954 resultados para frequency stabilization, ultra trace analysis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Geometry optimization and harmonic vibrational frequency calculations have been performed on the (X) over bar (2)A(1) state of NO2 and (X) over bar (1)A(1) state of NO2-. Franck-Condon analyses and spectral simulations were carried out on the NO2((X) over bar (2)A(1))-NO2-((X) over bar (1)A(1)) photo detachment process. In addition, the equilibrium geometry parameters, r(NO)= 1.248 +/- 0.005 Angstrom and angle(ONO) 116.8 +/- 0.5degrees, of the (X) over bar (1)A(1) state of NO2-, are derived by employing an iterative Franck-Condon analysis procedure in the spectral simulation. Our conclusions regarding the anion geometry suggest a reinterpretation of the results of Woo et al. (C) 2004 Published by Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A theoretical method to calculate multidimensional Franck-Condon factors including Duschinsky effects is described and used to simulate the photoelectron spectra of HCF- and CF2- radicals. Geometry optimization and harmonic vibrational frequency calculations have been performed on the (X) over tilde (1)A' state of HCF and (X) over tilde (2)A" state of HCF-, and (X) over tilde (1)A(1) state of CF2 and (X) over tilde B-2(1) state of CF2-. Franck-Condon analyses and spectral simulation were carried out on the first photoelectron band of HCF- and CF2- respectively. The theoretical spectra obtained by employing B3LYP/6-311 + G(2d,p) values are in excellent agreement with the observed ones. In addition, the equilibrium geometry parameters, R(CF) = 0.1475 +/- 0.0005 nm, of the (X) over tilde (2)A" state of HCF-, and r(FC) = 0.1425 +/- 0.0005 nm and angle(FCF) = 100.5 +/- 0.5degrees, of the (X) over tilde B-2(i) state of CF2-, are derived by employing an iterative Franck-Condon analysis procedure in the spectral simulation. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vibronic excitations of the tri-atomic molecule OClO (A(2)A(2)(nu(1), nu(2), nu(3)) <-- (XB1)-B-2 (0, 0, 0)) with weak and strong ultra-short laser fields are studied within full quantum wavepacket dynamics in hyperspherical coordinates. Different dynamics is observed following excitation with laser pulses of different intensities. With a strong laser pulse, many vibrational states are excited and a spatially more localised wavepacket arises. The numerical results show that the population of different vibrational states of the wavepacket on the excited potential energy surface is altered by the intensity of the laser pulse. The numerical results also suggest a related effect on the phase of the wavepacket. These interesting phenomena can be understood by an analysis of the corresponding results for two model diatomic molecules. The possible physical mechanisms of control of chemical processes using strong laser fields are discussed. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method for calibration of an audio-frequency (AF) ion trap mass spectrometer is described. The method is proposed to surmount the obstacle that there is a lack of a proper calibrant for mass spectrometers in the mass-to-charge ratio (m/z) range of 10(6) to 10(10). To calibrate such mass spectra, we determine the point of ejection, q(eject), on the stability diagram of the ion trap operated in a mass-selective axial instability mode. This is accomplished by measuring the radial secular frequencies (and therefore, the m/z value) of a single trapped particle using a light scattering method, followed by monitoring the action of particle ejection in real time to obtain the q(eject). A delayed ejection with q(eject) = 0.949 +/- 0.004 is found at a trap driving frequency of Ohm/2pi = 200-600Hz. Theoretical analysis for the origin of the delayed ejection indicates that the delay is predominantly resulted from the existence of multipole components in the fields due to trap imperfections. Inclusion of -3% of the octopole with respect to the basic quadrupole field can satisfactorily account for our observations. An m/z accuracy approaching 0.1% is attainable after proper calibration of the AF ion trap mass spectrometer. (Int J Mass Spectrom 214 (2002) 63-73) (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have found that a commonly used complexation and solvent extraction technique (using mixed dithiocarbamates/Freon/HNO3) does not always extract Cd, Co, Cu and Ni from estuarine samples with the same efficiency