894 resultados para nano-KH


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of quantum dots (QDs) in the area of fingermark detection is currently receiving a lot of attention in the forensic literature. Most of the research efforts have been devoted to cadmium telluride (CdTe) quantum dots often applied as powders to the surfaces of interests. Both the use of cadmium and the nano size of these particles raise important issues in terms of health and safety. This paper proposes to replace CdTe QDs by zinc sulphide QDs doped with copper (ZnS:Cu) to address these issues. Zinc sulphide-copper doped QDs were successfully synthesized, characterized in terms of size and optical properties and optimized to be applied for the detection of impressions left in blood, where CdTe QDs proved to be efficient. Effectiveness of detection was assessed in comparison with CdTe QDs and Acid Yellow 7 (AY7, an effective blood reagent), using two series of depletive blood fingermarks from four donors prepared on four non-porous substrates, i.e. glass, transparent polypropylene, black polyethylene and aluminium foil. The marks were cut in half and processed separately with both reagents, leading to two comparison series (ZnS:Cu vs. CdTe, and ZnS:Cu vs. AY7). ZnS:Cu proved to be better than AY7 and at least as efficient as CdTe on most substrates. Consequently, copper-doped ZnS QDs constitute a valid substitute for cadmium-based QDs to detect blood marks on non-porous substrates and offer a safer alternative for routine use.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transport in small-scale biological and soft-matter systems typically occurs under confinement conditions in which particles proceed through obstacles and irregularities of the boundaries that may significantly alter their trajectories. A transport model that assimilates the confinement to the presence of entropic barriers provides an efficient approach to quantify its effect on the particle current and the diffusion coefficient. We review the main peculiarities of entropic transport and treat two cases in which confinement effects play a crucial role, with the appearance of emergent properties. The presence of entropic barriers modifies the mean first-passage time distribution and therefore plays a very important role in ion transport through micro- and nano-channels. The functionality of molecular motors, modeled as Brownian ratchets, is strongly affected when the motor proceeds in a confined medium that may constitute another source of rectification. The interplay between ratchet and entropic rectification gives rise to a wide variety of dynamical behaviors, not observed when the Brownian motor proceeds in an unbounded medium. Entropic transport offers new venues of transport control and particle manipulation and new ways to engineer more efficient devices for transport at the nanoscale.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Magnetic resonance angiography (MRA) provides a noninvasive means to detect the presence, location and severity of atherosclerosis throughout the vascular system. In such studies, and especially those in the coronary arteries, the vessel luminal area is typically measured at multiple cross-sectional locations along the course of the artery. The advent of fast volumetric imaging techniques covering proximal to mid segments of coronary arteries necessitates automatic analysis tools requiring minimal manual interactions to robustly measure cross-sectional area along the three-dimensional track of the arteries in under-sampled and non-isotropic datasets. In this work, we present a modular approach based on level set methods to track the vessel centerline, segment the vessel boundaries, and measure transversal area using two user-selected endpoints in each coronary of interest. Arterial area and vessel length are measured using our method and compared to the standard Soap-Bubble reformatting and analysis tool in in-vivo non-contrast enhanced coronary MRA images.