853 resultados para femur subtrochanteric fracture


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nursing Case Management has motivated nurses to examine the effects of care provided to patients, and to devise means of improving this care. The success of this nursing care delivery model is well documented among a variety of acute and chronically ill patients. Utilizing nonparametric ANOVA for comparison of two means, this study investigates the outcome of the implementation of a nursingcase management model on an orthopedic unit of a local hospital. A convenience sample (N=149) of hip-fracture patients for two separate eight months charting periods were used. The first period was pre-case management and the second period was after the implementation of nursing managed care on the unit. Results suggested that nursing case management was effective in reducing the total length of hospital stay and post-operative days significantly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aluminum oxide (A1203, or alumina) is a conventional ceramic known for applications such as wear resistant coatings, thermal liners, heaters, crucibles, dielectric systems, etc. However applications of A1203 are limited owing to its inherent brittleness. Due to its excellent mechanical properties and bending strength, carbon nanotubes (CNT) is an ideal reinforcement for A1203 matrix to improve its fracture toughness. The role of CNT dispersion in the fracture toughening of the plasma sprayed A1203-CNT nanocomposite coating is discussed in the current work. Pretreatment of powder feedstock is required for dispersing CNTs in the matrix. Four coatings namely spray dried A1203 (A-SD), A1203 blended with 4wt.% CNT (A4C-B), composite spray dried A1203-4wt.% CNT (A4C-SD) and composite spray dried A1203-8wt.% CNT (A8CSD), are synthesized by plasma spraying. Owing to extreme temperatures and velocities involved in the plasma spraying of ceramics, retention of CNTs in the resulting coatings necessitates optimizing plasma processing parameters using an inflight particle diagnostic sensor. A bimodal microstructure was obtained in the matrix that consists of fully melted and resolidified structure and solid state sintered structure. CNTs are retained both in the fully melted region and solid-state sintered regions of processed coatings. Fracture toughness of A-SD, A4C-B, A4C-SD and A8C-SD coatings was 3.22, 3.86, 4.60 and 5.04 MPa m1/2 respectively. This affirms the improvement of fracture toughness from 20 % (in A4C-B coating) to 43% (in A4C-SD coating) when compared to the A-SD coating because of the CNT dispersion. Fracture toughness improvement from 43 % (in A4C-SD) to 57% (in A8C-SD) coating is evinced because of the CNT content. Reinforcement by CNTs is described by its bridging, anchoring, hook formation, impact alignment, fusion with splat, and mesh formation. The A1203/CNT interface is critical in assisting the stress transfer and utilizing excellent mechanical properties of CNTs. Mathematical and computational modeling using ab-initio principle is applied to understand the wetting behavior at the A1203/CNTinterface. Contrasting storage modulus was obtained by nanoindentation (~ 210, 250, 250-350 and 325-420 GPa in A-SD, A4C-B, A4C-SD, and A8C-SD coatings respectively) depicting the toughening associated with CNT content and dispersion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Pelvic rami fractures in the elderly are associated with significant morbidity and mortality. Despite our rapidly aging population there is a paucity of literature dealing with fractures of the pelvic rami in this age group. The purpose of this study is report mortality rates following these injuries in the Eastern region of Newfoundland. Additionally, we aim to describe and quantify the important resultant morbidity in this vulnerable elderly population . Methods: A retrospective chart review was performed of all the pelvic fractures in individuals over the age of 60 between 2000 and 2005 in the Eastern Health region of Newfoundland and Labrador. From these patients, only those with the radiographic parameters consistent with low energy pattern pelvic ring injuries were included. Excluded from the study were those with concurrent fractures of the femur. Survival data, comorbidities, injury characteristics, hospital stay, ambulatory status, and place of residence were recorded from the chart. A surrogate control group was formulated from Statistics Canada survival data for use as a survival comparison group. Results: There were 80 fractures of the pelvis identified in patients over 60 years old from 2000-2005. Of these, 43 met our inclusion/exclusion criteria and were used in our analysis. The one and five year mortalities of these patients were 16.3% (95% CI; 7.80% to 30.3%) and 58.1% (95% CI; 43.3% to 