958 resultados para VOOS LOW COST


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Theoretical and practical aspects of the use of microwave-assisted strategies in chemistry are introduced for students using simple and safe experiments employing a domestic oven. Three procedures are proposed for evaluating the distribution of microwave radiation inside the microwave oven cavity: (1) variation of the volume of marshmallows; (2) drying of filter paper wetted with Co(II) solution, and (3) variation of water temperature, after microwave-assisted heating. These experiments establish the position with the highest incidence of microwave radiation in the oven cavity, which was chosen for the synthesis of salicylic acid acetate. This synthesis was performed in 5 min of heating and the yield was around 85%. All experiments can be carried out in a 4 h lab-session using low-cost instrumentation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Anthropogenic pollution of groundwater and surface water has become a very serious environmental problem around the world. A wide range of toxic pollutants is recalcitrant to the conventional treatment methods, thus there is much interest in the development of more efficient remediation processes. Degradation of organic pollutants by zero-valent iron is one of the most promising approaches for water treatment, mainly because it is of low cost, easy to obtain and effective. After a general introduction to water pollution and current treatments, this work highlights the advances, applications and future trends of water remediation by zero-valent iron. Special attention is given to degradation of organochloride and nitroaromatic compounds, which are commonly found in textile and paper mill effluents.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper describes methodologies for the extraction and characterization by TLC, UV-VIS, IR and NMR of bixin from Bixa orellana L. (urucum) seeds. Based on the results, the extraction with NaOH 5% is the fastest, uses low-cost materials, requires two to four laboratory hours and is a useful alternative for an experimental Organic Chemistry discipline.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The soils of the world contain more carbon than the combined total amounts occurring in vegetation and the atmosphere. Hence soils are a major reservoir of carbon in terrestrial ecosystems and an important sink. Recently, emphasis has been placed on the need to sequester carbon from atmospheric carbon dioxide into soil organic matter because of international concerns about greenhouse gas emissions and global climate change. The best strategies to built-up carbon stocks in the soil are basically those that increase the input of organic matter to the soil, and/or decrease the rate of soil organic matter decomposition. Grain crop systems based on soil ploughing and harrowing lead to CO2 emissions combined with tremendous soil losses. In Brazil, no-tillage system was introduced to combat soil erosion by water and this soil management led to the build-up of soil carbon stocks with simultaneous high crop yields. However, the present procedure used to quantify carbon stocks in soils is laborious and of high cost. The use of infrared spectroscopy is very promising as an alternative low-cost method of soil carbon determination.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A simple low-cost flow cell was developed, built and optimized in order to observe dynamic interfacial tension of continuous flow systems. Distinct materials can be used in one of the cell walls in order to observe the intermolecular forces between the flowing liquid and the chemical constitution of the walls. The fluorescence depolarization was evaluated using Rhodamine B as fluorescent probe seeded in ethylene glycol. The effects of the positioning angles on the data acquired across the cell are reported. The reproducibility of the data was evaluated with a spectrometer assembled in-house and the relative standard deviation was below 3%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work proposes a fully-digital interface circuit for the measurement of inductive sensors using a low-cost microcontroller (µC) and without any intermediate active circuit. Apart from the µC and the sensor, the circuit just requires an external resistor and a reference inductance so that two RL circuits with a high-pass filter (HPF) topology are formed. The µC appropriately excites such RL circuits in order to measure the discharging time of the voltage across each inductance (i.e. sensing and reference) and then it uses such discharging times to estimate the sensor inductance. Experimental tests using a commercial µC show a non-linearity error (NLE) lower than 0.5%FSS (Full-Scale Span) when measuring inductances from 1 mH to 10 mH, and from 10 mH to 100 mH.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Thin layer chromatography is a quick, inexpensive and effective way of screening mixtures of non-volatile organic compounds and it is highly recommended for analytical studies. Inspection of plates under ultraviolet light for the detection of colourless compounds should be performed before any further chemical methods are applied. Construction of a low-cost UV-viewing cabinet with lamp employing parts easily found on the local market is described.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The state of São Paulo is the main Brazilian consumer of pesticides. Sugar cane, which uses a great amount of these products, is extensivelly cultivated in this state, such as in the Corumbataí river basin, an important source of water for the region. In order to implement an efficient and low-cost monitoring program, the temporal characterization of the use of pesticides on sugar cane in this basin was performed. After knowing the seasonal trends of consumption, a better choice of sampling time, became possible. The combination of data from this survey with partitioning indices, average doses and toxicological classifications showed to be important for defining the pesticides to be included in the monitoring program.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this article, the results of a modified SERVQUAL questionnaire (Parasuraman et al., 1991) are reported. The modifications consisted in substituting questionnaire items particularly suited to a specific service (banking) and context (county of Girona, Spain) for the original rather general and abstract items. These modifications led to more interpretable factors which accounted for a higher percentage of item variance. The data were submitted to various structural equation models which made it possible to conclude that the questionnaire contains items with a high measurement quality with respect to five identified dimensions of service quality which differ from those specified by Parasuraman et al. And are specific to the banking service. The two dimensions relating to the behaviour of employees have the greatest predictive power on overall quality and satisfaction ratings, which enables managers to use a low-cost reduced version of the questionnaire to monitor quality on a regular basis. It was also found that satisfaction and overall quality were perfectly correlated thus showing that customers do not perceive these concepts as being distinct

