to environmental factors as compared to larger or medium seeds. It can be concluded that except for pH, all environmental factors and seed sizes adversely affect C. arvensis as regards seed germination or emergence and germination or emergence traits, and larger seeds result in improved stand establishment and faster germination than small seeds, regardless of moisture stress or deeper seeding depth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis presents a framework for segmentation of clustered overlapping convex objects. The proposed approach is based on a three-step framework in which the tasks of seed point extraction, contour evidence extraction, and contour estimation are addressed. The state-of-art techniques for each step were studied and evaluated using synthetic and real microscopic image data. According to obtained evaluation results, a method combining the best performers in each step was presented. In the proposed method, Fast Radial Symmetry transform, edge-to-marker association algorithm and ellipse fitting are employed for seed point extraction, contour evidence extraction and contour estimation respectively. Using synthetic and real image data, the proposed method was evaluated and compared with two competing methods and the results showed a promising improvement over the competing methods, with high segmentation and size distribution estimation accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Variations in egg length were observed for two populations of cryptic species of Anastrepha fraterculus (Wiedemann). The eggs of type I flies were smaller than those of type II individuals. For both types, in regard to yolk mass extrusion, four classes of embryos were detected. Class 1: embryos that extrude masses at both extremities; class 2: embryos in which extrusion occurs only at the anterior pole; class 3: embryos that eliminate mass only at the posterior pole, and class 4: embryos that do not extrude any mass. Embryo class frequencies were similar for populations belonging to the same type, but different between types. Individual females may produce eggs from different embryo classes, but for any given female the pattern remains constant during a long period of oviposition. Variation in size of the extruded masses was similar for both populations. Individual females produced embryos with a small range of mass diameters, and different females produced masses of different mean size. However, individual mass size remained constant during oviposition. The results suggest the existence of genetic components involved in the control of this unusual process. Larvae of both types presented, just before eclosion, similar unusual behaviors: they ingest the anterior extruded mass, rotate 180°, absorb the posterior mass and eclose near the posterior pole. Data show that cryptic A. fraterculus type I and type II differs in regard to egg size as well as to the phenomenon of yolk mass extrusion

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to validate the transit-time technique for long-term measurements of iliac and renal blood flow in rats. Flow measured with ultrasonic probes was confirmed ex vivo using excised arteries perfused at varying flow rates. An implanted 1-mm probe reproduced with accuracy different patterns of flow relative to pressure in freely moving rats and accurately quantitated the resting iliac flow value (on average 10.43 ± 0.99 ml/min or 2.78 ± 0.3 ml min-1 100 g body weight-1). The measurements were stable over an experimental period of one week but were affected by probe size (resting flows were underestimated by 57% with a 2-mm probe when compared with a 1-mm probe) and by anesthesia (in the same rats, iliac flow was reduced by 50-60% when compared to the conscious state). Instantaneous changes of iliac and renal flow during exercise and recovery were accurately measured by the transit-time technique. Iliac flow increased instantaneously at the beginning of mild exercise (from 12.03 ± 1.06 to 25.55 ± 3.89 ml/min at 15 s) and showed a smaller increase when exercise intensity increased further, reaching a plateau of 38.43 ± 1.92 ml/min at the 4th min of moderate exercise intensity. In contrast, exercise-induced reduction of renal flow was smaller and slower, with 18% and 25% decreases at mild and moderate exercise intensities. Our data indicate that transit-time flowmetry is a reliable method for long-term and continuous measurements of regional blood flow at rest and can be used to quantitate the dynamic flow changes that characterize exercise and recovery

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For certain applications of the polymerase chain reaction (PCR), it may be necessary to consider the accuracy of replication. The breakthrough that made PCR user friendly was the commercialization of Thermus aquaticus (Taq) DNA polymerase, an enzyme that would survive the high temperatures needed for DNA denaturation. The development of enzymes with an inherent 3' to 5' exonuclease proofreading activity, lacking in Taq polymerase, would be an improvement when higher fidelity is needed. We used the forward mutation assay to compare the fidelity of Taq polymerase and Thermotoga maritima (ULTMA™) DNA polymerase, an enzyme that does have proofreading activity. We did not find significant differences in the fidelity of either enzyme, even when using optimal buffer conditions, thermal cycling parameters, and number of cycles (0.2% and 0.13% error rates for ULTMA™ and Taq, respectively, after reading about 3,000 bases each). We conclude that for sequencing purposes there is no difference in using a DNA polymerase that contains an inherent 3' to 5' exonuclease activity for DNA amplification. Perhaps the specificity and fidelity of PCR are complex issues influenced by the nature of the target sequence, as well as by each PCR component.