951 resultados para Yeast one-hybrid


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To evaluate the gene expression profile of fibroblasts from affected and non-affected skin of systemic sclerosis (SSc) patients and from controls. Materials and methods Labeled cDNA from fibroblast cultures from forearm (affected) and axillary (non-affected) skin from six diffuse SSc patients, from three normal controls, and from MOLT-4/HEp-2/normal fibroblasts (reference pool) was probed in microarrays generated with 4193 human cDNAs from the IMAGE Consortium. Microarray images were converted into numerical data and gene expression was calculated as the ratio between fibroblast cDNA (Cy5) and reference pool cDNA (Cy3) data and analyzed by R environment/Aroma, Cluster, Tree View, and SAM softwares. Differential expression was confirmed by real time PCR for a set of selected genes. Results Eighty-eight genes were up- and 241 genes down-regulated in SSc fibroblasts. Gene expression correlation was strong between affected and non-affected fibroblast samples from the same patient (r>0.8), moderate among fibroblasts from all patients (r=0.72) and among fibroblasts from all controls (r=0.70), and modest among fibroblasts from patients and controls (r=0.55). The differential expression was confirmed by real time PCR for all selected genes. Conclusions Fibroblasts from affected and non-affected skin of SSc patients shared a similar abnormal gene expression profile, suggesting that the widespread molecular disturbance in SSc fibroblasts is more sensitive than histological and clinical alterations. Novel molecular elements potentially involved in SSc pathogenesis were identified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Borges GR, Salgado HC, Silva CA, Rossi MA, Prado CM, Fazan R Jr. Changes in hemodynamic and neurohumoral control cause cardiac damage in one-kidney, one-clip hypertensive mice. Am J Physiol Regul Integr Comp Physiol 295: R1904-R1913, 2008. First published October 1, 2008; doi:10.1152/ajpregu.00107.2008.-Sympathovagal balance and baroreflex control of heart rate (HR) were evaluated during the development (1 and 4 wk) of one-kidney, one-clip (1K1C) hypertension in conscious mice. The development of cardiac hypertrophy and fibrosis was also examined. Overall variability of systolic arterial pressure (AP) and HR in the time domain and baroreflex sensitivity were calculated from basal recordings. Methyl atropine and propranolol allowed the evaluation of the sympathovagal balance to the heart and the intrinsic HR. Staining of renal ANG II in the kidney and plasma renin activity (PRA) were also evaluated. One and four weeks after clipping, the mice were hypertensive and tachycardic, and they exhibited elevated sympathetic and reduced vagal tone. The intrinsic HR was elevated only 1 wk after clipping. Systolic AP variability was elevated, while HR variability and baroreflex sensitivity were reduced 1 and 4 wk after clipping. Renal ANG II staining and PRA were elevated only 1 wk after clipping. Concentric cardiac hypertrophy was observed at 1 and 4 wk, while cardiac fibrosis was observed only at 4 wk after clipping. In conclusion, these data further support previous findings in the literature and provide new features of neurohumoral changes during the development of 1K1C hypertension in mice. In addition, the 1K1C hypertensive model in mice can be an important tool for studies evaluating the role of specific genes relating to dependent and nondependent ANG II hypertension in transgenic mice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A plausible approach to evaluate the inhibitory action of antifungals is through the investigation of the fungal resistance to these drugs. We describe here the molecular cloning and initial characterization of the A. nidulans lipA gene, where mutation (lipA1) conferred resistance to undecanoic acid, the most fungitoxic fatty acid in the C(7:0)-C(18:0) series. The lipA gene codes for a putative lipase with the sequence consensus GVSIS and WIFGGG as the catalytic signature. Comparison of the wild-type and LIP1 mutant strain nucleotide sequences showed a G -> A change in lipA1 allele, which results in a Glu(214) -> Lys substitution in LipA protein. This ionic charge change in a conserved LipA region, next to its catalytic site, may have altered the catalytic properties of this enzyme resulting in resistance to undecanoic acid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Polycystic ovary syndrome (PCOS) is associated with adverse metabolic effects. Some cardiovascular disease (CVD) risk markers are increased in women with PCOS. However, early markers of atherosclerosis are also associated with obesity and insulin resistance, which are related to PCOS. These markers may result either directly from PCOS or indirectly as a consequence of the comorbidities associated with the syndrome. Context To assess the presence of early CVD markers in young, nonobese women with PCOS. Patients Forty women with PCOS and 50 healthy women with regular menstrual cycles, matched for age and body mass index (BMI). Measurements The following CVD markers were assessed by ultrasonography: common carotid artery (CCA) stiffness index (beta), distensibility and