969 resultados para signal quality
Resumo:
Introduction: Ultrasmall superparamagnetic iron oxide (USPIO)-enhanced MRI has been shown to be a useful modality to image activated macrophages in vivo, which are principally responsible for plaque inflammation. This study determined the optimum imaging time-window to detect maximal signal change post-USPIO infusion using T1-weighted (T1w), T2*- weighted (T2*w) and quantitative T2*(qT 2*) imaging. Methods: Six patients with an asymptomatic carotid stenosis underwent high resolution T1w, T2*w and qT2*MR imaging of their carotid arteries at 1.5 T. Imaging was performed before and at 24, 36, 48, 72 and 96 h after USPIO (Sinerem™, Guerbet, France) infusion. Each slice showing atherosclerotic plaque was manually segmented into quadrants and signal changes in each quadrant were fitted to an exponential power function to model the optimum time for post-infusion imaging. Results: The power function determining the mean time to convergence for all patients was 46, 41 and 39 h for the T1w, T 2*w and qT2*sequences, respectively. When modelling each patient individually, 90% of the maximum signal intensity change was observed at 36 h for three, four and six patients on T1w, T 2*w and qT2*, respectively. The rates of signal change decrease after this period but signal change was still evident up to 96 h. Conclusion: This study showed that a suitable imaging window for T 1w, T2*w and qT2*signal changes post-USPIO infusion was between 36 and 48 h. Logistically, this would be convenient in bringing patients back for one post-contrast MRI, but validation is required in a larger cohort of patients.
Resumo:
A high speed digital signal averager with programmable features for the sampling period, for the number of channels and for the number of sweeps is described. The system implements a stable averaging algorithm (Deadroff and Trimble 1968) to provide a stable, calibrated display. The performance of the instrument has been evaluated for the reduction of random noise and for comb-filter action. Special uses of the instrument as a box-car integrator and as a transient recorder are also indicated.
Resumo:
The quality of ultrasound computed tomography imaging is primarily determined by the accuracy of ultrasound transit time measurement. A major problem in analysis is the overlap of signals making it difficult to detect the correct transit time. The current standard is to apply a matched-filtering approach to the input and output signals. This study compares the matched-filtering technique with active set deconvolution to derive a transit time spectrum from a coded excitation chirp signal and the measured output signal. The ultrasound wave travels in a direct and a reflected path to the receiver, resulting in an overlap in the recorded output signal. The matched-filtering and deconvolution techniques were applied to determine the transit times associated with the two signal paths. Both techniques were able to detect the two different transit times; while matched-filtering has a better accuracy (0.13 μs vs. 0.18 μs standard deviation), deconvolution has a 3.5 times improved side-lobe to main-lobe ratio. A higher side-lobe suppression is important to further improve image fidelity. These results suggest that a future combination of both techniques would provide improved signal detection and hence improved image fidelity.
Resumo:
With growing population and fast urbanization in Australia, it is a challenging task to maintain our water quality. It is essential to develop an appropriate statistical methodology in analyzing water quality data in order to draw valid conclusions and hence provide useful advices in water management. This paper is to develop robust rank-based procedures for analyzing nonnormally distributed data collected over time at different sites. To take account of temporal correlations of the observations within sites, we consider the optimally combined estimating functions proposed by Wang and Zhu (Biometrika, 93:459-464, 2006) which leads to more efficient parameter estimation. Furthermore, we apply the induced smoothing method to reduce the computational burden. Smoothing leads to easy calculation of the parameter estimates and their variance-covariance matrix. Analysis of water quality data from Total Iron and Total Cyanophytes shows the differences between the traditional generalized linear mixed models and rank regression models. Our analysis also demonstrates the advantages of the rank regression models for analyzing nonnormal data.
