999 resultados para dengue transmission


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cooperative transmission can be seen as a "virtual" MIMO system, where themultiple transmit antennas are in fact implemented distributed by the antennas both at the source and the relay terminal. Depending on the system design, diversity/multiplexing gainsare achievable. This design involves the definition of the type of retransmission (incrementalredundancy, repetition coding), the design of the distributed space-time codes, the errorcorrecting scheme, the operation of the relay (decode&forward or amplify&forward) and thenumber of antennas at each terminal. Proposed schemes are evaluated in different conditionsin combination with forward error correcting codes (FEC), both for linear and near-optimum(sphere decoder) receivers, for its possible implementation in downlink high speed packetservices of cellular networks. Results show the benefits of coded cooperation over directtransmission in terms of increased throughput. It is shown that multiplexing gains areobserved even if the mobile station features a single antenna, provided that cell wide reuse of the relay radio resource is possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human nares are the main niche of Staphylococcus aureus, but farm animals can be also infected (cows) or colonized (pigs) constituting significant reservoir of this pathogen. Previous studies indicated that human and animal strains are quite distinct but the extent of cross-species specialization and transmission remains largely unknown. However, recent reports from several European countries as well as USA and Canada have indicated that employment in farming is an emerging risk factor for MRSA carriage. Pigs were found to be frequently colonized with MRSA, usually with a strain belonging to CC398. It is not known whether animal-human transmission was specific to this particular MRSA strain. S. aureus isolates from cow mastitis and pig colonization isolates were collected in parallel to nasal swab isolates from the animals' caretakers. The isolates were genotyped by AFLP, spatyping, and when appropriate by MLST. The isolates from cow mastitis were genetically uniform in comparison with human isolates. They were quite distinct from farmers\' carriage isolates, indicating pronounced hostspecialization. However, several cases where an infected cow and a colonized farmer had the same strain were detected, including one farm where two farmers were colonized and two cows were infected with MRSA belonging to CC398. Pig isolates were genetically more diverse than cow isolates. They were different from both human and cow isolates with one notable exception. Large fraction of pigs (20%) and pig caretakers (50%) were colonized with isolates belonging to CC398, majority of which were MSSA (2 cases of MRSA). These results indicate that host specialization in S. aureus is quite pronounced. Transmission between humans and farm animals was consequently quite rare. Both MSSA and MRSA strains belonging to otherwise pig-specific CC398 had increased capacity to colonize humans. Study of the genetic factors responsible for host specialization is underway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Kiristyville markkinoille on aina tuotava jotain uutta tarjottavaa ja SDH-kortti on yksi sellainen tuote jonka Nokia Networks julkistaa osaksi uutta Nokia Flexihub Nodea. Tavoitteena on suunnitella VC-12kanavoitu STM-1 kortti yhdistämään ylemmän tason tietoliikenneverkko suuren kapasiteetin radioon. Ennen kuin markkinoilla on valmis tuote, on sen takana valtaisa määrä työtä. Erilaisia dokumentteja on pitänyt tuottaa ja sopimuksia tehdä. Esimerkiksi vaatimusmäärittelyt on oltava selvät, jotta tiedetään mitä tuotteelta halutaan. Tätä ennen on kuitenkin pitänyt ymmärtää miten SDHtoimii ja miten otsikkotavuja käsitellään. Myös erilaiset piirivalinnat aiheuttavat miettimistä, sillä markkinoilla on runsaasti valmiita piirejä SDH signaalinkäsittelyyn. Varma tiedonsiirto on tärkeää puhelinoperaattorille ja siksi joudutaan miettimään varmennuksia ja niiden toteuttamista. Myös synkronointi on tärkeä osa SDH järjestelmää ja sen toteuttaminen hyvin on tärkeää. Hälytykset on otettava huomioon ja mietittävä, miten niiden käsittely saadaan hoidettua järkevästi, ilman että mikään järjestelmän osa ruuhkautuu kohtuuttomasti. Tässä Diplomityössä on tutustuttu SDH-järjestelmään, otsikkotavujen käsittelyyn ja vaatimusmäärittelyihin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dendritic cells (DCs) are essential in order to combat invading viruses and trigger antiviral responses. Paradoxically, in the case of HIV-1, DCs might contribute to viral pathogenesis through trans-infection, a mechanism that promotes viral capture and transmission to target cells, especially after DC maturation. In this review, we highlight recent evidence identifying sialyllactose-containing gangliosides in the viral membrane and the cellular lectin Siglec-1 as critical determinants for HIV-1 capture and storage by mature DCs and for DC-mediated trans-infection of T cells. In contrast, DC-SIGN, long considered to be the main receptor for DC capture of HIV-1, plays a minor role in mature DC-mediated HIV-1 capture and trans-infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The two independent components of the gyration tensor of quartz, g11 and g33, have been spectroscopically measured using a transmission two-modulator generalized ellipsometer. The method is used to determine the optical activity in crystals in directions other than the optic axis, where the linear birefringence is much larger than the optical activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this master's thesis a mechanical model that is driven with variable speed synchronous machine was developed. The developed mechanical model simulates the mechanics of power transmission and its torsional vibrations. The mechanical model was developed for the need of the