898 resultados para control the coil voltage
Resumo:
Drugs and surgery can interfere with the biodistribution of radiopharmaceuticals and data about the effect of splenectomy on the metabolism of phytate-Tc-99m are scarce. This study aimed at evaluating the interference of splenectomy on phytate-Tc-99m biodistribution and liver function in rats. The SP group rats (n=6) underwent splenectomy. In group C (control) the animals were not operated on. After 15 days, all rats were injected with 0.1mL of Tc-99m-phytate via orbital plexus (0.66MBq). After 30 minutes, liver samples were harvested, weighed and the percentage of radioactivity per gram (%ATI-g) was determined by a Wizard Perkin-Elme gama counter. The ATI%-g in splenectomized rats (0.99±0.02) was significantly higher than in controls (0.4±0.02), (p=0.034). ALT, AST and HDL were significantly lower in SP rats (p= 0.001) and leukocytosis was observed in SP rats. In conclusion, splenectomy in rats changed the hepatic biodistribution of Tc-99m-phytate and liver enzimatic activity
Resumo:
In this work we isolated a novel crotamine like protein from the Crotalus durissus cascavella venom by combination of molecular exclusion and analytical reverse phase HPLC. Its primary structure was:YKRCHKKGGHCFPKEKICLPPSSDLGKMDCRWKRK-CCKKGS GK. This protein showed a molecular mass of 4892.89 da that was determined by Matrix Assisted Laser Desorption Ionization Time-of-flight (MALDI-TOF) mass spectrometry. The approximately pI value of this protein was determined in 9.9 by two-dimensional electrophoresis. This crotamine-like protein isolated here and that named as Cro 2 produced skeletal muscle spasm and spastic paralysis in mice similarly to other crotamines like proteins. Cro 2 did not modify the insulin secretion at low glucose concentration (2.8 and 5.6 mM), but at high glucose concentration (16.7 mM) we observed an insulin secretion increasing of 2.7-3.0-fold than to control. The Na+ channel antagonist tetrodoxin (6 mM) decreased glucose and Cro 2-induced insulin secretion. These results suggested that Na+ channel are involved in the insulin secretion. In this article, we also purified some peptide fragment from the treatment of reduced and carboxymethylated Cro 2 (RC-Cro 2) with cyanogen bromide and protease V8 from Staphylococcus aureus. The isolated pancreatic beta-cells were then treated with peptides only at high glucose concentration (16.7 mM), in this condition only two peptides induced insulin secretion. The amino acid sequence homology analysis of the whole crotamine as well as the biologically-active peptide allowed determining the consensus region of the biologically-active crotamine responsible for insulin secretion was KGGHCFPKE and DCRWKWKCCKKGSG.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Herbicidas aplicados ao solo são submetidos à adsorção, lixiviação e degradação por processos físicos, químicos e biológicos, além da absorção pelas plantas. Todos esses processos são afetados pela classe dos solos onde foram aplicados e das condições climáticas reinantes logo após a aplicação, que afetarão a eficiência dos produtos no controle de plantas daninhas. Investigaram-se as influências dos atributos de solos e condições de cultivo na eficiência do herbicida sulfentrazone no controle da planta daninha tiririca (Cyperus rotundus L.). O Latossolo Vermelho-Amarelo Distrófico (LVAd), o Latossolo Vermelho (LVd - Distrófico; LVdf - Distroférrico; LVef - Eutroférrico) e o Nitossolo Vermelho Eutrófico (NVe) foram coletados sob duas condições de cultivo, visando obter solos com teores diferenciados de argila, óxido de ferro e matéria orgânica. As amostras dos solos foram submetidas à caracterização granulométrica, química e mineralógica e, em seguida, utilizadas no bioensaio de avaliação da eficiência do sulfentrazone (1,6 L p.c. ha-1) no controle da tiririca em condições de pré-emergência. O sulfentrazone apresentou comportamento diferenciado entre as classes de solos estudados e a sua eficiência diminuiu com o aumento do teor de óxido de ferro nos solos, na seguinte ordem: LVAd, LVd, NVe, LVef e LVdf, sendo que as variações nos teores de argila (240 a 640 g kg-1) e da matéria orgânica (12 a 78 g kg-1) dos solos não interferiram na eficiência do sulfentrazone.
