976 resultados para objective tests
Resumo:
The photocatalytic properties of self-cleaning acrylic paint containing TiO2 and ZnO were studied using Acid Orange 7 as a model compound. Paints were exposed to simulated weathering tests in a QUV panel. The initial photoactivity of the unweathered paints with ZnO was significantly higher. In the case of paints containing P25 the photocatalytic activity increases with weathering time, due to increasing destruction of the polymer resin and consequent exposure of the photocatalyst pigment to the Acid Orange 7 test solution. In contrast, in the case of paints containing ZnO, a decrease in photocatalytic activity is observed after weathering, due to the loss and/or photocorrosion of ZnO particles during the weathering process.
Resumo:
OBJECTIVE: To examine a panel of 28 biomarkers for prediction of cardiovascular disease (CVD) and non-CVD mortality in a population-based cohort of men.
METHODS: Starting in 1979, middle-aged men in Caerphilly underwent detailed medical examination. Subsequently 2171 men were re-examined during 1989-1993, and fasting blood samples obtained from 1911 men (88%). Fibrinogen, viscosity and white cell count (WCC), routine biochemistry tests and lipids were analysed using fresh samples. Stored aliquots were later analysed for novel biomarkers. Statistical analysis of CVD and non-CVD mortality follow-up used competing risk Cox regression models with biomarkers in thirds tested at the 1% significance level after covariate adjustment.
RESULTS: During an average of 15.4years follow-up, troponin (subhazard ratio per third 1.71, 95% CI 1.46-1.99) and B-natriuretic peptide (BNP) (subhazard ratio per third 1.54, 95% CI 1.34-1.78) showed strong trends with CVD death but not with non-CVD death. WCC and fibrinogen showed similar weaker findings. Plasma viscosity, growth differentiation factor 15 (GDF-15) and interleukin-6 (IL-6) were associated positively with both CVD death and non-CVD death while total cholesterol was associated positively with CVD death but negatively with non-CVD death. C-reactive protein (C-RP), alkaline phosphatase, gamma-glutamyltransferase (GGT), retinol binding protein 4 (RBP-4) and vitamin B6 were significantly associated only with non-CVD death, the last two negatively. Troponin, BNP and IL-6 showed evidence of diminishing associations with CVD mortality through follow-up.
CONCLUSION: Biomarkers for cardiac necrosis were strong, specific predictors of CVD mortality while many inflammatory markers were equally predictive of non-CVD mortality.
Resumo:
OBJECTIVE: To compare the use of a generic molecular assay to 'standard' investigations used to assist the diagnosis of late onset bacterial sepsis in very low birth weight infants (VLBW, <1500g).
METHODS: VLBW infants, greater than 48 hours of age, who were clinically suspected to have sepsis were investigated using standard tests (full blood count, C-reactive protein (at presentation) and blood culture), in addition, blood was taken for a universal molecular assay (16S rRNA reverse transcriptase PCR) for comparison. Clinical data were recorded during the suspected infection episode. A validated sepsis score (NEO-KISS) was used to retrospectively determine the presence of sepsis (independent of blood culture). The performance of each of the tests were compared by sensitivity, specificity, positive/negative likihood ratios (+/-LR) and postive/negative predictive values (PPV/NPV).
RESULTS: Sixty-five babies with suspected clinical sepsis were prospectively included. The performance indicators are presented with 95% confidence limits. For the detection of bacteria, blood culture had sensitivity of 0.57 (0.34-0.78), specificity of 0.45 (0.30-0.61); +LR of 1.05 (0.66-1.66) and-LR of 0.94 (0.52-1.7); PPV of 33.3 (18.56-50.97) and NPV of 68.97 (49.17-87.72). Serum CRP had sensitivity of 0.92 (0.64-1) and specificity of 0.36 (0.17-0.59); +LR of 1.45 (1-2.1) and-LR of 0.21 (0.03-1.5); PPV of 44.46 (26.6-66.6) and NPV of 88.9 (51.8-99.7). The universal molecular assay had sensitivity of 0.76 (0.53-0.92), specificity of 0.95 (0.85-0.99); +LR of 16.8 (4.2-66.3) and-LR of 0.25 (0.1-0.5); PPV of 88.9 (65.3-98.6) and NPV of 89.4 (76.9-96.5).