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although gap junction channels are still widely viewed as large, non-specific pores connecting cells, the diversity in the connexin family has led more attention to be focused on their permeability characteristics. We summarize here the current status of these investigations, both published and on-going, that reveal both charge and size selectivity between gap junction channels composed of different connexins. In particular, this review will focus on quantitative approaches that monitor the expression level of the connexins, so that it is clear that differences that are seen can be attributed to channel properties. The degree of selectivity that is observed is modest compared to other channels, but is likely to be significant for biological molecules that are labile within the cell. Of particular relevance to the in vivo function of gap junctions, recent studies are summarized that demonstrate that the connexin phenotype can control the nature of the endogenous traffic between cells, with consequent effects on biological effects of gap junctions such as tumor suppression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of limiting dilution assay (LDA) for assessing the frequency of responders in a cell population is a method extensively used by immunologists. A series of studies addressing the statistical method of choice in an LDA have been published. However, none of these studies has addressed the point of how many wells should be employed in a given assay. The objective of this study was to demonstrate how a researcher can predict the number of wells that should be employed in order to obtain results with a given accuracy, and, therefore, to help in choosing a better experimental design to fulfill one's expectations. We present the rationale underlying the expected relative error computation based on simple binomial distributions. A series of simulated in machina experiments were performed to test the validity of the a priori computation of expected errors, thus confirming the predictions. The step-by-step procedure of the relative error estimation is given. We also discuss the constraints under which an LDA must be performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this research is to estimate and characterize heterogeneous mass transfer coefficients in bench- and pilot-scale fluidized bed processes by the means of computational fluid dynamics (CFD). A further objective is to benchmark the heterogeneous mass transfer coefficients predicted by fine-grid Eulerian CFD simulations against empirical data presented in the scientific literature. First, a fine-grid two-dimensional Eulerian CFD model with a solid and gas phase has been designed. The model is applied for transient two-dimensional simulations of char combustion in small-scale bubbling and turbulent fluidized beds. The same approach is used to simulate a novel fluidized bed energy conversion process developed for the carbon capture, chemical looping combustion operated with a gaseous fuel. In order to analyze the results of the CFD simulations, two one-dimensional fluidized bed models have been formulated. The single-phase and bubble-emulsion models were applied to derive the average gas-bed and interphase mass transfer coefficients, respectively. In the analysis, the effects of various fluidized bed operation parameters, such as fluidization, velocity, particle and bubble diameter, reactor size, and chemical kinetics, on the heterogeneous mass transfer coefficients in the lower fluidized bed are evaluated extensively. The analysis shows that the fine-grid Eulerian CFD model can predict the heterogeneous mass transfer coefficients quantitatively with acceptable accuracy. Qualitatively, the CFD-based research of fluidized bed process revealed several new scientific results, such as parametrical relationships. The huge variance of seven orders of magnitude within the bed Sherwood numbers presented in the literature could be explained by the change of controlling mechanisms in the overall heterogeneous mass transfer process with the varied process conditions. The research opens new process-specific insights into the reactive fluidized bed processes, such as a strong mass transfer control over heterogeneous reaction rate, a dominance of interphase mass transfer in the fine-particle fluidized beds and a strong chemical kinetic dependence of the average gas-bed mass transfer. The obtained mass transfer coefficients can be applied in fluidized bed models used for various engineering design, reactor scale-up and process research tasks, and they consequently provide an enhanced prediction accuracy of the performance of fluidized bed processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to the equivalent light hypothesis, molecular defects in the photoreceptor lead to a continuous activation of the photoreceptor cascade in a manner equivalent to real light. The consequences in diseases such as retinitis pigmentosa (RP) are as disruptive to the cells as real light. Two forms of the equivalent light hypothesis can be distinguished: strong - mutations in rhodopsin or other cascade proteins in some forms of RP continuously excite the visual phototransduction cascade; weak - disruption of outer segments in all patients with RP eliminates circulating dark current and blocks neurotransmitter release in a manner similar to real light. Both forms of the equivalent light hypothesis predict that pupils of patients with RP will be constricted like those of normal subjects in the light. The purpose of this study was to test the equivalent light hypothesis by determining whether steady-state pupil diameter following full dark adaptation is abnormally small in any of a sample of patients with RP. Thirty-five patients with RP and 15 normal subjects were tested. Direct steady-state pupillometric measures were obtained from one eye in a full-field dome after 45 min of dark adaptation by videotaping the pupil with an infrared camera. Mean pupil diameter in the dark was comparable (t = -0.15, P = 0.88) between patients with RP (6.85 ± 0.58 mm) and normal subjects (6.82 ± 0.76 mm). The results of the present study are clearly counter to the prediction of the second (weaker) form of the equivalent light hypothesis.