Resumo:
Environmental data usually include measurements, such as water quality data, which fall below detection limits, because of limitations of the instruments or of certain analytical methods used. The fact that some responses are not detected needs to be properly taken into account in statistical analysis of such data. However, it is well-known that it is challenging to analyze a data set with detection limits, and we often have to rely on the traditional parametric methods or simple imputation methods. Distributional assumptions can lead to biased inference and justification of distributions is often not possible when the data are correlated and there is a large proportion of data below detection limits. The extent of bias is usually unknown. To draw valid conclusions and hence provide useful advice for environmental management authorities, it is essential to develop and apply an appropriate statistical methodology. This paper proposes rank-based procedures for analyzing non-normally distributed data collected at different sites over a period of time in the presence of multiple detection limits. To take account of temporal correlations within each site, we propose an optimal linear combination of estimating functions and apply the induced smoothing method to reduce the computational burden. Finally, we apply the proposed method to the water quality data collected at Susquehanna River Basin in United States of America, which dearly demonstrates the advantages of the rank regression models.
Resumo:
Modern drug discovery gives rise to a great number of potential new therapeutic agents, but in some cases the efficient treatment of patient may not be achieved because the delivery of active compounds to the target site is insufficient. Thus, drug delivery is one of the major challenges in current pharmaceutical research. Numerous nanoparticle-based drug carriers, e.g. liposomes, have been developed for enhanced drug delivery and targeting. Drug targeting may enhance the efficiency of the treatment and, importantly, reduce unwanted side effects by decreasing drug distribution to non-target tissues. Liposomes are biocompatible lipid-based carriers that have been studied for drug delivery during the last 40 years. They can be functionalized with targeting ligands and sensing materials for triggered activation. In this study, various external signal-assisted liposomal delivery systems were developed. Signals can be used to modulate drug permeation or release from the liposome formulation, and they provide accurate control of time, place and rate of activation. The study involved three types of signals that were used to trigger drug permeation and release: electricity, heat and light. Electrical stimulus was utilized to enhance the permeation of liposomal DNA across the skin. Liposome/DNA complex-mediated transfections were performed in tight rat epidermal cell model. Various transfection media and current intensities were tested, and transfection efficiency was evaluated non-invasively by monitoring the concentration of secreted reporter protein in cell culture medium. Liposome/DNA complexes produced gene expression, but electrical stimulus did not enhance the transfection efficiency significantly. Heat-sensitive liposomal drug delivery system was developed by coating liposomes with biodegradable and thermosensitive poly(N-(2-hydroxypropyl) methacrylamide-mono/dilactate polymer. Temperature-triggered liposome aggregation and contents release from liposomes were evaluated. The cloud point temperature (CP) of the polymer was set to 42 °C. Polymer-coated liposome aggregation and contents release were observed above CP of the polymer, while non-coated liposomes remained intact. Polymer precipitates above its CP and interacts with liposomal bilayers. It is likely that this induces permeabilization of the liposomal membrane and contents release. Light-sensitivity was introduced to liposomes by incorporation of small (< 5 nm) gold nanoparticles. Hydrophobic and hydrophilic gold nanoparticles were embedded in thermosensitive liposomes, and contents release was investigated upon UV light exposure. UV light-induced lipid phase transitions were examined with small angle X-ray scattering, and light-triggered contents release was shown also in human retinal pigment epithelial cell line. Gold nanoparticles absorb light energy and transfer it into heat, which induces phase transitions in liposomes and triggers the contents release. In conclusion, external signal-activated liposomes offer an advanced platform for numerous applications in drug delivery, particularly in the localized drug delivery. Drug release may be localized to the target site with triggering stimulus that results in better therapeutic response and less adverse effects. Triggering signal and mechanism of activation can be selected according to a specific application.
