965 resultados para separation method
Resumo:
Fluorescence flow cytometry was employed to assess the potential of a vital dye, hydroethiedine, for use in the detection and monitoring of the viability of hemoparasites in infected erythrocytes, using Babesia bovis as a model parasite. The studies demonstrated that hydroethidine is taken up by B. bovis and metabolically converted to the DNA binding fluorochrone, ethidium. Following uptake of the dye, erythrocytes contamine viable parasites were readily distinguished and quantitated. Timed studies with the parasiticidal drug, Ganaseg, showed that it is possible to use the fluorochrome assay to monitor the effects of the drug on the rate of replication and viability of B. bovis in culture. The assay provides a rapid method for evaluation of the in vitro effect of drugs on hemoparasites and for analysis of the effect of various components of the immune response, such as lymphokines, monocyte products, antibodies, and effector cells (T, NK, LAK, ADCC) on the growth and viability of intraerythrocytic parasites.
Resumo:
BACKGROUND AND STUDY AIMS: Various screening methods for colorectal cancer (CRC) are promoted by professional societies; however, few data are available about the factors that determine patient participation in screening, which is crucial to the success of population-based programs. This study aimed (i) to identify factors that determine acceptance of screening and preference of screening method, and (ii) to evaluate procedure success, detection of colorectal neoplasia, and patient satisfaction with screening colonoscopy. PATIENTS AND METHODS: Following a public awareness campaign, the population aged 50 - 80 years was offered CRC screening in the form of annual fecal occult blood tests, flexible sigmoidoscopy, a combination of both, or colonoscopy. RESULTS: 2731 asymptomatic persons (12.0 % of the target population) registered with and were eligible to take part in the screening program. Access to information and a positive attitude to screening were major determinants of participation. Colonoscopy was the method preferred by 74.8 % of participants. Advanced colorectal neoplasia was present in 8.5 %; its prevalence was higher in males and increased with age. Significant complications occurred in 0.5 % of those undergoing colonoscopy and were associated with polypectomy or sedation. Most patients were satisfied with colonoscopy and over 90 % would choose it again for CRC screening. CONCLUSIONS: In this population-based study, only a small proportion of the target population underwent CRC screening despite an extensive information campaign. Colonoscopy was the preferred method and was safe. The determinants of participation in screening and preference of screening method, together with the distribution of colorectal neoplasia in different demographic categories, provide a rationale for improving screening procedures.
Resumo:
We propose a mixed finite element method for a class of nonlinear diffusion equations, which is based on their interpretation as gradient flows in optimal transportation metrics. We introduce an appropriate linearization of the optimal transport problem, which leads to a mixed symmetric formulation. This formulation preserves the maximum principle in case of the semi-discrete scheme as well as the fully discrete scheme for a certain class of problems. In addition solutions of the mixed formulation maintain exponential convergence in the relative entropy towards the steady state in case of a nonlinear Fokker-Planck equation with uniformly convex potential. We demonstrate the behavior of the proposed scheme with 2D simulations of the porous medium equations and blow-up questions in the Patlak-Keller-Segel model.
Resumo:
A method for the simultaneous determination of intact glucosinolates and main phenolic compounds (flavonoids and sinapic acid derivatives) in Brassica oleracea L. var. botrytis was proposed. A simplified sample extraction procedure and a UPLC separation were carried out to reduce the total time of analysis. Brassica oleracea samples were added with internal standards (glucotropaeolin and rutin), and extracted with boiling methanol. Crude extracts were evaporated under nitrogen, redissolved in mobile phase and analyzed by UPLC with double detection (ESI--MRM for glucosinolates and flavonoids, and DAD for main sinapic acid derivatives). The proposed method allowed a satisfactory quantification of main native sinapic acid derivatives, flavonoids and glucosinolates with a reduced time of analysis.