intima-media thickness (IMT), and brachial artery flow-mediated dilatation (FMD). Inflammatory markers, including interleukin (IL)-6, tumour necrosis factor (TNF)-alpha, homocysteine, C-reactive protein (CRP), glycaemia, lipid profile and insulin, were also assessed. Results CCA beta was higher in PCOS than in control women (3 center dot 72 +/- 0 center dot 96 vs. 3 center dot 36 +/- 0 center dot 96, P = 0 center dot 04) and CCA distensibility was lower (0 center dot 31 +/- 0 center dot 08 vs. 0 center dot 35 +/- 0 center dot 09 mmHg(-1), P = 0 center dot 02). Waist circumference, total testosterone and the Free Androgen Index (FAI) were higher in PCOS patients than in controls (78 center dot 2 +/- 10 center dot 0 vs. 71 center dot 5 +/- 7 center dot 2 cm, P = 0 center dot 001; 88 center dot 1 +/- 32 center dot 4 vs. 57 center dot 1 +/- 21 center dot 2 ng/dl, P < 0 center dot 01; 12 center dot 7 +/- 15 center dot 7%vs. 4 center dot 7 +/- 2 center dot 3%, P < 0 center dot 01, respectively), while SHBG was reduced (37 center dot 9 +/- 19 center dot 1 vs. 47 center dot 8 +/- 18 center dot 3 nmol/l, P = 0 center dot 01). The remaining variables did not differ between the groups. Conclusions Young women with PCOS exhibit changes in vascular elasticity even in the absence of classical risk factors for CVD, such as hypertension and obesity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effects of intravitreal bevacizumab in patients with diabetic macular edema (DME) associated with severe capillary loss. DESIGN: Multicenter, open-label, nonrandomized study. METHODS: SETTING: Two tertiary ophthalmic referral centers in Brazil. STUDY POPULATION: Ten consecutive patients with DME and ""severe"" capillary loss. OBSERVATION PROCEDURES: Intravitreal injection(s) of bevacizumab (1.5 mg). Standardized ophthalmic evaluation was performed at baseline and at weeks 8, 16, 24, and 54. MAIN OUTCOME MEASURES: Changes in best-corrected visual acuity (BCVA) and in optical coherence tomography variables (central macular thickness [CMT] and total macular volume [TMV]). RESULTS: Significant changes in BCVA and in CMT/TMV were noted throughout the study (P<.001, P=.009, and P<.001, respectively). The mean logarithm of the minimal angle of resolution Early Treatment Diabetic Retinopathy Study BCVA was 0.786 (similar to 20/125(+1)) at baseline, 0.646 (similar to 20/80(-2)) at week 8, 0.580 (20/80(+1)) at week 16, 0.574 (similar to 20/80(+1)) at week 24, and 0.558 (similar to 20/80(+2)) at week 54. Compared with baseline, a significant change in BCVA was noted at all follow-up visits (P <=.008). The mean CMT/TMV values were, respectively, 472.6/10.9 at baseline, 371.4/9.9 at week 8, 359.5/9.8 at week 16, 323.9/9-4 at week 24, and 274.6/8.7 at week 54. Compared with baseline, a significant change in both CMT and TMV was noted only at 24 and 54 weeks (P <=.007). At 54 weeks, fluorescein angiography demonstrated no change in the extent of macular capillary loss and reduced dye leakage as compared with baseline in all patients. CONCLUSIONS: Favorable changes in BCVA and in CMT/TMV observed throughout 1 year suggest that intra-vitreal bevacizumab may be a viable alternative treatment for the management of patients with DME and severe capillary loss. (Am J Ophthalmol 2009;147:1022-1030. (C) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present report describes an original surgical procedure for the mandibular reconstruction of 2 different defects using a single fibular flap. In addition to the habitual osteotomies, we resected a bone fragment from the middle portion of the flap, with care taken to maintain the integrity of the pedicle throughout its extension to guarantee an adequate blood supply also for the distal portion of the bone flap used for the treatment of the smaller mandibular defect. This simple maneuver permitted the reconstruction of 2 mandibular regions with well-vascularized bone tissue using a single microsurgical flap. (C) 2008 Published by Elsevier Inc.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Illegitimate V(D)J-recombination in lymphoid malignancies involves rearrangements in immunoglobulin or T-cell receptor genes, and these rearrangements may play a role in oncogenic events. High frequencies of TRGV-BJ hybrid gene (rearrangement between the TRB and TRG loci at 7q35 and 7p14-15, respectively) have been detected in lymphocytes from patients with ataxia telangiectasia (AT), and also in patients with lymphoid malignancies. Although the TRGV-BJ gene has been described only in T-lymphocytes, we previously detected the presence of TRGV-BJ hybrid gene in the genomic DNA extracted from SV40-transformed AT5BIVA fibroblasts from an AT patient. Aiming to determine whether the AT phenotype or the SV40 transformation could be responsible for the production of the hybrid gene by illegitimate V(D)J-recombination, DNA samples were extracted from primary and SV40-transformed (normal and AT) cell lines, following Nested-PCR with TRGV- and TRBJ-specific primers. The hybrid gene was only detected in SV40-transformed fibroblasts (AT-5BIVA and MRC-5). Sequence alignment of the cloned PCR products using the BLAST program confirmed that the fragments corresponded to the TRGV-BJ hybrid