977 resultados para Transcatheter aortic valve replacement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The directional flow of lymph is maintained by hundreds of intraluminal lymphatic valves. Lymphatic valves are crucial to prevent lymphedema, accumulation of fluid in the tissues, and to ensure immune surveillance; yet, the mechanisms of valve formation are only beginning to be elucidated. In this chapter, we will discuss the main steps of lymphatic valve morphogenesis, the important role of mechanotransduction in this process, and the genetic program regulated by the transcription factor Foxc2, which is indispensable for all steps of valve development. Failure to form mature collecting lymphatic vessels and valves causes the majority of postsurgical lymphedema, e.g., in breast cancer patients. Therefore, this knowledge will be useful for diagnostics and development of better treatments of secondary lymphedema.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Total ankle replacement (TAR) is increasingly used for treatment of primary or posttraumatic arthritis of the ankle joint, if joint movement is intended to be preserved. Data on characteristics and treatment of ankle prosthetic joint infection (PJI) is limited and no validated therapeutic algorithm exist. Therefore, we analyzed all infections, which occurred in a cohort of implanted ankle prostheses during a 5-year-period.Methods: Between 06/2004 and 12/2008, all patients with an implanted ankle prosthesis at our institution were retrospectively reviewed. All patients were operated by the same surgical team. Ankle PJI was defined as visible purulence, acute inflammation on histopathology, sinus tract, or microbial growth in periprosthetic tissue or sonication fluid of the removed prosthesis. The surgery on the infected ankle prosthesis and the follow-up were performed by the surgical team, who implanted the prosthesis. A specialized septic team consisting of an orthopaedic surgeon and infectious diseases consultant were included in the treatment.Results: During the study period, 92 total ankle prostheses were implanted in 90 patients (mean age 61 years, range 28-80 years). 78 patients had posttraumatic arthritis, 11 rheumatoid arthritis and 3 other degenerative disorder. Ankle PJI occurred in 3 of 92 TAR (3.3%), occurring 1, 2 and 24 months after implantation; the causative organisms were Enterobacter cloacae, Streptococcus pyogenes and Staphylococcus epidermidis, respectively. The ankle prosthesis was removed in all infected patients, including debridement of the surrounding tissue was debrided and insertion of an antibiotic loaded spacer. Provisional arthrodesis was performed by external fixation in two patients and by plaster cast in one. A definitive ankle arthrodesis with a retrograde nail was performed 6 to 8 weeks after prosthesis removal. One patient needed a flap coverage. All 3 patients received intravenous antibiotic treatment for 2 weeks, followed by oral antibiotics for 4-6 weeks. At follow-up visit up to 18 months after start of treatment, all patients were without clinical or laboratory signs of infection.Conclusions: The infection incidence after TAR was 3.3%, which is slightly higher than reported after hip (<1%) or knee arthroplasty (<2%). A two-step approach consisting of removal of the infected prosthesis, combined with local and systemic antibiotic treatment, followed by definitive ankle arthrodesis shows good results. Larger patient cohort and longer follow-up evaluation is needed to define the optimal treatment approach for ankle PJI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

J Clin Hypertens (Greenwich). 