branched mechanics of a rolling mill and the propulsion system of a tanker. First, the scope of the thesis was to clarify the concepts connected to the mechanical model. The clarified concepts are the variable speed drive, the mechanics of power transmission and the vibrationsin the power transmission. Next, the mechanical model with straight shaft line and twelve moments of inertia that existed in the beginning was developed to be branched considering the case of parallel machines and the case of parallel rolls. Additionally, the model was expanded for the need of moreaccurate simulation to up to thirty moments of inertia. The model was also enhanced to enable three phase short circuit situation of the simulated machine. After that the mechanical model was validated by comparing the results of the developed simulation tool to results of other simulation tools. The compared results are the natural frequencies and mode shapes of torsional vibration, the response of the load torque step and the stress in the mechanical system occurred by the permutation of the magnetic field that is arisen from the three phase short circuit situation. The comparisons were accomplished well and the mechanical model was validated for the compared cases. Further development to be made is to develop the load torque to be time-dependent and to install two frequency converters and two FEM modeled machines to be simulated parallel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The regulation of electricity transmission and distribution business is an essential issue for any electricity market; it is widely introduced in developed electricity markets of Great Britain, Scandinavian countries and United States of America and other. Those markets which were liberalized recently also need well planned regulation model to be chosen and implemented. In open electricity markets the sectors of electricity distribution and transmission remain monopolies, so called "natural monopolies", as introducing the competition into these sectors in most cases appears to be inefficient. Thatis why regulation becomes very important as its main tasks are: to set reasonable tariffs for customers, to ensure non-discriminating process of electricity transmission and distribution, at the same time to provide distribution companies with incentives to operate efficiently and the owners of the companies with reasonable profits as well; the problem of power quality should be solved at the same time. It should be mentioned also, that there is no incentive scheme which will be suitable for any conditions, that is why it is essential to study differentregulation models in order to form the best one for concrete situation. The aim of this Master's Thesis is to give an overview over theregulation of electricity transmission and distribution in Russia. First, the general information about theory of regulation of natural monopolies will be described; the situation in Russian network business and the importance of regulation process for it will be discussed next. Then there is a detailed description ofexisting regulatory system and the process of tariff calculation with an example. And finally, in the work there is a brief analysis of problems of present scheme of regulation, an attempt to predict the following development of regulationin Russia and the perspectives and risks connected to regulation which could face the companies that try to enter Russian electricity market (such as FORTUM OY).

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the electrical industry the 50 Hz electric and magnetic fields are often higher than in the average working environment. The electric and magnetic fields can be studied by measuring or by calculatingthe fields in the environment. For example, the electric field under a 400 kV power line is 1 to 10 kV/m, and the magnetic flux density is 1 to 15 µT. Electricand magnetic fields of a power line induce a weak electric field and electric currents in the exposed body. The average current density in a human being standing under a 400 kV line is 1 to 2 mA/m2. The aim of this study is to find out thepossible effects of short term exposure to electric and magnetic fields of electricity power transmission on workers' health, in particular the cardiovascular effects. The study consists of two parts; Experiment I: influence on extrasystoles, and Experiment II: influence on heart rate. In Experiment I two groups, 26 voluntary men (Group 1) and 27 transmission-line workers (Group 2), were measured. Their electrocardiogram (ECG) was recorded with an ambulatory recorder both in and outside the field. In Group 1 the fields were 1.7 to 4.9 kV/m and 1.1 to 7.1 pT; in Group 2 they were 0.1 to 10.2 kV/m and 1.0 to 15.4 pT. In the ECG analysis the only significant observation was a decrease in the heart rate after field exposure (Group 1). The drop cannot be explained with the first measuring method. Therefore Experiment II was carried out. In Experiment II two groups were used; Group 1 (26 male volunteers) were measured in real field exposure, Group 2 (15 male volunteers) in "sham" fields. The subjects of Group 1 spent 1 h outside the field, then 1 h in the field under a 400 kV transmission line, and then again 1 h outside the field. Under the 400 kV linethe field strength varied from 3.5 to 4.3 kV/m, and from 1.4 to 6.6 pT. Group 2spent the entire test period (3 h) in a 33 kV outdoor testing station in a "sham" field. ECG, blood pressure, and electroencephalogram (EEG) were measured by ambulatory methods. Before and after the field exposure, the subjects performed some cardiovascular autonomic function tests. The analysis of the results (Experiments I and II) showed that extrasystoles or arrythmias were as frequent in the field (below 4 kV/m and 4 pT) as outside it. In Experiment II there was no decrease detected in the heart rate, and the systolic and diastolic blood pressure stayed nearly the same. No health effects were found in this study.