71.6%), respectively. These were both significantly different from the point estimates from our constructed age and gender matched control group from the Statistics Canada data of 6.58% (one year mortality) and 31.3% (five year mortality). Morbidity was quantified by change in ambulatory status (independent, walker/cane assisted, wheelchair) and change in residential independence (independent, assisted living, nursing home). Post fracture, 36% of patients permanently required increased ambulatory aids and 21% of patients required a permanent increase in everyday level of care. Conclusion: This study suggests that there may be significantly increased mortality and morbidity following low energy pattern pelvic rami fractures in an elderly population compared to age and gender matched controls. In contrast to previous studies describing these injuries, there is greater homogeneity in this population with respect to age and mechanism of injury. This study generates several important hypotheses for future research and in particular highlights the need for larger prospective studies to identify factors predicting the highest risk for poor outcomes in this population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New data on lithology and stratigraphy of Cenozoic sediments from the Clarion Transform Fault Zone (Pacific Ocean) have been obtained on the base of polygon studies. It has been established that on different blocks (uplifted and subsided) of the Clarion tectonic structure deposits of different age (Eocene to Quaternary) occur. Unconsolidated sediments have been deposited under pelagic conditions since Eocene (probably, since Early Cretaceous) until now. Their mineral composition and content of different ore components are given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We would like to thank the study participants and the clinical and research staff at the Queen Elizabeth National Spinal Injury Unit, as without them this study would not have been possible. We are grateful for the funding received from Glasgow Research Partnership in Engineering for the employment of SC during data collection for this study. We would like to thank the Royal Society of Edinburgh's Scottish Crucible scheme for providing the opportunity for this collaboration to occur. We are also indebted to Maria Dumitrascuta for her time and effort in producing inter-repeatability results for the shape models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We would like to thank the study participants and the clinical and research staff at the Queen Elizabeth National Spinal Injury Unit, as without them this study would not have been possible. We are grateful for the funding received from Glasgow Research Partnership in Engineering for the employment of SC during data collection for this study. We would like to thank the Royal Society of Edinburgh's Scottish Crucible scheme for providing the opportunity for this collaboration to occur. We are also indebted to Maria Dumitrascuta for her time and effort in producing inter-repeatability results for the shape models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peer reviewed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acknowledgements The authors thank the Ministry of Natural Resources in Iraqi Kurdistan Region for permission to publish this paper. Gulf Keystone Petroleum Ltd. and HKN Energy Ltd. are acknowledged for providing the subsurface datasets. Great thanks to Colin Taylor at the University of Aberdeen for his assistance in the laboratory work. Thoughtful reviews by two anonymous referees improved the clarity of the paper. Graham Banks is thanked for his helpful and constructive review on a late version of the manuscript, which has significantly improved this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acknowledgements We thank all the participants who took part, the research fellows (Kate Taylor, Robert Caslake, David McGhee, Angus Macleod) and nurses (Clare Harris, Joanna Gordon, Anne Hayman, Hazel Forbes) who helped assess the participants, and the study secretaries (Susan Kilpatrick, Pam Rebecca) and data management team (Katie Wilde, David Ritchie). The PINE study was funded by the BMA Doris Hillier award, Parkinson's UK, the RS McDonald Trust, NHS Grampian Endowments, SPRING and the BUPA Foundation. None of the funders had any influence in the study design, the collection, analysis and interpretation of the data, the writing of the report or the decision to submit the article for publication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peer reviewed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The focus of this work is to develop and employ numerical methods that provide characterization of granular microstructures, dynamic fragmentation of brittle materials, and dynamic fracture of three-dimensional bodies.