CONCLUSIONS: In VLBW infants this universal molecular assay performed better in the diagnosis of late onset sepsis (LOS) than blood culture and CRP. Further development is required to explore and improve the performance of the assay in real-time diagnosis.
Resumo:
This paper reports on the accuracy of new test methods developed to measure the air and water permeability of high-performance concretes (HPCs). Five representative HPC and one normal concrete (NC) mixtures were tested to estimate both repeatability and reliability of the proposed methods. Repeatability acceptance was adjudged using values of signal-noise ratio (SNR) and discrimination ratio (DR), and reliability was investigated by comparing against standard laboratory-based test methods (i.e., the RILEM gas permeability test and BS EN water penetration test). With SNR and DR values satisfying recommended criteria, it was concluded that test repeatability error has no significant influence on results. In addition, the research confirmed strong positive relationships between the proposed test methods and existing standard permeability assessment techniques. Based on these findings, the proposed test methods show strong potential to become recognized as international methods for determining the permeability of HPCs.
Resumo:
Summary
Background
The ability to carry out a neurological examination and make an appropriate differential diagnosis is one of the mainstays of our final Bachelor of Medicine (MB) exam; however, with the introduction of objective structured clinical examinations (OSCEs) it has become impossible to arrange for adequate numbers of suitable real patients to participate in the exam.
Context
It is vital that newly qualified doctors can perform a basic neurological examination, interpret the physical signs and formulate a differential diagnosis.
It is vital that newly qualified doctors can perform a basic neurological examination
Innovation
Since 2010 we have introduced an objective structured video examination (OSVE) of a neurological examination of a real patient as part of our final MB OSCE exam. The students view clips of parts of the examination process. They answer questions on the signs that are demonstrated and formulate a differential diagnosis.
Implications
This type of station is logistically a lot easier to organise than a large number of real patients at different examination sites. The featured patients have clearly demonstrated signs and, as every student sees the same patient, are perfectly standardised. It is highly acceptable to examiners and performed well as an assessment tool. There are, however, certain drawbacks in that we are not examining the student's examination technique or their interaction with the patient. Also, certain signs, in particular the assessment of muscle tone and power, are more difficult for a student to estimate in this situation
Resumo:
The properties of blood and the relative ease of access to which it can be retrieved make it an ideal source to gauge different aspects of homeostasis within an individual, form an accurate diagnosis, and formulate an appropriate treatment regime. Tests used to determine blood parameters such as the erythrocyte sedimentation rate, hemoglobin concentration, hematocrit, bleeding and clotting times, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, mean cell volume, and determination of blood groups are routinely used clinically, and deviations outside the normal range can indicate a range of conditions such as anemia, pregnancy, dehydration, overhydration, infectious disease, cancer, thyroid disease, and autoimmune conditions, to mention a few. As these tests can be performed relatively inexpensively and do not require high levels of technical expertise, they are ideally suited for use in the teaching laboratory, enabling undergraduate students to link theory to practice. The practicals described here permit students to examine their own blood and that of their peers and compare these with clinically accepted normal ranges. At the end of the practicals, students are required to answer a number of questions about their findings and to link abnormal values to possible pathological conditions by answering a series of questions based on their findings.