Resumo:
The aims of this study were to investigate outcome and to evaluate areas of potential ongoing concern after orthotopic liver transplantation (OLT) in children. Actuarial survival in relation to age and degree of undernutrition at the time of OLT was evaluated in 53 children (age 0.58-14.2 years) undergoing OLT for endstage liver disease. Follow-up studies of growth and quality of life were undertaken in those with a minimum follow-up period of 12 months (n = 26). The overall 3 year actuarial survival was 70%. Survival rates did not differ between age groups (actuarial 2 year survival for ages <1, 1-5 and >5 years were 70, 70 and 69% respectively) but did differ according to nutritional status at OLT (actuarial 2 year survival for children with Z scores for weight <-1 was 57%, >-1 was 95%; P = 0.004). Significant catch-up weight gain was observed by 18 months post-transplant, while height improved less rapidly. Quality of life (assessed by Vineland Adaptive Behaviour Scales incorporating socialization, daily living skills, communication and motor skills) was good (mean composite score 91 ± 19). All school-aged children except one were attending normal school. Two children had mild to moderate intellectual handicap related to post-operative intracerebral complications. Satisfactory long-term survival can be achieved after OLT in children regardless of age but the importance of pre-operative nutrition is emphasized. Survivors have an excellent chance of a good quality of life and of satisfactory catch-up weight gain and growth.
Resumo:
Sharks caught in tropical Australian waters occasionally exhibit tough texture. Two species of Carcharinid shark, originally known as the sorrah shark (Carcharinus sorrah) and the black spot shark (Carcharinus tilstoni), compose the majority of the catch. Experiments were conducted to identify the cause of tough texture and to improve the overall quality of the catch. The possibility that a cold shock reaction may occur was investigated by observing the contraction of fillets under a range of temperature conditions before freezing. The effect of on-board handling practices were evaluated using frozen shark fillets, which had been stored prior to freezing in refrigerated seawater at different rigor stages, temperatures and times as trunks. Fillets were analyzed for nucleotides, lactate, thaw pH, sarcomere length and raw and cooked shear force values. The existence of thaw rigor was also investigated. There was little difference in the texture between the individual strips of a fillet exposed to different temperatures but there were significant differences between individual sharks. A cold shock reaction could not be demonstrated in these species. The main influences on texture were of biological origin. The species, sex and size were found to have significant links with texture of fillets. The quality of the fillets deteriorated quicker during the warmer season and were at their worst if the trunks were kept on deck till post-rigor or held in 15 degree C refrigerated seawater before freezing
Resumo:
Diced cantaloupe flesh that was microbiologically sterile was prepared in order to study the physiological deterioration of fruit when stored under a range of controlled atmospheres at 4.5°C. Sterile fruit pieces were prepared by boiling whole melons for 3 min, then dicing aseptically. Storage atmospheres were in continuous flow and contained from 0 to 26% CO2 and 3.5 to 17% O2. Sensory assessments were carried out by a highly trained panel at 14-day intervals. Products that were acceptable for up to 28 days were obtained when the following 3 treatments were used: 6% CO2 and 6% O2; 9.5% CO2 and 3.5% O2; and 15% CO2 and 6% O2. Overall, treatment with 0, 19.5 or 26% CO2 (irrespective of O2 concn.) caused significant deterioration in sensory properties.
Resumo:
The potential of near infra-red (NIR) spectroscopy for non-invasive measurement of fruit quality of pineapple (Ananas comosus var. Smooth Cayenne) and mango (Magnifera indica var. Kensington) fruit was assessed. A remote reflectance fibre optic probe, placed in contact with the fruit skin surface in a light-proof box, was used to deliver monochromatic light to the fruit, and to collect NIR reflectance spectra (760–2500 nm). The probe illuminated and collected reflected radiation from an area of about 16 cm2. The NIR spectral attributes were correlated with pineapple juice Brix and with mango flesh dry matter (DM) measured from fruit flesh directly underlying the scanned area. The highest correlations for both fruit were found using the second derivative of the spectra (d2 log 1/R) and an additive calibration equation. Multiple linear regression (MLR) on pineapple fruit spectra (n = 85) gave a calibration equation using d2 log 1/R at wavelengths of 866, 760, 1232 and 832 nm with a multiple coefficient of determination (R2) of 0.75, and a standard error of calibration (SEC) of 1.21 °Brix. Modified partial least squares (MPLS) regression analysis yielded a calibration equation with R2 = 0.91, SEC = 0.69, and a standard error of cross validation (SECV) of 1.09 oBrix. For mango, MLR gave a calibration equation using d2 log 1/R at 904, 872, 1660 and 1516 nm with R2 = 0.90, and SEC = 0.85% DM and a bias of 0.39. Using MPLS analysis, a calibration equation with R2 = 0.98, SEC = 0.54 and SECV = 1.19 was obtained. We conclude that NIR technology offers the potential to assess fruit sweetness in intact whole pineapple and DM in mango fruit, respectively, to within 1° Brix and 1% DM, and could be used for the grading of fruit in fruit packing sheds.
