994 resultados para Vertical displacement measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study is to present the application of a headspace-gas chromatography-mass spectrometry (HS-GC-MS) method for the determination of the carbon monoxide (CO) blood concentration and to compare it with carboxyhemoglobin (HbCO) saturation. In postmortem cases, the HbCO measured by spectrophotometry frequently leads to inaccurate results due to inadequate samples or analyses. The true role of CO intoxication in the death of a person could be misclassified. The estimation of HbCO from HS-GC-MS CO measurements provides helpful information by determining the total CO levels (CO linked to hemoglobin (HbCO) and CO dissociated from hemoglobin). The CO concentrations were converted in HbCO saturation levels to define cutoff blood CO values. CO limits were defined as less than 1 μmol/mL for living persons, less than 1.5 μmol/mL for dead persons without CO exposure, and greater than 3 μmol/mL for dead persons with clear CO poisoning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Propane can be responsible for several types of lethal intoxication and explosions. Quantifying it would be very helpful to determine in some cases the cause of death. Some gas chromatography-mass spectrometry (GC-MS) methods of propane measurements do already exist. The main drawback of these GC-MS methods described in the literature is the absence of a specific propane internal standard necessary for accurate quantitative analysis. The main outcome of the following study was to provide an innovative Headspace-GC-MS method (HS-GC-MS) applicable to the routine determination of propane concentration in forensic toxicology laboratories. To date, no stable isotope of propane is commercially available. The development of an in situ generation of standards is thus presented. An internal-labeled standard gas (C3DH7) is generated in situ by the stoichiometric formation of propane by the reaction of deuterated water (D2O) with Grignard reagent propylmagnesium chloride (C3H7MgCl). The method aims to use this internal standard to quantify propane concentrations and, therefore, to obtain precise measurements. Consequently, a complete validation with an accuracy profile according to two different guidelines, the French Society of Pharmaceutical Sciences and Techniques (SFSTP) and the Gesellschaft für toxikologische und Forensische Chemie (GTFCh), is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The diagnosis of pheochromocytoma relies on the measurement of plasma free metanephrines assay whose reliability has been considerably improved by ultra-high pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). Here we report an analytical interference occurring between 4-hydroxy-3-methoxymethamphetamine (HMMA), a metabolite of 3,4-methylenedioxymethamphetamine (MDMA, "Ecstasy"), and normetanephrine (NMN) since they share a common pharmacophore resulting in the same product ion after fragmentation. DESIGN AND METHODS: Synthetic HMMA was spiked into plasma samples containing various concentrations of NMN and the intensity of the interference was determined by UPLC-MS/MS before and after improvement of the analytical method. RESULTS: Using a careful adjustment of chromatographic conditions including the change of the UPLC analytical column, we were able to distinguish both compounds. HMMA interference for NMN determination should be seriously considered since MDMA activates the sympathetic nervous system and if confounded with NMN may lead to false-positive tests when performing a differential diagnostic of pheochromocytoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vertical delineators are intended to warn drivers of an approaching curve while providing them with a better appreciation of the sharpness of a curve. Drivers can then select an appropriate speed before entering the curve. Delineation can also provide continuous tracking information once drivers are within the curve to help position their vehicles within the travel lane while traversing the curve. The most common type of vertical delineation is post mounted delineators (PMDs). These devices are usually flexible or rigid posts with some amount of reflective surface mounted along the roadside to provide additional delineation. Another treatment that has been used is to provide additional delineation on chevron posts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multicomponent indicator displacement assay ( MIDA) based on an organometallic receptor and three dyes can be used for the identification and quantification of nucleotides in aqueous solution at neutral pH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mast cells are well known for their role in hypersensitivity reactions. However, there is increasing evidence that they might also participate in both developing and weakening atherosclerotic plaques, potentially causing plaque instability. Some clinical studies have therefore postulated the existence of relationships between blood β-tryptase levels and acute coronary syndromes. In this study, we investigated postmortem serum β-tryptase levels in a series of 90 autopsy cases with various degrees of coronary atherosclerosis that had undergone medico-legal investigations. β-tryptase