974 resultados para programação linear multiobjetivo 0-1
Resumo:
Exploitation of the electronic properties of carbon nanotubes for the development of voltammetric and amperometric sensors to monitor analytes of environmental relevance has increased in recent years. This work reports the development of a biomimetic sensor based on a carbon paste modified with 5,10,15,20-tetrakis(pentafluorophenyl)-21H,23H-porphyrin iron (III) chloride (a biomimetic catalyst of the P450 enzyme) and multi-wall carbon nanotubes (MWCNT), for the sensitive and selective detection of the herbicide 2,4- dichlorophenoxyacetic acid (2,4-D). The sensor was evaluated using cyclic voltammetry and amperometry, for electrochemical characterization and quantification purposes, respectively. Amperometric analyses were carried out at -100 mV vs. Ag/AgCl(KClsat), using a 0.1 mol L-1 phosphate buffer solution at pH 6.0 as the support electrolyte. Under these optimized analytical conditions, the sensor showed a linear response between 9.9 × 10-6 and 1.4 × 10-4 mol L-1, a sensitivity of 1.8 × 104 (±429) μA L mol -1, and limits of detection and quantification of 2.1 × 10 -6 and 6.8 × 10-6 mol L-1, respectively. The incorporation of functionalized MWCNT in the carbon paste resulted in a 10-fold increase in the response, compared to that of the biomimetic sensor without MWCNT. In addition, the low applied potential (-100 mV) used to obtain high sensitivity also contributed to the excellent selectivity of the proposed sensor. The viability of the application of this sensor for analysis of soil samples was confirmed by satisfactory recovery values, with a mean of 96% and RSD of 2.1% (n = 3). © 2013 Elsevier B.V.
Resumo:
A measurement of the λb 0 lifetime using the decay λb 0-1, was recorded with the CMS experiment at the Large Hadron Collider using triggers that selected dimuon events in the J/ψ mass region. The λb 0 lifetime is measured to be 1.503 ± 0.052 (stat.) ± 0.031 (syst.) ps. [Figure not available: see fulltext.] © 2013 Cern for the benefit of the CMS collaboration.
Resumo:
Rustic forages as the signal-grass are predominant in areas of Cerrado in extensive livestock systems that favor soil degradation. However, with time, not even these forages can have a good development in those areas. The objective of this study was to analyze the variability of plant and soil attributes; to define the linear and spatial correlations between signal-grass yield and the chemical attributes of the studied soil, and to evaluate, among the chemical attributes of the soil, which one that best explain the variability in this forage yield. The experiment was conducted in an area that had been under pasture for more than 30 years, belonging to UNESP - Ilha Solteira Campus, located in Selvíria - MS. A geostatistical grid was installed in an oxisol, for soil and plant data collection, with 121 sampling stations, consisted of eleven transections with 160 m width in the direction of the Cartesian axes. The dry mass yield of signal-grass was low, presenting high variation. The attributes MSr, N, PB, MO1, MO2, pHa1, pHa2, pHk1 and pHk2 did not vary at random. They presented data variability from low to high and followed clearly defined spatial patterns, ranging between 17.7-162.9 m. There was significant linear correlation at 1% between MSr and N leaf, and between MSr and PB. The cross semivariograms MSr=f(N) and MSr=f(PB) confirmed that the dry matter can be estimated from data of nitrogen leaf and crude protein content of this forage.
Resumo:
Canine distemper virus (CDV) is a viral disease that affects dogs and many other carnivores. Clinical diagnosis of CDV is difficult due to the broad spectrum of signs that may be confounded with other respiratory and enteric diseases of dogs. Laboratory analysis is required to diagnose suspected cases. In this study, surface plasmon resonance (SPR) and electrochemical impedance spectroscopy (EIS) methodologies were developed for the detection of canine distemper virus simultaneously. The assay exhibited high specificity, as all the negative controls were not mistakenly detected. The CDV concentration was determined from successive injections into the apparatus, with a linear range from 1.1 to 116.0 ng mL-1. The system exhibited good reproducibility with 4.5% variation between runs after regeneration of the coated surface with a solution of 0.1 M glycine-HCL (pH 3.0). The capacitance and resistance values of the modified interface were calculated from EIS data using an equivalent circuit. It was possible to measure CDV in highly concentrated viruses with good specificity and reproducibility. © 2013 The Royal Society of Chemistry.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Genética e Melhoramento Animal - FCAV