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nanoparticles are increasingly used in various fields, including biomedicine and electronics. One application utilizes the opacifying effect of nano-TiO(2), which is frequently used as pigment in cosmetics. Although TiO(2) is believed to be biologically inert, an emerging literature reports increased incidence of respiratory diseases in people exposed to TiO(2). Here, we show that nano-TiO(2) and nano-SiO(2), but not nano-ZnO, activate the NLR pyrin domain containing 3 (Nlrp3) inflammasome, leading to IL-1β release and in addition, induce the regulated release of IL-1α. Unlike other particulate Nlrp3 agonists, nano-TiO(2)-dependent-Nlrp3 activity does not require cytoskeleton-dependent phagocytosis and induces IL-1α/β secretion in nonphagocytic keratinocytes. Inhalation of nano-TiO(2) provokes lung inflammation which is strongly suppressed in IL-1R- and IL-1α-deficient mice. Thus, the inflammation caused by nano-TiO(2) in vivo is largely caused by the biological effect of IL-1α. The current use of nano-TiO(2) may present a health hazard due to its capacity to induce IL-1R signaling, a situation reminiscent of inflammation provoked by asbestos exposure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of the addition to sausage mix of tocopherols (200 mg/kg), a conventional starter culture with or without Staphylococcus carnosus, celery concentrate (CP) (0.23% and 0.46%), and two doses of nitrate (70 and 140 mg/kg expressed as NaNO(3)) on residual nitrate and nitrite amounts, instrumental CIE Lab color, tocol content, oxidative stability, and overall acceptability were studied in fermented dry-cured sausages after ripening and after storage. Nitrate doses were provided by nitrate-rich CP or a chemical grade source. The lower dose complies with the EU requirements governing the maximum for ingoing amounts in organic meat products. Tocopherol addition protected against oxidation, whereas the nitrate dose, nitrate source, or starter culture had little influence on secondary oxidation values. The residual nitrate and nitrite amounts found in the sausages with the lower nitrate dose were within EU-permitted limits for organic meat products and residual nitrate can be further reduced by the presence of the S. carnosus culture. Color measurements were not affected by the CP dose. Product consumer acceptability was not affected negatively by any of the factors studied. As the two nitrate sources behaved similarly for the parameters studied, CP is a useful alternative to chemical ingredients for organic dry-cured sausage production.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a viscometric affinity biosensor that can potentially allow continuous multi-analyte monitoring in biological fluids like blood or plasma. The sensing principle is based on the detection of viscosity changes of a polymeric solution which has a selective affinity for the analyte of interest. The chemico-mechanical sensor incorporates an actuating piezoelectric diaphragm, a sensing piezoelectric diaphragm and a flow-resisting microchannel for viscosity detection. A free-standing Anodic Alumina Oxide (AAO) porous nano-membrane is used as selective interface. A glucose-sensitive sensor was fabricated and extensively assessed in buffer solution. The sensor reversibility, stability and sensitivity were excellent during at least 65 hours. Results showed also a good degree of stability for a long term measurement (25 days). The sensor behaviour was furthermore tested in fetal bovine serum (FBS). The obtained results for glucose sensing are very promising, indicating that the developed sensor is a candidate for continuous monitoring in biological fluids. Sensitive solutions for ionized calcium and pH are currently under development and should allow multi-analyte sensing in the near future.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Background: Aerosol-mediated delivery of nano-based therapeutics to the lung has emerged as a promising alternative for treatment and prevention of lung diseases. Superparamagnetic iron oxide nanoparticles (SPIONs) have attracted significant attention for such applications due to their biocompatibility and magnetic properties. However, information is lacking about the characteristics of nebulized SPIONs for use as a therapeutic aerosol. To address this need, we conducted a physicochemical characterization of nebulized Rienso, a SPION-based formulation for intravenous treatment of anemia. Methods: Four different concentrations of SPION suspensions were nebulized with a one-jet nebulizer. Particle size was measured in suspension by transmission electron microscopy (TEM), photon correlation spectroscopy (PCS), and nanoparticle tracking analysis (NTA), and in the aerosol by a scanning mobility particle sizer (SMPS). Results: The average particle size in suspension as measured by TEM, PCS, and NTA was 9±2 nm, 27±7 nm, and 56±10 nm, respectively. The particle size in suspension remained the same before and after the nebulization process. However, after aerosol collection in an impinger, the suspended particle size increased to 159±46 nm as measured by NTA. The aerosol particle concentration increased linearly with increasing suspension concentration, and the aerodynamic diameter remained relatively stable at around 75 nm as measured by SMPS. Conclusions: We