898 resultados para central composite rotatable design


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Excess nutrient loads carried by streams and rivers are a great concern for environmental resource managers. In agricultural regions, excess loads are transported downstream to receiving water bodies, potentially causing algal blooms, which could lead to numerous ecological problems. To better understand nutrient load transport, and to develop appropriate water management plans, it is important to have accurate estimates of annual nutrient loads. This study used a Monte Carlo sub-sampling method and error-corrected statistical models to estimate annual nitrate-N loads from two watersheds in central Illinois. The performance of three load estimation methods (the seven-parameter log-linear model, the ratio estimator, and the flow-weighted averaging estimator) applied at one-, two-, four-, six-, and eight-week sampling frequencies were compared. Five error correction techniques; the existing composite method, and four new error correction techniques developed in this study; were applied to each combination of sampling frequency and load estimation method. On average, the most accurate error reduction technique, (proportional rectangular) resulted in 15% and 30% more accurate load estimates when compared to the most accurate uncorrected load estimation method (ratio estimator) for the two watersheds. Using error correction methods, it is possible to design more cost-effective monitoring plans by achieving the same load estimation accuracy with fewer observations. Finally, the optimum combinations of monitoring threshold and sampling frequency that minimizes the number of samples required to achieve specified levels of accuracy in load estimation were determined. For one- to three-weeks sampling frequencies, combined threshold/fixed-interval monitoring approaches produced the best outcomes, while fixed-interval-only approaches produced the most accurate results for four- to eight-weeks sampling frequencies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aromatic thermosetting copolyester (ATSP) has promise in high-temperature applications. It can be employed as a bulk polymer, as a coating and as a matrix for carbon fiber composites (ATSP/C composites). This work focuses on the applications of high performance ATSP/C composites. The morphology of the ATSP matrix in the presence of carbon fiber was studied. The effect of liquid crystalline character of starting oligomers used to prepare ATSP on the final crystal structure of the ATSP/C composite was evaluated. Matrices obtained by crosslinking of both liquid crystalline oligomers (ATSP2) and non-liquid crystalline oligomers (ATSP1) tend to crystallize in presence of carbon fibers. The crystallite size of ATSP2 is 4 times that of ATSP1. Composites made from ATSP2 yield tougher matrices compared to those made from ATSP1. Thus toughened matrices could be achieved without incorporating any additives by just changing the morphology of the final polymer. The flammability characteristics of ATSP were also studied. The limiting oxygen index (LOI) of bulk ATSP was found to be 40% whereas that of ATSP/C composites is estimated to be 85%. Thus, ATSP shows potential to be used as a flame resistant material, and also as an aerospace reentry shield. Mechanical properties of the ATSP/C composite were characterized. ATSP was observed to bond strongly with reinforcing carbon fibers. The tensile strength, modulus and shear modulus were comparable to those of conventionally used high temperature epoxy resins. ATSP shows a unique capability for healing of interlaminar cracks on application of heat and pressure, via the Interchain Transesterification Reaction (ITR). ITR can also be used for reduction in void volume and healing of microcracks. Thus, ATSP resin systems provide a unique intrinsic repair mechanism compared to any other thermosetting systems in use today. Preliminary studies on measurement of residual stresses for ATSP/C composites indicate that the stresses induced are much lower than that in epoxy/C composites. Thermal fatigue testing suggests that ATSP shows better resistance to microcracking compared to epoxy resins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: This paper describes the results of a feasibility study for a randomised controlled trial (RCT). Methods: Twenty-nine members of the UK Dermatology Clinical Trials Network (UK DCTN) expressed an interest in recruiting for this study. Of these, 17 obtained full ethics and Research & Development (R&D) approval, and 15 successfully recruited patients into the study. A total of 70 participants with a diagnosis of cellulitis of the leg were enrolled over a 5-month period. These participants were largely recruited from medical admissions wards, although some were identified from dermatology, orthopaedic, geriatric and general surgery wards. Data were collected on patient demographics, clinical features and willingness to take part in a future RCT. Results: Despite being a relatively common condition, cellulitis patients were difficult to locate through our network of UK DCTN clinicians. This was largely because patients were rarely seen by dermatologists, and admissions were not co-ordinated centrally. In addition, the impact of the proposed exclusion criteria was high; only 26 (37%) of those enrolled in the study fulfilled all of the inclusion criteria for the subsequent RCT, and were willing to be randomised to treatment. Of the 70 participants identified during the study as having cellulitis of the leg (as confirmed by a dermatologist), only 59 (84%) had all 3 of the defining features of: i) erythema, ii) oedema, and iii) warmth with acute pain/tenderness upon examination. Twenty-two (32%) patients experienced a previous episode of cellulitis within the last 3 years. The median time to recurrence (estimated as the time since the most recent previous attack) was 205 days (95% CI 102 to 308). Service users were generally supportive of the trial, although several expressed concerns about taking antibiotics for lengthy periods, and felt that multiple morbidity/old age would limit entry into a 3-year study. Conclusion: This pilot study has been crucial in highlighting some key issues for the conduct of a future RCT. As a result of these findings, changes have been made to i) the planned recruitment strategy, ii) the proposed inclusion criteria and ii) the definition of cellulitis for use in the future trial.