as from Milli-Q water. For samples collected from the Derwent Estuary (Australia), the reduced extraction efficiency only occurred for unfiltered samples, but low extraction efficiencies were also observed for a (filtered) riverine certified reference material (SLRS-3) suggesting that the effect may be widespread. We have not been able to identify the reason for the low extraction efficiency and, although it is strongly correlated with the presence of high concentrations of suspended solids, dissolved organic matter and particulate iron, we have no experimental evidence to directly link any of these parameters to the effect. It is possible that similar effects may occur in other techniques which rely on a preconcentration step prior to analysis and that some literature values of heavy metals in estuarine waters may be low. We propose a modification of the standard complexation/solvent extraction method which overcomes these difficulties without adding significantly to the time taken for analyses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new kind of bismuth film modified electrode to sensitively detect trace metal ions based on incorporating highly conductive ionic liquids 1-butyl-3-methyl-imidazolium hexafluorophosphate (BMIMPF6) in solid matrices at glassy carbon (GC) was investigated. Poly(sodium 4-styrenesulfonate) (PSS), silica, and Nafion were selected as the solid matrices. The electrochemical properties of the mixed films modified GC were evaluated. The electron transfer rate of Fe(CN)(6)(4-)/Fe(CN)(6)(3-) can be effectively improved at the PSS-BMIMPF6 modified GC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lamellar platelets of triblock copolymers grown in dilute toluene solution with trace amounts of water can be used as templates for tethered diblock copolymer chain preparation and analysis. Polystyrene-bpoly(2-vinylpyridine)-b-poly(ethylene oxide) (PS-b-P2VP-b-PEO) with two different block fractions were used as model templates to generate tethered P2VP-b-PS chains on the platelet basal surfaces. In toluene solution the aggregation states of PS-b-P2VP-b-PEO were sensitive to the water content in the solution. For toluene with trace amount of water, spherical micelles were formed in the early stage and large square platelets would gradually grow from these spherical micelles. The hydrogen bonding between water and EO units was responsible for the formation of micelles and subsequent square platelets in the solution. Tethered P2VP-b-PS chains on basal surface of PEO platelets could be regarded as diblock copolymer brushes and the density (or: 0.086-0.36) and height (d: 3.5-14.3 nm) of these tethered chains could be easily modulated by changing the crystallization condition and/ or the molecular weight of each block. The tethered P2VP-b-PS chains were responsive to different solvent vapor.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fast analysis of ofloxacin and lidocaine, as bactericide and analgesic or anesthetics, is of clinic importance for understanding the patient's medical process. This paper presented a high throughput, simple analysis method of lidocaine and ofloxacin by capillary electrophoresis coupled with electrochemiluminescence (ECL) using porous etched joint. To shorten the analysis time and to improve the analytical performance, a capillary with 10 cm in length was used as the separation channel. The cyclic voltammograms of Ru(bpy)(3)(2+) with different capillary length at same field strength showed that the porous etched joint eliminated the effect of electrophoretic current on the ECL detection. Following micro total analysis systems (muTAS), some advantages of which this approach has, the fabrication of channel in chip was not needed. Compared with capillary electrophoresis with 40-cm-long capillary, the high sample throughput and low zone broadening may be the main advantage of the present system. Under optimal condition, the detection limits of lidocaine and ofloxacin based on peak height were 3.0 x 10(-8) and 5.0 x 10(-7) mot L-1 and a 60 h(-1) of sampling frequency was obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent important applications of inductively coupled plasma mass spectrometry in biological samples analysis are reviewed. The sample preparation, sample introduction techniques, interference correction and typical applications are introduced in detail with 154 references.