991 resultados para sequential extraction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The capillary micro reactor, with four stable operating flow patterns and a throughput range from grams per hour to kilograms per hour, presents an attractive alternative to chip-based and microstructured reactors for laboratory- and pilot-scale applications. In this article, results for the extraction of 2-butanol from toluene under different flow patterns in a water/toluene flow in long capillary microreactors are presented. The effects of the capillary length (0.4-2.2 m), flow rate (0.1-12 mL/min), and aqueous-to-organic volumetric flow ratio (0.25-9) on the slug, bubbly, parallel, and annular flow hydrodynamics were investigated. Weber-number-dependent flow maps were composed for capillary lengths of 0.4 and 2 m that were used to interpret the flow pattern formation in terms of surface tension and inertia forces. When the capillary length was decreased from 2 to 0.4 m, a transition from annular to parallel flow was observed. The capillary length had little influence on slug and bubbly flows. The flow patterns were evaluated in terms of stability, surface-to-volume ratio, throughput, and extraction efficiency. Slug and bubbly flow operations yielded 100% thermodynamic extraction efficiency, and increasing the aqueous-to-organic volumetric ratio to 9 allowed for 99% 2-butanol extraction. The parallel and annular flow operating windows were limited by the capillary length, thus yielding maximum 2-butanol extractions of 30% and 47% for parallel and annular flows, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A surface plasmon resonance (SPR) biosensor screening assay was developed and validated to detect 11 benzimidazole carbamate (BZT) veterinary drug residues in milk. The polyclonal antibody used was raised in sheep against a methyl 5(6)-[(carboxypentyl)-thio]-2-benzimidazole carbamate protein conjugate. A sample preparation procedure was developed using a modified QuEChERS method. BZT residues were extracted from milk using liquid extraction/partition with a dispersive solid phase extraction clean-up step. The assay was validated in accordance with the performance criteria described in 2002/657/EC. The limit of detection of the assay was calculated from the analysis of 20 known negative milk samples to be 2.7 mu g kg(-1). The detection capability (CC beta) of the assay was determined to be 5 mu g kg(-1) for 11 benzimidazole residues and the mean recovery of analytes was in the range 81-116%. A comparison was made between the SPR-biosensor and UPLC-MS/MS analyses of milk samples (n = 26) taken from cows treated different benzimidazole products, demonstrating the SPR-biosensor assay to be fit for purpose. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-performance liquid chromatography (HPLC) methodologies were evaluated for the detection and quantification of thyreostatic drug residues in cattle serum and thyroid tissue. The paper details a protocol, using a simple ethyl acetate extraction for the determination of thiouracil, tapazole, methyl thiouracil, propyl thiouracil and phenyl thiouracil in thyroid tissue. Using two sequential HPLC injections, and quantitative analysis, in two steps, all five thyreostats were detectable at concentrations greater than 2.45-4.52 ng/g. Modifications to a published method for detection of thyreostatic residues in serum involving the addition of mercaptoethanol and a freezing step are described. The modifications improved sensitivity and allowed detection of the five thyreostats at levels greater than 16.98-35.25 ng/ml. Young bulls were treated with thyreostats to demonstrate the validity of the methodologies described. Administered thyreostats were not absorbed equally by the test animals and the compounds were not all detected in the serum samples removed at 7 days following drug withdrawal. These experiments indicate the necessity to be able to detect thyreostat residues in a variety of matrices. (C) 1998 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A liquid chromatography-thermospray mass spectrometric assay was developed and validated to confirm the presence of illegal residues of the synthetic androgenic growth promoter, trenbolone acetate, in cattle. The assay was specific for 17alpha-trenbolone, the major bovine metabolite of trenbolone acetate. Methods were developed for the determination of 17alpha-trenbolone in both bile and faeces, the most appropriate matrices for the control of trenbolone acetate abuse. The clean-up.procedure developed relied on enzymatic hydrolysis, followed by sequential liquid-liquid and liquid-solid extraction. The extracts were then subjected to immunoaffinity chromatography. 17alpha-Trenbolone was detected by selected ion monitoring at m/z 271 using positive ion thermospray ionisation. The limit of detection was approximately 0.5 ng/g in faeces and 0.5 ng/ml in bile.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel stir bar sorptive extraction (SBSE) method coupled with high performance liquid chromatography (HPLC) and UV detection for the extraction of diclofenac (DIC) from paediatric urine samples has been developed and validated. Selectivity and sensitivity being the prime objectives of the bioanalytical method for clinical samples, an optimised SBSE protocol was developed that selectively extracted DIC from various concurrently administered drugs. The validated assay was found to be linear (r=0.9999) over a concentration range of 100-2000 ng mL(-1). SBSE showed consistent recoveries (similar to 70%) of DIC across the validated linearity range. Overall, the method exhibited excellent accuracy and precision across all QC concentrations, tested over three days. Calculated LOD and LOQ were found to be 12.03 ng mL(-1) and 36.37 ng mL(-1), respectively, however, for the experimental purposes, 100 ngmL(-1) was considered as the validated LOQ(accuracy and precision at this LQC was

