912 resultados para analytical method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A calibration method was developed using flow injection analysis (FI) with a Gradient Calibration Method (GCM). The method allows the rapid determination of zinc In foods (approximately 30 min) after treatment with concentrated sulphuric acid and 30% hydrogen peroxide, and analysis with flame atomic absorption spectrometry (FAAS). The method provides analytical results with a relative standard deviation of about 2% and requires less time than by conventional FI calibration. The electronic selection of different segments along the gradient and monitoring of the technique covers wide concentration ranges while maintaining the inherent high precision of flow injection analysis. Concentrations, flow rates, and flow times of the reagents were optimized in order to obtain best accuracy and precision. Flow rates of 10 mL/min were selected for zinc. In addition, the system enables electronic dilution and calibration where a multipoint curve can be constructed using a single sample injection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A poly glutamic acid film modified electrode exhibited a catalytic response toguanosine oxidation potential and higher peak current value. Linear concentration curve was obtained in the concentration interval of 1.0 a 10.0 μmol L-1 in 0.04 mol L-1 B-R buffer pH 2.0 with a detection limit of 0.198 μmol L-1. The electrode was used for the determination of guanosine in the potential of +1.1 V (vs. Ag/AgCl) using differential pulse voltammetry (DPV) at urine sample with good recovery. © 2010 by CEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple method to determine Cu, Fe, Mn and Zn in single aliquots of medicinal plants by HR-CS FAAS is proposed. The main lines for Cu, Mn and Zn, and the alternate line measured at the wing of the main line for Fe at 248.327 nm allowed calibration within the 0.025 - 2.0 mg L-1 Cu, 1.0 - 20.0 mg L-1 Fe, 0.05 - 2.0 mg L-1 Mn, 0.025 - 0.75 mg L-1 Zn ranges. Nineteen medicinal plants and two certified plant reference materials were analyzed. Results were in agreement at a 95% confidence level (paired t-test) with reference values. Limits of detection were 0.12 μg L-1 Cu, 330 μg L-1 Fe, 1.42 μg L-1 Mn and 8.12 μg L-1 Zn. Relative standard deviations (n=12) were ≤ 3% for all analytes. Recoveries in the 89 - 105% (Cu), 95 - 108% (Fe), 94 - 107% (Mn), and 93 - 110% (Zn) ranges were obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes a simple, environmentally friendly and rapid quantitative spot test procedure for the determination of captopril (CPT) in bulk drug and in pharmaceutical formulations by using diffuse reflectance spectroscopy. The proposed method is based on the reflectance measurements of the orange compound (λ max 490 nm) produced by the spot test reaction between CPT and p-chloranil (CL). Under optimal conditions, calibration curves were obtained for CPT by plotting the optical density of the reflectance signal (A R) vs. the log of the mol L -1 concentration, from 6.91×10 -3 to 1.17×10 -1, with a good coefficient of determination (R 2 = 0.9992). The common excipients used as additives in pharmaceuticals do not interfere in the proposed method. The method was applied to determine CPT in commercial pharmaceutical formulations. The results obtained by the proposed method are compared favorably with those obtained by an official procedure at 95% confidence level. The method validation results showed that the sensitivity and selectivity of the methods were adequated for drug monitoring in industrial quality control laboratories. © 2011 Moment Publication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An analytical approach for spin stabilized attitude propagation is presented, considering the coupled effect of the aerodynamic torque and the gravity gradient torque. A spherical coordination system fixed in the satellite is used to locate the satellite spin axis in relation to the terrestrial equatorial system. The spin axis direction is specified by its right ascension and the declination angles and the equation of motion are described by these two angles and the magnitude of the spin velocity. An analytical averaging method is applied to obtain the mean torques over an orbital period. To compute the average components of both aerodynamic torque and the gravity gradient torque in the satellite body frame reference system, an average time in the fast varying orbit element, the mean anomaly, is utilized. Afterwards, the inclusion of such torques on the rotational motion differential equations of spin stabilized satellites yields conditions to derive an analytical solution. The pointing deviation evolution, that is, the deviation between the actual spin axis and the computed spin axis, is also availed. In order to validate the analytical approach, the theory developed has been applied for spin stabilized Brazilian satellite SCD1, which are quite appropriated for verification and comparison of the data generated and processed by the Satellite Control Center of the Brazil National Research Institute (INPE). Numerical simulations performed with data of Brazilian Satellite SCD1 show the period that the analytical solution can be used to the attitude propagation, within the dispersion range of the attitude determination system performance of Satellite Control Center of the Brazilian Research Institute.