Resumo:
Ethylene production is stimulated during the slicing of fresh cut tomato slices. Experiments were conducted to investigate whether the inclusion of ethylene absorbents in packaging affects the quality of tomato slices cv. Revolution during storage at 5OC. ‘Pink’ maturity stage tomatoes were cut into 7mm thick slices and vertically stacked in closed glass containers for 12 days with or without Purafil® to remove ethylene. The ethylene removal treatment resulted in reduced ethylene, less CO2 accumulation, and firmer slices.
Resumo:
A modified least mean fourth (LMF) adaptive algorithm applicable to non-stationary signals is presented. The performance of the proposed algorithm is studied by simulation for non-stationarities in bandwidth, centre frequency and gain of a stochastic signal. These non-stationarities are in the form of linear, sinusoidal and jump variations of the parameters. The proposed LMF adaptation is found to have better parameter tracking capability than the LMS adaptation for the same speed of convergence.
Resumo:
At present, the most reliable method to obtain end-user perceived quality is through subjective tests. In this paper, the impact of automatic region-of-interest (ROI) coding on perceived quality of mobile video is investigated. The evidence, which is based on perceptual comparison analysis, shows that the coding strategy improves perceptual quality. This is particularly true in low bit rate situations. The ROI detection method used in this paper is based on two approaches: - (1) automatic ROI by analyzing the visual contents automatically, and; - (2) eye-tracking based ROI by aggregating eye-tracking data across many users, used to both evaluate the accuracy of automatic ROI detection and the subjective quality of automatic ROI encoded video. The perceptual comparison analysis is based on subjective assessments with 54 participants, across different content types, screen resolutions, and target bit rates while comparing the two ROI detection methods. The results from the user study demonstrate that ROI-based video encoding has higher perceived quality compared to normal video encoded at a similar bit rate, particularly in the lower bit rate range.
Resumo:
Spectral data were collected of intact and ground kernels using 3 instruments (using Si-PbS, Si, and InGaAs detectors), operating over different areas of the spectrum (between 400 and 2500 nm) and employing transmittance, interactance, and reflectance sample presentation strategies. Kernels were assessed on the basis of oil and water content, and with respect to the defect categories of insect damage, rancidity, discoloration, mould growth, germination, and decomposition. Predictive model performance statistics for oil content models were acceptable on all instruments (R2 > 0.98; RMSECV < 2.5%, which is similar to reference analysis error), although that for the instrument employing reflectance optics was inferior to models developed for the instruments employing transmission optics. The spectral positions for calibration coefficients were consistent with absorbance due to the third overtones of CH2 stretching. Calibration models for moisture content in ground samples were acceptable on all instruments (R2 > 0.97; RMSECV < 0.2%), whereas calibration models for intact kernels were relatively poor. Calibration coefficients were more highly weighted around 1360, 740 and 840 nm, consistent with absorbance due to overtones of O-H stretching and combination. Intact kernels with brown centres or rancidity could be discriminated from each other and from sound kernels using principal component analysis. Part kernels affected by insect damage, discoloration, mould growth, germination, and decomposition could be discriminated from sound kernels. However, discrimination among these defect categories was not distinct and could not be validated on an independent set. It is concluded that there is good potential for a low cost Si photodiode array instrument to be employed to identify some quality defects of intact macadamia kernels and to quantify oil and moisture content of kernels in the process laboratory and for oil content in-line. Further work is required to examine the robustness of predictive models across different populations, including growing districts, cultivars and times of harvest.