Resumo:
A distribuição espacial das espécies de cigarrinhas (Dilobopterus costalimai Young, Acrogonia sp. e Oncometopia facialis Signoret), vetoras da Xylella fastidiosa, agente causal da Clorose Variegada dos Citros, foi estudada com o uso da geoestatística. As avaliações foram feitas em um pomar comercial de laranja 'Pêra' (Citrus sinensis [L.] Osb.), objetivando estabelecer meios para melhor controle dos vetores e da doença. O monitoramento da ocorrência das cigarrinhas no pomar foi feito através de amostragens mensais, utilizando-se armadilhas adesivas amarelas de 3 x 5, distribuídas uniformemente em 50 pontos na área, dispostas em laranjeiras à altura de 1,5 m do solo e substituídas mensalmente. Acrogonia sp. foi a espécie prevalente nas amostragens. Os resultados possibilitaram ajustar modelos aos semivariogramas da distribuição espacial das três espécies no pomar estudado. Durante os três anos consecutivos de amostragem, as populações de Acrogonia sp., D. costalimai e O. facialis apresentaram modelos de distribuição agregada somente nos meses de verão, inverno e primavera, respectivamente, mostrando a necessidade de monitoramento constante desses vetores para reduzir a sua população em épocas favoráveis ao seu desenvolvimento. Através de parâmetros geoestatísticos foi possível calcular a área de agregação das cigarrinhas no pomar. A espécie Acrogonia sp. apresentou área média de agregação de 15.760 m², enquanto para O. facialis e D. costalimai foi possível constatar áreas médias de agregação de 11.555 m² e 10.980 m², respectivamente. Esses resultados indicaram que para um levantamento seguro de cigarrinhas é necessário pelo menos dispor de uma armadilha por hectare.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The citrus leprosis control in São Paulo state is performed exclusively by acaricides to control the vector mite, Brevipalpus phoenicis, which increases the production costs and may affect the beneficial organism's population. Therefore, the aim of this trial was to evaluate during four seasons, the effects of acaricides recommended to control the mite B. phoenicis in conventional and organic citrus over evolution of citrus leprosis and over phytoseiids' population. The experiment was installed in October of 2003 in a citrus orchard in Reginopolis city, state of São Paulo. The experimental design used randomized blocks, the dosages was expressed as mL c.p./100L of water and the treatments were the following: spirodiclofen (20 mL); cyhexatin (50 mL) (used in rotation), lime sulfur (4,000 mL) and control (without pesticide application). However, the rotation between spirodiclofen and cyhexatin began in September 2006. Prior to that time, only spirodiclofen had been used. Surveys were conducted every 15 days on the B. phoenicis, Iphiseioides zuluagai, and Euseius populations. The control level adopted by the B. phoenicis was 8.3%, and the pesticide applications were conducted using tractor-sprayers. During the 2007-08 seasons, 10 infected fallen fruits per plot were collected and the number of leprosis lesions was quantified by each fruit. By the end of the 2007-08 seasons, the productivity, harvest losses, the disease incidence and severity were evaluated. It was found that the lesions' location over the fruit is more important in determining its drop than the lesions' number. The more intense the mite infestation, the greater is the number of lesions, resulting in increased premature fruit drop. A strategy using acaricides spirodiclofen and cyhexatin in rotation promoted more efficient control of B. phoenicis compared to lime sulfur, resulting in greater productivity, lower fruit losses and severity levels. The lime sulfur applications reduced the mite population incidence below the control level; however it did not prevent the lesions' occurrence. The acaricides applicarevented adverse effects on phytoseiid population because there was a reduction of their density.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS-APPC). In the VS-APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system
Resumo:
The aim of this study was to develop a laboratory method for time response evaluation on electronically controlled spray equipment using Programmable Logic Controllers (PLCs). For that purpose, a PLC controlled digital drive inverter was set up to drive an asynchronous electric motor linked to a centrifugal pump on a experimental sprayer equipped with electronic flow control. The PLC was operated via RS232 serial communication from a PC computer. A user program was written to control de motor by adjusting the following system variables, all related to the motor speed: time stopped; ramp up and ramp down times, time running at a given constant speed and ramp down time to stop the motor. This set up was used in conjunction with a data acquisition system to perform laboratory tests with an electronically controlled sprayer. Time response for pressure stabilization was measured while changing the pump speed by +/-20%. The results showed that for a 0.2 s ramp time increasing the motor speed, as an example, an AgLogix Flow Control system (Midwest Technologies Inc.) took 22 s in average to readjust the pressure. When decreasing the motor speed, this time response was down to 8 s. General results also showed that this kind of methodology could make easier the definition of standards for tests on electronically controlled application equipment.