Resumo:
Temperament tests are widely accepted as instruments for profiling behavioral variability in dogs, and they are applied in numerous areas of investigation (e.g. suitability for adoption or for breeding). During testing, to elicit a dog's reaction toward novel stimuli and predict its behavior in everyday life, model devices such as a child-like doll, or a fake dog, are often employed. However, the reliability of these devices to accurately stimulate dogs' reactions to children or dogs, is unknown and perhaps overestimated. This may be a particular concern in the case of aggressive behavior toward humans, a significant public health issue. The aim of this study was to: (1) evaluate the correlation between dogs' reactions to these devices, and owners' reports of their dog's aggression history (using the C-BARQ ??); (2) compare reactions toward the devices of dogs with and without histories of aggression. Subjects were selected among those visiting for behavioral consultation at the Veterinary Hospital of the University of Pennsylvania, and previously categorized as aggressive toward unfamiliar children, conspecifics, or as non-aggressive dogs (control). The test consisted of different components: an unfamiliar female tester approaching the dog; the presentation of a child-like doll, an ambiguous object, and a fake plastic dog. All tests were videotaped and durations of behaviors were later analyzed on the basis of a specified ethogram. Dogs' reactions were compared to C-BARQ scores, and interesting correlations emerged for 'dog-directed aggression/fear' (R = 0.48, P = 0.004), and 'stranger-directed aggression' (R = 0.58, P <0.001) factors. Dogs differed in their reactions toward the devices: the child-like doll and the fake dog elicited more social behaviors than the ambiguous object used as a control stimulus. Issues concerning the reliability of these tools to assess canine temperament are discussed. ?? 2012 Elsevier B.V. All rights reserved.
Resumo:
Objective: To evaluate temporal changes in GCF levels of substance P, cathepsin G, interleukin 1 beta (IL-1&beta), neutrophil elastase and alpha1-antitrypsin (&alpha1AT) during development of and recovery from experimental gingivitis. Methods: Healthy human volunteers participated in a split-mouth study: experimental gingivitis was induced using a soft vinyl splint to cover test teeth during brushing over 21 days, after which normal brushing was resumed. Modified gingival index (MGI), gingival bleeding index (BI) and modified Quigley and Hein plaque index (PI) were assessed and 30-second GCF samples taken from 4 paired test and contra-lateral control sites in each subject at days 0, 7, 14, 21, 28 and 42. GCF volume was measured and site-specific quantification of one analyte per GCF sample was performed using radioimmunoassay (substance P), enzyme assay (cathepsin G) or ELISA (IL-1&beta, elastase, &alpha1AT). Site-specific data were analysed using analysis of repeated measurements and paired sample tests. Results: 56 subjects completed the study. All measurements at baseline (day 0) and at control sites throughout the study were low. Clinical indices and GCF volumes at the test sites increased from day 0, peaking at day 21 (difference between test and control for PI, BI, MGI and GCF all p<0.0001) and decreased again to control levels by day 28. Levels of four inflammatory markers showed a similar pattern, with significant differences between test and control apparent at 7 days (substance P p=0.0015; cathepsin G p=0.029; IL-1&beta p=0.026; elastase p=0.0129) and peaking at day 21 (substance P p=0.0023; cathepsin G, IL-1&beta and elastase all p<0.0001). Levels of &alpha1AT showed no apparent pattern over the course of the study. Conclusion: GCF levels of substance P, cathepsin G, IL-1&beta and neutrophil elastase have the potential to act as early markers of experimentally-induced gingival inflammation.
Resumo:
BACKGROUND: Impaired dark adaptation occurs commonly in vitamin A deficiency. OBJECTIVE: We sought to examine the responsiveness of dark-adaptation threshold to vitamin A and beta-carotene supplementation in Nepali women. DESIGN: The dark-adapted pupillary response was tested in 298 pregnant women aged 15-45 y in a placebo-controlled trial of vitamin A and beta-carotene; 131 of these women were also tested at 3 mo postpartum. Results were compared with those for 100 nonpregnant US women of similar age. The amount of light required for pupillary constriction was recorded after bleaching and dark adaptation. RESULTS: Pregnant women receiving vitamin A had better dark-adaptation thresholds (-1.24 log cd/m(2)) than did those receiving placebo (-1.11 log cd/m(2); P: = 0. 03) or beta-carotene (-1.13 log cd/m(2); P: = 0.05) (t tests with Bonferroni correction). Dark-adaptation threshold was associated with serum retinol concentration in pregnant women receiving placebo (P: = 0.001) and in those receiving beta-carotene (P: = 0.003) but not in those receiving vitamin A. Among women receiving placebo, mean dark-adaptation thresholds were better during the first trimester (-1.23 log cd/m(2)) than during the second and third trimesters (-1.03 log cd/m(2); P: = 0.02, t test). The mean threshold of nonpregnant US women (-1.35 log cd/m(2)) was better than that of all 3 Nepali groups (P: < 0.001, t test, for all 3 groups). CONCLUSIONS: During pregnancy, pupillary dark adaptation was strongly associated with serum retinol concentration and improved significantly in response to vitamin A supplementation. This noninvasive testing technique is a valid indicator of population vitamin A status in women of reproductive age.