gene. The present results indicate that the rearrangement can be produced in nonlymphoid cells, probably as a consequence of the genomic instability caused by the SV40-transformation, and independently of ATM gene mutation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background-Fetal atrioventricular (AV) block is an uncommon lesion with significant mortality. Because of the rarity of this disorder, the natural course, extensive evaluation of untreated fetuses, and late follow-up remain unclear. Methods and Results-Of the 116 consecutive cases of fetal AV block studied from 1988 to 2006, only 1 was terminated, and 75% were live births. Fifty-nine cases of AV block were associated with major structural heart disease, mainly left atrial isomerism (n = 40), with only 26% of neonatal survivors. Of the 57 fetuses with normal cardiac anatomy, 41 (72%) were positive for maternal antinuclear antibodies, and 32 of these seropositive mothers did not receive any treatment. This untreated group had live-birth and 1-year infant survival rates of 93% and 90%, respectively. Five fetuses from seronegative mothers showed regression to sinus rhythm during pregnancy. The presence of major structural heart disease, hydrops, an atrial rate <= 120 bpm, and a ventricular rate <= 55 bpm were identified as risk factors for mortality. Logistic regression analysis of the whole group showed that the presence of structural heart disease was the only independent predictor of death (P < 0.001). Conclusions-This long-term study confirms that fetal AV block has a poor outcome when associated with structural heart disease and that spontaneous regression of AV block is possible in seronegative forms. The survival rate of >90% of our untreated patients with isolated forms of AV block raises concerns about any decision to intervene with immunosuppressive agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ten year official condemnation records of one officially inspected poultry abattoir in state of Sao Paulo. Brazil, were analyzed. Seasonal and cyclical trends were analyzed in relation to traumatic lesions and airsacculitis. which were the most relevant official condemnation causes Time series analysis of the records, seasonal indexes and moving averages was used to describe the adherence to the mathematical model and to offer preventive management strategies for the slaughter house industry Although cause-effect relationships were not defined, some insight was given into the causal mechanisms that generated the series (C) 2010 Elsevier B V All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vitro study aimed to determine whether the micro-hardness of a composite resin is modified by the light units or by the thickness of the increment. Composite resin disks were divided into 15 groups (n = 5), according to the factors under study: composite resin thickness (0 mm, 1 mm, 2 mm , 3 mm and 4 mm) and light units. The light activation was performed with halogen light (HL) (40 s, 500 mW/cm(2)), argon ion laser (AL) (30 s, 600 mW/cm(2)) or light-emitting diode (LED) (30 s, 400 mW/cm(2)). Vickers micro-hardness tests were performed after 1 week and were carried out on the top surface (0 mm-control) and at different depths of the samples. Analysis of variance (ANOVA) and Tukey tests (P a parts per thousand currency signaEuro parts per thousand 0.05) revealed no statistically significant difference among the light units for the groups of 0 mm and 1 mm thickness. At 2 mm depth, the AL was not statistically different from the HL, but the latter showed higher micro-hardness values than the LED. In groups with 3 mm and 4 mm thickness, the HL also showed higher micro-hardness values than the groups activated by the AL and the LED. Only the HL presented satisfactory polymerization with 3 mm of thickness. With a 4 mm increment no light unit was able to promote satisfactory polymerization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this in vitro study was to evaluate the microtensile bond strength (mu TBS) and hybrid layer morphology of different adhesive systems, either followed by treatment with Nd:YAG laser irradiation or not. Previous studies have shown the effects of Nd:YAG laser irradiation on the dentin surface at restoration margins, but there are few reports about the significance of the irradiation on the hybrid layer. Materials and Methods: The flattened coronal and root dentin samples of 24 bovine teeth were randomly divided into 8 groups, according to the adhesive system used - Scotchbond Multi Purpose (SBMP) or Clearfil SE Bond (CSEB) - and were either irradiated with Nd:YAG or not, with different parameters: 0.8 W/10 Hz, 0.8 W/20 Hz, 1.2 W/10 Hz, 1.2 W/20 Hz. The left sides of specimens were the control groups, and right sides were irradiated. A composite crown was built over bonded surfaces and stored in water (24 h at 37 degrees C). Specimens were sectioned vertically into slabs that were subjected to mu TBS testing and observed by SEM. Results: Control groups (27.81 +/- 1.38) showed statistically higher values than lased groups (21.37 +/- 0.99), and CSEB control group values (31.26 +/- 15.71) were statistically higher than those of SBMP (24.3 +/- 10.66). There were no significant