Resumo:
This work deals with the development of an experimental study on a power supply of high frequency that provides the toch plasmica to be implemented in PLASPETRO project, which consists of two static converters developed by using Insulated Gate Bipolar Transistor (IGBT). The drivers used to control these keys are triggered by Digital Signal Processor (DSP) through optical fibers to reduce problems with electromagnetic interference (EMI). The first stage consists of a pre-regulator in the form of an AC to DC converter with three-phase boost power factor correction which is the main theme of this work, while the second is the source of high frequency itself. A series-resonant inverter consists of four (4) cell inverters operating in a frequency around 115 kHz each one in soft switching mode, alternating itself to supply the load (plasma torch) an alternating current with a frequency of 450 kHz. The first stage has the function of providing the series-resonant inverter a DC voltage, with the value controlled from the power supply provided by the electrical system of the utility, and correct the power factor of the system as a whole. This level of DC bus voltage at the output of the first stage will be used to control the power transferred by the inverter to the load, and it may vary from 550 VDC to a maximum of 800 VDC. To control the voltage level of DC bus driver used a proportional integral (PI) controller and to achieve the unity power factor it was used two other proportional integral currents controllers. Computational simulations were performed to assist in sizing and forecasting performance. All the control and communications needed to stage supervisory were implemented on a DSP
Resumo:
Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS¡APPC). In the VS¡APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system
Resumo:
A ferrugem asiática da soja, causada pelo fungo Phakopsora pachyrhizi, é considerada a principal doença da soja, e, portanto, a escolha e o uso adequado dos equipamentos de pulverização são essenciais para seu controle. O objetivo deste trabalho foi avaliar o desempenho de diferentes equipamentos de pulverização aérea para o controle curativo da ferrugem da soja, utilizando o fungicida Impact 125 SC (flutriafol) a 0,5 L p c ha-1. Os seguintes tratamentos foram avaliados: atomizador Micronair AU 5000 (10 L ha-1 com óleo e 20 L ha-1 sem óleo na calda); atomizador Stol ARD (10 e 20 L ha-1 ambos com óleo) e o sistema eletrostático Spectrum (10 L ha-1 sem óleo a 64 e 71% de umidade relativa). Utilizou-se óleo de algodão (1,0 L ha-1) acrescido de emulsificante BR 455 a 0,025 L ha-1. O ensaio foi realizado na terceira aplicação de fungicidas, quando foram analisadas quatro repetições nas áreas aplicadas e quatro testemunhas não aplicadas para cada tratamento, avaliando-se a severidade da ferrugem, os depósitos de flutriafol nas folhas de soja e o percentual de redução de ferrugem. A análise dos depósitos nas folhas mostrou que não houve diferenças significativas entre os tratamentos. Os melhores controles da ferrugem foram obtidos com os tratamentos Micronair (10 L ha-1 com óleo), Stol (20 L ha-1 com óleo) e o sistema elestrostático (10 L ha-1) com a menor umidade relativa do ar (64 %).
Resumo:
The stability of synchronous generators connected to power grid has been the object of study and research for years. The interest in this matter is justified by the fact that much of the electricity produced worldwide is obtained with the use of synchronous generators. In this respect, studies have been proposed using conventional and unconventional control techniques such as fuzzy logic, neural networks, and adaptive controllers to increase the stabilitymargin of the systemduring sudden failures and transient disturbances. Thismaster thesis presents a robust unconventional control strategy for maintaining the stability of power systems and regulation of output voltage of synchronous generators connected to the grid. The proposed control strategy comprises the integration of a sliding surface with a linear controller. This control structure is designed to prevent the power system losing synchronism after a sudden failure and regulation of the terminal voltage of the generator after the fault. The feasibility of the proposed control strategy was experimentally tested in a salient pole synchronous generator of 5 kVA in a laboratory structure
Effect of estradiol benzoate microinjection into the median raphe nucleus on contextual conditioning
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)