Resumo:
PURPOSE:
To assess the noneconomic value of tests used in the diagnosis and management of glaucoma, and explore the contexts and factors that determine such value.
DESIGN:
Perspective.
METHODS:
Selected articles from primary and secondary sources were reviewed and interpreted in the context of the authors' clinical and research experience, influenced by our perspectives on the tasks of reducing the global problem of irreversible blindness caused by glaucoma. The value of any test used in glaucoma is addressed by 3 questions regarding: its contexts, its kind of value, and its implicit or explicit benefits.
RESULTS:
Tonometry, slit-lamp gonioscopy, and optic disc evaluation remain the foundation of clinic-based case finding, whether in areas of more or less abundant resources. In resource-poor areas, there is urgency in identifying patients at risk for severe functional loss of vision; screening strategies have proven ineffective, and efforts are hindered by the inadequate allocation of support. In resource-abundant areas, the wider spectrum of glaucoma is addressed, with emphasis on early detection of structural changes of little functional consequence; these are increasingly the focus of new and expensive technologies whose clinical value has not been established in longitudinal and population-based studies. These contrasting realities in part reflect differences among the value ascribed, often implicitly, to the tests used in glaucoma.
CONCLUSIONS:
The value of any test is determined by 3 aspects: its context of usage; its comparative worth and to whom its benefit accrues; and how we define historically what we are testing. These multiple factors
Resumo:
The main objective of the study presented in this paper was to investigate the feasibility using support vector machines (SVM) for the prediction of the fresh properties of self-compacting concrete. The radial basis function (RBF) and polynomial kernels were used to predict these properties as a function of the content of mix components. The fresh properties were assessed with the slump flow, T50, T60, V-funnel time, Orimet time, and blocking ratio (L-box). The retention of these tests was also measured at 30 and 60 min after adding the first water. The water dosage varied from 188 to 208 L/m3, the dosage of superplasticiser (SP) from 3.8 to 5.8 kg/m3, and the volume of coarse aggregates from 220 to 360 L/m3. In total, twenty mixes were used to measure the fresh state properties with different mixture compositions. RBF kernel was more accurate compared to polynomial kernel based support vector machines with a root mean square error (RMSE) of 26.9 (correlation coefficient of R2 = 0.974) for slump flow prediction, a RMSE of 0.55 (R2 = 0.910) for T50 (s) prediction, a RMSE of 1.71 (R2 = 0.812) for T60 (s) prediction, a RMSE of 0.1517 (R2 = 0.990) for V-funnel time prediction, a RMSE of 3.99 (R2 = 0.976) for Orimet time prediction, and a RMSE of 0.042 (R2 = 0.988) for L-box ratio prediction, respectively. A sensitivity analysis was performed to evaluate the effects of the dosage of cement and limestone powder, the water content, the volumes of coarse aggregate and sand, the dosage of SP and the testing time on the predicted test responses. The analysis indicates that the proposed SVM RBF model can gain a high precision, which provides an alternative method for predicting the fresh properties of SCC.
Resumo:
OBJECTIVE/BACKGROUND: Many associations between abdominal aortic aneurysm (AAA) and genetic polymorphisms have been reported. It is unclear which are genuine and which may be caused by type 1 errors, biases, and flexible study design. The objectives of the study were to identify associations supported by current evidence and to investigate the effect of study design on reporting associations.
METHODS: Data sources were MEDLINE, Embase, and Web of Science. Reports were dual-reviewed for relevance and inclusion against predefined criteria (studies of genetic polymorphisms and AAA risk). Study characteristics and data were extracted using an agreed tool and reports assessed for quality. Heterogeneity was assessed using I(2) and fixed- and random-effects meta-analyses were conducted for variants that were reported at least twice, if any had reported an association. Strength of evidence was assessed using a standard guideline.
