930 resultados para Ultrasound Oculometry


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Noninvasive or minimally invasive identification of sentinel lymph node (SLN) is essential to reduce the surgical effects of SLN biopsy. Photoacoustic (PA) imaging of SLN in animal models has shown its promise for clinical use in the future. Here, we present a Monte Carlo simulation for light transport in the SLN for various light delivery configurations with a clinical ultrasound probe. Our simulation assumes a realistic tissue layer model and also can handle the transmission/reflectance at SLN-tissue boundary due to the mismatch of refractive index. Various light incidence angles show that for deeply situated SLNs the maximum absorption of light in the SLN is for normal incidence. We also show that if a part of the diffused reflected photons is reflected back into the skin using a reflector, the absorption of light in the SLN can be increased significantly to enhance the PA signal. (C) 2013 Society of Photo-Optical Instrumentation Engineers (SPIE)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Various leg exercises have been recommended to prevent deep vein thrombosis (DVT), a condition where a blood clot forms in the deep veins, especially during long-haul flights. Accessing the benefit of each of these exercises in avoiding the DVT, which can be fatal, is important in the context of suggesting the correct and the most beneficial exercises. Present work aims at demonstrating the fiber Bragg grating (FBG)-based sensing methodology for measuring surface strains generated on the skin of the calf muscle to evaluate the suggested airline exercises to avoid DVT. As the dataset in the experiment involves multiple subjects performing these exercises, an inertial measurement unit has been used to validate the repetitiveness of each of the exercises. The surface strain on the calf muscle obtained using the FBG sensor, which is a measure of the calf muscle deformation, has been compared against the variation of blood velocity in the femoral vein of the thigh measured using a commercial electronic-phased array color Doppler ultrasound system. Apart from analyzing the effectiveness of suggested exercises, a new exercise which is more effective in terms of strain generated to avoid DVT is proposed and evaluated. (C) 2013 Society of Photo-Optical Instrumentation Engineers (SPIE)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spatial resolution in photoacoustic and thermoacoustic tomography is ultrasound transducer (detector) bandwidth limited. For a circular scanning geometry the axial (radial) resolution is not affected by the detector aperture, but the tangential (lateral) resolution is highly dependent on the aperture size, and it is also spatially varying (depending on the location relative to the scanning center). Several approaches have been reported to counter this problem by physically attaching a negative acoustic lens in front of the nonfocused transducer or by using virtual point detectors. Here, we have implemented a modified delay-and-sum reconstruction method, which takes into account the large aperture of the detector, leading to more than fivefold improvement in the tangential resolution in photoacoustic (and thermoacoustic) tomography. Three different types of numerical phantoms were used to validate our reconstruction method. It is also shown that we were able to preserve the shape of the reconstructed objects with the modified algorithm. (C) 2014 Optical Society of America

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PurposeTo extend the previously developed temporally constrained reconstruction (TCR) algorithm to allow for real-time availability of three-dimensional (3D) temperature maps capable of monitoring MR-guided high intensity focused ultrasound applications. MethodsA real-time TCR (RT-TCR) algorithm is developed that only uses current and previously acquired undersampled k-space data from a 3D segmented EPI pulse sequence, with the image reconstruction done in a graphics processing unit implementation to overcome computation burden. Simulated and experimental data sets of HIFU heating are used to evaluate the performance of the RT-TCR algorithm. ResultsThe simulation studies demonstrate that the RT-TCR algorithm has subsecond reconstruction time and can accurately measure HIFU-induced temperature rises of 20 degrees C in 15 s for 3D volumes of 16 slices (RMSE = 0.1 degrees C), 24 slices (RMSE = 0.2 degrees C), and 32 slices (RMSE = 0.3 degrees C). Experimental results in ex vivo porcine muscle demonstrate that the RT-TCR approach can reconstruct temperature maps with 192 x 162 x 66 mm 3D volume coverage, 