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Local anesthetic agents cause temporary blockade of nerve impulses productiong insensitivity to painful stimuli in the area supplied by that nerve. Bupivacaine (BVC) is an amide-type local anesthetic widely used in surgery and obstetrics for sustained peripheral and central nerve blockade. in this study, we prepared and characterized nanosphere formulations containing BVC. To achieve these goals, BVC loaded poly(DL-lactide-co-glycolide) (PLGA) nanospheres (NS) were prepared by nanopreciptation and characterized with regard to size distribution, drug loading and cytotoxicity assays. The 2(3-1) factorial experimental design was used to study the influence of three different independent variables on nanoparticle drug loading. BVC was assayed by HPLC, the particle size and zeta potential were determined by dynamic light scattering. BVC was determined using a combined ultrafiltration-centrifugation technique. The results of optimized formulations showed a narrow size distribution with a polydispersivity of 0.05%, an average diameter of 236.7 +/- 2.6 nm and the zeta potential -2.93 +/- 1,10 mV. In toxicity studies with fibroblast 3T3 cells, BVC loaded-PLGA-NS increased cell viability, in comparison with the effect produced by free BVC. In this way, BVC-loaded PLGA-NS decreased BVC toxicity. The development of BVC formulations in carriers such as nanospheres could offer the possibility of controlling drug delivery in biological systems, prolonging the anesthetic effect and reducing toxicity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Determination of Rare Earth Elements (REEs) in the waters and sediments of El Hito Lake and its drainage basin was carried out. Distribution maps for REEs concentrations show increasing values in the lake sediments from the center to the eastern edge reaching 166.5 mg/kg. In the drainage basin, higher values were observed with a maximum of 350.9 mg/kg in the southern part. Concentrations in the water were considerably lower with a maximum value of 1.3 µg/L. Ce, La and Nd were the most abundant elements. When normalized REE concentrations against NASC (North American Shale Composite), a positive anomaly of Eu in the water and of Nd in the sediments (lake and basin) was observed. The (La/Gd)NASC and (La/Yb)NASC ratios determined the predominance of light REE (LREE) over medium (MREE) and heavy REE (HREE). Key-words: Rare Earth Elements, lacustrine sediments and water, Eu anomaly, sulfates RESUMEN: Se llevó a cabo el estudio de Tierras Raras (REEs) del agua y los sedimentos de la Laguna de El Hito así como de su cuenca de recepción. Los mapas de distribución de las concentraciones de REE en los sedimentos de la laguna mostraron valores crecientes desde el centro hacia el margen este alcanzando 166.5 mg/kg. En la cuenca se midieron valores más elevados llegando hasta 350.9 mg/kg en la mitad sur. Los valores en el agua fueron notablemente inferiores, con un máximo de 1.3 µg/L. El elemento más abundante fue el Ce seguido del Nd. Se normalizaron las concentraciones de REEs frente a las del NASC (North American Shale Composite), observándose una anomalía positiva de Eu en el agua, así como de Nd en los sedimentos (laguna y cuenca). Mediante los índices (La/Gd)NASC y (La/Yb)NASC se determinó el predominio de las REEs ligeras (LREEs) frente a las medias (MREE) y pesadas (HREE).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To investigate the effect of implant-abutment angulation and crown material on stress distribution of central incisors. Finite element method was used to simulate the clinical situation of a maxillary right central incisor restored by two different implant-abutment angulations, 15° and 25°, using two different crown materials (IPS E-Max CAD and zirconia). Methods: Two 3D finite element models were specially prepared for this research simulating the abutment angulations. Commercial engineering CAD/CAM package was used to model crown, implant abutment complex and bone (cortical and spongy) in 3D. Linear static analysis was performed by applying a 178 N oblique load. The obtained results were compared with former experimental results. Results: Implant Von Mises stress level was negligibly changed with increasing abutment angulation. The abutment with higher angulation is mechanically weaker and expected to fail at lower loading in comparison with the steeper one. Similarly, screw used with abutment angulation of 25° will fail at lower (about one-third) load value the failure load of similar screw used with abutment angulated by 15°. Conclusions: Bone (cortical and spongy) is insensitive to crown material. Increasing abutment angulation from 15° to 25°, increases stress on cortical bone by about 20% and reduces it by about 12% on spongy bone. Crown fracture resistance is dramatically reduced by increasing abutment angulation. Zirconia crown showed better performance than E-Max one.