We first propose the fabric tensor formalism to describe the structure and evolution of lithium-ion electrode microstructure during the calendaring process. Fabric tensors are directional measures of particulate assemblies based on inter-particle connectivity, relating to the structural and transport properties of the electrode. Applying this technique to X-ray computed tomography of cathode microstructure, we show that fabric tensors capture the evolution of the inter-particle contact distribution and are therefore good measures for the internal state of and electronic transport within the electrode.

We then shift focus to the development and analysis of fracture models within finite element simulations. A difficult problem to characterize in the realm of fracture modeling is that of fragmentation, wherein brittle materials subjected to a uniform tensile loading break apart into a large number of smaller pieces. We explore the effect of numerical precision in the results of dynamic fragmentation simulations using the cohesive element approach on a one-dimensional domain. By introducing random and non-random field variations, we discern that round-off error plays a significant role in establishing a mesh-convergent solution for uniform fragmentation problems. Further, by using differing magnitudes of randomized material properties and mesh discretizations, we find that employing randomness can improve convergence behavior and provide a computational savings.

The Thick Level-Set model is implemented to describe brittle media undergoing dynamic fragmentation as an alternative to the cohesive element approach. This non-local damage model features a level-set function that defines the extent and severity of degradation and uses a length scale to limit the damage gradient. In terms of energy dissipated by fracture and mean fragment size, we find that the proposed model reproduces the rate-dependent observations of analytical approaches, cohesive element simulations, and experimental studies.

Lastly, the Thick Level-Set model is implemented in three dimensions to describe the dynamic failure of brittle media, such as the active material particles in the battery cathode during manufacturing. The proposed model matches expected behavior from physical experiments, analytical approaches, and numerical models, and mesh convergence is established. We find that the use of an asymmetrical damage model to represent tensile damage is important to producing the expected results for brittle fracture problems.

The impact of this work is that designers of lithium-ion battery components can employ the numerical methods presented herein to analyze the evolving electrode microstructure during manufacturing, operational, and extraordinary loadings. This allows for enhanced designs and manufacturing methods that advance the state of battery technology. Further, these numerical tools have applicability in a broad range of fields, from geotechnical analysis to ice-sheet modeling to armor design to hydraulic fracturing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Fractured neck of femur is a common cause of hospital admission in the elderly and usually requires operative fixation. In a variety of clinical settings, preoperative glucocorticoid administration has improved analgesia and decreased opioid consumption. Our objective was to define the postoperative analgesic efficacy of single dose of dexamethasone administered preoperatively in patients undergoing operative fixation of fractured neck of femur. Methods: Institutional ethical approval was granted and written informed consent was obtained from each patient. Patients awaiting for surgery at Cork University Hospital were recruited between July 2009 and August 2012. Participating patients, scheduled for surgery were randomly allocated to one of two groups (Dexamethasone or Placebo). Patients in the dexamethasone group received a single dose of intravenous dexamethasone 0.1 mg kg -1 immediately preoperatively. Patients in the placebo group received the same volume of normal saline. Patients underwent operative fixation of fractured neck of femur using standardised spinal anaesthesia and surgical techniques. The primary outcome was pain scores at rest 6 h after the surgery. Results: Thirty seven patients were recruited and data from thirty patients were analysed. The groups were similar in terms of patient characteristics. Pain scores at rest 6 h after the surgery (the principal outcome) were lesser in the dexamethasone group compared with the placebo group [0.8(1.3) vs. 3.9(2.9), mean(SD) p = 0.0004]. Cumulative morphine consumption 24 h after the surgery was also lesser in the dexamethasone group [7.7(8.3) vs. 15.1(9.4), mean(SD) mg, p = 0.04]. Conclusions: A single dose of intravenous dexamethasone 0.1 mg kg -1 administered before operative fixation of fractured neck of femur improve significantly the early postoperative analgesia. Trial registration: ClinicalTrials.gov identifier: NCT01550146, date of registration: 07/03/2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.