RESULTS: Searches identified 467 unique articles, of which 97 were included. Of 97 studies, 63 reported at least one association. Of 92 studies that conducted multiple tests, only 27% corrected their analyses. In total, 263 genes were investigated, and associations were reported in polymorphisms in 87 genes. Associations in CDKN2BAS, SORT1, LRP1, IL6R, MMP3, AGTR1, ACE, and APOA1 were supported by meta-analyses.
CONCLUSION: Uncorrected multiple testing and flexible study design (particularly testing many inheritance models and subgroups, and failure to check for Hardy-Weinberg equilibrium) contributed to apparently false associations being reported. Heterogeneity, possibly due to the case mix, geographical, temporal, and environmental variation between different studies, was evident. Polymorphisms in nine genes had strong or moderate support on the basis of the literature at this time. Suggestions are made for improving AAA genetics study design and conduct.
Resumo:
Infection is a leading cause of neonatal morbidity and mortality worldwide. Premature neonates are particularly susceptible to infection because of physiologic immaturity, comorbidity, and extraneous medical interventions. Additionally premature infants are at higher risk of progression to sepsis or severe sepsis, adverse outcomes, and antimicrobial toxicity. Currently initial diagnosis is based upon clinical suspicion accompanied by nonspecific clinical signs and is confirmed upon positive microbiologic culture results several days after institution of empiric therapy. There exists a significant need for rapid, objective, in vitro tests for diagnosis of infection in neonates who are experiencing clinical instability. We used immunoassays multiplexed on microarrays to identify differentially expressed serum proteins in clinically infected and non-infected neonates. Immunoassay arrays were effective for measurement of more than 100 cytokines in small volumes of serum available from neonates. Our analyses revealed significant alterations in levels of eight serum proteins in infected neonates that are associated with inflammation, coagulation, and fibrinolysis. Specifically P- and E-selectins, interleukin 2 soluble receptor alpha, interleukin 18, neutrophil elastase, urokinase plasminogen activator and its cognate receptor, and C-reactive protein were observed at statistically significant increased levels. Multivariate classifiers based on combinations of serum analytes exhibited better diagnostic specificity and sensitivity than single analytes. Multiplexed immunoassays of serum cytokines may have clinical utility as an adjunct for rapid diagnosis of infection and differentiation of etiologic agent in neonates with clinical decompensation.
Resumo:
Roadside safety barriers designs are tested with passenger cars in Europe using standard EN1317 in which the impact angle for normal, high and very high containment level tests is 20°. In comparison to EN1317, the US standard MASH has higher impact angles for cars and pickups (25°) and different vehicle masses. Studies in Europe (RISER) and the US have shown values for the 90th percentile impact angle of 30°–34°. Thus, the limited evidence available suggests that the 20° angle applied in EN 1317 may be too low.
The first goal of this paper is to use the US NCHRP database (Project NCHRP 17–22) to assess the distribution of impact angle and collision speed in recent ROR accidents. Second, based on the findings of the statistical analysis and on analysis of impact angles and speeds in the literature, an LS-DYNA finite element analysis was carried out to evaluate the normal containment level of concrete barriers in non-standard collisions. The FE model was validated against a crash test of a portable concrete barrier carried out at the UK Transport Research Laboratory (TRL).
The accident data analysis for run-off road accidents indicates that a substantial proportion of accidents have an impact angle in excess of 20°. The baseline LS-DYNA model showed good comparison with experimental acceleration severity index (ASI) data and the parametric analysis indicates a very significant influence of impact angle on ASI. Accordingly, a review of European run-off road accidents and the configuration of EN 1317 should be performed.
Resumo:
A new heuristic based on Nawaz–Enscore–Ham (NEH) algorithm is proposed for solving permutation flowshop scheduling problem in this paper. A new priority rule is proposed by accounting for the average, mean absolute deviation, skewness and kurtosis, in order to fully describe the distribution style of processing times. A new tie-breaking rule is also introduced for achieving effective job insertion for the objective of minimizing both makespan and machine idle-time. Statistical tests illustrate better solution quality of the proposed algorithm, comparing to existing benchmark heuristics.