demonstrated that the total number and particle size in the aerosol were modulated as a function of the initial concentration in the nebulizer. The data obtained mark the first known independent characterization of nebulized Rienso and, as such, provide critical information on the behavior of Rienso nanoparticles in an aerosol. The data obtained in this study add new knowledge to the existing body of literature on potential applications of SPION suspensions as inhaled aerosol therapeutics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Engineered nanomaterials (ENMs) exhibit special physicochemical properties and thus are finding their way into an increasing number of industries, enabling products with improved properties. Their increased use brings a greater likelihood of exposure to the nanoparticles (NPs) that could be released during the life cycle of nano-abled products. The field of nanotoxicology has emerged as a consequence of the development of these novel materials, and it has gained ever more attention due to the urgent need to gather information on exposure to them and to understand the potential hazards they engender. However, current studies on nanotoxicity tend to focus on pristine ENMs, and they use these toxicity results to generalize risk assessments on human exposure to NPs. ENMs released into the environment can interact with their surroundings, change characteristics and exhibit toxicity effects distinct from those of pristine ENMs. Furthermore, NPs' large surface areas provide extra-large potential interfaces, thus promoting more significant interactions between NPs and other co-existing species. In such processes, other species can attach to a NP's surface and modify its surface functionality, in addition to the toxicity in normally exhibits. One particular occupational health scenario involves NPs and low-volatile organic compounds (LVOC), a common type of pollutant existing around many potential sources of NPs. LVOC can coat a NP's surface and then dominate its toxicity. One important mechanism in nanotoxicology is the creation of reactive oxygen species (ROS) on a NP's surface; LVOC can modify the production of these ROS. In summary, nanotoxicity research should not be limited to the toxicity of pristine NPs, nor use their toxicity to evaluate the health effects of exposure to environmental NPs. Instead, the interactions which NPs have with other environmental species should also be considered and researched. The potential health effects of exposure to NPs should be derived from these real world NPs with characteristics modified by the environment and their distinct toxicity. Failure to suitably address toxicity results could lead to an inappropriate treatment of nano- release, affect the environment and public health and put a blemish on the development of sustainable nanotechnologies as a whole. The main objective of this thesis is to demonstrate a process for coating NP surfaces with LVOC using a well-controlled laboratory design and, with regard to these NPs' capacity to generate ROS, explore the consequences of changing particle toxicity. The dynamic coating system developed yielded stable and replicable coating performance, simulating an important realistic scenario. Clear changes in the size distribution of airborne NPs were observed using a scanning mobility particle sizer, were confirmed using both liquid nanotracking analyses and transmission electron microscopy (TEM) imaging, and were verified thanks to the LVOC coating. Coating thicknesses corresponded to the amount of coating material used and were controlled using the parameters of the LVOC generator. The capacity of pristine silver NPs (Ag NPs) to generate ROS was reduced when they were given a passive coating of inert paraffin: this coating blocked the reactive zones on the particle surfaces. In contrast, a coating of active reduced-anthraquinone contributed to redox reactions and generated ROS itself, despite the fact that ROS generation due to oxidation by Ag NPs themselves was quenched. Further objectives of this thesis included development of ROS methodology and the analysis of ROS case studies. Since the capacity of NPs to create ROS is an important effect in nanotoxicity, we attempted to refine and standardize the use of 2'7-dichlorodihydrofluorescin (DCFH) as a chemical tailored for the characterization of NPs' capacity for ROS generation. Previous studies had reported a wide variety of results, which were due to a number of insufficiently well controlled factors. We therefore cross-compared chemicals and concentrations, explored ways of dispersing NP samples in liquid solutions, identified sources of contradictions in the