1.5 x 1.5 x 3.0 mm resolution, and 1.2-s scan time with an accuracy of 0.5 degrees C. ConclusionThe RT-TCR algorithm offers an approach to obtaining large coverage 3D temperature maps in real-time for monitoring MR-guided high intensity focused ultrasound treatments. Magn Reson Med 71:1394-1404, 2014. (c) 2013 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acidic region streaking (ARS) is one of the lacunae in two-dimensional gel electrophoresis (2DE) of bacterial proteome. This streaking is primarily caused by nucleic acid (NuA) contamination and poses major problem in the downstream processes like image analysis and protein identification. Although cleanup and nuclease digestion are practiced as remedial options, these strategies may incur loss in protein recovery and perform incomplete removal of NuA. As a result, ARS has remained a common observation across publications, including the recent ones. In this work, we demonstrate how ultrasound wave can be used to shear NuA in plain ice-cooled water, facilitating the elimination of ARS in the 2DE gels without the need for any additional sample cleanup tasks. In combination with a suitable buffer recipe, IEF program and frequent paper-wick changing approach, we are able to reproducibly demonstrate the production of clean 2DE gels with improved protein recovery and negligible or no ARS. We illustrate our procedure using whole cell protein extracts from two diverse organisms, Escherichia coli and Mycobacterium smegmatis. Our designed protocols are straightforward and expected to provide good 2DE gels without ARS, with comparable times and significantly lower cost.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present work, we report a novel, in vivo, noninvasive technique to determine radial arterial compliance using the radial arterial pressure pulse waveform (RAPPW) acquired by fiber Bragg grating pulse recorder (FBGPR). The radial arterial compliance of the subject can be measured during sphygmomanometric examination by the unique signatures of arterial diametrical variations and the beat-to-beat pulse pressure acquired simultaneously from the RAPPW recorded using FBGPR. This proposed technique has been validated against the radial arterial diametrical measurements obtained from the color Doppler ultrasound. Two distinct trials have been illustrated in this work and the results from both techniques have been found to be in good agreement with each other.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Imaging the vasculature close around the finger joints is of interest in the field of rheumatology. Locally increased vasculature in the synovial membrane of these joints can be a marker for rheumatoid arthritis. In previous work we showed that part of the photoacoustically induced ultrasound from the epidermis reflects on the bone surface within the finger. These reflected signals could be wrongly interpreted as new photoacoustic sources. In this work we show that a conventional ultrasound reconstruction algorithm, that considers the skin as a collection of ultrasound transmitters and the PA tomography probe as the detector array, can be used to delineate bone surfaces of a finger. This can in the future assist in the localization of the joint gaps. This can provide us with a landmark to localize the region of the inflamed synovial membrane. We test the approach on finger mimicking phantoms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inflammatory arthritis is often manifested in finger joints. The growth of new or withdrawal of old blood vessels can be a sensitive marker for these diseases. Photoacoustic (PA) imaging has great potential in this respect since it allows the sensitive and highly resolved visualization of blood. We systematically investigated PA imaging of finger vasculature in healthy volunteers using a newly developed PA tomographic system. We present the PA results which show excellent detail of the vasculature. Vessels with diameters ranging between 100 mu m and 1.5 mm are visible along with details of the skin, including the epidermis and the subpapillary plexus. The focus of all the studies is at the proximal and distal interphalangeal joints, and in the context of ultimately visualizing the inflamed synovial membrane in patients. This work is important in laying the foundation for detailed research into PA imaging of the phalangeal vasculature in patients suffering from rheumatoid arthritis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study reports a noninvasive technique for the measurement of the pulse transit time differential (PTTD) from the pulse pressure waveforms obtained at the carotid artery and radial artery using fiber Bragg