837 resultados para renewable energy engineering
Resumo:
The European Union has set a target of 20% for the share of renewable energy sources in gross final energy consumption in 2020. These renewable energy targets are priority objectives for the Europe 2020 strategy for inclusive growth. In line with the European Union renewable energy policies, the Northern Ireland Executive has a target to deliver 40% renewable electricity by 2020. Currently, Northern Ireland imports 98% of the energy it uses in the form of fossil fuels. Locally produced energy and electricity is needed to ensure sustainable development. The aim of this research is to develop part of a strategy for the mechanical power take-off system for a flap type wave energy converter. Aquamarine Power Ltd’s Oyster flap was the device used for simulation and testing purposes. In this paper the state-of-the-art of wave energy converters is reviewed and a 40th scale test model was developed and built.
Resumo:
In the United Kingdom wind power is recognised as the main source of renewable energy to achieve the European Union 2020 renewable energy targets. Currently over 50% of renewable power is generated from onshore wind with a large number of offshore wind projects in development. Recently the government has re-iterated its commitment to offshore wind power and has announced that offshore wind subsidies are to increase from £135/MWh to £140/MWh until 2019. This paper provides a detailed overview of the offshore wind power industry in the United Kingdom in terms of market growth, policy development and offshore wind farm costs. The paper clearly shows that the United Kingdom is the world leader for installed offshore wind power capacity as pro-active policies and procedures have made it the most attractive location to develop offshore wind farm arrays. The key finding is that the United Kingdom has the potential to continue to lead the world in offshore wind power as it has over 48 GW of offshore wind power projects at different stages of operation and development. The growth of offshore wind power in the United Kingdom has seen offshore wind farm costs rise and level off at approximately £3 million/MW, which are higher than onshore wind costs at £1.5–2 million/MW. Considering the recent increase in offshore wind power subsidies and plans for 48 GW of offshore wind power could see more offshore wind power becoming increasingly financially competitive with onshore wind power. Therefore offshore wind power is likely to become a significant source of electricity in the United Kingdom beyond 2020.
Resumo:
Although pumped hydro storage is seen as a strategic key asset by grid operators, financing it is complicated in new liberalised markets. It could be argued that the optimum generation portfolio is now determined by the economic viability of generators based on a short to medium term return on investment. This has meant that capital intensive projects such as pumped hydro storage are less attractive for wholesale electricity companies because the payback periods are too long. In tandem a significant amount of wind power has entered the generation mix, which has resulted in operating and planning integration issues due to wind's inherent uncertain, varying spatial and temporal nature. These integration issues can be overcome using fast acting gas peaking plant or energy storage. Most analysis of wind power integration using storage to date has used stochastic optimisation for power system balancing or arbitrage modelling to examine techno-economic viability. In this research a deterministic dynamic programming long term generation expansion model is employed to optimise the generation mix, total system costs and total carbon dioxide emissions, and unlike other studies calculates reserve to firm wind power. The key finding of this study is that the incentive to build capital-intensive pumped hydro storage to firm wind power is limited unless exogenous market costs come very strongly into play. Furthermore it was demonstrated that reserve increases with increasing wind power showing the importance of ancillary services in future power systems. © 2014 Elsevier Ltd. All rights reserved.
Resumo:
Tidal turbines have been tested extensively at many scales in steady state flow. Testing medium- or full-scale devices in turbulent flow has been less thoroughly examined. The differences between turbine performances in these two different states are needed for testing method verification and numerical model validation. The work in this paper documents the performance of a 1/10 scale turbine in steady state pushing tests and tidal moored tests. The overall performance of the device appears to decrease with turbulent flow, though there is increased data scatter and therefore, reduced uncertainty. At maximum power performance, as velocity increases the mechanical power and electrical power reduction from steady to unsteady flow increases. The drive train conversion efficiency also decreases. This infers that the performance for this turbine design is affected by the presence of turbulent flow.
Resumo:
The study outlined in Testing Tidal Turbines Part 1 explains the variation in performance between turbines operating in steady and turbulent flow conditions. However, the impact of turbulence on devices is generally not well understood. Furthermore, the turbulence characteristics of high velocity marine currents have not been extensively studied. Therefore, knowledge of their characteristics must be expanded and methodologies to predict the impact of the characteristics on devices developed and improved. This study examines the measurement of tidal currents at a site used for testing of medium scale tidal turbines. The data being discussed was collected with a point velocimeter (ADV). The processing procedures implemented are discussed and the resulting estimated turbulence spectra and turbulence intensities are presented. The results contribute to the improvement of knowledge regarding tidal current characteristics. This will be fundamental to the optimisation of the design and operation of tidal stream devices.