differences between CSEB (20.34 +/- 10.01) and SBMP (22.43 +/- 9.82) lased groups. Among parameters tested, 0.8 W/10 Hz showed the highest value (25.54 +/- 11.74). Nd:YAG laser irradiation caused dentin to melt under the adhesive layer of both adhesive systems tested. Conclusion: With the parameters used in this study, Nd:YAG laser irradiation of the hybrid layer promoted morphological changes in dentin and negatively influenced the bond strength of both adhesive systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The aim of this study was to test the effect of adhesive temperature on the bond strength to dentin (mu TBS) and silver nitrate uptake (SNU) of an ethanol/water (Adper Single Bond 2 [SB]) and an acetone-based (Prime&Bond 2.1 [PB]) etch-and-rinse adhesive system. Methods: The bottles of each adhesive were kept in various temperatures (5 degrees C, 20 degrees C, 37 degrees C and 50 degrees C) for 1 h previously to its application in the occlusal demineralized dentin of 40 molars. Bonded sticks (0.8 mm(2)) were tested in tension (0.5 mm/min) immediately (IM) or after 6 months (6 M) of water storage. Two bonded sticks from each hemi-tooth were immersed in silver nitrate and analyzed by SEM. Data were analyzed by two-way repeated measures ANOVA and Tukey`s test (alpha = 0.05). Results: No significant difference in mu TBS was detected for both adhesives at 5 degrees C and 20 degrees C. The highest bond strength for PB was observed in the 37 degrees C group while for SB it was in the 50 degrees C. Significant reductions of bond strengths were observed for PB at 37 degrees C and SB at 50 degrees C after 6 M of water storage. Silver nitrate deposition was seen in all hybrid layers, irrespective of the group. Lower silver nitrate deposition (water trees) in the adhesive layer was seen for PB and SB at higher temperatures. Conclusions: The heating or refrigeration of the adhesives did not improve their resin-dentin bond resistance to water degradation over time. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study evaluated the immediate and 6-month resin-dentin mu-bond strength (mu TBS) of one-step self-etch systems (Adper Prompt L-Pop [AD] 3M ESPE; Xeno III [XE] Dentsply De Trey; iBond [iB] Heraeus Kulzer) under different application modes. Materials and methods: Dentin oclusal surfaces were exposed by grinding with 600-grit SiC paper. The adhesives were applied according to the manufacturer`s directions [MD], or with double application of the adhesive layer [DA] or following the manufacturer`s directions plus a hydrophobic resin layer coating [HL]. After applying the adhesive resins, composite crowns were built up incrementally. After 24-h water storage, the specimens were serially sectioned in ""x"" and ""y"" directions to obtain bonded sticks of about 0.8 mm 2 to be tested immediately [IM] or after 6 months of water storage [6M] at a crosshead speed of 0.5 mm/min. The data from each adhesive was analyzed by a two-way repeated measures ANOVA (mode of application vs. storage time) and Tukey`s test (alpha = 0.05). Results: The adhesives performed differently according to the application mode. The DA and HL either improved the immediate performance of the adhesive or did not differ from the MD. The resin-dentin bond strength values observed after 6 months were higher when a hydrophobic resin coat was used than compared to those values observed under the manufacturer`s directions. Conclusions: The double application of one-step self-etch system can be safety performed however the application of an additional hydrophobic resin layer can improve the immediate resin-dentin bonds and reduce the degradation of resin bonds over time. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To examine the effect of prolonged application time on the early and 3-year resin-dentin microtensile bond strength. Methods. Water/ethanol (Single Bond [SB]) and acetone-based systems (One Step [OS]) were employed. A flat superficial dentin surface was exposed in third human molars by wet abrasion. The adhesives were applied to a delimited area of 52 mm(2) on wet surfaces, for 40, 90, 150 and 300s. Four teeth were assigned for each experimental condition. Composite build-ups were constructed incrementally After water storage at 37 degrees C for 24 h, teeth were sectioned to obtain sticks with cross-sectional areas of 0.8 mm(2) to be tested in tension (0.5 mm/min) either immediately (IM) or after 3 years (3Y) of water storage. The microtensile bond strength (mu TBS) values were analyzed by two way repeated measures ANOVA and Tukey`s test (alpha = 0.05). Results. The 90- and 150-s groups achieved the highest IM mu TBS for OS (p < 0.01). For SB, the highest IM mu TBS values were observed after 300-s application (p < 0.01). Significant decreases in mu TBS were observed for OS in the 40- and 90-s groups after 3Y, except for the 150-s group. With regard to SB, after 3Y significant drops in mu TBS values were observed for the 40- and 150-s groups, except for the 300-s group. Significance. Prolonged application times can increase the immediate LTBS of two-step etch-and-rinse adhesive systems and make the adhesive layer more stable over time. (c) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.