grating pulse recorders (FBGPR). PTTD is defined as the time difference between the arrivals of a pulse pressure waveform at the carotid and radial arterial sites. The PTTD is investigated as an indicator of variation in the systolic blood pressure. The results are validated against blood pressure variation obtained from a Mindray Patient Monitor. Furthermore, the pulse wave velocity computed from the obtained PTTD is compared with the pulse wave velocity obtained from the color Doppler ultrasound system and is found to be in good agreement. The major advantage of the PTTD measurement via FBGPRs is that the data acquisition system employed can simultaneously acquire pulse pressure waveforms from both FBGPRs placed at carotid and radial arterial sites with a single time scale, which eliminates time synchronization complexity. (C) 2015 Society of Photo-Optical Instrumentation Engineers (SPIE)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Photoacoustic (PA) imaging of interphalangeal peripheral joints is of interest in the context of using the synovial membrane as a surrogate marker of rheumatoid arthritis. Previous work has shown that ultrasound (US) produced by absorption of light at the epidermis reflects on the bone surfaces within the finger. When the reflected signals are backprojected in the region of interest, artifacts are produced, confounding interpretation of the images. In this work, we present an approach where the PA signals known to originate from the epidermis are treated as virtual US transmitters, and a separate reconstruction is performed as in US reflection imaging. This allows us to identify the bone surfaces. Furthermore, the identification of the joint space is important as this provides a landmark to localize a region-of-interest in seeking the inflamed synovial membrane. The ability to delineate bone surfaces allows us to identify not only the artifacts but also the interphalangeal joint space without recourse to new US hardware or a new measurement. We test the approach on phantoms and on a healthy human finger.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article presents a new method for acquiring three-dimensional (3-D) volumes of ultrasonic axial strain data. The method uses a mechanically-swept probe to sweep out a single volume while applying a continuously varying axial compression. Acquisition of a volume takes 15-20 s. A strain volume is then calculated by comparing frame pairs throughout the sequence. The method uses strain quality estimates to automatically pick out high quality frame pairs, and so does not require careful control of the axial compression. In a series of in vitro and in vivo experiments, we quantify the image quality of the new method and also assess its ease of use. Results are compared with those for the current best alternative, which calculates strain between two complete volumes. The volume pair approach can produce high quality data, but skillful scanning is required to acquire two volumes with appropriate relative strain. In the new method, the automatic quality-weighted selection of image pairs overcomes this difficulty and the method produces superior quality images with a relatively relaxed scanning technique.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Advances in optical techniques have enabled many breakthroughs in biology and medicine. However, light scattering by biological tissues remains a great obstacle, restricting the use of optical methods to thin ex vivo sections or superficial layers in vivo. In this thesis, we present two related methods that overcome the optical depth limit—digital time reversal of ultrasound encoded light (digital TRUE) and time reversal of variance-encoded light (TROVE). These two techniques share the same principle of using acousto-optic beacons for time reversal optical focusing within highly scattering media, like biological tissues. Ultrasound, unlike light, is not significantly scattered in soft biological tissues, allowing for ultrasound focusing. In addition, a fraction of the scattered optical wavefront that passes through the ultrasound focus gets frequency-shifted via the acousto-optic effect, essentially creating a virtual source of frequency-shifted light within the tissue. The scattered ultrasound-tagged wavefront can be selectively measured outside the tissue and time-reversed to converge at the location of the ultrasound focus, enabling optical focusing within deep tissues. In digital TRUE, we time reverse ultrasound-tagged light with an optoelectronic time reversal device (the digital optical phase conjugate mirror, DOPC). The use of the DOPC enables high optical gain, allowing for high intensity optical