concentrations in these cases were compared to levels observed in 6 fatal anaphylaxis cases following contrast material administration. Postmortem serum β-tryptase concentrations in the anaphylactic deaths ranged from 146 to 979 ng/ml. In 9 out of 90 cases of cardiac deaths, β-tryptase levels were higher than clinical reference values of 11.4 ng/ml and ranged from 21 to 65 ng/ml. These results indicate that increased postmortem serum β-tryptase levels can be observed, though not systematically, in cardiac deaths with varying degrees of coronary atherosclerosis disease, thereby suggesting that mast cell activation in this disease cannot be ascertained by postmortem serum β-tryptase measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this research project was to develop a method to measure the performance of a winter maintenance program with respect to the task of providing safety and mobility to the travelling public. Developing these measures required a number of steps, each of which was accomplished. First, the impact of winter weather on safety (crash rates) and mobility (average vehicle speeds were measured by a combination of literature reviews and analysis of Iowa Department of Transportation traffic and Road Weather Information System data. Second, because not all winter storms are the same in their effects on safety and mobility, a method had to be developed to determine how much the various factors that describe a winter storm actually change safety and mobility. As part of this effort a storm severity index was developed, which ranks each winter storm on a scale between 0 (a very benign storm) and 1 (the worst imaginable storm). Additionally a number of methods of modeling the relationships between weather, winter maintenance actions and road surface conditions were developed and tested. The end result of this study was a performance measure based on average vehicle speed. For a given class of road, a maximum expected average speed reduction has been identified. For a given storm, this maximum expected average speed reduction is modified by the storm severity index to give a target average speed reduction. Thus, if for a given road the maximum expected average speed reduction is 20 mph, and the storm severity for a particular storm is 0.6, then the target average speed reduction for that road in that storm is 0.6 x 20 mph or 12 mph. If the average speed on that road during and after the storm is only 12 mph or less than the average speed on that road in good weather conditions, then the winter maintenance performance goal has been met.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to evaluate hematological, biochemical and ruminant parameters for diagnosis and treatment of the left displaced abomasum (LDA) in dairy cows, in the Plateau Region of Rio Grande do Sul, Brazil. Ruminant fluid, blood and urine samples were collected from 20 cows suffering LDA and from 20 healthy cows (control). The cows with LDA showed lower values of daily milk production, body weight and corporal condition score. The use of pH reagent strips showed to be functional in the field, when compared to a digital pH meter. Ruminant dynamics was damaged in cows affected by LDA, as it was evidenced by the higher reduction time of methylene blue. Serum values of lactate, beta-hydroxybutyrate, urea, albumin, free fatty acids and cholesterol shows to be auxiliary tools in the LDA characterization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Faced with an increasing number of data and rankings, the author questions the roles of the different groups of actors who were originally involved in questioning the use of statistical indicators as a means of addressing issues of access to higher education. The comparison and nature of these international (UNESCO, OECD, EUROSTAT) and national (Germany, England, France, Switzerland) indicators in matters of inequalities of access to higher education question the tension between the discourses and the indicators they generate, and their recording at the national level. Who says what and with what consequences? What range of actors are involved in this process? What kind of power relations forms them? The author discusses how the issue of inequalities of access to higher education got on to the agendas of European organisations, identifies the policies that were defined, and sets them against an array of indicators, showing the discrepancy between the discourses and what the indicators reveal, the gap between the recommendations and the available tools. Why is there such a contrast? What are the mechanisms at work? Is it a technical or a political problem? What does this discrepancy reveal as far as national specificities within the construction of social inequalities are concerned?