992 resultados para pulsed laser deposition


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arabidopsis (Arabidopsis thaliana) leaf trichomes are single-cell structures with a well-studied development, but little is understood about their function. Developmental studies focused mainly on the early shaping stages, and little attention has been paid to the maturation stage. We focused on the EXO70H4 exocyst subunit, one of the most up-regulated genes in the mature trichome. We uncovered EXO70H4-dependent development of the secondary cell wall layer, highly autofluorescent and callose rich, deposited only in the upper part of the trichome. The boundary is formed between the apical and the basal parts of mature trichome by a callose ring that is also deposited in an EXO70H4-dependent manner. We call this structure the Ortmannian ring (OR). Both the secondary cell wall layer and the OR are absent in the exo70H4 mutants. Ecophysiological aspects of the trichome cell wall thickening include interference with antiherbivore defense and heavy metal accumulation. Ultraviolet B light induces EXO70H4 transcription in a CONSTITUTIVE PHOTOMORPHOGENIC1-dependent way, resulting in stimulation of trichome cell wall thickening and the OR biogenesis. EXO70H4-dependent trichome cell wall hardening is a unique phenomenon, which may be conserved among a variety of the land plants. Our analyses support a concept that Arabidopsis trichome is an excellent model to study molecular mechanisms of secondary cell wall deposition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two main coal-bearing sequences developed during the Oligocene in the Tertiary Ebro Basin, the Calaf (early Oligocene) and Mequinenza (late Oligocene) coal basins. Coal deposition took place in shallow marsh-swamp-lake complexes which sometimes became closed and evolved under warm climatic conditions with fluctuating humidity. These shallow lacustrine systems are closely interrelated with the terminal parts of the distributive fluvial systems which spread from the tectonically active Ebro basin margins. Laterally extensive lignite-bearing sequences, including rather thin, lenticular autochthonous and/or hypautochthonous coal seams with high ash and sulphur contents, characterized coal deposition in the shallow lacustrine systems. Coal seam geometry, which makes them nearly subeconomic, resulted from the tectonic instability during basin margin evolution and the sometimes closed, arid conditions under which the lacustrine systems evolved. High ash and sulphur contents resulted from the inadequate isolation of peat forming environments from clastic influx and from the very low acidity and sometimes high sulphate contents of the lacustrine waters. Coal exploration in shallow lacustrine sequences similar to those described here must take into account that the spread of coal-forming environments and maxima of coal deposition are usually coincident with lake expansions and retraction or shifting of the terminal fluvial zones interrelated with the lacustrine areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The University of Barcelona is developing a pilot-scale hot wire chemical vapor deposition (HW-CVD) set up for the deposition of nano-crystalline silicon (nc-Si:H) on 10 cm × 10 cm glass substrate at high deposition rate. The system manages 12 thin wires of 0.15-0.2 mm diameter in a very dense configuration. This permits depositing very uniform films, with inhomogeneities lower than 2.5%, at high deposition rate (1.5-3 nm/s), and maintaining the substrate temperature relatively low (250 °C). The wire configuration design, based on radicals' diffusion simulation, is exposed and the predicted homogeneity is validated with optical transmission scanning measurements of the deposited samples. Different deposition series were carried out by varying the substrate temperature, the silane to hydrogen dilution and the deposition pressure. By means of Fourier transform infrared spectroscopy (FTIR), the evolution in time of the nc-Si:H vibrational modes was monitored. Particular importance has been given to the study of the material stability against post-deposition oxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The very usual columnar growth of nanocrystalline silicon leads to electronic transport anisotropies. Whereas electrical measurements with coplanar electrodes only provide information about the electronic transport parallel to the substrate, it is the transverse transport which determines the collection efficiency in thin film solar cells. Hence, Schottky diodes on transparent electrodes were obtained by hot-wire CVD in order to perform external quantum efficiency and surface photovoltage studies in sandwich configuration. These measurements allowed to calculate a transverse