focusing and focal fluorescence imaging in thick tissues at a lateral resolution of 36 µm by 52 µm. The resolution of the TRUE approach is fundamentally limited to that of the wavelength of ultrasound. The ultrasound focus (~ tens of microns wide) usually contains hundreds to thousands of optical modes, such that the scattered wavefront measured is a linear combination of the contributions of all these optical modes. In TROVE, we make use of our ability to digitally record, analyze and manipulate the scattered wavefront to demix the contributions of these spatial modes using variance encoding. In essence, we encode each spatial mode inside the scattering sample with a unique variance, allowing us to computationally derive the time reversal wavefront that corresponds to a single optical mode. In doing so, we uncouple the system resolution from the size of the ultrasound focus, demonstrating optical focusing and imaging between highly diffusing samples at an unprecedented, speckle-scale lateral resolution of ~ 5 µm. Our methods open up the possibility of fully exploiting the prowess and versatility of biomedical optics in deep tissues.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Saguzarrak orden dibertsoa osatzen eta funtzio ekologiko garrantzitsua betetzen duten arren, hauetako asko galtzeko arriskuan daude. Animalia hauek ondo babestu ahal izateko, garrantzitsua da erabili ohi dituzten babeslekuak ezagutzea. Hau horrela, Aizkorri-Aratz Parke Naturaleko haitzuloetako saguzar dibertsitatea aztertu da denbora errealeko ultrasoinu detektoreen bidez, ager daitezkeen saguzar espezieak, koloniak eta babeslekuak identifikatzen saiatzeko. 18 haitzulotan ilunabarreko emergentziatan egindako laginketaren ondoren, lan honetan zazpi genero eta zazpi espezie identifikatu dira parkean, eta hauetako sei haitzuloetako espezieak dira. Saguzar-aktibitatea ikusi den arren, ez da inguru honetan saguzar-kolonia berri adierazgarririk aurkitu.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Casa da Moeda do Brasil (CMB) é uma empresa nacional, com mais de 300 anos de experiência na produção de valores e impressos de segurança. A produção de cédulas, realizada pelo Departamento de Cédulas (DECED), consiste de três etapas de impressão, off-set, calografia e tipografia, seguida de acabamento e embalagem semi-automatizado. A impressão calcográfica consome solução de limpeza, composta de soda cáustica e óleo sulfonado, para limpeza do cilindro de impressão, gerando um efluente líquido saturado de tinta. Este efluente apresenta baixa biodegradabilidade, apresentando uma relação DBO / DQO de aproximadamente 1:4. Em termos de tratabilidade, as estações de tratamento de efluentes (ETE) apresentam uma configuração convencional, por via biológica, demonstram pouca eficiência na degradação da matéria orgânica deste efluente. Com compostos recalcitrantes, torna-se necessária a inclusão de uma etapa terciária que permita sua degradação por via química, permitindo o descarte do efluente com características menos danosas ao ambiente. Neste trabalho, aplicou-se a reação de Fenton no efluente do DECED por sua capacidade de converter a matéria orgânica em gás carbônico e água ou, caso seja utilizado em pré-tratamentos, torna-os biodegradáveis. Foram estudadas diferentes condições para medir a influência de diferentes parâmetros na eficiência da reação. A reação de Fenton consiste na geração de radicais hidroxil (HO), por diferentes rotas, em quantidades suficientes para a degradação de matéria orgânica. Esses radicais são gerados a partir de peróxido de hidrogênio (H2O2) em reações com diferentes precursores como ozônio (O3), luz UV (ultravioleta), ultra-som e sais de ferro. No presente trabalho restringiu-se às reações com sais de ferro. Dentre os resultados obtidos, verificou-se o tempo mínimo para reação em 10 minutos. A relação entre íons ferro e peróxido de hidrogênio é menor do que a literatura normalmente sugere, 1:2, contra 1:3. Como a solução de sulfato ferroso é muito instável, passando os íons ferrosos a férricos, utilizou-se a adição direta do sal. Em escala industrial, a solução de sulfato ferroso deve ser preparada em poucas quantidades para que tenha baixo tempo de estocagem, a fim de não ser degradada. A temperatura, na faixa estudada (de 20C à 45C), é um parâmetro que tem pouca influência, pois a redução da eficiência da reação foi pequena (de 99,0% para 94,9%). O ferro utilizado na reação não se demonstrou uma nova fonte de transtornos para o ambiente. Nas condições utilizadas, a concentração de ferro residual esteve próxima ao limite permitido pela legislação no efluente tratado, necessitando apenas de alguns ajustes para a correção do problema