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ecological coherence is a multifaceted conservation objective that includes some potentially conflicting concepts. These concepts include the extent to which the network maximises diversity (including genetic diversity) and the extent to which protected areas interact with non-reserve locations. To examine the consequences of different selection criteria, the preferred location to complement protected sites was examined using samples taken from four locations around each of two marine protected areas: Strangford Lough and Lough Hyne, Ireland. Three different measures of genetic distance were used: FST, Dest and a measure of allelic dissimilarity, along with a direct assessment of the total number of alleles in different candidate networks. Standardized site scores were used for comparisons across methods and selection criteria. The average score for Castlehaven, a site relatively close to Lough Hyne, was highest, implying that this site would capture the most genetic diversity while ensuring highest degree of interaction between protected and unprotected sites. Patterns around Strangford Lough were more ambiguous, potentially reflecting the weaker genetic structure around this protected area in comparison to Lough Hyne. Similar patterns were found across species with different dispersal capacities, indicating that methods based on genetic distance could be used to help maximise ecological coherence in reserve networks. ⺠Ecological coherence is a key component of marine protected area network design. ⺠Coherence contains a number of competing concepts. ⺠Genetic information from field populations can help guide assessments of coherence. ⺠Average choice across different concepts of coherence was consistent among species. ⺠Measures can be combined to compare the coherence of different network designs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although there have been a number of studies in adults, to date there has been little research into sequential antimicrobial therapy (SAT) in paediatric populations. The present study evaluates the impact of a SAT protocol for the treatment of severe lower respiratory tract infection in paediatric patients. The study involved 89 paediatric patients (44 control and 45 SAT). The SAT patients had a shorter length of hospital stay (4.0 versus 8.3 days), shorter duration of inpatient antimicrobial therapy (4.0 versus 7.9 days) with the period of iv therapy being reduced from a mean of 5.6 to 1.7 days. The total healthcare costs were reduced by 52%. The resolution of severe lower respiratory tract infection with a short course of iv antimicrobials, followed by conversion to oral therapy yielded clinical outcomes comparable to those achieved using longer term iv therapy. SAT proved to be an important cost-minimizing tool for realizing substantial healthcare costs savings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser plasma interferograms are currently analyzed by extraction of the phase-shift map with fast Fourier transform (FFT) techniques [Appl. Opt. 18, 3101 (1985)]. This methodology works well when interferograms are only marginally affected by noise and reduction of fringe visibility, but it can fail to produce accurate phase-shift maps when low-quality images are dealt with. We present a novel procedure for a phase-shift map computation that makes extensive use of the ridge extraction in the continuous wavelet transform (CWT) framework. The CWT tool is flexible because of the wide adaptability of the analyzing basis, and it can be accurate because of the intrinsic noise reduction in the ridge extraction. A comparative analysis of the accuracy performances of them new tool and the FFT-based one shows that the CWT-based tool produces phase maps considerably less noisy and that it can better resolve local inhomogeneties. (C) 2001 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traditional static analysis fails to auto-parallelize programs with a complex control and data flow. Furthermore, thread-level parallelism in such programs is often restricted to pipeline parallelism, which can be hard to discover by a programmer. In this paper we propose a tool that, based on profiling information, helps the programmer to discover parallelism. The programmer hand-picks the code transformations from among the proposed candidates which are then applied by automatic code transformation techniques.

This paper contributes to the literature by presenting a profiling tool for discovering thread-level parallelism. We track dependencies at the whole-data structure level rather than at the element level or byte level in order to limit the profiling overhead. We perform a thorough analysis of the needs and costs of this technique. Furthermore, we present and validate the belief that programs with complex control and data flow contain significant amounts of exploitable coarse-grain pipeline parallelism in the program’s outer loops. This observation validates our approach to whole-data structure dependencies. As state-of-the-art compilers focus on loops iterating over data structure members, this observation also explains why our approach finds coarse-grain pipeline parallelism in cases that have remained out of reach for state-of-the-art compilers. In cases where traditional compilation techniques do find parallelism, our approach allows to discover higher degrees of parallelism, allowing a 40% speedup over traditional compilation techniques. Moreover, we demonstrate real speedups on multiple hardware platforms.