2012;14:773-778. ©2012 Wiley Periodicals, Inc. Postmenopausal women are at greater risk for hypertension-related cardiovascular disease. Antihypertensive therapy may help alleviate arterial stiffness that represents a potential modifiable risk factor of hypertension. This randomized controlled study investigated the difference between an angiotensin receptor blocker and a calcium channel blocker in reducing arterial stiffness. Overall, 125 postmenopausal hypertensive women (age, 61.4±6 years; systolic blood pressure/diastolic blood pressure [SBP/DBP], 158±11/92±9 mm Hg) were randomized to valsartan 320 mg±hydrochlorothiazide (HCTZ) (n=63) or amlodipine 10 mg±HCTZ (n=62). The primary outcome was carotid-to-femoral pulse wave velocity (PWV) changes after 38 weeks of treatment. Both treatments lowered peripheral blood pressure (BP) (-22.9/-10.9 mm Hg for valsartan and -25.2/-11.7 mm Hg for amlodipine, P=not significant) and central BP (-15.7/-7.6 mm Hg for valsartan and -19.2/-10.3 mm Hg for amlodipine, P<.05 for central DBP). Both treatments similarly reduced the carotid-femoral PWV (-1.9 vs -1.7 m/s; P=not significant). Amlodipine was associated with a higher incidence of peripheral edema compared with the valsartan group (77% vs 14%, P<.001). BP lowering in postmenopausal women led to a reduction in arterial stiffness as assessed by PWV measurement. Both regimens reduced PWV to a similar degree after 38 weeks of treatment despite differences in central BP lowering, suggesting that the effect of valsartan on PWV is mediated through nonhemodynamic effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: A straightforward original Chimney Graft (CG) protocol has been developed at our institution in selected cases of juxtarenal aortic aneurysm (JRAA). The aim of this study was to present our clinical experience of consecutive series with use of uncovered self-expanding stent (SES) as "Open Chimney" (OCh) in the endovascular repair (EVAR) of JRAA. METHODS: A standard endograft with suprarenal fixation struts is delivered with its proximal covered edge just below the highest RA in JRAA presenting the ostium of the two renal arteries at a different aortic level and the distance between the highest renal artery and the beginning of the aneurysm (improved landing zone) ≥10 mm. The low-lying renal artery is maintained patent by the OCh graft (standard SES) delivered from left brachial access (6 Fr). All clinical, anatomical, and operative data were prospectively collected and retrieved for the study analysis. RESULTS: From July 2010 to November 2012, OCh EVAR was offered to 22 consecutive patients considered unfit for JRAA open repair. All procedures were technically successful with aneurysm exclusion and patent OCh graft. One small perioperative type Ia endoleak spontaneously disappeared at the 3-month CT control. One patient died because of acute decompensated heart failure. One patient presented a left hemispheric stroke. The median follow-up of 18 months (range 7-35) showed aneurysm exclusion in all patients without type I and III endoleaks, SES stenosis, and/or renal impairment. CONCLUSIONS: OCh-EVAR is a straightforward technique that can be employed in selected cases of JRAA, avoiding the more complex and expensive fenestrated EVAR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Atherosclerosis results in a considerable medical and socioeconomic impact on society. We sought to evaluate novel magnetic resonance imaging (MRI) angiography and vessel wall sequences to visualize and quantify different morphologic stages of atherosclerosis in a Watanabe hereditary hyperlipidemic (WHHL) rabbit model. MATERIAL AND METHODS: Aortic 3D steady-state free precession angiography and subrenal aortic 3D black-blood fast spin-echo vessel wall imaging pre- and post-Gadolinium (Gd) was performed in 14 WHHL rabbits (3 normal, 6 high-cholesterol diet, and 5 high-cholesterol diet plus endothelial denudation) on a commercial 1.5 T MR system. Angiographic lumen diameter, vessel wall thickness, signal-/contrast-to-noise analysis, total vessel area, lumen area, and vessel wall area were analyzed semiautomatically. RESULTS: Pre-Gd, both lumen and wall dimensions (total vessel area, lumen area, vessel wall area) of group 2 + 3 were significantly increased when compared with those of group 1 (all P < 0.01). Group 3 animals had significantly thicker vessel walls than groups 1 and 2 (P < 0.01), whereas angiographic lumen diameter was comparable among all groups. Post-Gd, only diseased animals of groups 2 + 3 showed a significant (>100%) signal-to-noise ratio and contrast-to-noise increase. CONCLUSIONS: A combination of novel 3D magnetic resonance angiography and high-resolution 3D vessel wall MRI enabled quantitative characterization of various atherosclerotic stages including positive arterial remodeling and Gd uptake in a WHHL rabbit model