literature and investigated ways of reducing artificial results. The most robust results were obtained by sonicating an optimal sample of NPs in a DCFH-HRP solution made of 5,M DCFH and 0.5 unit/ml horseradish peroxidase (HRP). Our findings explained how the major reasons for previously conflicting results were the different experimental approaches used and the potential artifacts appearing when using high sample concentrations. Applying our advanced DCFH protocol with other physicochemical characterizations and biological analyses, we conducted several case studies, characterizing aerosols and NP samples. Exposure to aged brake wear dust engenders a risk of potential deleterious health effects in occupational scenarios. We performed microscopy and elemental analyses, as well as ROS measurements, with acellular and cellular DCFH assays. TEM images revealed samples to be heterogeneous mixtures with few particles in the nano-scale. Metallic and non-metallic elements were identified, primarily iron, carbon and oxygen. Moderate amounts of ROS were detected in the cell-free fluorescent tests; however, exposed cells were not dramatically activated. In addition to their highly aged state due to oxidation, the reason aged brake wear samples caused less oxidative stress than fresh brake wear samples may be because of their larger size and thus smaller relative reactive surface area. Other case studies involving welding fumes and differently charged NPs confirmed the performance of our DCFH assay and found ROS generation linked to varying characteristics, especially the surface functionality of the samples. Les nanomatériaux manufacturés (ENM) présentent des propriétés physico-chimiques particulières et ont donc trouvés des applications dans un nombre croissant de secteurs, permettant de réaliser des produits ayant des propriétés améliorées. Leur utilisation accrue engendre un plus grand risque pour les êtres humains d'être exposés à des nanoparticules (NP) qui sont libérées au long de leur cycle de vie. En conséquence, la nanotoxicologie a émergé et gagné de plus en plus d'attention dû à la nécessité de recueillir les renseignements nécessaires sur l'exposition et les risques associés à ces nouveaux matériaux. Cependant, les études actuelles sur la nanotoxicité ont tendance à se concentrer sur les ENM et utiliser ces résultats toxicologiques pour généraliser l'évaluation des risques sur l'exposition humaine aux NP. Les ENM libérés dans l'environnement peuvent interagir avec l'environnement, changeant leurs caractéristiques, et montrer des effets de toxicité distincts par rapport aux ENM originaux. Par ailleurs, la grande surface des NP fournit une grande interface avec l'extérieur, favorisant les interactions entre les NP et les autres espèces présentes. Dans ce processus, d'autres espèces peuvent s'attacher à la surface des NP et modifier leur fonctionnalité de surface ainsi que leur toxicité. Un scénario d'exposition professionnel particulier implique à la fois des NP et des composés organiques peu volatils (LVOC), un type commun de polluant associé à de nombreuses sources de NP. Les LVOC peuvent se déposer sur la surface des NP et donc dominer la toxicité globale de la particule. Un mécanisme important en nanotoxicologie est la création d'espèces réactives d'oxygène (ROS) sur la surface des particules, et les LVOC peuvent modifier cette production de ROS. En résumé, la recherche en nanotoxicité ne devrait pas être limitée à la toxicité des ENM originaux, ni utiliser leur toxicité pour évaluer les effets sur la santé de l'exposition aux NP de l'environnement; mais les interactions que les NP ont avec d'autres espèces environnementales doivent être envisagées et étudiées. Les effets possibles sur la santé de l'exposition aux NP devraient être dérivés de ces NP aux caractéristiques modifiées et à la toxicité distincte. L'utilisation de résultats de toxicité inappropriés peut conduire à une mauvaise prise en charge de l'exposition aux NP, de détériorer l'environnement et la santé publique et d'entraver le développement durable des industries de la nanotechnologie dans leur ensemble. L'objectif principal de cette thèse est de démontrer le processus de déposition des LVOC sur la surface des NP en utilisant un environnement de laboratoire bien contrôlé et d'explorer les conséquences du changement de toxicité des particules sur leur capacité à générer des ROS. Le système de déposition dynamique développé a abouti à des performances de revêtement stables et reproductibles, en simulant des scénarios réalistes importants. Des changements clairs dans la distribution de taille des NP en suspension ont été observés par spectrométrie de mobilité électrique