Relevância:

80.00% 80.00%

Publicador:

Resumo:

One of the most relevant properties of composite materials to be considered is stiffness. Fiberglass has been used traditionally as a fibrous reinforcing element when stiff materials are required. However, natural fibers are been exploited as replacements for synthetic fibers to satisfy environmental concerns. Among the different natural fibers, wood fibers show the combination of relatively high aspect ratio, good specific stiffness and strength, low density, low cost, and less variability than other natural fibers of such those from annual crops. In this work, composites from polypropylene and stone groundwood fibers from softwood were prepared and mechanically characterized under tensile loads. The Young’s moduli of the ensuing composites were analyzed and their micromechanics aspects evaluated. The reinforcing effect of stone groundwood fibers was compared to that of conventional reinforcement such fiberglass. The Halpin-Tsai model with the modification proposed by Tsai-Pagano accounted fairly for the behavior of PP composites reinforced with stone groundwood fibers. It was also demonstrated that the aspect ratio of the reinforcement plays a role in the Young’s modulus of injection molded specimens

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Zidovudine (AZT) and stavudine (D4T) are nucleoside reverse transcriptase inhibitors extensively used in human immunodeficiency virus (HIV) infected patients. In order to evaluate the quality of these drugs, two stability indicating HPLC methods were developed. The validated methods were applied in quantitative determination of AZT, D4T and their induced degradation products in capsule preparations. The stability studies were conducted at controlled temperature and relative humidity conditions based on the International Conference on Harmonization stability studies protocol for Zone IV areas. Easy sample preparation and low-cost make these methods especially useful for quality control and stability studies of AZT and D4T in drug products.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A simple, fast and low-cost methodology was optimized, seeking preparation of a crude pig liver esterase (PLE) concentrate. Basically, the method consisted of the following steps: liver homogenization, acetone washing, enzyme extraction and purification/concentration. Starting from 1 kg of fresh liver more than 200 kU of PLE suspension were obtained after 8 hours, at an estimated cost of US$0.21/kU. The PLE concentrate thus obtained was stable, showing 96-100% of the initial activity after 7 months in refrigerator at 4°C.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The modern stopped-flow reaction analyzer has shown high efficiency and flexibility, which provides outstanding sample economy with a dead-time of less than 1 ms. However the cost of the equipment imposes a serious restriction to many Brazilian scientists and teachers. In this work we describe the construction of a low-cost stopped-flow system coupled to a UV-Vis spectrophotometer. The performance of the system was checked by monitoring the kinetics of two reactions: the fading of phenolphthalein in aqueous alkaline solution and the chlorophyll a demetallation in acid medium. The apparatus showed reasonable efficiency with a dead-time of 0.3 to 0.5 s. The very good results obtained in these two illustrative processes show that the system is satisfactory for determining rate constants with mean reaction times ranging from seconds to minutes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Gravimetric and Bailey-Andrew methods are tedious and provide inflated results. Spectrofotometry is adequate for caffeine analysis but is lengthy. Gas chromatography also is applied to the caffeine analysis but derivatization is needed. High performance liquid chromatography with ultraviolet detection (HPLC-UV) and reversed phase is simple and rapid for xanthine multianalysis. In HPLC-UV-gel permeation, organic solvents are not used. HPLC-mass spectrometry provides an unequivocal structural identification of xanthines. Capillary electrophoresis is fast and the solvent consumption is smaller than in HPLC. Chemometric methods offer an effective means for chemical data handling in multivariate analysis. Infrared spectroscopy alone or associated with chemometries could predict the caffeine content in a very accurate form. Electroanalytical methods are considered of low cost and easy application in caffeine analysis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new procedure to find the limiting range of the photomultiplier linear response of a low-cost, digital oscilloscope-based time-resolved laser-induced luminescence spectrometer (TRLS), is presented. A systematic investigation on the instrument response function with different signal input terminations, and the relationship between the luminescence intensity reaching the photomultiplier and the measured decay time are described. These investigations establish that setting the maximum intensity of the luminescence signal below 0.3V guarantees, for signal input terminations equal or higher than 99.7 ohm, a linear photomultiplier response.