using a commercially available 1.5 T MRI system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total disc replacement (TDR) clinical success has been reported to be related to the residual motion of the operated level. Thus, accurate measurement of TDR range of motion (ROM) is of utmost importance. One commonly used tool in measuring ROM is the Oxford Cobbometer. Little is known however on its accuracy (precision and bias) in measuring TDR angles. The aim of this study was to assess the ability of the Cobbometer to accurately measure radiographic TDR angles. An anatomically accurate synthetic L4-L5 motion segment was instrumented with a CHARITE artificial disc. The TDR angle and anatomical position between L4 and L5 was fixed to prohibit motion while the motion segment was radiographically imaged in various degrees of rotation and elevation, representing a sample of possible patient placement positions. An experienced observer made ten readings of the TDR angle using the Cobbometer at each different position. The Cobbometer readings were analyzed to determine measurement accuracy at each position. Furthermore, analysis of variance was used to study rotation and elevation of the motion segment as treatment factors. Cobbometer TDR angle measurements were most accurate (highest precision and lowest bias) at the centered position (95.5%), which placed the TDR directly inline with the x-ray beam source without any rotation. In contrast, the lowest accuracy (75.2%) was observed in the most rotated and off-centered view. A difference as high as 4 degrees between readings at any individual position, and as high as 6 degrees between all the positions was observed. Furthermore, the Cobbometer was unable to detect the expected trend in TDR angle projection with changing position. Although the Cobbometer has been reported to be reliable in different clinical applications, it lacks the needed accuracy to measure TDR angles and ROM. More accurate ROM measurement methods need to be developed to help surgeons and researchers assess radiological success of TDRs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The risk of catheter-related infection or bacteremia, with initial and extended use of femoral versus nonfemoral sites for double-lumen vascular catheters (DLVCs) during continuous renal replacement therapy (CRRT), is unclear. STUDY DESIGN: Retrospective observational cohort study. SETTING & PARTICIPANTS: Critically ill patients on CRRT in a combined intensive care unit of a tertiary institution. FACTOR: Femoral versus nonfemoral venous DLVC placement. OUTCOMES: Catheter-related colonization (CRCOL) and bloodstream infection (CRBSI). MEASUREMENTS: CRCOL/CRBSI rates expressed per 1,000 catheter-days. RESULTS: We studied 458 patients (median age, 65 years; 60% males) and 647 DLVCs. Of 405 single-site only DLVC users, 82% versus 18% received exclusively 419 femoral versus 82 jugular or subclavian DLVCs, respectively. The corresponding DLVC indwelling duration was 6±4 versus 7±5 days (P=0.03). Corresponding CRCOL and CRBSI rates (per 1,000 catheter-days) were 9.7 versus 8.8 events (P=0.8) and 1.2 versus 3.5 events (P=0.3), respectively. Overall, 96 patients with extended CRRT received femoral-site insertion first with subsequent site change, including 53 femoral guidewire exchanges, 53 new femoral venipunctures, and 47 new jugular/subclavian sites. CRCOL and CRBSI rates were similar for all such approaches (P=0.7 and P=0.9, respectively). On multivariate analysis, CRCOL risk was higher in patients older than 65 years and weighing >90kg (ORs of 2.1 and 2.2, respectively; P<0.05). This association between higher weight and greater CRCOL risk was significant for femoral DLVCs, but not for nonfemoral sites. Other covariates, including initial or specific DLVC site, guidewire exchange versus new venipuncture, and primary versus secondary DLVC placement, did not significantly affect CRCOL rates. LIMITATIONS: Nonrandomized retrospective design and single-center evaluation. CONCLUSIONS: CRCOL and CRBSI rates in patients on CRRT are low and not influenced significantly by initial or serial femoral catheterizations with guidewire exchange or new venipuncture. CRCOL risk is higher in older and heavier patients, the latter