des particules, confirmé à la fois par la méthode dite liquid nanotracking analysis et par microscopie électronique à transmission (MET), et a été vérifié comme provenant du revêtement par LVOC. La correspondance entre l'épaisseur de revêtement et la quantité de matériau de revêtement disponible a été démontré et a pu être contrôlé par les paramètres du générateur de LVOC. La génération de ROS dû aux NP d'argent (Ag NP) a été diminuée par un revêtement passif de paraffine inerte bloquant les zones réactives à la surface des particules. Au contraire, le revêtement actif d'anthraquinone réduit a contribué aux réactions redox et a généré des ROS, même lorsque la production de ROS par oxydation des Ag NP avec l'oxygène a été désactivé. Les objectifs associés comprennent le développement de la méthodologie et des études de cas spécifique aux ROS. Etant donné que la capacité des NP à générer des ROS contribue grandement à la nanotoxicité, nous avons tenté de définir un standard pour l'utilisation de 27- dichlorodihydrofluorescine (DCFH) adapté pour caractériser la génération de ROS par les NP. Des etudes antérieures ont rapporté une grande variété de résultats différents, ce qui était dû à un contrôle insuffisant des plusieurs facteurs. Nous avons donc comparé les produits chimiques et les concentrations utilisés, exploré les moyens de dispersion des échantillons HP en solution liquide, investigué les sources de conflits identifiées dans les littératures et étudié les moyens de réduire les résultats artificiels. De très bon résultats ont été obtenus par sonication d'une quantité optimale d'échantillons de NP en solution dans du DCFH-HRP, fait de 5 nM de DCFH et de 0,5 unité/ml de Peroxydase de raifort (HRP). Notre étude a démontré que les principales raisons causant les conflits entre les études précédemment conduites dans la littérature étaient dues aux différentes approches expérimentales et à des artefacts potentiels dus à des concentrations élevées de NP dans les échantillons. Utilisant notre protocole DCFH avancé avec d'autres caractérisations physico-chimiques et analyses biologiques, nous avons mené plusieurs études de cas, caractérisant les échantillons d'aérosols et les NP. La vielle poussière de frein en particulier présente un risque élevé d'exposition dans les scénarios professionnels, avec des effets potentiels néfastes sur la santé. Nous avons effectué des analyses d'éléments et de microscopie ainsi que la mesure de ROS avec DCFH cellulaire et acellulaire. Les résultats de MET ont révélé que les échantillons se présentent sous la forme de mélanges de particules hétérogènes, desquels une faible proportion se trouve dans l'échelle nano. Des éléments métalliques et non métalliques ont été identifiés, principalement du fer, du carbone et de l'oxygène. Une quantité modérée de ROS a été détectée dans le test fluorescent acellulaire; cependant les cellules exposées n'ont pas été très fortement activées. La raison pour laquelle les échantillons de vielle poussière de frein causent un stress oxydatif inférieur par rapport à la poussière de frein nouvelle peut-être à cause de leur plus grande taille engendrant une surface réactive proportionnellement plus petite, ainsi que leur état d'oxydation avancé diminuant la réactivité. D'autres études de cas sur les fumées de soudage et sur des NP différemment chargées ont confirmé la performance de notre test DCFH et ont trouvé que la génération de ROS est liée à certaines caractéristiques, notamment la fonctionnalité de surface des échantillons.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The attachment of Escherichia coli ATCC 25922 and Staphylococcus aureus ATCC 28213 onto six different materials used to manufacture dental implant abutments was quantitatively determined after 2 and 24 h of contact between the materials and the bacterial cultures. The materials were topographically characterized and their wettability determined, with both parameters subsequently related to bacterial adhesion. Atomic force microscopy, interferometry, and contact angle measurement were used to characterize the materials" surfaces. The results showed that neither roughness nor nano-roughness greatly influenced bacterial attachment whereas wettability strongly correlated with adhesion. After 2 h the degree of E. coli attachment markedly differed depending on the material whereas similar differences were not observed for S. aureus, which yielded consistently higher counts of adhered cells. Nevertheless, after 24 h the adhesion of the two species to the different test materials no longer significantly differed, although on all surfaces the numbers of finally adhered E. coli were higher than those of S. aureus