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrochemical quartz crystal microbalance (EQCM) technique was used to measure the ion transfer in redox processes in electroactive organic thin films, such as self-assembled monolayer (SAM) (4-pyridyl hydroquinone, abbr. 4PHQ), multilayer based on SAM and conducting polymer film (here poly-(3,4-ethylenedioxythiophene), abbr. PEDOT). A mechanism of mixed ion transfer is developed and presented. Analysis of mixed ion transfer during redox processes successfully elucidates the deviation of oscillation frequency of the quartz crystal from theoretical expectation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The charactesistics of two-dimension spectra obtained by inductively coupled plasma atomic emission spectrometry (ICP-AES) with charge injection detection (CID) in frequency domain were studied in the present paper. The measurement spectra were Fourier transformed and the frequency distribution of the spectra was obtained. Results showed that the spectra in frequency domain could he divided into two parts:high frequency and low frequency signals. The later stood for measurement spectra and the former for background and noises. However, the high frequecny signals could not be smoothed simply to reduce noises because the background was deteriorated even though the spectral signal did not change significantly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method for the analysis of mussel standard reference material by inductively coupled plasma atomic emission spectrometry( ICP-AES) and inductively coupled plasma mass spectrometry(ICP-MS) was developed. K, Na, Ca, Mg, P, Al, Fe, Zn, Mn and Sr were determined by ICP-AES and As, B, Cd, Co, Cr, Cu, Ga, Ge, Mn, Mo, Ni, Pb, Se, Sr, U and V by ICP-MS, The interference coefficients at the Mn-55, Se-78, Cu-63, Co-59, Ni-58, Ni-60, As-75, Se-77, V-51, Cr-53 and Cr-52 originating from polyatomic ion of the matrix elements (KO)-K-39-O-16, K-39(2), (ArNa)-Ar-40-Na-23, (CaO)-Ca-43-O-16, (CaO)-Ca-42-O-16, (CaO)-Ca-44-O-16, (PO2)-P-31-O-16, (ArCl)-Ar-40-Cl-35, (ArCl)-Ar-40-Cl-37, (ClO)-Cl-35-O-16, (ClO)-Cl-37-O-16 and (ArC)-Ar-40-C-12 were determined under the selected operation parameters. The major matrix elements, such as K, Na and Ca, result in the suppression of analytes signals. The apparent concentration at the significant biological element which was produced by the different digestion methods, (.) HNO3 + H2O2 (3 + 2), HNO3 + HClO4 (3 + 0.5) and HNO3 + H2SO4 (3 + 0.5),was determined. The sample digested by HNO3 + H2O2 did not give rise to interfere on the analyte, and the backgrounds of Se-77, Ga-69, Zn-67, As-75, V-51, Cr-53 and Cr-52 were increased by HNO3 + HClO4 digestion method, that affected the determination of these elements, especially the monoisotope As and V. Sample digested by HNO3 + H2SO4 increased the backgrounds at Cu-65, Zn-64 and Zn-67. Detection limits of ICP-AES are 0.001 similar to 0.75 mg/L and those of ICP-MS are 0.005 similar to 1.01 mu g/L. The relative standard derivations of ICP-AES and ICP-MS are 2.7% similar to 12.8%, 3.4% similar to 24.8%, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel and quantitative study on structure-property relationships has been carried out in urea crystal, based on the dielectric theory of complex crystals and the modified Levine bond charge model, mainly from the chemical bond viewpoint. For the first time, it was treated like this, and the bond parameters and linear and nonlinear characteristics of constituent chemical bonds were presented quantitatively. The theoretical result agrees satisfactorily with the experimental datum and can reasonably explain the nonlinear origin of urea crystal, that is, the C-N bond in the conjugated system of bonds O double left arrow C<--N-H. At the same time, the novel method should be a useful tool toward the future development of the search for new nonlinear optical (NLO) materials in the organic crystal field.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method of analysis of high purity yttrium oxide with ICP-AES was described with emphasis on the study of Y_2O_3 matrix effects. The results showed that the line intensities of ana]ytes decreased with the increase of Y_2O_3 concentration in solution because of following factors. (1) The presence of matrix resulted in the decrease of the amount of analytes reaching ICP. (2) Matrix Y_2O_3 entering the plasma decreased the excitation temperature of the plasma and depressed the ionization of analytes in the pl...