especially so with femoral sites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Regional citrate anticoagulation of the extracorporeal circuits (CRA) experienced considerable growth over the past decade. This development is partly explained by the significant progresses made in the field of bioengineering. These allow a secure administration of citrate, while an increasing availability of ionized calcium measurement at the bedside allows reactivity in monitoring the treatment. An increasing severity of the medical condition of patients requiring blood purification treatment gives more contrast to the profile of patient who may benefit from a CRA. If some methods of renal replacement therapy are well suited to this mode of anticoagulation, others are, to date, only at the stage of development and are applied under close medical supervision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic Repair Complications reported a total of 63 rAAD cases (incidence, 1.33%; 95% CI, 0.75 to 2.40). Eighty-one percent of patients underwent TEVAR for acute (n=26, 54%) or chronic type B dissection (n=13, 27%). Stent grafts with proximal bare springs were used in majority of patients (83%). Only 7 (15%) patients had intraoperative rAAD, with the remaining occurring during the index hospitalization (n=10, 21%) and during follow-up (n=31, 64%). Presenting symptoms included acute chest pain (n=16, 33%), syncope (n=12, 25%), and sudden death (n=9, 19%) whereas one fourth of patients were asymptomatic (n=12, 25%). Most patients underwent emergency (n=25) or elective (n=5) surgical repair. Outcome was fatal in 20 of 48 patients (42%). Causes of rAAD included the stent graft itself (60%), manipulation of guide wires/sheaths (15%), and progression of underlying aortic disease (15%). CONCLUSIONS: The incidence of rAAD was low (1.33%) in the present analysis with high mortality (42%). Patients undergoing TEVAR for type B dissection appeared to be most prone for the occurrence of rAAD. This complication occurred not only during the index hospitalization but after discharge up to 1050 days after TEVAR. Importantly, the majority of rAAD cases were associated with the use of proximal bare spring stent grafts with direct evidence of stent graft-induced injury at surgery or necropsy in half of the patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Abdominal aortic aneurysms (AAAs) expand because of aortic wall destruction. Enrichment in Vascular Smooth Muscle Cells (VSMCs) stabilizes expanding AAAs in rats. Mesenchymal Stem Cells (MSCs) can differentiate into VSMCs. We have tested the hypothesis that bone marrow-derived MSCs (BM-MSCs) stabilizes AAAs in a rat model. MATERIAL AND METHODS: Rat Fischer 344 BM-MSCs were isolated by plastic adhesion and seeded endovascularly in experimental AAAs using xenograft obtained from guinea pig. Culture medium without cells was used as control group. The main criteria was the variation of the aortic diameter at one week and four weeks. We evaluated the impact of cells seeding on inflammatory response by immunohistochemistry combined with RT-PCR on MMP9 and TIMP1 at one week. We evaluated the healing process by immunohistochemistry at 4 weeks. RESULTS: The endovascular seeding of BM-MSCs decreased AAA diameter expansion more powerfully than VSMCs or culture medium infusion (6.5% ± 9.7, 25.5% ± 17.2 and 53.4% ± 14.4; p = .007, respectively). This result was sustained at 4 weeks. BM-MSCs decreased expression of MMP-9 and infiltration by macrophages (4.7 ± 2.3 vs. 14.6 ± 6.4 mm(2) respectively; p = .015), increased Tissue Inhibitor Metallo Proteinase-1 (TIMP-1), compared to culture medium infusion. BM-MSCs induced formation of a neo-aortic tissue rich in SM-alpha active positive cells (22.2 ± 2.7 vs. 115.6 ± 30.4 cells/surface units, p = .007) surrounded by a dense collagen and elastin network covered by luminal endothelial cells. CONCLUSIONS: We have shown in this rat model of AAA that BM-MSCs exert a specialized function in arterial regeneration that transcends that of mature mesenchymal cells. Our observation identifies a population of cells easy to isolate and to expand for therapeutic interventions based on catheter-driven cell therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare effects