Resumo:
Data processing is an essential part of Acoustic Doppler Profiler (ADP) surveys, which have become the standard tool in assessing flow characteristics at tidal power development sites. In most cases, further processing beyond the capabilities of the manufacturer provided software tools is required. These additional tasks are often implemented by every user in mathematical toolboxes like MATLAB, Octave or Python. This requires the transfer of the data from one system to another and thus increases the possibility of errors. The application of dedicated tools for visualisation of flow or geographic data is also often beneficial and a wide range of tools are freely available, though again problems arise from the necessity of transferring the data. Furthermore, almost exclusively PCs are supported directly by the ADP manufacturers, whereas small computing solutions like tablet computers, often running Android or Linux operating systems, seem better suited for online monitoring or data acquisition in field conditions. While many manufacturers offer support for developers, any solution is limited to a single device of a single manufacturer. A common data format for all ADP data would allow development of applications and quicker distribution of new post processing methodologies across the industry.
Resumo:
Field testing studies are required for tidal turbine device developers to determine the performance of their turbines in tidal flows. Full-scale testing of the SCHOTTEL tidal turbine has been conducted at Queen’s University Belfast’s tidal site at Strangford Lough, NI. The device was mounted on a floating barge. Testing was conducted over 48 days, for 288 h, during flood tides in daylight hours. Several instruments were deployed, resulting in an expansive data set. The performance results from this data set are presented here. The device, rated to 50 kW at 2.75 m/s was tested in flows up to 2.5 m/s, producing up to 19 kW, when time-averaged. The thrust on the turbine reached 17 kN in the maximum flow. The maximum system efficiency of the turbine in these flows reached 35%. The test campaign was very successful and further tests may be conducted at higher flow speeds in a similar tidal environment.
Resumo:
This paper describes the problems in experimentally obtaining hydrodynamic loads on an oscillating wave surge converter during slamming events, with the aim of furthering understanding of full scale hydrodynamic loads that flap type devices must be designed to withstand. Including how hydro-elastic effects and structural response are linked and why they are essential to the measurement of impulsive hydrodynamic loads. A combined experimental and numerical structural response study carried out on a 40th scale Oyster model drew conclusions on the structural vibration observed in the strain gauge load cell measurement. A further structural response study on a piezo electric load measurement device gave an insight into the advantages it could bring to reducing hydro-elastic effects.
Resumo:
Large loads result in expensive foundations which are a substantial proportion of the capital cost of flap-type Wave Energy Converters (WECs). Devices such as Oyster 800, currently deployed at the European Marine Energy Centre (EMEC), comprise a single flap for the full width of the machine. Splitting a flap-type device into smaller vertical flap modules, to make a ‘modular-flap’, might reduce the total foundation loads, whilst still providing acceptable performance in terms of energy conversion.
This paper investigates the foundation loads of an undamped modular-flap device, comparing them to those for a rigid flap of an equivalent width. Physical modelling in a wave tank is used, with loads recorded using a six degree of freedom (DoF) load cell. Both fatigue and extreme loading analysis was conducted. The rotations of the flaps were also recorded, using a motion-tracking system.
Resumo:
The development of appropriate Electric Vehicle (EV) charging strategies has been identified as an effective way to accommodate an increasing number of EVs on Low Voltage (LV) distribution networks. Most research studies to date assume that future charging facilities will be capable of regulating charge rates continuously, while very few papers consider the more realistic situation of EV chargers that support only on-off charging functionality. In this work, a distributed charging algorithm applicable to on-off based charging systems is presented. Then, a modified version of the algorithm is proposed to incorporate real power system constraints. Both algorithms are compared with uncontrolled and centralized charging strategies from the perspective of both utilities and customers. © 2013 IEEE.
Resumo:
Studies of urban metabolism provide important insights for environmental management of cities, but are not widely used in planning practice due to a mismatch of data scale and coverage. This paper introduces the Spatial Allocation of Material Flow Analysis (SAMFA) model as a potential decision support tool aimed as a contribution to overcome some of these difficulties and describes its pilot use at the county level in the Republic of Ireland. The results suggest that SAMFA is capable of identifying hotspots of higher material and energy use to support targeted planning initiatives, while its ability to visualise different policy scenarios supports more effective multi-stakeholder engagement. The paper evaluates this pilot use and sets out how this model can act as an analytical platform for the industrial ecology–spatial planning nexus.