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new design route is proposed in order to fabricate aluminum matrix diamond-containing composite materials with optimized values of thermal conductivity (TC) for thermal management applications. The proper size ratio and proportions of particulate diamond–diamond and diamond–SiC bimodal mixtures are selected based on calculations with predictive schemes, which combine two main issues: (i) the volume fraction of the packed particulate mixtures, and (ii) the influence of different types of particulates (with intrinsically different metal/reinforcement interfacial thermal conductances) on the overall thermal conductivity of the composite material. The calculated results are validated by comparison with measurements on composites fabricated by gas pressure infiltration of aluminum into preforms of selected compositions of particle mixtures. Despite the relatively low quality (low price) of the diamond particles used in this work, outstanding values of TC are encountered: a maximum of 770 W/m K for Al/diamond–diamond and values up to 690 W/m K for Al/diamond–SiC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent developments in micro- and nanoscale 3D fabrication techniques have enabled the creation of materials with a controllable nanoarchitecture that can have structural features spanning 5 orders of magnitude from tens of nanometers to millimeters. These fabrication methods in conjunction with nanomaterial processing techniques permit a nearly unbounded design space through which new combinations of nanomaterials and architecture can be realized. In the course of this work, we designed, fabricated, and mechanically analyzed a wide range of nanoarchitected materials in the form of nanolattices made from polymer, composite, and hollow ceramic beams. Using a combination of two-photon lithography and atomic layer deposition, we fabricated samples with periodic and hierarchical architectures spanning densities over 4 orders of magnitude from ρ=0.3-300kg/m3 and with features as small as 5nm. Uniaxial compression and cyclic loading tests performed on different nanolattice topologies revealed a range of novel mechanical properties: the constituent nanoceramics used here have size-enhanced strengths that approach the theoretical limit of materials strength; hollow aluminum oxide (Al2O3) nanolattices exhibited ductile-like deformation and recovered nearly completely after compression to 50% strain when their wall thicknesses were reduced below 20nm due to the activation of shell buckling; hierarchical nanolattices exhibited enhanced recoverability and a near linear scaling of strength and stiffness with relative density, with E∝ρ1.04 and σy∝ρ1.17 for hollow Al2O3 samples; periodic rigid and non-rigid nanolattice topologies were tested and showed a nearly uniform scaling of strength and stiffness with relative density, marking a significant deviation from traditional theories on “bending” and “stretching” dominated cellular solids; and the mechanical behavior across all topologies was highly tunable and was observed to strongly correlate with the slenderness λ and the wall thickness-to-radius ratio t/a of the beams. These results demonstrate the potential of nanoarchitected materials to create new highly tunable mechanical metamaterials with previously unattainable properties.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are few regulatory restrictions involving the use of fully autonomous unmanned aerial systems in unpopulated, farming areas of Australia. The combination of a fully autonomous aerial and ground systems would provide efficient and cost effective retrieval of soil and vegetation data for use in precision agriculture. The aerial system will survey the site and collect spectral imagery to analyse plant density, stress and nutrition. The ground sensors will collect soil moisture content readings throughout the site. The data from both systems will be collated at a central base station. The base station will also provide housing and interface with the aerial system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper addresses an issue that has been omnipresent in the history of CAAD research: the tension between scientific method and the design discipline in which it operates. Outside the CAAD community, research through design is been undertaken by a new generation. Through a discussion of research methodologies, a survey of CAAD activity and the examination of design projects, it is proposed that this provides a valuable opportunity to redress the balance between scientific and designerly modes of research and in so doing engage with a new generation of design computing researchers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Cardiac rehabilitation (CR) is a secondary prevention program that offers education and support to assist patients with coronary heart disease (CHD) make lifestyle changes. Despite the benefits of CR, attendance at centre-based sessions remains low. Mobile technology (mHealth) has potential to reach more patients by delivering CR directly to mobile phones, thus providing an alternative to centre-based CR. The aim of this trial is to evaluate if a mHealth comprehensive CR program can improve adherence to healthy lifestyle behaviours (for example, physically active, fruit and vegetable intake, not smoking, low alcohol consumption) over and above usual CR services in New Zealand adults diagnosed with CHD.

METHODS/DESIGN: A two-arm, parallel, randomised controlled trial will be conducted at two Auckland hospitals in New Zealand. One hundred twenty participants will be randomised to receive a 24-week evidence- and theory-based personalised text message program and access to a supporting website in addition to usual CR care or usual CR care alone (control). The primary outcome is the proportion of participants adhering to healthy behaviours at 6 months, measured using a composite health behaviour score. Secondary outcomes include overall cardiovascular disease risk, body composition, illness perceptions, self-efficacy, hospital anxiety/depression and medication adherence.