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article describes a photocatalytic nanostructured anatase coating deposited by cold gas spray (CGS)supported on titanium sub-oxide (TiO22x) coatings obtained by atmospheric plasma spray (APS) onto stainless steel cylinders. The photocatalytic coating was homogeneous and preserved the composition and nanostructure of the starting powder. The inner titanium sub-oxide coating favored the deposition of anatase particles in the solid state. Agglomerated nano-TiO2 particles fragmented when impacting onto the hard surface of the APS TiO22x bond coat. The rough surface provided by APS provided an ideal scenario for entrapping the nanostructured particles, which may be adhered onto the bond coat due to chemical bonding; a possible bonding mechanism is described. Photocatalytic experiments showed that CGS nano-TiO2 coating was active for photodegrading phenol and formic acid under aqueous conditions. The results were similar to the performance obtained by competitor technologies and materials such as dip-coating P25 photocatalysts. Disparity in the final performance of the photoactive materials may have been caused by differences in grain size and the crystalline composition of titanium dioxide.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of the thesis was to study fundamental structural and optical properties of InAs islands and In(Ga)As quantum rings. The research was carried out at the Department of Micro and Nanosciences of Helsinki University of Technology. A good surface quality can be essential for the potential applications in optoelectronic devices. For such device applications it is usually necessary to control size, density and arrangement of the islands. In order to study the dependence of the structural properties of the islands and the quantum rings on growth conditions, atomic force microscope was used. Obtained results reveal that the size and the density of the In(Ga)As quantum rings strongly depend on the growth temperature, the annealing time and the thickness of the partial capping layer. From obtained results it is possible to conclude that to get round shape islands and high density one has to use growth temperature of 500 ̊C. In the case of formation of In(Ga)As quantum rings the effect of mobility anisotropy is observed that so the shape of the rings is not symmetric. To exclude this effect it is preferable to use a higher annealing temperature of 570 ̊C. Optical properties were characterized by PL spectroscopy. PL emission was observed from buried InAs quantum dots and In(Ga)As quantum rings grown with different annealing time and temperature and covered with a various thickness of the partial capping layer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the competence of nurse teachers, who are teaching nursing at polytechnic level in Finland. The following research questions were framed for the study: What kind of evaluation nurse teachers of their nursing competence, teaching skills, evaluation skills, personality factors and relationships with students. The data were collected by a questionnaire (A Tool for Evaluation of Requirements of Nurse Teacher, ERNT). The questionnaire regarded background factors and 20 statements divided in five categories. The five competence categories were: Nursing competence, Teaching skills, Evaluation skills, Personality factors and Relationships with students. The evaluation scale was a 5-point Likert-scale. The respondents were nurse teachers, teacher for emergency nursing, public health nurse and midwifery teachers from all polytechnics in Finland. Response rate to the questionnaire was 46 % (n=342). The data were analysed by using descriptive statistics. Mean scores and standard deviations for each item were calculated. Category scores were obtained by summing scores of all items within a category. The results of this study showed that nurse teacher evaluated their competence on a high level. Concerning the category Relationships with students (mean 4.61, standard deviation 0.71) they got the highest averages. The lowest scores were gained regarding the requirements associated with teaching skills (mean 4.30, standard deviation 0.82). Concerning a single question, the best score was achieved in ability to take students seriously (mean 4.66, standard deviation 0.71) and the lowest score was achieved for their guidance of students to advance in decision making (mean 4.15, Std 0.69). The nurse teachers evaluated themselves with relatively high scores concerning competence categories as a hole. In future it is important to study nurse teacher competence with students or authorities of health service.