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lubricating oils are crucial in the operation of automotive engines because they both reduce friction between moving parts and protect against corrosion. However, the performance of lubricant oil may be affected by contaminants, such as gasoline, diesel, ethanol, water and ethylene glycol. Although there are many standard methods and studies related to the quantification of contaminants in lubricant oil, such as gasoline and diesel oil, to the best of our knowledge, no methods have been reported for the quantification of ethanol in used Otto cycle engine lubrication oils. Therefore, this work aimed at the development and validation of a routine method based on partial least-squares multivariate analysis combined with attenuated total reflectance in the mid-infrared region to quantify ethanol content in used lubrication oil. The method was validated based on its figures of merit (using the net analyte signal) as follows: limit of detection (0.049%), limit of quantification (0.16%), accuracy (root mean square error of prediction=0.089% w/w), repeatability (0.05% w/w), fit (R 2 =0.9997), mean selectivity (0.047), sensitivity (0.011), inverse analytical sensitivity (0.016% w/w-1) and signal-to-noise ratio (max: 812.4 and min: 200.9). The results show that the proposed method can be routinely implemented for the quality control of lubricant oils. © 2013 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The development of an electroanalytical method for simultaneous determination of copper and lead ions in sugar cane spirit (cachaça) using carbon paste electrode modified with ascorbic acid and carbon nanotubes (CPE-AaCNT) is described. Squarewave voltammetry (SWV) with anodic stripping was employed, and this technique was optimized with respect to the following parameters: frequency (50 Hz), amplitude (100 mV) and scan increment (9 mV). The analytical curves were linear in the range from 0.0900 to 7.00 mg L - 1 for lead and copper. The limits of detection were 48.5 and 23.9 µg L - 1 for lead and copper, respectively. The developed method was applied to the simultaneous determination of copper and lead in five commercial samples of sugar cane spirit. The results were in good agreement with those obtained by F AAS/GF AAS (flame atomic absorption spectrometry/graphite furnace atomic absorption spectrometry) and showed that CPE-AaCNT can be successfully employed in the simultaneous determination of these metals in real sugar cane spirit samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT: Analytical procedures for U-Pb isotope dilution analyses at the Pará-Iso isotope geology laboratory of the Federal University of Pará (UFPA) are described in detail. The procedures are applied to zircon, titanite, rutile, apatite, columbite-tantalite and whole rock. Reagent preparation and chemical processing are done in clean-room conditions. Samples are dissolved using Teflon™ microcapsules in steel jacket Teflon™ Parr Instrument™ bomb or Teflon™ screw cap containers. U and Pb are separated using anion exchange AG 1x8 resin columns. Typical blanks for mineral sample amounts of 0.01 to 1.0 mg are less than 1 pg U and 20-30 pg Pb. Isotope analysis of the U and Pb from the same filament are carried out using a Finnigan MAT 262 mass-spectrometer in static and dynamic modes. The current analytical level is demonstrated on analyses of international standard zircon 91500 with three different 235U-205Pb and 235U-208Pb isotope tracers and whole rock standards. Results of analyses of two zircon samples are also presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this letter, a methodology is proposed for automatically (and locally) obtaining the shape factor c for the Gaussian basis functions, for each support domain, in order to increase numerical precision and mainly to avoid matrix inversion impossibilities. The concept of calibration function is introduced, which is used for obtaining c. The methodology developed was applied for a 2-D numerical experiment, which results are compared to analytical solution. This comparison revels that the results associated to the developed methodology are very close to the analytical solution for the entire bandwidth of the excitation pulse. The proposed methodology is called in this work Local Shape Factor Calibration Method (LSFCM).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)