DISCUSSION: This study is one of the first to examine an mHealth-delivered comprehensive CR program. Strengths of the trial include quality research design and in-depth description of the intervention to aid replication. If effective, the trial has potential to augment standard CR practices and to be used as a model for other disease prevention or self-management programs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Childhood obesity has reached epidemic proportions in developed countries. Sedentary screen-based activities such as video gaming are thought to displace active behaviors and are independently associated with obesity. Active video games, where players physically interact with images onscreen, may have utility as a novel intervention to increase physical activity and improve body composition in children. The aim of the Electronic Games to Aid Motivation to Exercise (eGAME) study is to determine the effects of an active video game intervention over 6 months on: body mass index (BMI), percent body fat, waist circumference, cardio-respiratory fitness, and physical activity levels in overweight children.

METHODS/DESIGN: Three hundred and thirty participants aged 10-14 years will be randomized to receive either an active video game upgrade package or to a control group (no intervention).

DISCUSSION: An overview of the eGAME study is presented, providing an example of a large, pragmatic randomized controlled trial in a community setting. Reflection is offered on key issues encountered during the course of the study. In particular, investigation into the feasibility of the proposed intervention, as well as robust testing of proposed study procedures is a critical step prior to implementation of a large-scale trial.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel, solution-processable non-fullerene electron acceptor, 6,6′-((9-(heptadecan-9-yl)-9H-carbazole-2,7-diyl)bis(thiophene-5,2-diyl))bis(2,5-bis(2-ethylhexyl)-3-(thiophen-2-yl)-2,5-dihydropyrrolo[3,4-c]pyrrole-1,4-dione) (coded as N7), based on central carbazole and terminal diketopyrrolopyrrole building blocks was designed, synthesized and characterized. N7 displayed excellent solubility, thanks to its design allowing incorporation of numerous lipophilic chains, thermal stability, and afforded a 2.30% power conversion efficiency with a high open-circuit voltage (1.17 V) when tested with the conventional donor polymer poly(3-hexylthiophene) in solution-processable bulk-heterojunction devices. To our knowledge, not only is N7 the first reported chromophore based on carbazole and diketopyrrolopyrrole functionalities but the open-circuit voltage reported here is among the highest values for a single junction bulk-heterojunction device that has been fabricated using a simple device architecture, with reproducible outcomes and with no special treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An overview of the design and performance of geosynthetics in composite barrier systems for biopiles used to remediate hydrocarbon-contaminated soil at Casey Station, Antarctica, is presented. Seven instrumented biopiles were constructed over three field seasons. To minimize the risk of hydrocarbon migration to groundwater, composite barrier systems were used (each using different combinations of geosynthetic clay liners (GCLs), high density polyethylene (HDPE) geomembranes (GMB), and geotextiles (GTXs)). One biopile used a co-extruded geomembrane (HDPE with an ethylene vinyl alcohol (EVOH) core). The liner system was subject to a combination of coupled phenomena that could interact and affect the GMB-GCL composite barrier performance. The exposure conditions involved potential freeze-thaw cycling, hydration-desiccation cycles, cation exchange, direct and diffusive exposure to hydrocarbons. The effect of these phenomena was investigated by monitoring GCL and GMB sacrificial coupons. GCL coupons were placed between the main GCL component and the main geomembrane component of the composite liner and GMB coupons placed between the main GMB sheet and the GTX protection layer. Coupons were exhumed from the biopiles each year. The exhumed GCL field moisture content values ranged from 162% to 22%. After three (3) years in the field, GCL coupons that had undergone at least one hydration/desiccation cycle showed no significant change in swell index values or fluid loss values. The measured hydraulic conductivity of exhumed GCL coupons from Biopiles 1 and 2 (3 × 10-11 m s-1) was within the expected range and not significantly different from the values for virgin GCL. GMB coupons exhumed after three years from Biopiles 1 and 2 showed no significant change in oxidative induction time (OIT), melt flow index or tensile properties. Diffusion tests were performed as an index test for establishing the performance of the GMBs as a diffusive barrier to hydrocarbons, with permeation parameters for BTEX contaminants ranging from P g = 0.9-9.2 × 10-13 m2 s-1 for the exhumed GMB (with values depending on the contaminant and GMB). These values were similar to the parameters obtained for virgin GMBs and there was no significant change with field exposure, with GMBs appearing to be performing well.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports on a comparative study that evaluates two approaches to support the learning and use of algorithmic design in architecture, and extrapolates from this to consider applications for the algorithmic design of cities. The study explored two methods to reduce the barriers of using programming and potentially improve design performance. The first is the reuse of abstract algorithmic ‘patterns’. The second approach is the reuse of algorithmic solutions from specific design cases (case-based design). Reflecting on this research we outline how our findings discussed in relation to alternate thinking on the use of pattern, might inform a hybrid approach to the algorithmic design of cities.