collection length, which must correlate with the photovoltaic performance of thin film solar cells. Furthermore, the density of charge trapped at localized states in the bandgap was estimated from the voltage dependence of the depletion capacitance of these rectifying contacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hitsaavassa teollisuudessa kilpailukyvyn säilyttäminen edellyttää hitsauksen tehokkuuden nostoa. Niinpä metalliteollisuus etsii kuumeisesti uusia yhä tehokkaampia hitsausmenetelmiä. CO2-laserin ja MAG:in yhdistelmän muodostamalla hybridihitsauksella saadaan aikaan syvä tunkeuma kuten laserhitsauksessa, mutta sallitaan laserhitsausta väljemmät railotoleranssit. Samalla muodonmuutokset vähenevät huomattavasti verrattuna perinteiseen kaarihitsaukseen. Kaariavusteisessa laserhitsauksessa yhdistetään laserhitsaukseen perinteinen kaarihitsaus eli MIG/MAG-, TIG- tai plasmahitsaus. Menetelmää voidaan kutsua myös hybridihitsaukseksi ja sillä hyödynnetään molempien prosessien edut välttyen yksittäisten prosessien haitoilta. Prosessin haittapuolena on parametrien suuri määrä, joka on rajoittanut menetelmän käyttöönottoa. Diplomityössä tutkittiin suojakaasuseoksen koostumuksen vaikutusta rakenneteräksen CO2-laser-MAG-hybridihitsauksessa. Laserhitsauksen ja MAG-hitsauksen suojakaasuvirtaukset yhdistettiin siten, että heliumseosteinen suojakaasu tuotiin MAG-polttimen kaasukuvun kautta. Suojakaasun heliumpitoisuus nostettiin niin korkeaksi, että estettiin laserhitsauksen muodostaman plasman syntyminen. Samalla hitsauskokeissa opittiin paremmin ymmärtämään prosessia ja sen parametrien riippuvuutta toisiinsa. Tutkitut suojakaasuseokset koostuivat heliumista, argonista ja hiilidioksidista. Hitsauskokeiden perusteella havaittiin, että suojakaasuseoksen optimaalinen heliumpitoisuus on 40-50 %. Tällöin laserin tunkeumaa häiritsevää plasmapilveä ei synny ja prosessi on stabiili. Päittäisliitosten hitsauksessa suojakaasuseoksen 2 %:n CO2-pitoisuudella saadaan aikaan hyvin vähän huokosia sisältävä hitsi, jonka tunkeumaprofiilin muoto ja liittymä perusaineeseen on juoheva. Pienaliitoksilla 7 %:n CO2-pitoisuudella prosessi pysyy stabiilina ja vähäroiskeisena. Tunkeuma hieman levenee hitsin keskeltä ja hitsin liittyminen perusaineeseen on juoheva.CO2-laser-MAG-hybridihitsauksella aikaansaadaan laadukkaita hitsejä taloudellisesti, mikäli käytetyt parametrit ovat oikein valittuja. Parametrit on sovitettava jokaiseen hitsaustapaukseen erikseen, eikä niitä välttämättä voida suoraan käyttää toisessa tapauksessa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this in vitro experimental study was to perform histological evaluation of the thermal effect produced on soft tissue irradiated with CO2, Er,Cr:YSGG or diode lasers. Study design: Porcine oral mucosa samples were irradiated with Er,Cr:YSGG laser at 1 W with and without water / air spray, at 2 W with and without water / air spray, and at 4 W with water / air spray, with CO2 laser at 1 W, 2 W, 10 W, 20 W continuous mode and 20 W pulsed mode and diode laser at 2W, 5W, and 10W pulsed mode. The thermal effect was evaluated measuring the width of damaged tissue adjacent to the incision, stained positively for hyalinized tissue with Hematoxylin-Eosin and Masson Trichrome stains. Besides, histological changes in the irradiated tissue were described using subjective grading scales. Results: The evaluated lasers developed a wide range of thermal damage with significant differences between groups. The samples with lowest thermal effect were those irradiated with Er,Cr:YSGG laser using water / air spray, followed by CO2 and diode lasers. Conclusions: Emission parameters of each laser system may influence the thermal damage inflicted on the soft tissue, however, the wave length of each laser determines the absorption rate characteristics of every tissue and the thermal effect

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser diffraction (LD) and static image analysis (SIA) of rectangular particles [United States Pharmacopeia, USP30-NF25, General Chapter <776>, Optical Miroscopy.] have been systematically studied. To rule out sample dispersion and particle orientation as the root cause of differences in size distribution profiles, we immobilize powder samples on a glass plate by means of a dry disperser. For a defined region of the glass plate, we measure the diffraction pattern as induced by the dispersed particles, and the 2D dimensions of the individual particles using LD and optical microscopy, respectively. We demonstrate a correlation between LD and SIA, with the scattering intensity of the individual particles as the dominant factor. In theory, the scattering intensity is related to the square of the projected area of both spherical and rectangular particles. In traditional LD the size