Resumo:
Introduction: The general strategy to perform anti-doping analysis starts with a screening followed by a confirmatory step when a sample is suspected to be positive. The screening step should be fast, generic and able to highlight any sample that may contain a prohibited substance by avoiding false negative and reducing false positive results. The confirmatory step is a dedicated procedure comprising a selective sample preparation and detection mode. Aim: The purpose of the study is to develop rapid screening and selective confirmatory strategies to detect and identify 103 doping agents in urine. Methods: For the screening, urine samples were simply diluted by a factor 2 with ultra-pure water and directly injected ("dilute and shoot") in the ultrahigh- pressure liquid chromatography (UHPLC). The UHPLC separation was performed in two gradients (ESI positive and negative) from 5/95 to 95/5% of MeCN/Water containing 0.1% formic acid. The gradient analysis time is 9 min including 3 min reequilibration. Analytes detection was performed in full scan mode on a quadrupole time-of-flight (QTOF) mass spectrometer by acquiring the exact mass of the protonated (ESI positive) or deprotonated (ESI negative) molecular ion. For the confirmatory analysis, urine samples were extracted on SPE 96-well plate with mixed-mode cation (MCX) for basic and neutral compounds or anion exchange (MAX) sorbents for acidic molecules. The analytes were eluted in 3 min (including 1.5 min reequilibration) with a S1-25 Ann Toxicol Anal. 2009; 21(S1) Abstracts gradient from 5/95 to 95/5% of MeCN/Water containing 0.1% formic acid. Analytes confirmation was performed in MS and MS/MS mode on a QTOF mass spectrometer. Results: In the screening and confirmatory analysis, basic and neutral analytes were analysed in the positive ESI mode, whereas acidic compounds were analysed in the negative mode. The analyte identification was based on retention time (tR) and exact mass measurement. "Dilute and shoot" was used as a generic sample treatment in the screening procedure, but matrix effect (e.g., ion suppression) cannot be avoided. However, the sensitivity was sufficient for all analytes to reach the minimal required performance limit (MRPL) required by the World Anti Doping Agency (WADA). To avoid time-consuming confirmatory analysis of false positive samples, a pre-confirmatory step was added. It consists of the sample re-injection, the acquisition of MS/MS spectra and the comparison to reference material. For the confirmatory analysis, urine samples were extracted by SPE allowing a pre-concentration of the analyte. A fast chromatographic separation was developed as a single analyte has to be confirmed. A dedicated QTOF-MS and MS/MS acquisition was performed to acquire within the same run a parallel scanning of two functions. Low collision energy was applied in the first channel to obtain the protonated molecular ion (QTOF-MS), while dedicated collision energy was set in the second channel to obtain fragmented ions (QTOF-MS/MS). Enough identification points were obtained to compare the spectra with reference material and negative urine sample. Finally, the entire process was validated and matrix effects quantified. Conclusion: Thanks to the coupling of UHPLC with the QTOF mass spectrometer, high tR repeatability, sensitivity, mass accuracy and mass resolution over a broad mass range were obtained. The method was sensitive, robust and reliable enough to detect and identify doping agents in urine. Keywords: screening, confirmatory analysis, UHPLC, QTOF, doping agents
Resumo:
The paper discusses the utilization of new techniques ot select processes for protein recovery, separation and purification. It describesa rational approach that uses fundamental databases of proteins molecules to simplify the complex problem of choosing high resolution separation methods for multi component mixtures. It examines the role of modern computer techniques to help solving these questions.
Resumo:
OBJECTIVES: Family studies typically use multiple sources of information on each individual including direct interviews and family history information. The aims of the present study were to: (1) assess agreement for diagnoses of specific substance use disorders between direct interviews and the family history method; (2) compare prevalence estimates according to the two methods; (3) test strategies to approximate prevalence estimates according to family history reports to those based on direct interviews; (4) determine covariates of inter-informant agreement; and (5) identify covariates that affect the likelihood of reporting disorders by informants. METHODS: Analyses were based on family study data which included 1621 distinct informant (first-degree relatives and spouses) - index subject pairs. RESULTS: Our main findings were: (1) inter-informant agreement was fair to good for all substance disorders, except for alcohol abuse; (2) the family history method underestimated the prevalence of drug but not alcohol use disorders; (3) lowering diagnostic thresholds for drug disorders and combining multiple family histories increased the accuracy of prevalence estimates for these disorders according to the family history method; (4) female sex of index subjects was associated with higher agreement for nearly all disorders; and (5) informants who themselves had a history of the same substance use disorder were more likely to report this disorder in their relatives, which entails the risk of overestimation of the size of familial aggregation. CONCLUSION: Our findings have important implications for the best-estimate procedure applied in family studies.
Resumo:
In this paper we propose a stabilized conforming finite volume element method for the Stokes equations. On stating the convergence of the method, optimal a priori error estimates in different norms are obtained by establishing the adequate connection between the finite volume and stabilized finite element formulations. A superconvergence result is also derived by using a postprocessing projection method. In particular, the stabilization of the continuous lowest equal order pair finite volume element discretization is achieved by enriching the velocity space with local functions that do not necessarily vanish on the element boundaries. Finally, some numerical experiments that confirm the predicted behavior of the method are provided.
Resumo:
The antibiotic susceptibilities of Neisseria gonorrhoeae isolates obtained from patients attending a clinic for sexually transmitted diseases in Tucumán, Argentina, were determined by the agar dilution method (MIC). 3.5% of the isolates produced ²-lactamase. A total of 96.5% of ²-lactamase negative isolates tested were susceptible to penicillin (MIC < 2 µgml-1); 14.03% of the tested isolates were resistant to tetracycline (MIC < 2 µgml-1), and 98% of the tested isolates were susceptible to spectinomycin (MIC < 64 µgml-1). The MICs for 95% of the isolates, tested for other drugs were: < 2 µgml-1 for cefoxitin, < 0.06 µgml-1 for cefotaxime, < 0.25 µgml-1 for norfloxacin, < 10 µgml-1 for cephaloridine, < 10 µgml-1 for cephalexin, and < 50 µgml-1 for kanamycin. Antibiotic resistance among N. gonorrhoeae isolates from Tucumán, Argentina, appeared to be primarily limited to penicillin and tetracycline, which has been a general use against gonorrhoeae in Tucumán since 1960. Periodic monitoring of the underlying susceptibility profiles of the N. gonorrhoeae strains prevalent in areas of frequent transmission may provide clues regarding treatment options and emerging of drug resistance.