of a non-renin-angiotensin system (RAS) blocker, using a CCB, or a RAS blocker, using an ARB regimen on the arterial stiffness reduction in postmenopausal hypertensive women. Methods: In this prospective study, a total of 125 hypertensive women (age: 61.4_6 yrs; 98% Caucasian; BW: 71.9_14 kg; BMI: 27.3_5 kg/m2; SBP/ DBP: 158_11/92_9 mmHg) were randomized between ARB (valsartan 320mg_HCTZ) and CCB (amlodipine 10mg _ HCTZ). The primary outcome was carotid-femoral pulse wave velocity (PWV) changes after 38 weeks of treatment. Results: There were no significant differences in baseline demographic data between the two groups. Both treatments effectively lowered BP at the end of the study with similar (p>0.05) reductions in the valsartan (_22.9/_10.9 mmHg) and amlodipine based (_25.2/_11.7 mmHg) treatment groups. Despite a lower (p<0.05 for DBP) central SBP/DBP in the CCB group (_19.2/_10.3 mmHg) compared to the valsartan group (_15.7/_7.6 mmHg) at week 38, a similar reduction in carotid-femoral PWV (_1.7 vs _1.9 m/sec; p>0.05) was observed between both groups. The numerically larger BP reduction observed in the CCB group was associated with a much higher incidence of peripheral edema (77% vs 14%) than the valsartan group. Conclusion: In summary, BP lowering in postmenopausal women led to a reduction in arterial stiffness assessed by PWV measurement. Both regimens reduced PWV at 38 weeks of treatment to a similar degree, despite differences in BP lowering suggesting that the effect of RAS blockade to influence PWV may partly be independent of BP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims To evaluate thoracic aortic dilation in patients with Fabry disease (FD). Methods and results A cohort of 106 patients with FD (52 males; 54 females) from three European centres were studied. The diameter of the thoracic aorta was assessed at three levels (sinus of Valsalva, ascending aorta, and descending aorta) using echocardiograms and cardiovascular magnetic resonance imaging. Aortic dilation at the sinus of Valsalva was found in 32.7% of males and 5.6% of females; aneurysms were present in 9.6% of males and 1.9% of females. No aortic dilation was observed in the descending aorta. There was no correlation between aortic diameter at the sinus of Valsalva and cardiovascular risk factors. Conclusion Fabry disease should be considered as a cardiovascular disease that affects the heart and arterial vasculature, including the thoracic aorta. Thus, patients with FD should be closely monitored for the presence, and possible progression and complications of aortic dilation. Clinical Trial Registration: Protocol 101/01. Ethics committee, Faculty of Medicine, Lausanne.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bridge deck expansion joints are used to allow for movement of the bridge deck due to thermal expansion, dynamics loading, and other factors. More recently, expansion joints have also been utilized to prevent the passage of winter de-icing chemicals and other corrosives applied to bridge decks from penetrating and damaging substructure components of the bridge. Expansion joints are often one of the first components of a bridge deck to fail and repairing or replacing expansion joints are essential to extending the life of any bridge. In the Phase I study, the research team focused on the current means and methods of repairing and replacing bridge deck expansion joints. Research team members visited with Iowa Department of Transportation (DOT) Bridge Crew Leaders to document methods of maintaining and repairing bridge deck expansion joints. Active joint replacement projects around Iowa were observed to document the means of replacing expansion joints that were beyond repair, as well as, to identify bottlenecks in the construction process that could be modified to decrease the length of expansion joint replacement projects. After maintenance and replacement strategies had been identified, a workshop was held at the Iowa State Institute for Transportation to develop ideas to better maintain and replace expansion joints. Maintenance strategies were included in the discussion as a way to extend the useful life of a joint, thus decreasing the number of joints replaced in a year and reducing the traffic disruptions.