distribution profile is dominated by the maximum projected area of the particles (A). The diffraction diameters of a rectangular particle with length L and breadth B as measured by the LD instrument approximately correspond to spheres of diameter ØL and ØB respectively. Differences in the scattering intensity between spherical and rectangular particles suggest that the contribution made to the overall LD volume probability distribution by each rectangular particle is proportional to A2/L and A2/B. Accordingly, for rectangular particles the scattering intensity weighted diffraction diameter (SIWDD) explains an overestimation of their shortest dimension and an underestimation of their longest dimension. This study analyzes various samples of particles whose length ranges from approximately 10 to 1000 μm. The correlation we demonstrate between LD and SIA can be used to improve validation of LD methods based on SIA data for a variety of pharmaceutical powders all with a different rectangular particle size and shape.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate different laser cutting nozzles, nozzle flows and possibilities to improve nozzle flow. Another goal was to design new nozzle configuration in which laser cutting would succeed with better cutting speed and smaller gas consumption. Nozzles and nozzle flows were studied with various methods. Computational fluid dynamics was used to calculate old, convergent nozzles and new convergent-divergent nozzles. Measurement apparatus was used to measure both nozzle types. In cutting tests different materials were cut with new nozzles. With the use of design convergent-divergent nozzles 25 % better cutting speed and 33 % smaller gas consumption were achieved when cutting quality was good. Computational fluid dynamics was also discovered to be useful aid in nozzle design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lasers in pediatric dermatology were developed as a result of the treatment of port-wine stains. Infantile hemangiomas may benefit, in some cases, from laser treatment as well as venous and lymphatic malformations. For certain pigmented lesions, as well as some hamartomas, laser treatments are a credible alternative to surgical resection. Bum scars are improved by lasers which stimulate collagen remodeling. Furthermore, hair removal of congenital and acquired hypertrichosis can relieve psychosocial discomfort and improve quality of life. The management of pain and fear of children undergoing laser treatment, using either topical or general anesthesia, remains of central importance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä insinöörityössä otettiin käyttöön VTI Technologies Oy:lle hankittu laser Doppler - vibrometri, joka mittaa tärinää perustuen valon Dopplerin siirtymään. Työn tavoitteena oli perehtyä mittauslaitteistoon, muodostaa sille näytteenottolaitteisto ja käytännössä arvioida sen kyvykkyyttä mitata tärinää ja tuottaa uutta informaatiota. Työn teoreettisessa osuudessa perehdytään laser Doppler -vibrometrin teknologiaan ja toimintaperiaatteeseen sekä värähtelevien systeemien dynamiikkaan ja mallintamiseen. Työn käytännön osuuden suorittamiseksi perehdyttiin myös tärinätestauslaitteiston toimintaan, analogiasignaalin näytteenottoon sekä diskreettiin Fourier-muunnokseen perustuvaan signaalin spektrianalyysiin. Työssä käsitellään myös laser-mittauksen kohinalähteitä ja spektrianalyysin virhelähteitä. Työn käytännön osuudessa ohjelmoitiin Labview-mittausohjelmisto näytteenottolaitteistolle. Mittausohjelmistolla voidaan näytteistää vibrometrin mittaussignaalia ja muodostaa sen taajuusspektri. Mittauskohteita tässä työssä olivat kulmakiihtyvyystäryttimen mekaanisen liikkeen mittaus ja elementtikiekkosahan terän värähtelyjen mittaus. Mittaustulokset kulmakiihtyvyystäryttimestä osoittivat sen mekaanisen liikkeen säröytyvän voimakkaasti, johtuen todennäköisesti sen testialustan rakenteesta. Testialustan rakennetta tullaan kehittämään ja mittaukset toistetaan. Mittaustuloksiin elementtikiekkosahasta tuli suhtautua epäillen, koska mittaussignaalin intensiteetti oli erittäin heikko. Mittausten onnistuminen Laser Doppler -vibrometrillä edellyttää riittävää mittauskohteesta takaisinheijastuneen laser-valon intensiteettiä. Mittaustulokset osoittivat laser Doppler -vibrometrin olevan hyödyllinen työkalu tutkivassa tärinämittauksessa. Mittauskohteet, joiden pinta heijastaa huonosti valoa ja joihin ei voi asentaa erityistä heijastavaa teippiä, ovat kuitenkin haaste ja asettavat rajoituksen laser Doppler -vibrometrin käyttömahdollisuuksille. Tämän työn mittaustuloksia voidaan käyttää kulmakiihtyvyystäryttimen uusintamittausten vertailukohtana, kun arvioidaan kehitystyön onnistumista. Tätä työtä voidaan käyttää myös laser Doppler -vibrometrin ohjekirjana tärinämittauksissa.