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the accuracy of a semiautomated 3D volume reconstruction method for organ volume measurement by postmortem MRI. METHODS: This prospective study was approved by the institutional review board and the infants' parents gave their consent. Postmortem MRI was performed in 16 infants (1 month to 1 year of age) at 1.5 T within 48 h of their sudden death. Virtual organ volumes were estimated using the Myrian software. Real volumes were recorded at autopsy by water displacement. The agreement between virtual and real volumes was quantified following the Bland and Altman's method. RESULTS: There was a good agreement between virtual and real volumes for brain (mean difference: -0.03% (-13.6 to +7.1)), liver (+8.3% (-9.6 to +26.2)) and lungs (+5.5% (-26.6 to +37.6)). For kidneys, spleen and thymus, the MRI/autopsy volume ratio was close to 1 (kidney: 0.87±0.1; spleen: 0.99±0.17; thymus: 0.94±0.25), but with a less good agreement. For heart, the MRI/real volume ratio was 1.29±0.76, possibly due to the presence of residual blood within the heart. The virtual volumes of adrenal glands were significantly underestimated (p=0.04), possibly due to their very small size during the first year of life. The percentage of interobserver and intraobserver variation was lower or equal to 10%, but for thymus (15.9% and 12.6%, respectively) and adrenal glands (69% and 25.9%). CONCLUSIONS: Virtual volumetry may provide significant information concerning the macroscopic features of the main organs and help pathologists in sampling organs that are more likely to yield histological findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because self-reported health status [SRHS] is an ordered response variable, inequality measurement for SRHS data requires a numerical scale for converting individual responses into a summary statistic. The choice of scale is however problematic, since small variations in the numerical scale may reverse the ordering of a given pair of distributions of SRHS data in relation to conventional inequality indices such as the variance. This paper introduces a parametric family of inequality indices, founded on an inequality ordering proposed by Allison and Foster [Allison, R.A., Foster, J., 2004. Measuring health inequalities using qualitative data. Journal of Health Economics 23, 505-524], which satisfy a suitable invariance property with respect to the choice of numerical scale. Several key members of the parametric family are also derived, and an empirical application using data from the Swiss Health Survey illustrates the proposed methodology. [Authors]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Vertical Clearance Log is prepared for the purpose of providing vertical clearance restrictions by route on the primary road system. This report is used by the Iowa Department of Transportation’s Motor Carrier Services to route oversize vehicles around structures with vertical restrictions too low for the cargo height. The source of the data is the Geographic Information Management System (GIMS) that is managed by the Office of Research & Analytics in the Performance & Technology Division. The data is collected by inspection crews and through the use of LiDAR technology to reflect changes to structures on the primary road system. This log is produced annually.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computer-Aided Tomography Angiography (CTA) images are the standard for assessing Peripheral artery disease (PAD). This paper presents a Computer Aided Detection (CAD) and Computer Aided Measurement (CAM) system for PAD. The CAD stage detects the arterial network using a 3D region growing method and a fast 3D morphology operation. The CAM stage aims to accurately measure the artery diameters from the detected vessel centerline, compensating for the partial volume effect using Expectation Maximization (EM) and a Markov Random field (MRF). The system has been evaluated on phantom data and also applied to fifteen (15) CTA datasets, where the detection accuracy of stenosis was 88% and the measurement accuracy was with an 8% error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the realm of forensic pathology, β-tryptase measurement for diagnostic purposes is performed in postmortem serum obtained from femoral blood. This may be partially or completely unavailable in some specific cases, such as infant autopsies and severely damaged bodies. The aim of this study was to investigate the usefulness of determining β-tryptase levels for diagnostic purposes in alternative biological samples. Urine, vitreous humor and pericardial fluid were selected and measured in 94 subjects including: fatal anaphylaxis following contrast material administration (6 cases), hypothermia (10 cases), diabetic ketoacidosis (10 cases), gunshot suicide (10 cases), heroin injection-related deaths (18 cases), trauma (10 cases), sudden death with minimal coronary atherosclerosis (10 cases), severe coronary atherosclerosis without myocardial infarction (10 cases) and severe coronary atherosclerosis with myocardial infarction (10 cases). Postmortem serum and pericardial fluid β-tryptase levels higher than the clinical reference value (11.4ng/ml) were systematically identified in fatal anaphylaxis following contrast material administration and 6 cases unrelated to anaphylaxis. β-tryptase concentrations in urine and vitreous humor were lower than the clinical reference value in all cases included in this study. Determination of β-tryptase in pericardial fluid appears to be a possible alternative to postmortem serum in the early postmortem period when femoral blood cannot be collected during autopsy and biochemical investigations are required to objectify increased β-tryptase levels.